Found 9 results

510(k) Data Aggregation

    K Number
    K260551

    Validate with FDA (Live)

    Date Cleared
    2026-03-20

    (30 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K090105

    Validate with FDA (Live)

    Device Name
    LUPOTEK KCT
    Date Cleared
    2010-12-30

    (714 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K083729

    Validate with FDA (Live)

    Date Cleared
    2009-05-08

    (143 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    HEMOCLOT Quanti VL is an in vitro diagnostic test for the quantitative determination of Factor V Leiden (FVL) activity in human citrated plasma, using automated or manual methods, by its resistance to the action of Activated Protein C ( APC).

    Patients with the Factor V-L (mutalion R506Q), are exposed to an increased thrombotic risk.

    Biophen V-L CAL (undiluted), at defined Factor V-Leiden (FV-L) concentrations, for the callibration of Factor V-Leiden aclivity on human plasma, using the Hemoclot Quanti V-L kit.

    Factor V-L Cafibrator, pre diluted (1:20) human plasmas. at defined Factor V-Leiden (FV-L) concentrations, for the calibration of Factor V-L activity on human plasma using Hemoclot Quanti V-L Kit.

    Biophen Act PC-r Control Plasma contains human plasma, presenting an Activated Protein C Resistance (APC-R) is used as quality control plasma for the testing of Activated Protein C resistance (APC-R) on human plasma using Hemoclot Quarti V-L Kit.

    (Updated) BIOPHEN Normal Control Plasma is a set of 12 vials of normal citrated human plasma for the quality control of some coagulation factors. The following table shows parameters, which are measured using assays from HYPHEN BioMed or from other manufacturers, and according to the package inserts:

    AssaysReagentsManufacturersReference
    ATIIIBiophen ATIIIHyphen Biomed221102/221105
    Protein CBiophen Protein CHyphen Biomed221202/221205
    aPC resistance(FV Leiden)Hemoclot Quanti V-LHyphen BiomedCK065K
    LupusAnticoagulantDVVtest®/DVVconfirm®AmericanDiagnostica810/815/815L

    DVVtest, DVVconfirm are registered trademarks from American Diagnostica, Inc.

    The BIOPHEN Normal Control Plasma is tested for the absence of Lupus Anticoagulant and can be used as a negative control for this investigation. This control plasma is also tested for the absence of Activated Protein C resistance (Act PC-7). When the APTT is performed with or without Activated Protein C (APC) the ratio obtained (APTT + APC/APTT) is ≥2.00.

    Device Description
      1. HEMOCLOT Quanti V-L is an in vitro diagnostic test kit containing 3 vials of each of the following 2 lyophilized reagents:
        R1: Reagent 1: Clotting mixture containing human Fibrinogen, human prothrombin, Protein S at a constant concentration, optimized for the assay, and human Activated Protein C, lyophilized. It also contains a heparin neutralizing substance. Each vial is to be reconstituted with exactly 2 ml of distilled water.

    R2: Reagent 2: Purified Human Factor Xa, containing rabbit brain phospholipds (cephalin), lyophilized. Each vial is to be reconstituted with exactly 1 ml of distilled water.

    Calibrators and controls to be used with the test kit are supplied separately. The following calibrators and control are included in this submission:

      1. Factor V-L Calibrator is a calibrator kit containing 3 vials each of 1.0 ml prediluted human plasma (1:20), freeze dried, at 4 different concentrations of FV-L, to cover the assay range, from 10% to 100%. Each vial is restored with 1.0 ml Owren Koller type buffer.
      1. BIOPHEN V-L CAL (Undiluted) is a calibrator kit containing 3 vials each of 0.5 ml undiluted human plasma, freeze dried, at 3 different concentrations of FV-L, to cover the assay range, from about 10% to 100%. Each vial is restored with 0.5 ml distilled water.
    • BIOPHEN Act PC-r Control Plasma is a controls kit containing 12 vials of 0.5 ml human 4. plasma, presenting an Activated Protein C Resistance (APC-R), citrated and Iyophilized. Each vial is to be reconstituted with exactly 0.5 ml of distilled water.
    • BIOPHEN Normal Control Plasma manufactured by Hyphen-Biomed, is also used with the test kit and is currently marketed in the US under 510(k) # K043451, It is a controls kit containing 12 vials of 1.0 ml of normal citrated human plasma, lyophilized. Each vial is to be reconstituted with exactly 1.0 ml of distilled water.
    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the HEMOCLOT Quanti V-L device:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state formal "acceptance criteria" in terms of numerical thresholds for sensitivity, specificity, or agreement. Instead, it demonstrates consistency with a predicate device and molecular biology results. The performance is presented as direct agreement percentages.

    Performance MetricAcceptance Criteria (Implied/Demonstrated)Reported Device Performance (HEMOCLOT Quanti V-L)
    Agreement with Predicate Device (COATEST APCr)To show "good consistency"94.18%
    Co-positivity with Predicate DeviceTo show "good consistency"97.30%
    Co-negativity with Predicate DeviceTo show "good consistency"89.74%
    Agreement with Molecular BiologyTo show "good consistency" (ideally 100%)100.00%
    Co-positivity with Molecular BiologyTo show "good consistency" (ideally 100%)100.00%
    Co-negativity with Molecular BiologyTo show "good consistency" (ideally 100%)100.00%
    Intra-Assay CV (100% FVL plasma)To demonstrate reproducibilityCT (sec): 4.4%, %FVL: 5.9%
    Inter-Assay CV (100% FVL plasma)To demonstrate reproducibilityCT (sec): 2.2%, %FVL: 3.3%
    Intra-Assay CV (50% FVL plasma)To demonstrate reproducibilityCT (sec): 4.2%, %FVL: 8.2%
    Inter-Assay CV (50% FVL plasma)To demonstrate reproducibilityCT (sec): 2.3%, %FVL: 4.7%
    Inter-Assay CV (25% FVL plasma, KC10)To demonstrate reproducibilityOn CT (sec): 7.3%, On %FVL: 17.4%
    Inter-Assay CV (10% FVL plasma, KC10)To demonstrate reproducibilityOn CT (sec): 6%, On %FVL: 29.1%
    Inter-Assay CV (25% FVL plasma, STAR)To demonstrate reproducibilityOn CT (sec): 5.2%, On %FVL: 13.1%
    Inter-Assay CV (10% FVL plasma, STAR)To demonstrate reproducibilityOn CT (sec): 5.6%, On %FVL: 23.7%
    Inter-Assay CV (25% FVL plasma, WATER BATH)To demonstrate reproducibilityOn CT (sec): 2.7%, On %FVL: 10.0%
    Inter-Assay CV (10% FVL plasma, WATER BATH)To demonstrate reproducibilityOn CT (sec): 5.6%, On %FVL: 15.2%

    2. Sample Size Used for the Test Set and Data Provenance

    • Comparison with Predicate Device (COATEST APCr):
      • Sample Size: 189 total samples (108 Normal, 70 Abnormal, 10 inconclusive/borderline based on detailed table analysis: 108 Normal + 1 Abnormal + 2 Inconclusive=111 from Predicate Normal; 7 Abnormal + 70 Abnormal + 1 Inconclusive = 78 from Predicate Abnormal). However, the "Sample Size" row explicitly states 189 for the overall comparison.
      • Data Provenance: "combined from 4 studies (2 in US, 2 in Europe)." This indicates a retrospective or prospective collection across multiple sites. The specific nature (retrospective/prospective) is not explicitly stated, but clinical studies often involve a mix.
    • Comparison with Molecular Biology:
      • Sample Size: 21 total samples (15 Normal, 6 Abnormal).
      • Data Provenance: Not explicitly stated, but implied to be part of the overall validation studies.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not mention the use of "experts" for establishing ground truth in the traditional sense of clinical readings.

    • For the comparison with the predicate device, the "ground truth" for the test set was the classification (Normal/Abnormal) provided by the COATEST APCr kit. This is a laboratory diagnostic assay, not an expert human interpretation.
    • For the comparison with Molecular Biology, the "ground truth" was the molecular biology result itself (indicating presence or absence of the R506Q mutation). This is an objective genetic test, not subject to expert interpretation.

    4. Adjudication Method for the Test Set

    Not applicable. As the ground truth was established by another diagnostic assay (COATEST APCr) or molecular biology, there was no human adjudication process involved. The results were compared against these established methods.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No. This study is for an in vitro diagnostic (IVD) assay, which measures an analytical marker in human plasma. It does not involve human readers interpreting images or data, so an MRMC study comparing human readers with and without AI assistance is not relevant or applicable here.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    Yes, this entire study represents the standalone performance of the HEMOCLOT Quanti V-L device. It evaluates the device's ability to classify samples as Normal, Abnormal, or Inconclusive based on its own measurements, compared against a predicate device and a molecular biology reference. There is no human interpretation involved in the direct result generation of the HEMOCLOT Quanti V-L assay itself.

    7. The Type of Ground Truth Used

    • Comparison with Predicate Device: The ground truth was the result obtained from the COATEST APC Resistance V (K963111) predicate device.
    • Comparison with Molecular Biology: The ground truth was the molecular biology result for the Factor V Leiden (mutation R506Q). This is pathology/genetic testing data, considered a highly objective measure for the presence of the mutation.

    8. The Sample Size for the Training Set

    The document doesn't explicitly mention a separate "training set" for the HEMOCLOT Quanti V-L assay in the context of machine learning or AI. For IVD kits like this, the "training" typically refers to the optimization and validation performed by the manufacturer during product development, using various samples to establish assay parameters, linearity, sensitivity, specificity, and reproducibility. The performance data presented here is the validation or "test" set used to demonstrate substantial equivalence.

    9. How the Ground Truth for the Training Set Was Established

    As there's no mention of a traditional machine learning "training set" with separate ground truth establishment, this question is not fully applicable in the context of this document. For IVD development, the "ground truth" for calibrators, controls, and method development would have been established through highly characterized reference materials, potentially confirmed by molecular methods or established clinical diagnoses of FVL status.

    Ask a Question

    Ask a specific question about this device

    K Number
    K060284

    Validate with FDA (Live)

    Date Cleared
    2006-05-10

    (96 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    cryocheck Clot APCR is a clotting assay intended to screen for resistance to activated protein C in citrated human plasma from individuals with the factor V Leiden mutation.

    Device Description

    cryocheck Clot APCR consists of:

    • 5 x 2.0 mL Activator Reagent (APC-AR) .
    • 5 x 4.0 mL Russell's Viper Venom Reagent (APC-RV)
    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the cryocheck™ Clot APCR™ device, based on the provided 510(k) summary:

    1. Acceptance Criteria and Reported Device Performance

    The document does not explicitly state pre-defined acceptance criteria in terms of numerical thresholds for sensitivity, specificity, or correlation. Instead, it frames the acceptance criteria implicitly as "comparable precision," "identical results when challenged with interfering substances and factor deficiencies," and "identical sensitivity and specificity" when compared to the predicate device. The primary performance metric reported is a correlation coefficient.

    Acceptance Criteria (Implicit)Reported Device Performance (cryocheck Clot APCR)
    Comparable precision to predicate device (GradiLeiden V)Showed comparable precision to GradiLeiden V.
    Identical results with interfering substances/factor deficiencies as predicateDemonstrated identical results when challenged with interfering substances and factor deficiencies.
    Identical sensitivity to predicate device (GradiLeiden V)Exhibited identical sensitivity to GradiLeiden V.
    Identical specificity to predicate device (GradiLeiden V)Exhibited identical specificity to GradiLeiden V.
    Strong correlation with predicate deviceA correlation of R = 0.960 was obtained (with GradiLeiden V).

    2. Sample Size and Data Provenance

    • Sample Size for Test Set: 207 clinical samples.
    • Data Provenance: The document states that clinical tests were performed "at Precision BioLogic and a US university hospital-based clinical coagulation laboratory." This indicates the data is prospective clinical data collected from human subjects (patients). The clinical samples were from "the target population for the assay."

    3. Number of Experts and Their Qualifications for Ground Truth

    The document does not specify the number of experts used to establish ground truth or their qualifications. The comparison is made against a predicate device, implies that the predicate device's results are considered the reference standard, rather than independently established expert ground truth.

    4. Adjudication Method for the Test Set

    The document does not describe any specific adjudication method for the test set. The comparison appears to be a direct one-to-one comparison of results between the new device and the predicate device for each sample.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, an MRMC comparative effectiveness study was not done. The study focuses on comparing the new device's performance to a predicate device, not on assessing human reader performance with or without AI assistance.

    6. Standalone (Algorithm Only) Performance Study

    Yes, the study is a standalone performance study. The device itself is an in vitro diagnostic (IVD) assay that provides a result (clotting time ratio). The "performance" being evaluated is the accuracy and reliability of this assay in classifying samples compared to the predicate device. There is no human-in-the-loop component described for the operation of this specific device or its interpretation in the context of the study.

    7. Type of Ground Truth Used

    The "ground truth" for the test set was essentially the results obtained from the predicate device (GradiLeiden V). The study compared the cryocheck Clot APCR's performance to the GradiLeiden V results across the 207 clinical samples.

    8. Sample Size for the Training Set

    The document does not explicitly mention a "training set" or its size. Since this is an in vitro diagnostic assay rather than an AI/machine learning algorithm, the concept of a distinct training set in the typical machine learning sense does not apply. The development of the assay would involve R&D and validation, but not a "training set" in the computational context.

    9. How Ground Truth for Training Set Was Established

    As noted above, the concept of a training set as it applies to AI/ML is not relevant here. The "ground truth" for the development and validation of such an assay would typically be established through robust laboratory methods, perhaps using known Factor V Leiden positive and negative samples, and comparison to established clinical diagnostic methods, but specific details of this process for assay development are not provided in the 510(k) summary.

    Ask a Question

    Ask a specific question about this device

    K Number
    K042762

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2004-12-22

    (78 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is a plasma based functional IVD assay for the decemination of resistance to activated protein C caused by the factor V Leiden mulation (EV-QEAC) vated protein C castin bascu for the december (FV: CS00) on automation of resistance to activated protein C caused by the factor V Leiden mulation (FV: (SOO) on automated a the super of of C backed by the factor v Leiden mulation (FV:Q506) on automated and

    Device Description

    Pefakit® APC-R Factor V Leiden is an in vitro diagnostic test kit containing 3 vials each of the following 4 lyophilized reagents: R1: APC / RVV-V (+APC) Reagent (APC, RVV-V, Polybrene, Hepes, BSA) R2: APC / RVV-V (-APC) Reagent (RVV-V, Polybrene, Hepes, BSA) R3: PTA Reagent (Prothrombin Activator, EDTA, Hepes, BSA) R4: Dilution Plasma (Human Plasma, processed) For Quality Assurance/Quality Control the corresponding control kit 'Pefakit® APC-R Factor V Leiden Controls' has to be used. It contains 3 vials each of the following 2 lyophilized control plasmas: C1: pooled human plasma from donors confirmed to be normal wild-type by FV Leiden PCR testing C2: pooled human plasma from donors confirmed to be heterozygous by FV Leiden PCR testing

    AI/ML Overview

    This 510(k) summary describes the Pefakit® APC-R Factor V Leiden, an in vitro diagnostic test kit used to detect resistance to activated protein C caused by the Factor V Leiden mutation. The summary details the device's technological characteristics, non-clinical and clinical study results, and its substantial equivalence to a predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implied by the direct comparison to the predicate device and the claims of "superior" performance in certain aspects. The submission doesn't explicitly state quantitative acceptance criteria targets but rather compares performance to the predicate device and internal standards.

    Performance MetricAcceptance Criteria (Implied)Reported Device Performance
    PrecisionComparable to predicate device; CV < 6%Within-series and Day-to-day precision: Overall CV < 6% (in-house testing). Side-by-side comparison with predicate on STA® R analyzer showed equivalent precision.
    Diagnostic SensitivityHigh; comparable or superior to predicate deviceIn-house testing: 100% diagnostic sensitivity. Clinical studies: Superior diagnostic sensitivity compared to the predicate device.
    Diagnostic SpecificityHigh; comparable or superior to predicate deviceIn-house testing: 100% diagnostic specificity. Clinical studies: Superior diagnostic specificity compared to the predicate device.
    Resolution PowerDiscrimination between carriers and non-carriers, heterozygous, and homozygous mutant carriersHigh power of resolution not only between carriers and non-carriers of the FV Leiden mutation but also between heterozygous and homozygous carriers.
    Interference (Lupus Anticoagulants - LA)Insensitivity to LA (superior to predicate device)In-house testing: No influence of LA on the discrimination power. CIMCLD/AKH study: LA clearly visible with predicate, but no influence on Pefakit® assay. DUMC study: LA had no influence on the outcome of the Pefakit® assay. Clearly superior to the predicate device in this respect.
    Interference (High Factor V Deficiency (< 50%) & Aprotinin, Protamine, DTI)Acknowledged interference, similar to predicate deviceInterferes with the test, similar to the predicate device.
    Interference (Oral Coagulant Treatment)No influence, similar to predicate deviceClinical studies: Both tests (new device and predicate) were not influenced by oral coagulant treatment of the patients.
    Stability (On-board reconstituted reagents)At least 24 hours; equivalent or superior to predicateAt least 24h.
    Stability (Kit and reagents, unopened)At least 2 years when stored at 2-8°CReal time long-term stability studies ongoing; currently proved stable for 2 years when stored unopened at 2-8°C.
    Batch-to-batch VariabilityVery lowDemonstrated to be very low across three pilot batches (100, 250, and 1000 device boxes) for both the basic device and the control device.

    2. Sample Size Used for the Test Set and Data Provenance

    The exact sample sizes for the test sets in the clinical studies are not explicitly stated in this 510(k) summary. It mentions "clinical studies at two haematology laboratories of big central Hospitals in Europe (CIMCLD/AKH, Vienna) and the USA (Duke University Medical Center/DUMC, Durham/Raleigh NC)."

    Data Provenance:

    • Country of Origin: Europe (Vienna, Austria) and USA (Durham/Raleigh NC, Duke University Medical Center).
    • Retrospective or Prospective: The summary does not explicitly state if the studies were retrospective or prospective, but the phrasing "In these studies both tests showed to have comparable precision..." and "For all other possible interference factors included in these studies no correlation could be found between patient parameters and test outcome" suggests a prospective collection or at least a controlled comparison of samples within the designated studies.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The summary does not specify the number of experts or their qualifications used to establish the ground truth for the clinical study test sets. It refers to "donors confirmed to be normal wild-type by FV Leiden PCR testing" and "donors confirmed to be heterozygous by FV Leiden PCR testing" for the control plasmas C1 and C2, respectively. This implies that PCR testing was the method of establishing the true genotype, but not who performed or confirmed these results.

    4. Adjudication Method for the Test Set

    The summary does not describe any adjudication method for the test set. The ground truth for the control plasmas was established by PCR. For the clinical studies, it is implied that the assessment of diagnostic sensitivity and specificity was based on the underlying Factor V Leiden status of the patients, likely confirmed by a gold standard method.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was Done, If So, What was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This device is an in vitro diagnostic (IVD) test kit for functional assay, not an AI-powered diagnostic imaging or interpretation tool. Therefore, a multi-reader multi-case (MRMC) comparative effectiveness study of human readers with vs. without AI assistance is not applicable to this type of device. The study compared the performance of the new IVD device against a predicate IVD device.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was Done

    The device is an IVD test kit, designed to be run on automated or semi-automated blood coagulation analyzers. Its performance is inherent to the chemical reactions and detection methods of the reagents. Therefore, the "standalone performance" is its intended use, without human interpretation of the raw chemical reaction, but rather the interpretation of the results provided by the machine. The summary reports its standalone performance in terms of precision, sensitivity, specificity, and resistance to interferences.

    7. The Type of Ground Truth Used

    The primary ground truth mentioned for the control plasmas is molecular pathology, specifically "FV Leiden PCR testing." For the broader clinical studies, it is strongly implied that the ground truth for the Factor V Leiden mutation status of the patient samples was also established through molecular diagnostics (e.g., PCR or similar genotyping methods), given that the device aims to detect resistance caused by the Factor V Leiden mutation.

    8. The Sample Size for the Training Set

    The summary does not explicitly mention a "training set" as this is not an AI/ML device in the modern sense. The development of the assay would have involved internal testing and optimization (potentially using various sample sizes for method development), but the submission focuses on the validation studies, not the development phase. The "in-house testing" for precision and diagnostic performance can be seen as part of the internal validation and optimization, but a distinct "training set" is not delineated.

    9. How the Ground Truth for the Training Set Was Established

    As there is no explicitly defined "training set" in the context of an AI/ML device, this question is not directly applicable. However, for the development and in-house validation of the assay, the ground truth for establishing performance metrics (like sensitivity and specificity) would have been established through a reference method, most likely molecular genotyping (e.g., PCR) for the Factor V Leiden mutation. The control plasmas (C1 and C2) are described as confirmed by FV Leiden PCR testing, indicating this was the gold standard used.

    Ask a Question

    Ask a specific question about this device

    K Number
    K033471

    Validate with FDA (Live)

    Date Cleared
    2004-02-04

    (93 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Phospholin ES Activated Partial Thromboplastin Time reagent is a liquid activated reagent with phospholipids derived from soybean lecithin for use in the determination of Activated Partial Thromboplastin Time (APTT) and related coagulation procedures. Phospholin ES is to be used as an APTT reagent (qualitative assay) on patient plasma for the routine screening in the general patient population for deficiencies involving the intrinsic pathway of coagulation. Phospholin ES is sensitive to lupus-like inhibitors.

    Device Description

    R2 Diagnostics Phospholin ES is a liquid reagent containing ellagic acid as the activator and phospholipids derived from soybean lecithin. The reagent also contains buffer and preservatives. Phospholin ES is an in vitro diagnostic reagent intended for use for the performance of the activated partial thromboplastin time two-stage test (APTT) and related coagulation factor assays. Phospholin ES is sensitive to lupus anticoagulants. Phospholin ES as with any APTT test requires the addition on 0.02-0.025M Calcium Chloride to perform the assay.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the R2 Diagnostics Phospholin ES device, based on the provided 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document frames its "acceptance criteria" and "device performance" in terms of substantial equivalence to a predicate device. The performance criteria are primarily correlation coefficients and precision for various sample types.

    Acceptance Criterion (Type)Predicate Device PerformanceProposed Device Performance (Reported)
    Correlation: Normal & Abnormal Patients (Photo-optical)N/A (implied by predicate's established performance)R = 0.92, Slope = 0.864
    Correlation: Normal & Abnormal Patients (Mechanical)N/AR = 0.93, Slope = 1.09
    Correlation: Lupus Anticoagulant Samples (Photo-optical)N/AR = 0.94, Slope = 0.866
    Correlation: Lupus Anticoagulant Samples (Mechanical)N/AR = 0.99, Slope = 0.627
    Precision: Within-run CV< 3% (Reported in manufacturer's directional insert)< 3%
    Precision: Between-run CV< 3% (Reported in manufacturer's directional insert)< 3%

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: The document does not explicitly state the exact number of samples used in the correlation studies. It mentions "normal and abnormal patients, as well as samples from patients positive for lupus anticoagulants."
    • Data Provenance: Not specified, but likely retrospective convenience sampling given the nature of the study as a comparison to an existing predicate device. The country of origin is not mentioned.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    This information is not provided. For an in vitro diagnostic device like Phospholin ES, the "ground truth" for the test set would typically be the results obtained from the predicate device itself, which is already an accepted diagnostic method. The document relies on a comparison between the new device and the predicate device, rather than an independent "expert ground truth" as might be seen in imaging or pathology studies.

    4. Adjudication Method for the Test Set

    Not applicable. The study is a direct comparison of results between two in vitro diagnostic reagents rather than human interpretation with potential for disagreement requiring adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. This is an in vitro diagnostic reagent study, not an imaging or interpretation study involving multiple human readers.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, this is an in vitro diagnostic reagent. Its performance is evaluated on its own, producing a quantitative result (APTT time) from a biological sample. Human interpretation is subsequent to the reagent's performance in the laboratory instrument.

    7. The Type of Ground Truth Used

    The "ground truth" in this context is the performance of the predicate device (Dade Actin FSL and Stago Calcium Chloride). The study aimed to show that Phospholin ES's results correlate highly with and are interchangeable with those obtained from the predicate device.

    8. The Sample Size for the Training Set

    Not applicable. This type of in vitro diagnostic reagent development does not typically involve a "training set" in the machine learning sense. The formulation of the reagent is based on chemical and biological principles, and its performance is validated against established methods.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As noted above, there isn't a "training set" in the conventional sense for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K992456

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1999-12-21

    (151 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    GradiLeiden V is a simple functional clotting test system intended for screening of resistance to Activated Protein C in plasma from individuals with the Factor V (Leiden) defect. It can also be performed on plasma from patients on stabilized oral anticoagulant or heparin therapy.

    Device Description

    The GradiLeiden V Test is a lyophilized paired reagent containing 5 vials of whole diluted Agkistrodon contortrix venom and 5 vials of phospholipid rich Russell's Viper Venom time reagent.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the GradiLeiden V Test, based on the provided 510(k) summary:

    Acceptance Criteria and Device Performance

    Acceptance CriteriaReported Device Performance
    Sensitivity100%
    Specificity98.8%
    Within Run Precision for FVL+ plasma1.1%
    Within Run Precision for normal plasma1.9%
    Within Run Precision at cutoff0.9%
    Total Precision for FVL+ plasma8.9%
    Total Precision for borderline normal plasma1.6%
    Total Precision for normal plasma5.6%
    Identifies Factor V Leiden status correctly163/164 individuals
    Identifies Oral Anticoagulated plasmas35/36
    Identifies heparinized plasmas21/21
    Identifies Lupus Anticoagulant positive plasmas12/12

    Study Details

    1. Sample size used for the test set and the data provenance:

      • Test Set Size: 164 individuals (This number includes 35 oral anticoagulated plasmas, 21 heparinized plasmas, and 12 Lupus Anticoagulant positive plasmas, alongside other samples).
      • Data Provenance: Not explicitly stated (e.g., country of origin). The submission is from Australia, suggesting the data may originate from there or an international collaboration. It describes the comparison as "GradiLeiden V was compared against the predicate device in a series of clotting assays," implying a prospective approach for the comparison study, but the source of the patient samples (retrospective/prospective collection) is not specified.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Number of Experts: Not specified.
      • Qualifications of Experts: Not specified. The ground truth was established by "DNA analysis," which implies a laboratory-based, molecular diagnostic method rather than expert interpretation of a diagnostic image or clinical presentation.
    3. Adjudication method for the test set:

      • Not applicable as the ground truth was based on DNA analysis, not expert consensus requiring adjudication.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This is not an AI-based diagnostic device; it's a laboratory clotting test. The comparison was between two laboratory tests (GradiLeiden V and Coatest APC Resistance V) with ground truth established by DNA analysis.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Yes, a standalone performance was done for the GradiLeiden V device. Its performance was evaluated against DNA analysis as the ground truth.
    6. The type of ground truth used:

      • DNA analysis (specifically mentioned: "all results confirmed by DNA analysis"). This is a highly accurate, molecular diagnostic method for determining Factor V Leiden status.
    7. The sample size for the training set:

      • Not explicitly stated. The document focuses on the test set used for validation. The device's cut-off of 1.57 was "obtained by ROC analysis," which implies a dataset was used to determine this threshold, but whether this constitutes a distinct "training set" in a machine learning sense, or if it was part of the overall validation process, is not detailed.
    8. How the ground truth for the training set was established:

      • Assuming the "training set" (or data used for ROC analysis) was drawn from similar sources as the test set, the ground truth would have been established by DNA analysis.
    Ask a Question

    Ask a specific question about this device

    K Number
    K982062

    Validate with FDA (Live)

    Date Cleared
    1999-01-13

    (212 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cryo✓Check™ PNP Platelet Lysate is intended for use in the Platelet Neutralization Procedure (PNP) which is useful in detecting the presence of lupus anticoagulants (LA) in human plasma.

    Device Description

    Cryo Check™ PNP Platelet Lysate is prepared from human platelets obtained from normal healthy donors. The platelets are collected, washed, and resuspended in buffer and then frozen and thawed to yield a suspension of ruptured platelet membranes. This suspension is aliquoted into cryovials and stored frozen.

    AI/ML Overview

    The provided text describes the performance of the Cryo✓Check™ PNP Platelet Lysate, but it does not explicitly state acceptance criteria in a formal, quantifiable manner. Instead, the conclusions of the non-clinical performance data serve as the de facto acceptance criteria, implying that the device's performance should be "comparable," "consistent," and "stable" to that of the predicate device or under various conditions.

    Here's an attempt to structure the information based on the provided text, interpreting the conclusions as the performance goals the device met:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Inferred from Conclusions)Reported Device Performance
    Criterion 1: Comparable Specificity to Predicate Device for Normal and Lupus Anticoagulant Positive Patient Samples (Implicit: Results for normal samples should show minimal correction, and results for lupus samples should show significant, comparable correction to the predicate device.)Compared to BIO/DATA Platelet Extract Reagent (Predicate Device): Normal Plasmas (n=5): Cryo✓Check™ PNP Platelet Lysate Mean Correction: 0.34 sec BIO/DATA Platelet Extract Mean Correction: -0.6 sec Correlation Coefficient: -0.510 (attributed to short correction times, not defect) Lupus Plasmas (n=10): Cryo✓Check™ PNP Platelet Lysate Mean Correction: 15.72 sec BIO/DATA Platelet Extract Mean Correction: 14.56 sec Correlation Coefficient: 0.987 Conclusion: "Cryo✓Check™ PNP Platelet Lysate demonstrated comparable specificity to the predicate device when tested against normal plasma and lupus anticoagulant positive patient plasmas when used in a platelet neutralization procedure."
    Criterion 2: Consistent Vial-to-Vial Reactivity Over 8-hour Period (Implicit: Low variability in correction times for both normal and lupus plasmas across multiple vials over 8 hours.)8 Hour Open Vial Stability Study (MLA 900 C Analyzer): Normal Plasma (5 vials): Mean Correction (Time=0 hrs): 4.7 sec (SD 0.292) Mean Correction (Time=8 hrs): 3.84 sec (SD 0.358) Lupus Plasma (5 vials): Mean Correction (Time=0 hrs): 12.6 sec (SD 1.39) Mean Correction (Time=8 hrs): 11.0 sec (SD 0.358) Conclusion: "PNP procedures using Cryo✓Check™ PNP Platelet Lysate exhibited consistent vial to vial reactivity over an 8-hour period."
    Criterion 3: Stability on Automated Coagulation Analyzer for Greater Than 8 Hours (Implicit: Neutralization results should remain consistent over at least 8 hours when run on an automated analyzer.)14 Hour On-Board Stability Study (MDA 180 Analyzer): Normal Control (CCN-10): Neutralization (0 min): -4.6 sec Neutralization (8 hr): -4.4 sec Neutralization (14 hr): -3.9 sec Mean Neutralization (0-14 hr): -4.14 sec (Std. Dev. 0.291) Lupus Positive Control (CCLP-10): Neutralization (0 min): 17.3 sec Neutralization (8 hr): 17.5 sec Neutralization (14 hr): 18.9 sec Mean Neutralization (0-14 hr): 17.2 sec (Std. Dev. 0.819) "in-house" positive control (HRF): Neutralization (0 min): 28.3 sec Neutralization (8 hr): 29.9 sec Neutralization (14 hr): 31.2 sec Mean Neutralization (0-14 hr): 29.8 sec (Std. Dev. 1.055) Conclusion: "Cryo✓Check™ PNP Platelet Lysate is stable for greater than 8 hours on an MDA 180 automated coagulation analyzer."
    Criterion 4: Consistent Results Across Different Automated Coagulation Systems (Implicit: Neutralization results for normal patient samples should be comparable, even if absolute values differ, between different types of coagulation analyzers.)Comparison of Reactivity on 2 Automated Coagulation Analyzers (25 Normal Patient Samples): MDA 180 (Photo-Optical Clot Detection): Mean neutralization: -2.084 sec (Std dev 1.051) Stago ST4 (Mechanical Clot Detection): Mean neutralization: -3.664 sec (Std dev 1.151) Conclusion: "Cryo✓Check™ PNP Platelet Lysate yielded consistent results when used on 2 different automated coagulation systems." (Note: While mean values differ, the 'consistency' likely refers to the overall behavior and relative neutrality shown for normal samples on both systems.)

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Test 1 (PNP Comparison to Predicate Device):

      • Sample Size: 5 normal plasma samples, 10 lupus plasma samples.
      • Data Provenance: Not explicitly stated, but clinical samples are implied ("normal and known lupus anticoagulant positive patient samples"). Likely in vitro/laboratory-based.
    • Test 2 (8 Hour Open Vial Stability):

      • Sample Size: 5 vials of Cryo✓Check™ PNP Platelet Lysate paired with one "Normal Plasma: Cryo✓Check™ Normal (CCN)" and one "Lupus Plasma: Cryo✓Check™ Lupus (CCLP)".
      • Data Provenance: In vitro, using commercially available control plasmas.
    • Test 3 (14 Hour On-Board Stability):

      • Sample Size: One lot of Cryo✓Check™ PNP Platelet Lysate tested with three control plasmas (Normal, Lupus Positive, HRF "in-house" positive control) over 14 time points.
      • Data Provenance: In vitro, using commercially available and "in-house" control plasmas.
    • Test 4 (Coagulation Analyzer Comparison):

      • Sample Size: 25 normal patient samples.
      • Data Provenance: Not explicitly stated, but "Normal Patient Samples" implies retrospective or prospective collection from patients. Likely from Canada, given the submitter's location.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    Not applicable. This device is a diagnostic reagent, and the 'ground truth' in these studies is established by the clinical classification of the plasma samples (normal vs. lupus anticoagulant positive) and measurement against established laboratory methods (APTT, Platelet Neutralization Procedure). No human expert interpretation of images or other subjective data is involved. The ground truth for plasma samples (e.g., "Lupus Plasma") would have been established through prior diagnostic testing, but the details of those classifications are not provided.

    4. Adjudication Method for the Test Set

    Not applicable. As this involves laboratory measurements with quantitative outputs (seconds for APTT and correction), not subjective interpretation, an adjudication method for a test set is not relevant in the way it would be for, e.g., image analysis by multiple readers.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is typically used for diagnostic imaging devices where human readers interpret cases with or without AI assistance. The described studies are non-clinical performance evaluations of a laboratory reagent.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, the studies described are standalone performance evaluations in the context of a laboratory reagent. The device (Cryo✓Check™ PNP Platelet Lysate) is evaluated on its own performance characteristics (specificity, stability, consistency) in conjunction with standard laboratory instruments and established protocols (PNP, APTT). There is no "human-in-the-loop" AI component.

    7. The Type of Ground Truth Used

    The ground truth used for these studies is clinical classification of patient plasma samples (normal vs. known lupus anticoagulant positive) and established laboratory methods (specifically, the Platelet Neutralization Procedure (PNP) and Activated Partial Thromboplastin Time (APTT) measurements). For the stability and analyzer comparison studies, commercially available control plasmas and patient samples classified as "normal" or "lupus positive" served as the reference.

    8. The Sample Size for the Training Set

    Not applicable. This device is a laboratory reagent; there is no mention of an algorithm or AI that would require a "training set." The studies performed are validation studies for the performance characteristics of the physical reagent.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for an algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K963111

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-12-23

    (133 days)

    Product Code
    Regulation Number
    864.7925
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Not Found

    Device Description

    COATEST APC RESISTANCE V or V S test is based on the use of activated protein C in an APTT clotting assay, as was the original test kit.

    AI/ML Overview

    1. Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Implied)Reported Device Performance (COATEST APC™ RESISTANCE V or V S)
    Improved sensitivity for Factor V mutation (FV:Q506) compared to original device."considerably increased sensitivity for the mutation in factor V." "greater than 99 % sensitivity for FV:Q506."
    High discrimination for FV:Q506."high discrimination for FV:Q506." "clear and complete discrimination is obtained for FV:Q506 by both instruments."
    Correlation with the original COATEST® APC™ RESISTANCE method (K945940).Good correlation (R=0.74 in one study) between the new and original methods.
    Applicability on different clot detection instruments.Successfully utilized on Thrombolyzer, MLA/Electra 900C, ACL 300, and ST-4 instruments.
    Appropriate results for patients on: - Oral anticoagulants (OAC) - Normal or low molecular weight (LMW) heparin - Phospholipid antibody syndrome"appropriate results are obtained on analysis of plasmas from patients receiving oral anticoagulants, normal or low molecular weight (LMW) heparin or patients with the phospholipid antibody syndrome." Specific data show correct classification for genotyped patients on heparin and those with phospholipid antibody syndrome.
    Ability to provide normal APT times on heparin up to 1 IU/mL."provides normal APT times to at least 1 IU/mL of normal heparin."
    Similar repeatability and reproducibility to the original device."provides a similar repeatability and reproducibility as Coatest APC Resistance."
    Determination of a narrower APC Ratio range for normal Factor V genotype individuals compared to the original kit."significantly narrower range is obtained with COATEST APC® RESISTANCE V or V S compared to the original Coatest APC Resistance kit."
    Stability of V-DEF Plasma and other reconstituted reagents.Data supports assigned stabilities in the package insert for reconstituted V-DEF plasma. Similar stability for 3mL and 4mL vials. Whole blood and plasma can be stored for at least 7 hours at room temperature.

    2. Sample Size Used for the Test Set and Data Provenance

    The provided text describes several studies that collectively form the basis of the test set.

    • Study 1 (Correlation and Discrimination):
      • Sample Size: 218 acutely ill patients with suspected venous thrombosis or pulmonary emboli and family members.
      • Data Provenance: Retrospective (implied, as patients are "acutely ill" suggesting existing conditions) and likely from clinical settings where these patients were managed. No specific country of origin is mentioned.
    • Study 2 (Correlation and Discrimination):
      • Sample Size: 399 plasmapheresis donors.
      • Data Provenance: Retrospective (implied, as donors would have already provided samples). No specific country of origin is mentioned.
    • Instrument Studies:
      • Thrombolyzer: 97 patients with myocardial infarction and 132 healthy controls.
      • MLA/Electra 900C: 50 thrombotic patients or family members.
      • ACL 300 & ST-4 (OAC patients): 147 patients on OAC therapy (ACL 300) and 129 patients on OAC therapy (ST-4).
      • ACL 300 & ST-4 (Healthy Controls): 61 healthy controls (ACL 300) and 62 healthy controls (ST-4).
      • Heparin Patients: Implied within the OAC/healthy control groups, all genotyped for Factor V.
      • Phospholipid Antibody Syndrome Patients: Samples from these patients were also tested, but no specific number is provided.
      • Data Provenance for Instrument Studies: Retrospective, as these are existing patient samples and controls. No specific country of origin is mentioned.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The text does not explicitly state the number or qualifications of experts used to establish the ground truth for the test sets.

    4. Adjudication Method for the Test Set

    The text does not describe any adjudication method like 2+1 or 3+1. The ground truth appears to be solely based on Factor V gene nucleotide determination (FV:Q506 mutation).

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not conducted. This device is a diagnostic assay, not an AI-assisted interpretation tool for human readers.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    Yes, the studies described are standalone performance evaluations of the COATEST APC™ RESISTANCE V or V S assay. The device itself performs the measurement and provides a result (APC ratio), which is then interpreted against established cut-off values. There is no human-in-the-loop performance described in the context of improving the device's output.

    7. The Type of Ground Truth Used (Expert Consensus, Pathology, Outcomes Data, etc.)

    The primary ground truth used for the test sets was Factor V gene nucleotide determination specifically for the FV:Q506 mutation at position 1691. This is a genetic-level diagnostic certainty.

    8. The Sample Size for the Training Set

    The document does not separately describe a distinct "training set." The studies appear to be validation or test sets. It's possible that the initial development and optimization of the assay (which would involve some form of "training") utilized samples, but those are not clearly delineated as a separate training set with specific numbers in this summary.

    9. How the Ground Truth for the Training Set Was Established

    As no distinct training set is identified, the method for establishing its ground truth is not specified. However, by extension, if any samples were used for initial assay development, their ground truth would likely also be based on Factor V gene nucleotide determination, similar to the test sets.

    Ask a Question