Found 23 results

510(k) Data Aggregation

    K Number
    K254233

    Validate with FDA (Live)

    Date Cleared
    2026-03-12

    (73 days)

    Product Code
    Regulation Number
    878.3550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CMF MEDPOR® Customized Implant is indicated for the augmentation, and/or restoration of bony and/or soft tissue deformities in post-traumatic, post-surgical, or congenital craniofacial defects, including, but not limited to, the correction and prevention of persistent temporal hollowing (PTH).

    Device Description

    The CMF MEDPOR® Customized Implant is a patient-specific implant designed at the request of a surgeon. It is comprised of two identical sterile Implants, an optional Host Bone Model, and a Design Proposal. The implants are individually sterilized using ethylene oxide. The customized implants are molded from porous high-density polyethylene (HDPE) to the specific reconstructed boundaries indicated by the surgeon via submission of CT scans and a customized implant request. This submission expands available design options without altering material composition or intended use.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Spine Guidance 5.4 Software Indications for Use:

    The Q Guidance System, when used with the Spine Guidance 5 Software, is intended as a planning and intraoperative guidance system to enable open or percutaneous computer assisted surgery in adult and pediatric (adolescent) patients.

    The system is indicated for orthopedic and neurological spine procedures in which the use of computer assisted planning and surgery may be appropriate. The system can be used for intraoperative stereotaxic guidance where a reference to a rigid anatomical structure such as the skull, pelvis or spine can be identified.

    The system assists in the positioning of instruments for surgical procedures on the spine and pelvis, including:

    • Screw and Needle Placement in the spine or pelvis
    • Bone resection in the spine
    • Interbody device placement in the lumbar spine (adults only)

    Elite Q Attachments and Cutting Accessories:

    The Elite Q Attachments and Cutting Accessories are intended to be used with the Stryker Consolidated Operating Room Equipment (CORE™) 2 Console and the Pi Drive 2 Motor or the Pi Drive 2 Plus Motor.

    The Elite Q Attachments, when used with a compatible motor and a stereotactic instrument tracker, are also indicated as an accessory to the Stryker Spine Guidance Software.

    Specific applications include but are not limited to minimally invasive spine (MIS) Spine applications, such as foraminotomy, facetectomy; orthopedic and neurological spine applications, such as corpectomy, pedicle subtraction osteotomy; and laminotomy / laminectomy.

    Maestro Air Motor:

    The Stryker Consolidated Operating Room Equipment (CORE™) Maestro Air Pneumatic System is a pneumatically operated surgical instrument system. The pneumatic motor provides power to operate removable rotating surgical cutting tools and their accessories intended for use in neurosurgery, including craniotomy and spinal surgery; as well as ear, nose and throat (ENT), orthopedic, and general surgical applications including maxillofacial, craniofacial and sternotomy surgeries.

    The Maestro Air Motor, when used with a compatible Elite Q Attachment and a stereotactic instrument tracker, is also indicated as an accessory to the Stryker Spine Guidance Software.

    Device Description

    The Spine Guidance 5.4 System is an image guided stereotaxic, planning, and intraoperative guidance system intended to enable open or percutaneous computer-assisted surgery. It assists the surgeon in precisely positioning manual and powered instruments and locating patient anatomy during spinal surgery.

    The system is comprised of the Spine Guidance 5.4 Software, the Q Guidance System (computer platform), Mako Spine System, navigated accessories / instruments (e.g., powered drills, pointers), and various system components (e.g., calibration devices, navigation adapters, patient / instrument trackers, etc.). The system provides intraoperative guidance to the surgeon using passive and active wireless optical tracking technologies.

    The computer platform consists of a computer, camera, big touchscreen monitor, and a small touchscreen monitor. The Spine Guidance 5.4 Software functionality is described in terms of its capabilities that feature planning, registration, and navigation of medical devices.

    The Spine Guidance 5.4 Software includes all the existing features from the Spine Guidance 5.3 Software described in K252871. Updates to the software include the integration of the Q Drill Tracker as a new system component, ability to navigate the Maestro Air Motor, integration of additional burs, and now allows the NavLock Adapter to be used with two additional trackers.

    The Maestro Air Motor is intended to be used with a compatible attachment and cutting accessory for cutting, drilling, reaming, decorticating, shaping, and smoothing of bone and bone cement in a variety of surgical procedures. The motor is usable in placement or cutting of screws, metals, wires, pins, and other fixation devices. The motor can also be navigated when performing computer assisted surgery using Spine Guidance 5.4 Software.

    The Elite Q Attachments serve as the interface between a compatible motor and a distally attached cutting accessory. The Elite Q Attachments provide a location for mounting a stereotactic instrument tracker and support navigation of a high-speed drill as well as the system's instrument tip proximity detection feature.

    The Elite Cutting Accessories are used for cutting, drilling, reaming, decorticating, shaping, and smoothing of bone, bone cement in a variety of surgical procedures. The cutting accessories can also be used in the placement or cutting of screws, metal, wires, pins, and other fixation devices. The cutting accessories support navigation of a high-speed drill as well as the system's instrument tip proximity detection feature.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252871

    Validate with FDA (Live)

    Date Cleared
    2026-02-06

    (149 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Spine Guidance 5.3 Software Indications for Use:
    The Q Guidance System, when used with the Spine Guidance 5 Software, is intended as a planning and intraoperative guidance system to enable open or percutaneous computer assisted surgery in adult and pediatric (adolescent) patients.

    The system is indicated for orthopedic and neurological spine procedures in which the use of computer assisted planning and surgery may be appropriate. The system can be used for intraoperative stereotaxic guidance where a reference to a rigid anatomical structure such as the skull, pelvis or spine can be identified.

    The system assists in the positioning of instruments for surgical procedures on the spine and pelvis, including:

    • Screw and Needle Placement in the spine or pelvis
    • Bone resection in the spine
    • Interbody device placement in the lumbar spine (adults only)

    Q Interbody Instruments Indications for Use:
    VB Spine Q Interbody Instruments are intended to be used as accessories to the Stryker Spine Guidance System to facilitate placement of VB Spine implants. They can be navigated instruments or non-navigated manual instruments. When navigated, VB Spine Q Interbody Instruments are specifically designed for use with the Spine Guidance Software. They are intended to be used with associated trackers and adaptors to facilitate preparation and placement of VB Spine interbody implants in accordance with the indications and contraindications of the associated VB Spine Implant System and/or Stryker Spine Guidance System.

    Elite Q Attachments and Cutting Accessories:
    The Elite Q Attachments and Cutting Accessories are intended to be used with the Stryker Consolidated Operating Room Equipment (CORE™) 2 Console and the Pi Drive 2 Motor or the Pi Drive 2 Plus Motor.

    The Elite Q Attachments, when used with a compatible motor and a stereotactic instrument tracker, are also indicated as an accessory to the Stryker Spine Guidance Software.

    Specific applications include but are not limited to minimally invasive spine (MIS) Spine applications, such as foraminotomy, facetectomy; orthopedic and neurological spine applications, such as corpectomy, pedicle subtraction osteotomy; and laminotomy / laminectomy.

    Device Description

    5.1 Spine Guidance 5.3 Software

    The Spine Guidance 5.3 Software includes all the existing features from the Spine Guidance 5.2 Software described in K241517 as well as new features and functionality for the new software indication for interbody device (cage) placement.

    New features and functionality in the Spine Guidance 5.3 Software include the following:

    • New user settings where the user can select the cage family and size to be used as default in Navigation.

    • New user setting to visualize instruments and implants as 3D models within the Navigation views.

    • Integration and visualization of the following VB Spine Cage implant families:
    ○ Cascadia AN
    ○ Tritanium PL
    ○ Cascadia Lateral

    • Supports and visualizes navigation enabled instruments for interbody placement workflow such as inserters, dilators, disc prep instruments, and interbody trials, as well as system components such as calibration devices and adaptors.
    ○ Once the instruments have been calibrated, the software can identify the instrument tip and axis and display it on the screen during Navigation.
    ○ When the user calibrates the interbody inserter, the cage inserter family is automatically identified by the software. The family is determined by the specific and unique length of the inserter and calibration tip.

    5.2 Q Interbody Instruments

    The Q Interbody Instruments in scope of this traditional 510(k) include Q Dilators, Q Disc Prep Instruments such as Q Disc Cutters, Q Box Chisels, etc. as well as new system components including the Q Long Adaptor and Q Long Adaptor Calibration Tool. The Q Interbody Instruments are intended to be used to facilitate preparation and placement of VB Spine interbody implants.

    5.3 Elite Q Attachments

    The Elite Q Attachments serve as the interface between the Pi Drive 2 Motors and a distally attached cutting accessory. The Elite Q Attachments provide a location for mounting a stereotactic instrument tracker and support the high-speed drill instrument tip proximity detection feature of the Spine Guidance Software.

    5.4 Elite Cutting Accessories

    The Elite Cutting Accessories are used for cutting, drilling, reaming, decorticating, shaping, and smoothing of bone, bone cement, and teeth in a variety of surgical procedures. The cutting accessories can also be used in the placement or cutting of screws, metal, wires, pins, and other fixation devices. The cutting accessories support the high-speed drill instrument tip proximity detection feature of the Spine Guidance Software.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243491

    Validate with FDA (Live)

    Date Cleared
    2024-12-11

    (29 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SternalPlate System is indicated for use in stabilization and fixation of fractures of the anterior chest wall including sternal fixation following sternotomy, sternal fracture(s), and sternal reconstructive surgical procedures to promote bony fusion.

    Device Description

    This Special 510(k) is submitted to evaluate the modifications to the Predicate Device plates resulting in the Subject Device plates. There have been no changes to the previously cleared plates and screws cleared in K183172, this submission is only for the addition of the four new Subject Device plates. The four Subject Device plates include T-Plates and Transverse Plates. Both Subject Device variants, the T-Plates and Transverse Plates, are geometrically derived from the following Predicate Device plates: the Ladder Plate Narrow (Reff/ 4740006) and the Straight 24-hole Plate (Ref# 4740012). The Subject Device plates therefore have the same features, the same tolerances, and are made from the same material as the Predicate Device plates. Furthermore, the Subject Device plates are manufactured with the same manufacturing process as the Predicate Device plates.

    AI/ML Overview

    The provided FDA 510(k) summary (K243491) for the Stryker SternalPlate Expansion device focuses on the mechanical performance of the device and its biocompatibility. The document does not contain information related to software, AI, or human-in-the-loop performance. Therefore, many of the requested criteria cannot be extracted from this document.

    Here's the information that can be extracted or deduced from the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document states that the "Subject Device plates met all acceptance criteria as compared to the Additional Predicate Devices." However, the specific quantitative acceptance criteria (e.g., minimum stiffness, maximum deflection) and the detailed reported performance values are not explicitly stated in the provided 510(k) summary. The summary only mentions "appropriate strength and stiffness."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document refers to "Performance Bench Testing" but does not specify the sample size for the mechanical tests. The tests compare the Subject Device to "Additional Predicate Devices," implying a comparative mechanical study rather than a clinical data-driven study. Data provenance (country of origin, retrospective/prospective) is not applicable as it's a bench test, not clinical data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This question is not applicable as the document describes mechanical bench testing of an orthopedic implant, not a diagnostic device requiring expert interpretation of images or data to establish a ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This question is not applicable as the document describes mechanical bench testing. Adjudication methods are typically relevant for clinical studies or studies involving human readers/interpreters.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    There is no mention of a multi-reader multi-case (MRMC) comparative effectiveness study. This document is for a physical orthopedic implant, not an AI-powered diagnostic tool. Therefore, the effect size of human readers with/without AI assistance is not relevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable as the device is a physical orthopedic implant, not a standalone algorithm or software.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the performance bench testing, the "ground truth" would be the engineering specifications and established mechanical testing standards against which the device's strength and stiffness are evaluated. The document states "The Subject Device plates met all acceptance criteria as compared to the Additional Predicate Devices," implying a comparison against established performance benchmarks of legally marketed devices.

    8. The sample size for the training set

    This question is not applicable as the device is a physical orthopedic implant. There is no concept of a "training set" in the context of mechanical bench testing for this type of device.

    9. How the ground truth for the training set was established

    This question is not applicable for the reasons stated above.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241517

    Validate with FDA (Live)

    Date Cleared
    2024-08-27

    (90 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Q Guidance System, when used with the Spine Guidance 5.2 Software, is intended as a planning and intraoperative guidance system to enable open or percutaneous computer assisted surgery in adult and pediatric (adolescent) patients.

    The system is indicated for any surgical procedure on the spine in which the use of computer assisted planning and surgery may be appropriate. The system can be used for intraoperative guidance where a reference to a rigid anatomical structure such as the skull, pelvis or spine can be identified.

    The system assists in the positioning of instruments for procedures on the pelvis and spine, including:
    · Screw and Needle Placement in the spine or pelvis
    · Bone resection in the spine

    The Mako Spine System is intended to be used as an accessory to the Stryker Spine Guidance System. It is intended to be used to facilitate preparation and placement of screws of Stryker Spine implants in the non-cervical spine in adult and pediatric (adolescent) patients.

    The Mako Spine System is intended to be used as part of the Stryker Spine Guidance System, which is indicated for any surgical procedure on the spine in which the use of computer assisted planning and surgery may be appropriate. The system can be used for intraoperative guidance where a reference to a rigid anatomical structure such as the spine or pelvis can be identified.

    The Stryker System 8 Dual Trigger Rotary Battery Powered Heavy Duty System is intended for use in the drilling, reaming, and decorticating of bone and other bone related tissue in a variety of surgical procedures. They are also usable in the placement of screws, wires, pins, and other fixation devices.

    The Stryker System 8 Dual Trigger Rotary Battery Powered Heavy Duty System, when used in conjunction with Stryker Spine Guidance Software, is intended to be used to facilitate preparation and placement of screws of Stryker Spine implant systems in adult and pediatric (adolescent) patients.

    Device Description

    The Spine Guidance System is a computer-assisted stereotaxic, image-guided, planning, and intraoperative guidance system intended to enable open or percutaneous computer-assisted surgery on the spine and pelvis. It assists the surgeon in precisely positioning manual and powered instruments and locating patient anatomy during spinal surgery. The system is comprised of the Spine Guidance 5.2 Software, Q Guidance System (computer platform), Mako Spine System, navigated accessories/ instruments (e.g., patient/ instrument trackers, pointers), and various system components (e.g., trackers, calibration instruments, etc.).

    The system provides intraoperative guidance to the surgeon using passive and active wireless optical tracking technologies as well as haptic trajectory guidance to facilitate pedicle preparation and screw placement using Mako Spine System.

    The Spine Guidance 5.2 Software displays the intraoperative location of navigated surgical instruments relative to imported patient medical images via wireless optical tracking technology. The software provides the functions to perform the indicated navigated spine surgical procedures. The software guides the user through the necessary preoperative and intraoperative steps required to set-up and perform the navigated spine surgical procedures.

    The Mako Spine System is an accessory to the subject Spine Guidance 5.2 (SG5.2) Software and extends the functionality of the SG5.2 Software to provide trajectory guidance to align the End Effector tube with a pre-planned screw trajectory to facilitate preparation and placement of screws in the non-cervical spine. The Mako Spine System includes a Mako 3.5 Robotic arm, new dedicated instrumentations (i.e. Spine Pedicle End Effector, Spine Pedicle Registration Tool, Pedicle Instruments, etc.), and previously cleared compatible instruments (i.e. Vizadisc, Rio System Quick Connect Base Array, End Effector Tracker Array, Calibration End-Effector, etc.). Mako 3.5 Robotic Arm is connected to the existing Q Guidance System (K233542) via Mako ethernet cable.

    The System 8 Dual Trigger Rotary Handpiece is used in the drilling, reaming, and decorticating of bone and other bone related tissue in a variety of surgical procedures. It is also used in the placement of screws, wires, pins, and other fixation devices. The handpiece, when used with a compatible instrument tracker, can be used with the Spine Guidance 5.2 Software to facilitate preparation and placement of screws using Stryker Spine implant systems.

    AI/ML Overview

    The provided text does not contain information about acceptance criteria or a study that proves the device meets specific performance metrics. Instead, the document is an FDA 510(k) clearance letter for the Stryker Q Guidance System, Mako Spine System, and System 8 Rotary Handpiece.

    A 510(k) submission generally focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than detailed performance studies with specific statistical acceptance criteria as would be found in a clinical trial or a robust standalone AI performance study.

    The document mentions "non-clinical performance testing" which includes:

    • Software testing as required by IEC 623304 and FDA Guidance on General Principles of Software Validation.
    • System accuracy verification per ASTM F2554.
    • Full system cadaver validation.
    • Biocompatibility verification according to ISO 10993-1:2018.
    • Sterilization validation of reusable devices per ISO 17665-1.
    • Shelf-life validated per ISO 11607-1:2019, ISO 11607-2:2019, ASTM F1980-21.
    • Electrical Safety and Electromagnetic Compatibility verification to IEC 60601-1 and IEC 60601-1-2.

    However, it does not provide details on:

    1. A table of acceptance criteria and reported device performance. While "System accuracy verification per ASTM F2554" is mentioned, the specific metrics, thresholds, and results are not provided.
    2. Sample size, data provenance, number of experts, adjudication methods for any test set, or details of any MRMC study. The document states "No clinical testing was required to support this submission," which means there would be no human reader study or corresponding ground truth establishment on a clinical test set as described in your prompt.
    3. Standalone (algorithm-only) performance results, as this device is a guidance system, not a diagnostic AI algorithm.
    4. Type of ground truth used in the context of an AI performance study, as such a study was not required or detailed.
    5. Sample size for the training set or how ground truth was established for it. This information pertains to AI model development, which is not the focus of this 510(k) submission document.

    In summary, based on the provided text, it is not possible to answer your questions regarding acceptance criteria, performance data, test set details, ground truth establishment, or AI-specific study methodologies, because the document is a 510(k) clearance that explicitly states "No clinical testing was required to support this submission" and focuses on demonstrating substantial equivalence through non-clinical performance and other regulatory compliance tests.

    The document does describe the Indications for Use for the Q Guidance System and Mako Spine System, which outlines the intended purpose and patient population. It also provides a Summary of Technological Characteristics comparing the subject devices to predicate devices. However, this is for demonstration of substantial equivalence, not a detailed performance study with quantifiable acceptance criteria and results as typically seen for AI/ML devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241171

    Validate with FDA (Live)

    Date Cleared
    2024-07-25

    (90 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K240651

    Validate with FDA (Live)

    Device Name
    MRI Universal
    Date Cleared
    2024-07-12

    (127 days)

    Product Code
    Regulation Number
    872.4760
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Universal CMF System Intended use The Universal CMF System is intended for stabilization and rigid fixation of the craniomaxillofacial (CMF) skeleton. Indications for use Craniomaxillofacial Implants The Universal CMF System is Craniomaxillofacial (CMF) plate and screw system intended for osteotomy, stabilization, and rigid fixation of CMF fractures and reconstruction. Mandible Implants The Universal CMF System (mandible modules) is a mandibular plate and screw system intended for stabilization and rigid fixation of mandibular fractures and mandibular reconstruction. MP Lefort I Plates Intended Use The Stryker Leibinger Universal CMF and Universal 2.0 Mini Plating Systems are Craniomaxillofacial (CMF) plate and screw systems intended for osteotomy, stabilization, and rigid fixation of CMF fractures and reconstruction. Indications for Use The MP LeFort I Plates as part of the predicate subgroup Universal 2.0 Mini Plating System are implants indicated for osteotomy, stabilization, and rigid fixation of LeFort I fractures of the maxillofacial skeleton. Stryker Upper-Face AXS Screws And Mid-Face AXS Screws Indications for Use The Stryker Universal CMF System is a Cranio-maxillofacial (CMF) plate and screw system intended for osteotomy, stabilization, and rigid fixation of CMF fractures and reconstruction. Stryker MP, Mandible, HMMF And MMF AXS Screws -Universal CMF System: Intended Use The Universal CMF System is intended for stabilization and rigid fixation of the craniomaxillofacial (CMF) skeleton. Indications for Use Craniomaxillofacial Implants The Universal CMF System is Craniomaxillofacial (CMF) plate and screw system intended for osteotomy, stabilization, and rigid fixation of CMF fractures and reconstruction. Mandible Implants The Universal CMF System (mandible modules) is a mandibular plate and screw system intended for stabilization and rigid fixation of mandibular fractures and mandibular reconstruction. -Stryker Universal SMARTLock Hybrid MMF System: Intended Use The Stryker Universal SMARTLock Hybrid MMF System is intended to be used for temporary stabilization of mandibular and maxillary fractures in order to maintain proper occlusion during fracture healing. Indications for Use The Stryker Universal SMARTLock Hybrid MMF System is indicated for the treatment of mandibular and maxillary fractures in adults and adolescents (age 12 and higher) in whom permanent teeth have erupted. -Stryker MMF Screw Intended use The Stryker MMF Screw is intended for use as a bone screw in the temporary maxillomandibular fixation to provide indirect stabilization of fractures of the maxilla, mandible or both, where there is sufficient occlusion. Indications for use The Stryker MMF Screw is intended for use as a bone screw in the temporary maxillomandibular fixation to provide indirect stabilization of fractures of the maxilla, mandible or both, where there is sufficient occlusion. Stryker Universal Orbital Floor System Intended Use The Stryker Universal Floor System is intended to be used in the reconstruction of the floor and/or medial wall of the orbit. Indications for Use The Stryker Universal Orbital Floor System is indicated for the reconstructive treatment of orbital floor and/or medial wall trauma or bone excision in patients 15 years of age and older. Stryker Universal Smartlock Hybrid MMF System Intended use The Stryker Universal SMARTLock Hybrid MMF System is intended to be used for temporary stabilization of mandibular and maxillary fractures in order to maintain proper occlusion during fracture healing. Indications for use The Stryker Universal SMARTLock Hybrid MMF System is indicated for the treatment of mandibular and maxillary fractures in adults and adolescents (age 12 and higher) in whom permanent teeth have erupted. Stryker MMF Screw Intended use The Stryker MMF Screw is intended for use as a bone screw in the temporary maxillomandibular fixation to provide indirect stabilization of fractures of the maxilla, mandible or both, where there is sufficient occlusion. Indications for use The Stryker MMF Screw is intended for use as a bone screw in the temporary maxillomandibular fixation to provide indirect stabilization of fractures of the maxilla, mandible or both, where there is sufficient occlusion.

    Device Description

    This Bundled. Traditional 510(k) is for a single change the MR status that affects multiple devices and can be assessed during one review. There are no changes to the predicate devices themselves, just the addition to allow MR Conditional use of the implants in scope after MRI compatibility testing was completed. Associated labeling for each Predicate Device is also updated to reflect the MR conditional use of the implants.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Q Guidance System, when used with the Spine Guidance Software, is intended as a planning and intraoperative guidance system to enable open or percutaneous computer assisted surgery in adult and pediatric (adolescent) patients.

    The system is indicated for any surgical procedure on the spine in which the use of computer assisted planning and surgery may be appropriate. The system can be used for intraoperative guidance where a reference to a rigid anatomical structure such as the skull, pelvis or spine can be identified.

    The system assists in the positioning of instruments for procedures on the pelvis and spine, including:
    • Screw and Needle placement in the spine or pelvis.

    Device Description

    The Spine Guidance 5.0 system is an image guided stereotaxic, planning, and intraoperative guidance system intended to enable open or percutaneous computer-assisted surgery. It assists the surgeon in precisely positioning manual and powered instruments and locating patient anatomy during spinal surgery.

    The system is comprised of the Spine Guidance 5.0 Software, the Q Guidance System (computer platform), navigated accessories/ instruments (e.g., powered drills, pointers), and various system components (e.g., calibration devices, navigation adaptors, patient/ instrument trackers, etc.). The system provides intraoperative guidance to the surgeon using passive and active wireless optical tracking technologies. The computer platform consists of a computer, camera, big touchscreen monitor, and a small touchscreen monitor. The Spine Guidance 5.0 software functionality is described in terms of its capabilities that feature planning, registration, and navigation of medical devices.

    AI/ML Overview

    The provided document is an FDA 510(k) summary for the Stryker Spine Guidance Software (version 5.0) and associated instruments. It details the device's characteristics, intended use, and comparison to predicate devices, as well as the non-clinical testing performed to establish substantial equivalence.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    AccuracySystem demonstrated performance in 3D positional accuracy with a mean error ≤ 2.0 mm and in trajectory angle accuracy with a mean error < 2.0 degrees. This performance was determined using anatomically representative phantoms and utilizing a subset of system components and features that represent the worst-case combinations of all potential system components.
    SoftwareSoftware verification and validation testing was conducted as required by IEC 62304 and FDA Guidance on General Principles of Software Validation, January 11, 2002. All requirements were met, and no new issues of safety or effectiveness were raised.
    BiocompatibilityThe biocompatibility of all patient contact materials was verified according to ISO 10993-1:2018 and the FDA guidance Use of International Standard ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process, September 2023. No new issues of safety or effectiveness were raised.
    Electrical Safety and Electromagnetic CompatibilityVerified conformance to IEC 60601-1:2005. IEC 60601-1:2005/AMD1:2012. IEC 60601-1:2005/AMD2:2020. Verified conformance to IEC 60601-1-2:2014, IEC 60601-1-2:2014/AMD1:2020, CISPR 11 Group 1, Class A requirements as well as additional testing to verify compatibility with RFID devices operating in the 125-134 kHz and 13.56 MHz frequency band.
    SterilizationThe reusable subject devices underwent a steam sterilization to demonstrate that they can be expected to be sterile and have a sterility assurance level (SAL) of 10-6 or greater after processing. The Tracking Instrument Battery underwent gamma sterilization validation per ISO 11137-2: 2013/(R) 2019 to demonstrate that they can be expected to be sterile and have a sterility assurance level (SAL) of 10-6.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    The document does not specify the exact sample size for the test set used in the accuracy testing. It mentions "anatomically representative phantoms" and "a subset of system components and features that represent the worst-case combinations of all potential system components." The data provenance (country of origin, retrospective/prospective) is not mentioned.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The document does not mention the use of experts to establish a ground truth for the test set. The accuracy testing was performed using "anatomically representative phantoms," implying a technical or engineering validation rather than clinical or expert-based ground truth.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    No adjudication method for a test set is described, as the testing focused on technical accuracy using phantoms, not on human interpretation or clinical outcomes adjudicated by experts.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The document explicitly states: "No clinical testing was required to support this submission." Therefore, no MRMC comparative effectiveness study was performed or reported. The device is a guidance system, not an AI diagnostic tool requiring human reader improvement comparison.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    The document describes non-clinical testing for system accuracy and software validation. The reported accuracy of "mean error ≤ 2.0 mm for positional displacement and < 2.0 degrees for trajectory angle displacement" refers to the standalone performance of the system as measured against known phantom parameters. This suggests that the algorithm's performance in guiding instruments was assessed directly against a predefined ground truth in a controlled environment.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the accuracy testing, the ground truth was established by the precise measurements of "anatomically representative phantoms." This implies a technical or engineered ground truth rather than expert consensus, pathology, or outcomes data.

    8. The sample size for the training set

    The document does not provide information about a training set. This is a 510(k) summary focusing on a device that is substantially equivalent to a predicate, not necessarily a de novo submission for a novel AI algorithm requiring a specific training set size to establish performance. The software verification and validation would have involved testing against requirements, but not necessarily a "training set" in the machine learning sense.

    9. How the ground truth for the training set was established

    Since no training set is mentioned, the method for establishing its ground truth is not provided.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233542

    Validate with FDA (Live)

    Date Cleared
    2024-03-14

    (132 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ortho Guidance Precision Knee Software:
    The Stryker guidance systems, with the Ortho Guidance Precision Knee Software, are intended as a planning and intraoperative quidance system to enable open computer-assisted surgerv. The systems can be used for intraoperative guidance where a reference to a rigid anatomical structure can be identified. The systems are indicated for conditions of the knee joint in which the use of computer-assisted surgery may be appropriate.

    Ortho Guidance Express Knee Software:
    The Stryker quidance systems, with the Ortho Guidance Express Knee Software, are intended as a planning and intraoperative guidance system to enable open computer-assisted surgery. The systems can be used for intraoperative guidance where a reference to a rigid anatomical structure can be identified. The systems are indicated for conditions of the knee joint in which the use of computer-assisted surgery may be appropriate.

    Ortho Guidance Versatile Hip Software:
    The Stryker guidance systems, with the Ortho Guidance Versatile Hip Software, are intended as a planning and intraoperative guidance system to enable open computer-assisted surgery.

    The systems can be used for intraoperative guidance where a reference to a rigid anatomical structure such as but not limited to the pelvis, or femur, can be identified.

    The systems are indicated for conditions of the hip joint in which the use of computer-assisted surgery may be appropriate.

    The system is indicated for the following surgical procedures:

    • Total Hip Arthroplasty (THA)

    • Precisely positioning instruments, implants, and bony tissue during orthopaedic hip surgery

    • Revisions

    Q Guidance System:
    The Q Guidance System is intended as an aid for precisely locating anatomical structures in open or percutaneous computer assisted surgery. When used with the Ortho Guidance Precision Knee, Express Knee, or Versatile Hip Software, the Q Guidance System is indicated for any medical condition in which the use of computer assisted planning and surgery may be appropriate and where reference to a rigid anatomical structure such as the femur, tibia, or long bone can be identified.

    Device Description

    The system is intended as a planning and intraoperative guidance system to enable open computer-assisted surgery. It allows for the localization of surgical instruments, and visualization of their position relative to patient specific anatomical landmark information, assisting the surgeon in performing the intervention at a high level of precision. The system uses active optical tracking technology to display to the surgeon the intraoperative location of navigated surgical instruments relative to a computed anatomical model. The computed model is based on an intraoperative anatomy survey of the pelvis and/or leg.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study information for the Stryker Q Guidance System and its associated software, based on the provided document:


    Acceptance Criteria and Device Performance

    Acceptance CriteriaReported Device Performance
    System Accuracy (point)Mean accuracy of 2 mm point displacement within the registration zone.
    System Accuracy (angular)Mean accuracy of 2° angular axis displacement within the registration zone.
    Trueness for LED fiducial (mean Euclidean error)$\le 150 \mu m$
    Trueness for LED fiducial (95% percentile of Euclidean error)$< 0.35 mm$
    Trueness for reflective fiducial (mean Euclidean error)$\le 150 \mu m$
    Trueness for reflective fiducial (95% percentile of Euclidean error)$\le 0.35 mm$
    Trueness for single flashing LED fiducial$LME_{mean} \le 70 \mu m + 70 \mu m/m * L, L \le 1.5 m$
    Intended Use/User NeedsAll requirements were met, and no new issues of safety or effectiveness were raised through validation with intended users in cadaver labs or simulated use tests.
    SafetyEffectiveness of all risk controls determined in the device risk analysis was verified. No new questions of safety or effectiveness were raised.
    General Requirements and PerformanceAll components met their design specifications. No new questions of safety or effectiveness were raised.
    SoftwareSoftware verification and validation testing was conducted as required by IEC 62304 and FDA guidance on general principles of software validation, January 11, 2002. All requirements were met, and no new questions of safety or effectiveness were raised.
    BiocompatibilityNot applicable, as the subject devices are not intended to be patient contacting.
    Electrical SafetyConformance to IEC 60601-1 Ed. 3.2 (2005 + AMD1:2012 + AMD2:2020) was verified.
    Electromagnetic CompatibilityConformance to IEC 60601-1-2 Ed. 4.1 (2014 + AMD1:2020), CISPR 11 Group 1 Class A was verified.
    ShippingFunctionality of the devices after simulated shipping conditions was verified. No new questions of safety or effectiveness were raised.
    SterilizationNot applicable, as the subject devices are not intended to be sterilized.

    The study that proves the device meets the acceptance criteria is a non-clinical design verification and validation testing campaign.


    Study Details

    1. Sample size used for the test set and the data provenance:

      • The document does not specify a numerical sample size for the test set regarding the accuracy measurements. It mentions that testing was performed internally by the manufacturer.
      • Data Provenance: The data appears to be from internal testing conducted by Stryker Leibinger GmbH & Co. KG, located in Germany. The tests involved cadaver labs or simulated use, suggesting controlled laboratory environments rather than real-world patient data. The provenance is therefore prospective in a simulated environment.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • The document does not explicitly state the number or qualifications of experts used to establish ground truth for the numerical accuracy tests (e.g., fiducial trueness, system accuracy). These types of measurements are typically established using highly precise metrological equipment as the ground truth.
      • For "Intended Use/User Needs" testing, "intended users" were involved in cadaver labs or simulated use tests. However, the exact number and qualifications (e.g., specific surgical experience) of these "intended users" (e.g., surgeons) are not specified.
    3. Adjudication method for the test set:

      • The document does not describe a formal adjudication method for the test set results. The accuracy metrics are quantitative measurements against an established standard. The user needs validation was presumably based on observation and feedback from the intended users.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No MRMC comparative effectiveness study was done or reported. The device is a surgical guidance system, not an AI diagnostic tool that assists human readers in interpreting medical images. The testing described focuses on the system's accuracy in tracking and guiding surgical instruments.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Yes, standalone performance was assessed. The accuracy measurements for fiducial trueness and system point/angular accuracy represent the direct, standalone performance of the tracking and guidance algorithms. The "Intended Use/User Needs" validation also assessed the integration and utility with a human user.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • For the accuracy metrics (e.g., trueness for fiducials, system accuracy), the ground truth is implicitly defined by metrological standards and highly precise measurement systems, which assess the physical displacement and angulation of tracked objects.
      • For "Intended Use/User Needs," the ground truth involves user feedback and achievement of functional requirements observed in cadaver labs or simulated environments.
    7. The sample size for the training set:

      • The document does not specify a numerical sample size for the training set. This is a navigation system primarily based on optical tracking and software for workflow and display, rather than a machine learning model that requires a discrete "training set" of patient data in the conventional sense. The "training" of such a system would involve extensive engineering, calibration, and iterative development based on design parameters and physical principles.
    8. How the ground truth for the training set was established:

      • As this is not a machine learning-based device that would typically have a "training set" with explicit ground truth labels, the concept of ground truth for a training set in the AI sense does not directly apply here. Instead, during development and "training" of the underlying algorithms and hardware, ground truth is established through:
        • Physical calibration standards: For optical tracking, this involves precise optical benches and measurement devices to calibrate camera parameters, fiducial patterns, and spatial relationships.
        • Engineering specifications and simulations: Ground truth for software logic and mechanical tolerances is derived from engineering design requirements and validated through simulations.
        • Iterative testing and refinement: Early prototypes and software versions undergo extensive testing against known inputs and expected outputs to refine performance.
    Ask a Question

    Ask a specific question about this device

    K Number
    K231599

    Validate with FDA (Live)

    Date Cleared
    2023-08-24

    (84 days)

    Product Code
    Regulation Number
    872.4880
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    -Stryker Universal SMARTLock Hybrid MMF System: The Stryker Universal SMARTLock Hybrid MMF System is indicated for the treatment of mandibular and maxillary fractures in adults and adolescents (age 12 and higher) in whom permanent teeth have erupted.
    -Universal CMF System: Craniomaxillofacial Implants The Universal CMF System is Craniomaxillofacial (CMF) plate and screw system intended for osteotomy, stabilization, and rigid fixation of CMF fractures and reconstruction. Mandible Implants The Universal CMF System (mandible modules) is a mandibular plate and screw system intended for stabilization and rigid fixation of mandibular fractures and mandibular reconstruction.
    -Stryker MMF screw: The Stryker MMF Screw is intended for use as a bone screw in the temporary maxillomandibular fixation to provide indirect stabilization of fractures of the maxilla, mandible or both, where there is sufficient occlusion.

    Device Description

    The Subject Device screws are screw versions modified with the Stryker AXS Screw technology, where the abbreviation "AXS" stands for axial stability. This submission is adding the AXS Screw technology to the Subject Device. The Subject Device screws have modified geometry and features which will be implemented as AXS Screws in each of the existing Predicate/Reference Device systems. This includes screws with a length range of 4-20 mm and a diameter range from 2.0-2.7 mm. The materials (titanium and stainless steel) are the same as for the corresponding Predicate/Reference Devices. There are no other changes to the Predicate/Reference Device systems, only the implementation of the AXS Screw technology to each existing product line. The Subject Device screws will have the same clinical application, treat the same craniomaxillofacial anatomical locations, and are for the same patient population as the corresponding Predicate/Reference Devices.

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to Stryker MP, Mandible, HMMF and MMF AXS Screws, which are intraosseous fixation screws. This submission is for a medical device (screws), not an AI/software as a medical device (SaMD). Therefore, the questions related to AI device performance, sample sizes for test/training sets, expert ground truth, adjudication methods, MRMC studies, or standalone algorithm performance are not applicable to this document.

    The clearance is based on demonstrating substantial equivalence to predicate devices, primarily through engineering performance bench testing.

    Here's the relevant information that can be extracted from the document:

    1. A table of acceptance criteria and the reported device performance

    The document states that "The Subject Device met all pre-defined acceptance criteria, and the results of the V&V tests support the substantial equivalence of the Subject Device to the Predicate/Reference Devices." However, the specific numerical acceptance criteria for each test are not detailed in this summary document. The document lists the types of performance bench tests conducted:

    Test NameReported Device Performance (as stated in document summary)
    Pull-out Test per ASTM F543Met all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Full Insertion and Removal Test per ASTM F543Met all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Shaft Shear Test per ASTM F543Met all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Head Shear TestMet all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Locking Cantilever Bending TestMet all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Locking Torque to Failure TestMet all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.
    Self-Retention TestMet all pre-defined acceptance criteria, supporting substantial equivalence to Predicate/Reference Devices.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the summary document. The document refers to "Verification and Validation (V&V) testing" and "test reports" being included within the full submission, but the summary itself does not detail specific sample sizes for these bench tests or the provenance of any data beyond the general statement that testing was performed.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not Applicable. This is a medical device (screws) and does not involve AI or software requiring expert review for ground truth establishment. The "acceptance criteria" are engineering performance metrics.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not Applicable. This is a medical device (screws) and does not involve subjective human interpretation or adjudication for its performance evaluation in the way an AI diagnostic tool would. Performance is based on objective engineering tests.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not Applicable. This is a medical device (screws) and does not involve AI or human "readers."

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not Applicable. This is a medical device (screws) and does not involve an algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    For mechanical performance tests, the "ground truth" or reference standard would be the physical properties and behavior of the devices as measured by standardized testing methods (e.g., ASTM F543) and compared against pre-defined engineering specifications and the performance of the predicate device.

    8. The sample size for the training set

    Not Applicable. This is a medical device (screws) and does not involve a training set as would be used for AI/machine learning.

    9. How the ground truth for the training set was established

    Not Applicable. This is a medical device (screws) and does not involve a training set.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 3