Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K192946

    Validate with FDA (Live)

    Date Cleared
    2019-11-26

    (39 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K093736

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Total hip replacement or hip arthroplasty is indicated in the following conditions:

    1. A severely painful and/or disabled joint from osteoarthritis, rheumatoid arthritis, or congenital hip dysplasia.

    2. Avascular necrosis of the femoral head.

    3. Acute traumatic fracture of the femoral head or neck.

    4. Failed previous hip surgery including joint reconstruction, arthrodesis, hemi-arthroplasty, surface replacement arthroplasty, or total hip replacement.

    5. Certain cases of ankyloses.

    Partial hip replacement or hip hemi-arthroplasty is indicated in the following conditions:

    1. Acute fracture of the femoral head or neck that cannot be appropriately reduced and treation.

    2. Fracture dislocation of the hip that cannot be appropriately reduced and treated with internal fixation.

    3. Avascular necrosis of the femoral head.

    4. Non-union of femoral neck fractures.

    5. Certain high subcapital and femoral neck fractures in the elderly.

    6. Degenerative arthritis involving only the femoral head in which the acetabulum does not require replacement.

    7. Pathology involving only the femoral head/neck and/or proximal femur that can be adequately treated by hip hemi-arthroplasty.

    HA coated stems of the Corail Hip system are indicated for cementless use only.

    Device Description

    The DePuy Corail AMT hip stem family are manufactured from forged titanium alloy (Ti6Al4V) and plasma-sprayed with a hydroxyapatite (HA) coating for bone fixation. The stem consists of a wide range of stem neck designs and sizes allowing an accurate anatomical match for each patient. Corail AMT stems are available with or without a collar, with various neck angles, and with various neck offsets.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information based on the provided text, but it's important to note that this document is for a medical device (hip prosthesis) and not an AI/Software as a Medical Device (SaMD). Therefore, many of the requested categories related to AI performance, such as MRMC studies, reader improvements, AI-specific ground truth, and training sets, are not applicable.

    The submission is a 510(k) for the DePuy Corail AMT Hip Prosthesis, seeking substantial equivalence to already marketed predicate devices. The reason for the submission is a change in manufacturing and sterilization facility and a slight modification to packaging. The core device design, principle of operation, and materials remain the same as the predicate devices.


    Acceptance Criteria and Device Performance (for a Hip Prosthesis)

    Since this is a non-AI medical device, the "acceptance criteria" are related to established standards for biocompatibility, sterility, and coating characteristics, rather than diagnostic or analytical performance metrics.

    Acceptance Criterion (Standard/Test)Reported Device Performance (Compliance/Result)
    Biological Safety (per ISO 10993-1) "Biological Evaluation of Medical Devices Part 1: Evaluation and Testing"Demonstrated. (Implied compliance with the standard)
    Sterilization Validation (per AAMI ANSI ISO 11137-1: 2006/(R)2010 and AAMI ANSI ISO 11137-2: 2013)Validated. (Implied compliance with the standard for gamma sterilization)
    Characterization Testing of Hydroxyapatite Coating (per FDA Guidance: "510(k) Information Needed for Hydroxyapatite Coated Orthopedic Implant")Characterized. (Implied compliance with FDA guidance for HA coating properties)
    Substantial Equivalence (Overall Conclusion)The subject device is substantially equivalent to the predicate DePuy Corail AMT Hip Prosthesis products (K042992, K070554, K093736, K123991, K173960).

    Study Details (Not applicable for an AI device in this context)

    Since the provided document is for a physical medical device (hip prosthesis) and not an AI/SaMD, most of the requested fields related to AI performance are not available or applicable.

    1. Sample size used for the test set and the data provenance:

      • Not Applicable (N/A) for AI/SaMD. For this physical device, "test sets" would refer to samples used in engineering and biological testing (e.g., specific hip prosthesis components tested for strength, coating adherence, sterility). The document does not specify the number of units tested for each non-clinical test, nor does it detail data provenance beyond the device's manufacturing origin (Ireland).
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • N/A for AI/SaMD. Ground truth as defined for AI is not relevant here. For a physical medical device, "ground truth" might refer to established physical properties or biological responses, which are determined by standardized testing methods and scientific consensus, not expert consensus on interpretations.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • N/A for AI/SaMD. Adjudication methods are typically used in clinical studies or human-reader performance evaluations, which are not detailed for this non-clinical submission.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • N/A. This is a physical hip prosthesis, not an AI system. No MRMC study was conducted or is relevant.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • N/A. This is a physical hip prosthesis, not an AI algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • N/A for AI/SaMD. For the physical device, the "ground truth" for non-clinical tests would be defined by the specifications of the standards themselves (e.g., a material is "biocompatible" if it passes ISO 10993 tests, a sterilization process is "validated" if it meets the sterility assurance level (SAL) defined by ISO 11137). There is no "pathology" or "outcomes data" specifically mentioned for establishing "ground truth" in this non-clinical submission.
    7. The sample size for the training set:

      • N/A. This is a physical hip prosthesis, not an AI system, so there is no "training set."
    8. How the ground truth for the training set was established:

      • N/A. As there is no training set for an AI system, this question is not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K173960

    Validate with FDA (Live)

    Date Cleared
    2018-09-21

    (267 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K093736

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Total hip replacement or hip arthroplasty is indicated in the following conditions:

    1. A severely painful and/or disabled joint from osteoarthritis, traumatoid arthritis, or congenital hip dysplasia.
    2. Avascular necrosis of the femoral head.
    3. Acute traumatic fracture of the femoral head or neck.
    4. Failed previous hip surgery including joint reconstruction, arthrodesis, hemi-arthroplasty, surface replacement arthroplasty, or total hip replacement.
    5. Certain cases of ankylosis.

    Partial hip replacement or hip hemi-arthroplasty is indicated in the following conditions:

    1. Acute fracture of the femoral head or neck that cannot be appropriately reduced and treated with internal fixation.
    2. Fracture dislocation of the hip that cannot be appropriately reduced and treated with internal fixation.
    3. Avascular necrosis of the femoral head.
    4. Non-union of femoral neck fractures.
    5. Certain high subcapital and femoral neck fractures in the elderly.
    6. Degenerative arthritis involving only the femoral head in which the acetabulum does not require replacement.
    7. Pathology involving only the femoral head/neck and/or proximal femur that can be adequately treated by hip hemi-arthroplasty.

    HA coated stems of the Corail Hip System are indicated for cementless use only.

    Device Description

    The DePuy Corail AMT hip stems are manufactured from forged titanium alloy (Ti6Al4V) and plasma-sprayed with a hydroxyapatite (HA) coating for bone fixation. The stem consists of a wide range of stem neck designs and sizes allowing an accurate anatomical match for each patient. Corail AMT stems are available with or without a collar, with various neck angles, and with various neck offsets. The stems are compatible with both unipolar and bipolar heads intended for hip hemi-arthroplasty and with modular femoral heads intended for total hip arthroplasty.

    AI/ML Overview

    The document describes a 510(k) premarket notification for the DePuy Corail AMT Hip Prosthesis, which is a medical device. The submission aims to demonstrate substantial equivalence to a previously cleared predicate device (DePuy Corail AMT Hip Prosthesis K123991) and includes additional sizes, neck angles, and neck offsets as a line extension.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" in a tabular format for the device's overall performance. Instead, it lists non-clinical tests conducted for determination of substantial equivalence, implying that compliance with these test standards is the performance criteria. The reported performance is that the device passed these tests, indicating it met the requirements of each standard.

    Acceptance Criteria (Test Standard)Reported Device Performance
    Neck fatigue testing in accordance with ISO 7206-6:1992Passed / Compliant
    Distal fatigue testing in accordance with ISO 7206-4:2010Passed / Compliant
    Validation of taper dimensionPassed / Compliant
    Validation of taper to head and neck to head dimensionPassed / Compliant
    Range of motion in accordance with ISO 21535:2007Passed / Compliant
    Pyrogenicity testing using the Bacterial Endotoxin Testing (BET) method as specified in ANSI/AAMI ST72:2011Passed / Compliant
    Hydroxyapatite coating characterization, as specified by FDA Guidance 510(k) Information Needed for Hydroxyapatite Coated Orthopedic Implants, in accordance with ASTM F1160-05:2011, ASTM F1044-05:2011, ASTM F1147-05:2011, ASTM F1926:2010 and ISO 13779-3:2008Passed / Compliant

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document refers to non-clinical (laboratory) testing, not clinical studies with patients. Therefore, the concept of a "test set" in the context of patient data, data provenance, or retrospective/prospective data does not apply here. The sample sizes for the mechanical and material tests (e.g., number of hip stems tested for fatigue) are not specified in the provided summary.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This question pertains to clinical studies and the establishment of ground truth by human experts. Since no clinical tests were conducted for substantial equivalence, this information is not applicable and thus not provided in the document.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    As no clinical tests with patient data were performed, there was no "test set" requiring expert adjudication. This information is not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The device described is a hip prosthesis, a physical implant. It is not an AI/software device that would involve human readers or MRMC studies to assess improvement with AI assistance. Therefore, this information is not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This refers to the performance of an algorithm without human intervention, which is relevant for AI/software devices. The DePuy Corail AMT Hip Prosthesis is a physical medical device, not an algorithm. Therefore, this information is not applicable.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    For the non-clinical tests conducted, the "ground truth" would be the specifications and requirements of the respective ISO, ASTM, and ANSI/AAMI standards. The device's components (neck, distal region, taper, coating) were tested against the performance parameters defined by these engineering and material standards.

    8. The sample size for the training set

    This question is typically relevant for machine learning or AI models, where a "training set" of data is used to develop the algorithm. Since the device is a physical hip prosthesis and its substantial equivalence was determined through non-clinical (mechanical and material) testing, there is no "training set" in this context.

    9. How the ground truth for the training set was established

    As there is no training set for this type of device, this information is not applicable.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1