Search Filters

Search Results

Found 22 results

510(k) Data Aggregation

    K Number
    K251872

    Validate with FDA (Live)

    Date Cleared
    2025-11-14

    (149 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Biomoneta Avata Rx is an over-the-counter (OTC) medical recirculating air cleaner intended to remove particles for medical purposes. The device is intended for indoor use only.

    The Biomoneta Avata Rx has been demonstrated to reduce Staphylococcus epidermidis, Klebsiella aerogenes, and MS2 bacteriophage by > 5 log when operated at its highest fan speed for 60 minutes.

    Note: The designation "Rx" in the product name is part of the trade name and does not indicate prescription status.

    Performance was validated in controlled test chambers measuring 9.1 ft × 9.1 ft × 7 ft (bioaerosol) and 12 ft × 12.5 ft × 15 ft (particle reduction).

    Device Description

    Not Found

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K242102

    Validate with FDA (Live)

    Device Name
    CerroZone Mini
    Manufacturer
    Date Cleared
    2024-11-19

    (124 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CerroZone Mini is intended as a room recirculating air cleaner. The system is used for filtering out and inactivating airborne particles (i.e., bacteria and viruses) from the air for medical purposes.

    Device Description

    The CerroZone Mini is a medical recirculating air cleaner that uses multiple inactivation processes, including use of reactive oxidizing species (ozone) and ultraviolet radiation, to inactivate bacteria and viruses in the CerroZone Mini may be used in medical facilities. Once turned on, inlet air is passed through CerroZone Mini's inline flow-through design which inactivates bacteria and viruses in a single pass flow-through. The device generates 110 cubic feet of air per minute (CFM), or 2.00 air changes per hour (ACH) in a standard 5,600 cubic foot room. The process of air being inlet, purified, then outlet, lasts approximately 1.2 seconds. A 4 LOG reduction, or 99.99% reduction, of airborne particles in a standard 579 cubic foot room is achieved in 45 minutes or less.

    AI/ML Overview

    The prompt requests information about a study proving that a medical device meets acceptance criteria. The provided text is an FDA 510(k) clearance letter for the CerroZone Mini, a medical recirculating air cleaner. The document details the device, its indications for use, comparison to a predicate device, and summarizes non-clinical testing.

    However, the provided text does not contain the specifics of a study proving device acceptance criteria in the way one might expect for an AI/algorithm-driven medical device, which is what the prompt implies by asking about sample sizes for test and training sets, expert ground truth, adjudication methods, and MRMC studies. The device in question is an air cleaner, and the "studies" mentioned are laboratory tests assessing its ability to reduce airborne biological agents and ozone emissions, not clinical trials or AI performance evaluations involving human-in-the-loop scenarios.

    Therefore, many of the requested points are not applicable to the data provided for this specific device. I will address only the points for which information is available in the text.

    Here's the analysis based on the provided document:


    1. A table of acceptance criteria and the reported device performance

    Test MethodologyPurposeAcceptance CriteriaReported Device Performance
    MS2 bacteriophage aerosolized into a sealed environmental bioaerosol chamber containing the CerroZone Mini.To evaluate the efficacy of the CerroZone Mini at reducing viability of aerosolized MS2 bacteriophage by a combination of entrainment and destruction.Greater than 4 log reduction (99.99%).Average net log reduction / time, MS2 bacteriophage, 5.76 ± 0.20 / 45 mins.
    Methicillin Resistant Staphylococcus epidermidis (MRSE) aerosolized into a single-pass flow through chamber that modeled the CerroZone Mini.To evaluate the efficacy of the CerroZone Mini at reducing viability of aerosolized bacteria by a combination of entrainment and destruction.Greater than 3 log reduction (99.99%) in single-pass testing.Demonstrated effectiveness against Staphylococcus epidermidis.
    Ozone Emissions assessed per Section 40 of UL 867 & CSA C22.2 No.187.To ensure that ozone emissions are within acceptable levels.Within the maximum acceptable level of ozone, 0.050 ppm, given in 21 CFR 801.415.Emits between 0.000 and 0.002 ppm of Ozone with a measured absolute max of 0.002 ppm.
    Electromagnetic Compatibility and Electrical Safety (EN/IEC 60601-1-2, UL 867 & CSA C22.2 No.187).To demonstrate safety regarding electromagnetic disturbances and electrical safety.Compliance to EN/IEC 60601-1-2 and UL 867 & CSA C22.2 No.187.The subject device is equivalent to a predicate device that tested in compliance.

    2. Sample sizes used for the test set and the data provenance

    The document does not specify exact "sample sizes" in terms of number of runs or specific data points for the biological agent reduction tests, nor does it explicitly state the precise "data provenance" (e.g., country of origin, retrospective/prospective). These are laboratory efficacy and safety tests, not clinical studies with human subjects or large datasets typical for AI model validation. The tests were performed in a controlled laboratory environment.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. "Ground truth" in the context of this device's testing refers to measured physical/biological parameters (e.g., log reduction of bacteria/viruses, ozone concentration), not expert interpretation of medical images or other data typically associated with AI/diagnostic devices. The results are based on quantitative laboratory measurements.

    4. Adjudication method for the test set

    Not applicable. There was no need for adjudication as the "ground truth" was established through direct laboratory measurements, not subjective evaluations or consensus processes.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is an air cleaner, not an AI-assisted diagnostic or decision support tool for human readers. No MRMC study was performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable beyond the device's inherent standalone function as an air cleaner. There is no AI algorithm in the traditional sense that performs a diagnostic or interpretive function. The device's performance is its inherent physical and chemical action on airborne particles.

    7. The type of ground truth used

    The ground truth for the biological agent reduction tests was established through direct quantitative laboratory measurements of the reduction in viable MS2 bacteriophage and Staphylococcus epidermidis concentrations. For ozone emissions, the ground truth was direct measurement of ozone concentration in ppm. For electrical compatibility and safety, the ground truth was compliance with specified international and national standards (EN/IEC 60601-1-2, UL 867, CSA C22.2 No.187), verified through standard engineering tests.

    8. The sample size for the training set

    Not applicable. This device is an air cleaner with a physical mechanism of action, not a machine learning model that requires a "training set."

    9. How the ground truth for the training set was established

    Not applicable as there is no training set for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240696

    Validate with FDA (Live)

    Date Cleared
    2024-06-14

    (92 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Airdog X8 Air Purifier is a mobile air cleaner intended to remove particles from the air for medical purposes. The device is intended for indoor use only. The Airdog X8 has been demonstrated to effectively inactivate H3N2 and reduce Staphylococcus albus by 4 log with L5 speed.

    Device Description

    The Airdog X8 Air Purifier (X8) is a mobile air cleaner. The air from the room enters the X8 and passes a pre-filter, ionization frame, ionization field, collecting plates and carbon filter that captures particular matter and biological agents from the air. The X8 contains multiple PCB modules, device status indicators, power switch and a display panel, it allows user to select between different operation parameters, including auto-mode, sleep mode and wind speed. The Ionization wireframe and the collecting plate can be cleaned routinely and are reusable. X8 is powered from an AC wall outlet. It is intended to be used indoors only. The device is not intended to be connected to other instruments or medical devices.

    AI/ML Overview

    The provided text is a 510(k) Summary for the Airdog X8 Air Purifier. It lacks the details typically found in a study proving a device meets specific acceptance criteria, especially for an AI/ML-driven device with complex performance metrics like those involving human readers or expert consensus. This document pertains to an air purifier, and its "performance data" is focused on physical and biological filtration capabilities, not on an AI's diagnostic or assistive accuracy.

    Therefore, I cannot extract information related to:

    • Sample size used for the test set and data provenance (e.g., country of origin, retrospective/prospective)
    • Number of experts used to establish ground truth and their qualifications
    • Adjudication method for the test set
    • Multi-Reader Multi-Case (MRMC) comparative effectiveness study or effect size
    • Standalone (algorithm only) performance
    • Type of ground truth used (expert consensus, pathology, outcomes data)
    • Sample size for the training set
    • How ground truth for the training set was established

    However, based on the provided text, I can infer the "acceptance criteria" and "reported device performance" related to the air purifier's function.

    Here's a breakdown of what can be extracted:

    1. A table of acceptance criteria and the reported device performance

    While not explicitly called "acceptance criteria" with pass/fail thresholds in the typical AI/ML sense, the document lists specifications and test results that serve as performance benchmarks.

    Acceptance Criteria (Implied)Reported Device Performance
    Biological Agent Reduction (H3N2 Influenza virus)99.99% reduction with L5 speed operation (Airdog X8)
    Biological Agent Reduction (Staphylococcus albus)4 log reduction with L5 speed (Airdog X8)
    Particle Filtration (PM2.5)4-log reduction in PM2.5 particles in 120 minutes in a 30m³ chamber (Airdog X8)
    Ozone EmissionMeets the requirements of UL867 (<50ppb) and USA CRB (Airdog X8)
    Total Bacteria Counts Elimination Ratio4-log elimination ratio of total bacteria counts (Airdog X8)

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified in terms of clinical or image-based samples. The performance metrics relate to controlled laboratory tests (e.g., "30m³ chamber" for particle filtration, specific test conditions for virus/bacteria inactivation).
    • Data Provenance: The tests appear to be laboratory-based ("Bench tests"). No human subject data or image data is mentioned.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. Ground truth for an air purifier's performance (e.g., particle reduction, virus inactivation) is established through standardized laboratory testing protocols, not expert clinical interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. This is not a study involving human readers or subjective interpretations requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This device is an air purifier, not an AI diagnostic or assistance tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Performance data provided is "standalone" in the sense that it's the device's measured performance in controlled laboratory settings. There is no algorithm or AI component mentioned in the description that would operate independently.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • The "ground truth" for the performance claims (e.g., 99.99% reduction of H3N2) is based on laboratory standard testing methodologies for air purification devices, measuring actual physical and biological reductions in controlled environments.

    8. The sample size for the training set

    • Not applicable. This device is an air purifier, not an AI/ML system that requires a "training set."

    9. How the ground truth for the training set was established

    • Not applicable. No training set is involved for this type of device.

    In summary: The provided document is a 510(k) summary for an air purifier, not a report on an AI/ML diagnostic or assistive device. Therefore, most of the requested information regarding AI performance metrics, expert reviews, and study design for AI models is not present and not relevant to this specific device's clearance. The "performance data" focuses on its physical and biological purification capabilities as demonstrated through laboratory bench tests.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223835

    Validate with FDA (Live)

    Device Name
    MA-40, MA-112
    Manufacturer
    Date Cleared
    2023-09-18

    (270 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MA-40 and MA-112 are intended for use as room recirculating air cleaner. The systems are used for filtering out and inactivating airborne particles from the air for medical purposes.

    The MA-40 has been demonstrated to reduce the following airborne microorganisms by >99.99% in a test chamber of 83ft3 (580 ft3)

    BIOAEROSOL TYPESPECIESDEVICE FAN SPEEDTOTAL TRIAL TIME (MINUTES)
    VirusMS2 bacteriophageSpeed 330
    Speed 245
    Speed 190
    VirusPhi-X 174 bacteriophageSpeed 330
    BacterialStaphylococcus EpidermidisSpeed 330
    BacterialEscherichia coliSpeed 330
    BacterialBacillus Subtilis EndosporeSpeed 330
    Speed 245
    Speed 1120
    MoldAspergillus BrasiliensisSpeed 330

    The MA-112 has been demonstrated to reduce the following airborne microorganisms by >99.99% in a test chamber of 83ft3 (580 ft3)

    BIOAEROSOL TYPESPECIESDEVICE FAN SPEEDTOTAL TRIAL TIME (MINUTES)
    VirusMS2 bacteriophageSpeed 420
    Speed 3
    Speed 2
    Speed 1
    VirusPhi-X 174 bacteriophageSpeed 420
    BacterialStaphylococcus EpidermidisSpeed 420
    BacterialEscherichia coliSpeed 420
    BacterialBacillus Subtilis EndosporeSpeed 420
    Speed 3
    Speed 2
    Speed 1
    MoldAspergillus BrasiliensisSpeed 420
    Device Description

    Not Found

    AI/ML Overview

    This document is a 510(k) premarket notification from the FDA, indicating that the device being reviewed is a Medical Recirculating Air Cleaner. Therefore, the device in question is not an AI/ML powered device. The information requested in your prompt (e.g., acceptance criteria for AI algorithms, sample sizes for AI model training/testing, expert adjudication, MRMC studies) is typically associated with the evaluation of AI/ML-driven medical devices.

    Since the document provided is for a physical air cleaner and not an AI/ML device, most of the requested information does not apply. However, I can extract what is provided in the document related to acceptance criteria and performance of this physical medical device.

    Here's an analysis based on the provided document:

    The acceptance criteria for the MA-40 and MA-112 air cleaners are based on their ability to reduce airborne microorganisms. The study proves that the devices meet these criteria by demonstrating a reduction of specific bioaerosol types by >99.99% within certain timeframes in a test chamber.

    1. A table of acceptance criteria and the reported device performance

    The acceptance criterion for both devices is to reduce airborne microorganisms by >99.99%. The tables provided show the time taken to achieve this reduction for different bioaerosol types and device fan speeds. The device performance (achieving >99.99% reduction) is reported for each scenario.

    BIOAEROSOL TYPESPECIESDEVICE FAN SPEEDTOTAL TRIAL TIME (MINUTES) to achieve >99.99% reduction (MA-40)TOTAL TRIAL TIME (MINUTES) to achieve >99.99% reduction (MA-112)Acceptance Criteria: Reduction by >99.99%
    For MA-40
    VirusMS2 bacteriophageSpeed 330Not applicable (MA-40 specific)Met
    Speed 245Not applicable (MA-40 specific)Met
    Speed 190Not applicable (MA-40 specific)Met
    VirusPhi-X 174 bacteriophageSpeed 330Not applicable (MA-40 specific)Met
    BacterialStaphylococcus EpidermidisSpeed 330Not applicable (MA-40 specific)Met
    BacterialEscherichia coliSpeed 330Not applicable (MA-40 specific)Met
    BacterialBacillus Subtilis EndosporeSpeed 330Not applicable (MA-40 specific)Met
    Speed 245Not applicable (MA-40 specific)Met
    Speed 1120Not applicable (MA-40 specific)Met
    MoldAspergillus BrasiliensisSpeed 330Not applicable (MA-40 specific)Met
    For MA-112
    VirusMS2 bacteriophageSpeed 4Not applicable (MA-112 specific)20Met
    Speed 3Not applicable (MA-112 specific)"20" (implied through position, no specific time given for lower speed without breaking the row)Met
    Speed 2Not applicable (MA-112 specific)"20" (implied through position)Met
    Speed 1Not applicable (MA-112 specific)"20" (implied through position)Met
    VirusPhi-X 174 bacteriophageSpeed 4Not applicable (MA-112 specific)20Met
    BacterialStaphylococcus EpidermidisSpeed 4Not applicable (MA-112 specific)20Met
    BacterialEscherichia coliSpeed 4Not applicable (MA-112 specific)20Met
    BacterialBacillus Subtilis EndosporeSpeed 4Not applicable (MA-112 specific)20Met
    Speed 3Not applicable (MA-112 specific)"20" (implied through position)Met
    Speed 2Not applicable (MA-112 specific)"20" (implied through position)Met
    Speed 1Not applicable (MA-112 specific)"20" (implied through position)Met
    MoldAspergillus BrasiliensisSpeed 4Not applicable (MA-112 specific)20Met

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: The test "sample" here refers to the conditions under which the device was tested. The performance was demonstrated "in a test chamber of 83ft³ (580 ft³)". It's not a biological sample size in the sense of patient data. The document does not specify the number of individual tests or replicates run for each bioaerosol type and fan speed.
    • Data Provenance: The document does not specify the country of origin of the data or whether the study was retrospective or prospective. It is a report of performance in a controlled test chamber.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This question is not applicable as this is a physical device being tested for its ability to filter and inactivate microorganisms, not an AI/ML algorithm requiring expert interpretation of medical images or data. The "ground truth" is measured by the reduction of bioaerosols in a controlled environment.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This is not an adjudication process for human interpretation or AI output. The performance is based on quantitative measurements in a laboratory setting.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-powered device, and therefore no MRMC study involving human readers and AI assistance would be conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable, as this is not an AI/ML algorithm. The "standalone" performance is the device's ability to purify air without human intervention beyond turning it on and setting the fan speed.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" is the measured reduction of specific bioaerosol concentrations within the test chamber. This is determined through laboratory methods suitable for quantifying microorganisms, which is an objective measurement rather than a subjective expert assessment.

    8. The sample size for the training set

    Not applicable. This is a physical device, not an AI model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K222416

    Validate with FDA (Live)

    Device Name
    RIA Safeguard
    Manufacturer
    Date Cleared
    2023-05-01

    (264 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RIA SafeGuard is intended as a room recirculating air cleaner. The system is used for filtering out airborne particles PM2.5 from the air for medical purposes, and is intended for over-the-counter use.

    The RIA SafeGuard has wind speed of 1.3 m/s and airflow of 135 CMH (m3/h). Using the HEPA H13 filter, it provides a 4 log (99.99%) reduction in suspended particulate PM2.5 in 120 minutes within a 29.75 m³ room.

    Device Description

    RIA SafeGuard (SG020MS120) is an air purifier that contains the highefficiency HEPA technology and Bi-Polar Ionization (BPI) unit to remove 99.99% of particles as small as 2.5 microns from the air stream. SafeGuard addresses suspended particles with a single wind speed of 1.3 m/s, providing a 4 log reduction in PM2.5 particulates within 120 minutes in a 29.75 m³ space. The airflow is 135 CMH (m3/h). It is intended to be placed in a room such as medical care institutions and hospitals etc. RIA SafeGuard is a product that is designed as one-touch, easy to use, and no contact with patients. RIA SafeGuard has built in a blue LED as the switch-on indicator. All the maintenance should be done by a trained technician. Changing the HEPA is the only recommended maintenance to do by a non-trained technician, recommended renewing every 12 months.

    AI/ML Overview

    The provided text describes the mechanical and electrical performance of an air purification device, not an AI/ML-enabled medical device. Therefore, the information typically required for an AI/ML device's acceptance criteria, such as details about ground truth, expert adjudication, MRMC studies, or training set data, is not present in this document.

    However, I can extract the acceptance criteria and study details relevant to this specific device based on the provided text.

    Here's a breakdown of the acceptance criteria and the study that proves the device meets them, according to the document:

    1. A table of acceptance criteria and the reported device performance:

    Test NamePurposeAcceptance CriteriaReported Performance
    Filtration of ParticlesDemonstration of Device Air Cleaner Efficacy for 4 Log Reduction of PM2.5 Air Particulates in 120 minutes in a 29.75 m³ room.Reduction rate > 99.99% (4 log reduction)Pass
    Ozone Emissions UL867Determine the ozone emissions of the device.The maximum ozone concentration emitted is below the 0.050 ppm standard.Pass
    Electrical Safety Testing IEC 60601-1:2005, IEC 60601-1:2005+AMD1:2012, IEC 60601-1:2005+AMD1:2012+AMD2:2020Determine the general requirements for basic safety and essential performance of the device.Meet the test specification according to the standards.Pass
    Electromagnetic Compatibility (EMC) Testing IEC 60601-1-2:2014Determine the electromagnetic compatibility, emissions and immunity of the device.Meet the test specification according to the standards.Pass

    2. Sample sized used for the test set and the data provenance:

    • Sample Size: The document does not specify a "sample size" in the context of a test set for an AI/ML model. Instead, it refers to a single device (RIA SafeGuard, Model Number: SG020MS120) that underwent non-clinical testing.
    • Data Provenance: The tests were conducted on the subject device, RIA SafeGuard. The exact location or origin of the testing data is not explicitly stated, but the manufacturer is RIA Tech Co., Ltd. located in Taipei City, Taiwan (R.O.C.). The tests were "non-clinical," implying they were conducted in a laboratory or controlled environment, rather than involving patient data (retrospective or prospective).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not applicable to this device's testing. "Ground truth" in the context of an AI/ML model usually refers to labeled data verified by human experts. For a physical device like an air cleaner, the "ground truth" is established through direct physical measurements against predefined engineering and safety standards (e.g., measuring particle reduction with sensors, ozone concentration with detectors). No human experts were involved in establishing the "ground truth" for these physical performance metrics.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not applicable. Adjudication methods are relevant for subjective interpretations of data, typically in AI/ML model validation where multiple experts might disagree on labels. For the physical performance tests conducted, the results are objective measurements that do not require adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not applicable. An MRMC study is relevant for evaluating the impact of an AI/ML system on human performance (e.g., how radiologists improve diagnostic accuracy with AI assistance). The RIA SafeGuard is an air cleaning device, not an AI/ML diagnostic tool, and therefore, an MRMC study was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    This information is not applicable. This question pertains to AI/ML algorithm performance. The "Filtration of Particles" test can be considered an analogue to a standalone performance test for the device in that it measures the device's inherent ability to clean air without human interaction determining its efficacy. However, it's not an "algorithm-only" test.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    The "ground truth" for this device's performance was established through objective physical measurements against established standards and design specifications.

    • For "Filtration of Particles": The ground truth was the measured reduction of PM2.5 particulates using scientific instruments.
    • For "Ozone Emissions": The ground truth was the measured ozone concentration.
    • For "Electrical Safety" and "Electromagnetic Compatibility": The ground truth was compliance with the specified IEC standards determined through testing.

    8. The sample size for the training set:

    This information is not applicable. This device is a physical product, not an AI/ML model that undergoes training with a dataset.

    9. How the ground truth for the training set was established:

    This information is not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K211507

    Validate with FDA (Live)

    Date Cleared
    2022-11-22

    (557 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Airdog is a mobile air cleaner intended to be used to remove particles from the air for medical purposes. The device is intended for indoor use only. The Airdog has been demonstrated to effectively inactivate H3N2 and reduce Staphylococcus albus by 4 log with L4 speed.

    Device Description

    The Airdog X5 Recirculating Air Cleaner is a floor-standing air cleaner with an air quality sensor. The air from the room enters the X5 and passes a pre-filter, ionization frame, ionization field, collecting plates and carbon layer that captures particular matter and virus from the air. The X5 contains multiple PCB modules, air quality sensor, device status indicators, power switch and a display panel it allows user to select between different operation parameter, including auto-mode, sleep mode and wind speed. The Ionization Wireframe and the Collecting Plate can be cleaned routinely and are reusable. X5 is powered from an AC wall outlet. It is intended to be used indoors only.

    AI/ML Overview

    This document is a 510(k) Pre-market Notification from the FDA regarding the Airdog X5 Recirculating Air Cleaner (model KJ300F-X5). It's a regulatory approval document and thus primarily focuses on demonstrating substantial equivalence to a predicate device rather than providing a detailed scientific study report with all the requested specifics.

    Based on the provided text, here's the information regarding acceptance criteria and the study that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    Performance MetricAcceptance Criteria / Predicate Performance (K200321 Novaerus NV1050)Reported Device Performance (Airdog X5)
    Reduction of Biological AgentsBacillus Globigii endospores and MS2 phage reduced by 3 log in 10 minutes and 4 log in 15 minutes.H3N2 Influenza virus inactivating by 99.99% (4 log) with L4 speed. Staphylococcus albus reduced by 99.99% (4 log) in 1 hour.
    Filtration of Particles4 log reduction in 0.5 to 2.0 μm sized particles in 10 minutes in a 580ft³ (16.4m³) sealed room.Produces a 4 log reduction in PM2.5 particles in 120 minutes in a 30 m³ chamber.
    Ozone EmittedBelow 10 ppb (Implies meeting regulatory requirements, which are typically <50 ppb for air purifiers).Meet the requirements of UL867 (<50ppb) for ozone and USA CRB. (ETL test results also show that even if the carbon net is removed, the ozone is lower than regulatory requirements).

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not specify the exact sample sizes (e.g., number of replicates for each test run) for the biological agent inactivation, particle reduction, or ozone emission tests.

    The data provenance is not explicitly stated as "retrospective" or "prospective." However, these were undoubtedly prospective bench tests conducted to evaluate the device's performance against specific standards and claims. The country of origin for the tests is not specified, but the manufacturer is BeiAng Air Tech Ltd. located in China.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the studies described are bench tests evaluating the physical and biological performance of an air cleaner, not human-centric studies requiring expert interpretation of data like medical image analysis. The "ground truth" for these tests would be established by scientific measurement standards and protocols in a controlled laboratory environment.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable for bench tests. These tests are quantitative measurements, not subjective evaluations requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is an air cleaner and does not involve human readers or AI assistance in a diagnostic context.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device is an air cleaner, not an algorithm. The performance described is its standalone mechanical and biological effectiveness.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the biological agent reduction and particle filtration, the "ground truth" is based on controlled laboratory measurements of the concentration of specific microorganisms or particles before and after air cleaner operation, relative to standard controls. For ozone emission, the "ground truth" is defined by regulatory standards (e.g., UL867) for maximum allowable ozone concentration.

    8. The sample size for the training set

    Not applicable. This is a physical device, not a machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. (See #8)

    Ask a Question

    Ask a specific question about this device

    K Number
    K220990

    Validate with FDA (Live)

    Device Name
    Qorda QD1
    Manufacturer
    Date Cleared
    2022-09-14

    (163 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Qorda QD is intended as a room recirculating air cleaner. The system is used for filtering out and inactivating airborne particles from the air for medical purposes.

    The Qorda QD1 has been demonstrated to remove the following organisms under the following exposure conditions:

    OrganismFan SpeedAverage Maximum logreductionExposure Time
    MS2 bacteriophageTurbo MODE5.6 log reduction20 minutes
    MS2 bacteriophageSleep MODE4.9 log reduction45 minutes
    Bacillus subtilisendosporesTurbo MODE4.4 log reduction20 minutes
    Bacillus subtilisendosporesSleep MODE4.3 log reduction60 minutes
    Device Description

    Oorda OD1 is a freestanding medical recirculation air cleaner that facilitates movement with wheels. The device includes two pre-filters, two deodorizing filters, two HEPA filters - 3 filters in the front panel and 3 filters in the rear panel), and a manual for users.

    The device can adjust the air volume in four stages through manual operation (Level 1, Level3, Turbo) and Sleep mode. When operating in sleep mode, the equipment LED and PlasmaWave are turned off and operated with low noise.

    The device contains the following additional functions.

    (1)Child lock: Button lock function that prevents children or pets from changing their current motion mode even if they accidentally operate device.

    (2)Filter Replacement Guide: The remaining filter life is displayed on the front display of the device and tells you when to replace the filter.

    (3)Adjustment of illuminance: You can adjust the illuminance in four stages (100%, 50%, 20%, OFF).

    (4)You can turn on or off the PlasmaWave.

    (5)The timer allows the equipment to turn off automatically after a certain period of time.

    Qorda QD1 inhales air in both directions on the front and rear of the device and purifies it through the four cleaning steps below:

    [Pre-Filter]

    The air is drawn in through the cover front, passes through the Pre-Filter then moves to two filters stages(CD Carbon Filter, True HEPA Filter). The Pre-Filter protects CD Carbon Filter, True HEPA Filter inside the Pre-Filter.

    [CD Carbon Filter]

    Reduces any ozone generated as a byproduct of the plasma field. It also prolongs the True HEPA Filter lifespan.

    [True HEPA Filter]

    True HEPA Filter captures 99.99%* of airborne ultrafine particles as small as 0.003 microns. *Based on independent laboratory test conducted on particles as small as 0.003 microns in size.

    [PlasmaWave]

    PlasmaWave Technology has been tested by an independent third-party to remove particles from the air for medical purposes.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study information for the Qorda QD1 device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test NameAcceptance CriteriaReported Device Performance
    Ozone EmissionsOzone emitted to be < 0.050 ppmPass with the device operating in normal operating conditions under both TURBO and SLEEP Modes. The QD1 units averaged under 1.0 ppb of ozone emission throughout the 24-hour testing, with a maximum generation level less than 2.07 ppb. (0.00207 ppm)
    Filtration of ParticlesThe device produces a 4 log reduction in the concentration of µm sized the two organism types (the MS2 bacteriophage and Bacillus subtilis endospores) and poly-styrene latex (PSL) microspheresThe QD1 produces a 3 log reduction in 0.5 to 4.0 µm sized particles in 10 minutes when operating at Turbo speed in a chamber (internal dimensions are 9.1 ft x 9.1 ft x 7 ft, with a displacement volume of 579 ft³, or 16.4 m³).
    Combined OperationTo produce a 4 log reduction in the specified microorganismsThe QD1 unit, set to 'Turbo', was effective at reduction of both organisms (the MS2 bacteriophage and Bacillus subtilis endospores) by the required net log reduction of 4.0 or greater (equivalent to 99.99% or greater reduction) within 20 minutes when operating in a chamber (internal dimensions are 9.1 ft x 9.1 ft x 7 ft, with a displacement volume of 579 ft³, or 16.4 m³).
    Air Change Rate TestThe criteria of air change rate in each mode is higher than the following:- Sleep mode is 6,000 ft³/h- Level 1 mode is 11,400 ft³/h- Level 2 mode is 13,800 ft³/h- Level 3 mode is 16,200 ft³/h- Turbo mode is 27,900 ft³/hAir change rate of the QD1 showed that all results were higher than the standard air change range required for each stage.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for biological reduction and particle filtration: The text mentions the tests were conducted in "a chamber (internal dimensions are 9.1 ft x 9.1 ft x 7 ft, with a displacement volume of 579 ft³, or 16.4 m³)." This suggests a single test environment or chamber was used for multiple tests (ozone, particle filtration, and biological reduction). The exact number of runs or repetitions within this chamber for each test is not specified, but the phrasing implies controlled laboratory conditions rather than a large-scale field study.
    • Data Provenance: The studies are non-clinical, controlled laboratory tests. There is no information regarding the country of origin of the data explicitly, but Winix Inc. is based in the Republic of Korea, and the correspondent is in the USA. The tests were likely performed in a controlled laboratory setting by a third-party testing facility. The nature of these tests is prospective as they were designed and executed to evaluate the device's performance against predefined criteria.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. The ground truth for these performance tests is established by objective measurements and scientific methodologies in a laboratory setting (e.g., measuring ozone concentration, particle counts, and biological log reduction) rather than expert interpretation of images or clinical outcomes.

    4. Adjudication Method for the Test Set

    Not applicable. As these are objective performance tests measuring physical and biological parameters, there is no need for an adjudication method typically used for subjective assessments.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. This document describes non-clinical performance testing of an air cleaning device, not a diagnostic or clinical imaging device that would involve human readers or MRMC studies.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, in a sense. The tests described are for the standalone performance of the Qorda QD1 device in an automated manner (filtering and inactivating at different fan speeds) without human intervention during its operation or performance assessment.

    7. The Type of Ground Truth Used

    The ground truth used in these studies is based on:

    • Direct Measurement of Physical and Chemical Properties:
      • Ozone concentration (ppb).
      • Particle counts and sizes (µm).
      • Air volume and air change rates (ft³/h or m³/h).
    • Direct Measurement of Biological Inactivation/Reduction:
      • Log reduction of specified microorganisms (MS2 bacteriophage and Bacillus subtilis endospores).

    These are objective, quantifiable measurements derived from controlled laboratory experiments.

    8. The Sample Size for the Training Set

    Not applicable. This device is an air cleaner, not an AI/machine learning algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As there is no AI/machine learning component, there is no training set or associated ground truth establishment for a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K220298

    Validate with FDA (Live)

    Device Name
    CerroZone Mobile
    Manufacturer
    Date Cleared
    2022-07-01

    (149 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CerroZone Mobile is intended as a room recirculating air cleaner. The system is used for filtering out and inactivating airborne particles (i.e., bacteria and viruses) from the air for medical purposes.

    Device Description

    The CerroZone Mobile is a medical recirculating air cleaner that uses multiple inactivation processes consisting of reactive oxidizing species (ozone) and ultraviolet radiation to inactivate bacteria and viruses in the air. The CerroZone Mobile may be used in medical facilities. Once turned on, inlet air is passed through CerroZone Mobile's inline flow-through design which inactivates bacteria and viruses in a single pass flow-through. The device generates 220 cubic feet of air per minute (CFM), or 2.36 air changes per hour (ACH) in a standard 5,600 cu. Ft room. This process of air being inlet, purified, then outlet, lasts approximately 1.2 seconds. A 4 LOG reduction of airborne particles in a standard 579 cu. Ft room is achieved in 30 minutes or less. A 5.67 LOG, or 99.9998%, reduction is achieved in 45 minutes or less.

    AI/ML Overview

    The CerroZone Mobile device is a medical recirculating air cleaner designed to filter out and inactivate airborne bacteria and viruses. The following information summarizes its acceptance criteria and the studies conducted.

    1. Table of Acceptance Criteria and Reported Device Performance:

    Test MethodologyPurposeAcceptance CriteriaReported Device Performance
    MS2 bacteriophage aerosolization in a sealed environmental bioaerosol chamberTo evaluate the efficacy of the CerroZone Mobile at reducing viability of aerosolized MS2 bacteriophage by a combination of entrainment and destructionGreater than 4 log reduction (99.99%)Average net log reduction for MS2 bacteriophage: 5.67 ± 0.19 / 60 minutes
    Methicillin Resistant Staphylococcus epidermidis (MRSE) aerosolization in a single-pass flow-through chamber connected to the CerroZone MobileTo evaluate the efficacy of the CerroZone Mobile at reducing viability of aerosolized bacteria by a combination of entrainment and destructionGreater than 3 log reduction (99.9%) in single-pass testingDemonstrated effectiveness against Staphylococcus epidermidis
    Ozone EmissionsTo assess ozone emissionsEmissions within the maximum acceptable level of ozone given in 21 CFR 801.415 (0.050 ppm)Emits between 0.000 and 0.010 ppm of Ozone with a measured absolute max of 0.036 ppm. All emissions fall within the acceptable level.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the sample sizes for the biological aerosolization tests (MS2 bacteriophage and MRSE). The studies appear to be laboratory-based non-clinical tests rather than human subject or field trials, so terms like "country of origin" and "retrospective/prospective" might not be strictly applicable in the same way they would be for clinical studies. The context implies these were controlled experiments conducted to assess device performance under specific conditions.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This information is not provided in the document. The "ground truth" for these non-clinical tests would have been established by the direct measurement of reduction in viable microorganisms using standard microbiological techniques, rather than expert interpretation.

    4. Adjudication Method for the Test Set:

    Not applicable. The tests involved direct measurement of microbial reduction, not subjective interpretation requiring adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done:

    No, an MRMC comparative effectiveness study was not done. The CerroZone Mobile is a medical device for air cleaning, not an interpretative diagnostic tool, so such a study would not be relevant.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    These were standalone performance tests of the device itself (algorithm not applicable), evaluating its ability to reduce airborne pathogens directly.

    7. The Type of Ground Truth Used:

    The ground truth used for the efficacy studies was based on quantitative laboratory measurements of microbial viability (e.g., plaque assays for bacteriophages, colony counts for bacteria) before and after exposure to the device. For ozone emissions, the ground truth was direct quantitative measurement of ozone concentration.

    8. The Sample Size for the Training Set:

    Not applicable. This device is a physical air cleaner, not an AI/ML algorithm. Therefore, there is no "training set" in the context of machine learning.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K200321

    Validate with FDA (Live)

    Device Name
    Novaerus NV1050
    Manufacturer
    Date Cleared
    2020-12-28

    (322 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Novaerus NV 1050 is intended as a room recirculating air cleaner. The system is used for filtering out and inactivating airborne particles from the air for medical purposes.

    Device Description

    The Novaerus NV1050 (NV1050) is a free-standing cabinet of a size that can be maneuvered into position by a single person. The NV1050 is powered from an AC wall outlet. The NV1050 circulates the room air through its cabinet. The air is drawn in through the front of the cabinet, passes through a pre-filter then a Dielectric Barrier Discharge Plasma generator ("plasma generator") stage, and a further two filters (HEPA, Carbon) The cleaned air is exhausted out of the top panel of the cabinet. The device has simple controls: On/Off and fan speed setting from 1 to 5. There is a button to initiate a filter blockage test to check and inform the user if the filters are getting close to requiring changing. The only routine maintenance is a calendar-based filter change schedule indicated in the User Manual; the indicator light on the front panel acts as a reminder that the filters will soon need attention. The airflow path through the NV1050 is: - A general pre- filter to remove particles from the input air flow. . - A bank of three (3) plasma generators, each Plasma Generator consists of ● two (2) plasma Coils. Micro-Organisms, including virus and bacteria, are inactivated by the plasma generator. This occurs through damage by plasma constituents (ions, electrons, reactive oxidizing species, ultraviolet radiation, high electric fields) - A HEPA (High-efficiency Particulate Air) filter to trap the resulting virus/bacteria particulates. - . An activated carbon filter to trap any ozone in the airstream before it is output to the environment.

    AI/ML Overview

    The provided text describes the Novaerus NV1050 medical recirculating air cleaner and its substantial equivalence to a predicate device. It includes information on non-clinical testing to demonstrate performance against acceptance criteria.

    Here's the breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test name/Methodology/Standard namePurposeAcceptance CriteriaResult
    IEC60601-1:2005/A1;2012Device electrical safetyPass the requirements of the consensus standardPass
    IEC60601-1-2:2014Device Electromagnetic CompatibilityPass the requirements of the consensus standardPass
    Ozone emissionsConfirm ozone emissions are below the maximum permitted levels <0.050 ppmOzone emitted to be <0.050 ppmPass in normal operating conditions and single fault conditions including operating with blocked and past end of life filters
    Inactivation of Micro-organismsTo demonstrate that the plasma technology alone can produce a 4 log reduction in viable micro-organismsThe plasma generator alone produces a 4 log reduction in a specified micro-organismA single plasma generator of the type embodied in the NV1050 produced a 4 log reduction in MS2 Bacteriophage in 5 hours when operating in a sealed 580ft3 (16.4m3) room
    Filtration of particlesTo demonstrate that the filter banks alone can produce a 4 log reduction in particlesThe device produces a 4 log reduction in the concentration of µm sized polystyrene microspheresThe device produced a 4 log reduction in the concentration of 0.5 to 2.0 µm sized polystyrene microspheres in a sealed 580ft3 (16.4m3) room in 10 minutes
    Combined OperationTo demonstrate the performance of the NV1050 at maximum speed to inactivate and filter out specified micro-organismsTo produce a 4 log reduction in the specified micro-organismsNV1050 running at maximum speed in a 580ft3 (16.4m3) sealed room: • Bacillus Globigii Endospores: A 4 log reduction produced in 15 minutes. Prolonged operation over 24 hours to confirm that the reduction in the micro-organisms was maintained and no viable micro-organisms were recycled back into the ambient air. • MS2 Bacteriophage: A 4 log reduction produced in 15 minutes.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: The sample size for the "Inactivation of Micro-organisms", "Filtration of particles", and "Combined Operation" tests involved a single device (Novaerus NV1050) operating in a sealed 580ft3 (16.4m3) room. For the electrical safety and EMC tests, the sample size is not explicitly stated but implies testing of the device itself.
    • Data Provenance: The document does not specify the country of origin of the data or whether the studies were retrospective or prospective. It only states that "The following performance data has been provided to demonstrate that the subject device meets the acceptance criteria of the standards listed below." The tests appear to be laboratory-based performance evaluations rather than clinical studies on patient populations.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The provided text describes performance testing of an air cleaning device; it does not involve establishing ground truth from expert interpretation of medical images or data. Therefore, this question is not applicable in this context. The ground truth for these tests would be the measured reduction in microorganisms or particles, or compliance with electrical and EMC standards, based on established scientific methods and instrumentation, not expert consensus.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This question is not applicable as the described testing methodology is for device performance (reduction of microorganisms, filtration, electrical safety, EMC) rather than the interpretation of data where adjudication among readers would be necessary.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    An MRMC study is relevant for AI-assisted diagnostic devices involving human readers. The Novaerus NV1050 is an air cleaning device, and its performance evaluation does not involve human readers interpreting data. Therefore, an MRMC comparative effectiveness study was not done, and this question is not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is framed for AI algorithms. For this device, the "standalone" performance refers to the device's ability to reduce microorganisms and filter particles on its own, without human intervention in its air purification function. The tests for "Inactivation of Micro-organisms," "Filtration of particles," and "Combined Operation" demonstrate the device's standalone performance in a controlled environment.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the performance tests described involves:

    • Quantitative measurement of reduction: For microorganism inactivation, the ground truth is the measured log reduction of MS2 Bacteriophage and Bacillus Globigii Endospores. For particle filtration, it's the measured log reduction of polystyrene microspheres.
    • Compliance with standards: For electrical safety and electromagnetic compatibility, the ground truth is whether the device meets the specified requirements of IEC 60601-1 and IEC 60601-1-2.
    • Quantitative measurement of emissions: For ozone emissions, the ground truth is the measured concentration of ozone.

    These are objective, empirical measurements based on scientific methodologies rather than expert consensus, pathology, or outcomes data typically associated with diagnostic medical devices.

    8. The sample size for the training set

    The provided text only discusses non-clinical performance testing of the final device and does not mention any "training set" for AI/machine learning. This device is an air cleaner, not an AI-driven diagnostic or therapeutic system that would typically require training data. Therefore, this question is not applicable.

    9. How the ground truth for the training set was established

    As there is no mention of a training set for an AI/machine learning model, this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K130702

    Validate with FDA (Live)

    Device Name
    AIRSONETT AIR-4
    Manufacturer
    Date Cleared
    2013-07-23

    (130 days)

    Product Code
    Regulation Number
    880.5045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Airsonett AIR-4 is a Mobile Air Cleaner intended to be used to remove particles from the air for medical purposes. The device is intended for home use only.

    Device Description

    Airsonett is based on the Temperature controlled Laminar Airflow (TLA) technology. The air from the room enters the Airsonett and passes a filter that captures allergens and other particles. The filtered air is cooled to slightly below the ambient room temperature and is supplied with a low velocity from the air supply nozzle. Since the filtered air is slightly cooler, and therefore heavier than the surrounding air, the filtered air will descend slowly from the air supply nozzle by means of gravity in a laminar manner (non-turbulent). This descending colder air counteracts the body convection, displaces the allergen load in the breathing zone and thus dramatically reduces the level of inhalant allergens for the patient all through the night.

    Air is drawn in through the air intake at the floor level and through the HEPA filter. A silent Blower (fan) brings airflow through the filter. The air is directed through the Cooler/Heater and divided into a cool respectively warm air flow. The cool air flow is directed through the Air guidance arm (neck) and out through the Airshower (Air Supply Nozzle). The Airshower can be altered in height, by adding/removing and combining the neck parts, to adapt to different types of environments. The warm air flow is directed to the Warm air outlet. On its way to the outlet the air flow passes the electronics and transports away the extra heat produced by the electronics.

    Airsonett is based on a microprocessor controlled supervisory system. This system controls the device behaviour by measuring temperatures, controlling thermoelectric modules and fan unit, monitoring user interaction as well as management of internal timers to keep track of the total ontime for the system and time since last filter change. The control functions (Front Panel Board) and power distribution function (Power Electronics Board) are allocated on two separate circuit boards.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Airsonett device, based on the provided text:

    Acceptance Criteria and Device Performance

    Study EndpointAcceptance CriteriaReported Device Performance
    Air quality in treated air envelope (clean zone)Filter Filtration efficiency ≥99.5% of particles with size Ø≥0.5µmConforms with filtration efficiency ≥99.5%.
    Air quality in treated air envelope (clean zone)Clean zone Filtration efficiency ≥99.5% of particles with size Ø≥0.5µm, which is equivalent to -Class 1000 according to FED STD 209E and -Class 6 according to ISO 14644-1 in environments of <200 000particles/ft³.Conforms with filtration efficiency ≥99.5%. ⇒ Class 1000 according to FED STD 209E and Class 6 according to ISO 14644-1 in environments of ≤200 000particles/ft³. AIR-4 is equivalent or better than previous version AIR-3, with regard to Air quality in treated air envelope (clean zone).
    Air quality in treated air envelope (clean zone)Stability of the clean zone shall be preserved. Filter efficiency shall be preserved.The stability of the clean zone is preserved and the filter does not deteriorate on efficiency over a normal working life.
    Temperature difference between supply air and ambient airTemperature difference between supply air and ambient air: ≥0.75°C (1.35 degrees F).Conforms with temperature difference between supply air and ambient air: ≥0.75°C (1.35 degrees F).

    Study Details

    1. Sample size used for the test set and the data provenance:

      • Sample Size: The document does not explicitly state a sample size for the test set. The performance tests appear to be conducted on the device itself, rather than using patient data. For example, "Efficiency test results of filter" and "Particle cleanliness of clean zone of Airsonett AIR-4."
      • Data Provenance: Not applicable as the tests are on device performance, not patient data.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. The ground truth for the device's technical performance is established by standardized measurement methods (e.g., laser counters for particles, temperature sensors for temperature difference) and engineering specifications, rather than expert consensus on medical images or diagnoses.
    3. Adjudication method for the test set:

      • Not applicable. The tests are objective measurements of the device's physical and mechanical performance characteristics against predefined standards, not subjective interpretations requiring adjudication.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No MRMC study was done. This device is a "Mobile Air Cleaner" and does not involve AI or human readers for diagnostic interpretation. Its function is to physically clean air.
    5. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

      • A standalone performance assessment of the device (without human intervention in its function) was done, as evidenced by the "Performance Tests" section. The device's filtration efficiency and temperature control were measured directly.
    6. The type of ground truth used:

      • Objective Measurement/Engineering Standards: The ground truth for the Airsonett device's performance is based on objective measurements against established engineering and environmental control standards (e.g., particle counts, temperature differential) and filtration efficiency as defined by industry norms (e.g., FED STD 209E, ISO 14644-1).
    7. The sample size for the training set:

      • Not applicable. This device is an air cleaner, not an AI/machine learning algorithm, so there is no concept of a "training set" in the context of these performance tests.
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set for this type of device.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 3