510(k) Data Aggregation

    K Number
    K222124

    Validate with FDA (Live)

    Date Cleared
    2022-11-04

    (109 days)

    Product Code
    Regulation Number
    880.5570
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Sterile Hypodermic Syringe with/without needle: The Sterile Hypodermic Syringe with/without needle is intended for use in the aspiration and injection of fluids for medical purposes.
    Sterile Hypodermic Needle: The Sterile Hypodermic Needle is intended to be used with a syringe for fluids aspiration and injection for medical purposes.

    Device Description

    The Sterile Hypodermic Syringe with/without needle is intended for use in the aspiration and injection of fluids for medical purposes. The Sterile Hypodermic Needle is intended to be used with a syringe for fluids aspiration and injection for medical purposes. It is intended for the patient population, including adults, transitional adolescents, adolescents, and children. The device is intended for use in a professional healthcare facility. The device is a disposable syringe made of the following components: Needle cap, Needle tube, Needle hub, Barrel, Plunger, Plunger stopper.

    AI/ML Overview

    The provided submission describes a medical device, a Sterile Hypodermic Syringe with/without Needle and a Sterile Hypodermic Needle, and does not involve AI/ML. Therefore, the requested information regarding acceptance criteria and studies that prove the device meets these criteria in the context of AI/ML, human readers, ground truth, and sample sizes for training/test sets is not applicable to this document.

    The document focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance testing, biocompatibility testing, sterilization validation, and package/shelf-life testing. No clinical data was submitted.

    However, based on the non-clinical performance testing sections, I can extract the acceptance criteria and the studies performed to meet them as they relate to the physical device properties.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Standard/TestReported Device Performance
    PerformanceISO 7886-1 (Sterile hypodermic syringes for single use - Part 1: Syringes for manual use)Complied with standard requirements
    ISO 9626 (Stainless steel needle tubing for the manufacture of medical devices - Requirements and test methods)Complied with standard requirements
    ISO 7864 (Sterile hypodermic needles for single use -- Requirements and test methods)Complied with standard requirements
    ISO 80369-7 (Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications)Complied with standard requirements
    ISO 80369-20 (Small-bore connectors for liquids and gases in healthcare applications part 20: standard test methods)Complied with standard requirements
    ISO 6009 (Hypodermic needles for single use Colour coding for identification)Complied with standard requirements
    BiocompatibilityISO 10993-5: 2009 (In Vitro Cytotoxicity)Conforms to standard
    ISO 10993-10: 2010 (Sensitization)Conforms to standard
    ISO 10993-10: 2010 (Intracutaneous Reactivity)Conforms to standard
    ISO 10993-11: 2017 (Acute Systemic Toxicity)Conforms to standard
    ISO 10993-4:2017 (Coagulation)Conforms to standard
    ISO 10993-4: 2017 (Complement activity)Conforms to standard
    ISO 10993-4: 2017 & ASTM F756-17 (Hemolytic Properties)Conforms to standard
    Sterilization ValidationISO 11135-1 (Sterilization of health care products - ethylene oxide - part 1)Complied with standard requirements
    ISO 11737-1 (Sterilization of medical devices-Microbiological methods-Part 1)Complied with standard requirements
    ISO 11737-2 (Sterilization of medical devices -- Microbiological methods -- Part 2)Complied with standard requirements
    ISO 10993-7 (Biological evaluation of medical devices - Part 7: Test of Ethylene Oxide Residuals)Complied with standard requirements
    AAMI / ANSI ST72 (Bacterial endotoxins - Test methods, routine monitoring, and alternatives to batch testing)Complied with standard requirements
    Package and Shelf LifeAAMI/ANSI/ISO 11137-1 (Sterilization of health care products - Radiation - Part 1)Complied with standard requirements
    AAMI/ANSI/ISO 11737-2 (Sterilization of medical devices - Microbiological methods - Part 2)Complied with standard requirements
    AAMI/ANSI/ISO 11607-1 (Packaging for terminally sterilized medical devices - Part 1)Complied with standard requirements
    ASTM F1929-15 (Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration)Complied with standard requirements
    ASTM F1980-16 (Accelerated Aging of Sterile Barrier Systems for Medical Devices)Complied with standard requirements
    ASTM D3078-02 (2021) (Determination of Leaks in Flexible Packaging by Bubble Emission)Complied with standard requirements
    DIN58953-6: 2016 (Microbial barrier testing of packaging materials)Complied with standard requirements
    ASTM F88/F88M-15 (Seal Strength of Flexible Barrier Materials)Complied with standard requirements
    Package Integrity TestsAccelerated Aging TestConducted
    Simulated shipping distribution testingConducted
    Visual inspectionConducted
    Performance Inspection (Chemical and Physical)Conducted
    Sterile TestConducted
    Vacuum Leak TestConducted
    Dye penetration testConducted
    Agar Contact-Attack TestConducted
    Tensile Seal Strength TestConducted

    The remaining requested information is not applicable to this document as it pertains to AI/ML device studies, which this submission is not.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not applicable as this is a traditional medical device (syringe/needle) and not an AI/ML device. Performance testing for traditional devices typically involves testing physical samples defined by the relevant standards, not a "test set" of data in the AI/ML sense. No specific country of origin or retrospective/prospective nature of data for these tests is mentioned beyond the manufacturing location (China).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable as this is not an AI/ML device study. Ground truth in this context would refer to the validated methods and accepted performance limits defined by the referenced international standards, rather than expert consensus on data interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable as this is not an AI/ML device study.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable as this is not an AI/ML device study. No human reader studies are mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable as this is not an AI/ML device study.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • For the non-clinical performance, biocompatibility, sterilization, and packaging tests, the "ground truth" is defined by the objective pass/fail criteria and methodologies outlined in the referenced international and national consensus standards (e.g., ISO, ASTM, AAMI/ANSI). These standards represent established scientific and engineering principles for evaluating medical device safety and performance.

    8. The sample size for the training set

    • Not applicable as this is not an AI/ML device study.

    9. How the ground truth for the training set was established

    • Not applicable as this is not an AI/ML device study.