510(k) Data Aggregation

    K Number
    K221809

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-09-20

    (90 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K042377,K031573

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DePuy Synthes 3.5 mm Intrapelvic Acetabular Plates are indicated for fractures of the acetabulum in adults and adolescents (greater than 12 through 21 years of age) where all growth plates within the acetabulum are fused.

    Device Description

    The DePuy Synthes 3.5 mm Intrapelvic Acetabular System can be used to treat fractures of the acetabulum involving the anterior column, with or without involvement of the posterior column, including the quadrilateral surface (QS). The subject system is comprised of four plate types per anatomic side, left and right, (Large Extended, Small Extended, Large Standard and Small Standard) which are designed to accept the following existing cortex screws: 3.5 mm Cortex Screws, 3.5 mm Pelvic Cortex Screws, 3.5 mm Cortex Screws with low-profile head, 3.5 mm Stardrive Cortex Screws, and 4.5 mm Cortex Screws. The implants are available in a sterile configuration and are offered in Stainless Steel (SSt). In total the system is comprised of eight different plate designs. Each plate configuration consists of a long, slender suprapectineal portion that is intended to be placed along the anterior column, superior to the pelvic brim and a trapezoidal quadrilateral surface portion that is intended to be placed against the medial aspect of the posterior column, overlapping at least a portion of the quadrilateral surface. The suprapectineal portion is divided into anterior and posterior segments that are configured to mimic existing 3.5 mm reconstruction plates and a central segment, to which the quadrilateral surface portion is connected by two connecting bars.

    AI/ML Overview

    This document is a 510(k) summary for the DePuy Synthes 3.5 mm Intrapelvic Acetabular System, a medical device for bone fixation. It describes the device, its intended use, comparison to predicate devices, and performance data.

    Based on the provided document, here's an analysis of the acceptance criteria and study that proves the device meets the criteria:

    The provided text describes a medical device (bone fixation appliance) and its regulatory clearance process, not an AI/software-as-a-medical-device (SaMD) or diagnostic device that would typically have acceptance criteria related to algorithmic performance (e.g., sensitivity, specificity, AUC).

    Therefore, I cannot extract the information required for questions 1, 2, 3, 4, 5, 6, 7, 8, and 9 in the context of an AI/SaMD study. The document focuses on the physical and mechanical properties of a metallic implant and its substantial equivalence to previously cleared implants.

    Let's break down why the requested information isn't present in this specific document:

    • Acceptance Criteria for AI/SaMD: The document does not specify acceptance criteria like sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), or Area Under the Curve (AUC), which are common for AI/SaMD devices. Instead, the acceptance criteria for this structural implant are related to mechanical performance (e.g., strength, durability), biocompatibility, and sterilization.
    • Study Proving Device Meets Acceptance Criteria: The "studies" mentioned are non-clinical performance data for a physical implant, not studies involving algorithms, human readers, or ground truth derived from expert consensus on images.

    However, I can extract the information that is present in the document related to its non-clinical performance and its comparison to predicate devices, which serve as its "proof" of meeting safety and effectiveness for a traditional device clearance.


    Information Extractable from the Provided Document:

    1. A table of acceptance criteria and the reported device performance:

    Since this is a physical medical device (implant) and not a diagnostic AI/SaMD, the "acceptance criteria" are related to mechanical and biocompatibility standards rather than typical AI performance metrics.

    Acceptance Criteria CategorySpecific Test/Performance MeasuredReported Device Performance / Conclusion
    Mechanical PerformanceStatic and Dynamic Physiologic Loading Conditions (worst-case construct)Mechanical performance of the subject device is non-inferior to that of the predicate device.
    BiocompatibilityEndotoxin testing (using LAL test method)Meets the specified endotoxin requirement of 20 EU/device.
    Imaging CompatibilityMagnetic Resonance (MR) compatibility testingEstablished MR Conditional parameters.
    Substantial EquivalenceComparison of Intended Use and Design Features to Predicate DevicesThe device has the same intended use as the predicate device. Differences in technological characteristics do not raise any new issues related to mechanical performance, safety or efficacy.

    2. Sample size used for the test set and the data provenance:

    • Sample Size for Test Set: Not applicable in the context of a "test set" for an AI algorithm. The mechanical and endotoxin tests would have involved a specific number of device samples, but this quantity is not disclosed in the summary.
    • Data Provenance: Not applicable in the context of human data or geographical origin for a physical device's mechanical testing. The testing was conducted internally or by a contracted lab to industry standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):

    • Not applicable. This is not an AI/diagnostic device where expert 'ground truth' is established for a test set of medical images. The "ground truth" for this device's performance is derived from standardized mechanical and biological testing.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    • Not applicable. This concept applies to human reader consensus in image interpretation, not to the testing of a physical implant.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This device is a surgical implant, not an AI-powered diagnostic or assistance tool. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    • For the non-clinical performance data, the "ground truth" is established by adherence to pre-defined engineering standards, mechanical testing protocols (e.g., ASTM standards), and biological safety limits (e.g., endotoxin limits). It's essentially "physical ground truth" based on material science and biomechanics.

    8. The sample size for the training set:

    • Not applicable. There is no AI model or "training set" for this physical device.

    9. How the ground truth for the training set was established:

    • Not applicable. There is no AI model or "training set" for this physical device.
    Ask a Question

    Ask a specific question about this device

    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ARMAR™ / ARTIS™ Small Fragment and Calcaneal Plates & MBOSS™/FIXION™ Screws are indicated for temporary internal fixation and stabilization of osteotomies and fractures, such as:

    • comminuted fractures
    • supracondylar fractures
    • extra-articular fractures
    • fractures in osteopenic bone
    • nonunions
    • malunions
      Smaller-sized ARMAR™ / ARTISTM plates are used for small bones and small fragments of the hands and feet.
      ARMARTM / ARTIS™ Calcaneal plates are indicated for temporary internal fixation and stabilization of osteotomies and fractures of the calcaneous.

    ARMAR™ / ARTIS™ Humerus and Olecranon plates & MBOSSTM/FIXIONT™ Screws are intended for fractures and fracture dislocations, osteotomnies, and non-unions of the distal and proximal humerus, olecranon, and ulna in adult, particularly in osteopenic bone.
    Specifically, distal humerus plates are indicated for intra-articular fractures, comminuted supracondylar fractures, osteotomies, malunions and non-unions of the distalhumerus. Olecranon and Proximal ulna plates are indicated for fractures, osteotomies, malunions and non-unions of the olecranon and proximal ulna.

    ARMARTM / ARTISTM Tibia and Buttress Plates & MBOSS™/FIXION™ Screws are intended for fixation of the ankle in adults. Specifically,

    • Anterolateral Distal Tibia Plates are intended for fixation of osteotomies, fractures, nonunions, malunions, and replantations of bones and bone fragments of the diaphyseal and metaphyseal regions of the distal tibia.
    • Medial Distal and Proximal Tibia Plates are intended for fixation of osteotomies, fractures, nonunions, malunions, and replantations of bones and bone fragments of the diaphyseal and metaphyseal regions of the distal tibia,
    • L Buttress and T Buttress Plates are intended to buttress partial articular fractures and bone fragments of the distal tibia, and
    • Proximal Lateral Tibia Plates are intended for fixation of osteotomies, fractures, nonunions, malunions, and replantations of bones and bone fragments of the diaphyseal and metaphyseal regions of the distal tibia, a Distal Tibia T Plates and Distal Tibia L Plates are intended to buttress partial articular fractures and bone fragments of the distal tibia.

    ARMAR™ / ARTISTM 2.4mm Plates & MBOSS™/FIXION™ Screws are intended for Fixation of complex intra- and extra-articular fractures and osteotomnies of the distal radius and other small bones in adults.

    ARMARTM / ARTISTM Clavical Hook Plate & MBOSS™/FIXION™ Screws is intended for fixation of lateral clavicle fractures and dislocations of the acromioclavicular joint.

    ARMARTM / ARTISTM Metaphyseal Plate & MBOSS™/FIXION™ Screws indicated for fractures, osteotomies, and non-unions of the radius and other small bones. Additionally, the Metaphyseal Plate is intended for pelvic and acetabular reconstructive surgery and fracture fixation of the distal humerus, clavicle, and scapula.

    ARMARTM / ARTISTM Calcaneal Plate & MBOSS™/FIXION™ Screws is intended for fixation of complex extra-articular and intra-articular fractures and osteotomies of the calcaneus.

    Device Description

    The Meril Healthcare Trauma System utilizes screws and plates of various lengths and designs to accommodate a variety of patient anatomies. The Trauma System utilizes medical grade stainless steel and titanium. Trauma System implant are provided clean and non-sterile with instructions for steam sterilization. The instruments are provided non-sterile and are reusable. The implants are provided nonsterile and are single use only.

    AI/ML Overview

    This document is a 510(k) premarket notification decision letter from the FDA regarding a medical device, specifically bone plates and screws. It does not contain information about an AI/ML device, AI acceptance criteria, or a study proving an AI device meets acceptance criteria.

    Therefore, I cannot extract the requested information regarding AI device performance, acceptance criteria, sample sizes, expert ground truth, MRMC studies, or training/test set details from this document. The document describes the substantial equivalence of bone fixation appliances to existing predicate devices based on technological characteristics and mechanical performance data (e.g., static four-point bending, dynamic four-point bending, static torsion, static axial pullout).

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1