Search Filters

Search Results

Found 615 results

510(k) Data Aggregation

    K Number
    K252416

    Validate with FDA (Live)

    Date Cleared
    2025-10-29

    (89 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AETOS Shoulder System (when used with the AETOS Humeral Meta Stems) is to be used only in patients with an intact or reconstructable rotator cuff, where it is intended to provide increased mobility and stability and to relieve pain.

    The AETOS humeral stems (AETOS Humeral Meta Stems) and head may be used by themselves, as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with the glenoid, as a total replacement.

    When used with the AETOS Humeral Meta Stems, The AETOS Shoulder System is indicated for use as a replacement of shoulder joints disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The AETOS Shoulder System (when used with AETOS Stemless Humeral Prosthesis) is to be used only in patients with an intact or reconstructable rotator cuff.

    When used with AETOS Stemless Humeral Prosthesis, the AETOS Shoulder System is indicated for anatomic total shoulder replacement of shoulder joints disabled by:

    • Non-inflammatory degenerative joint disease
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The coated humeral components are intended for uncemented use. The glenoid component is intended for cemented use only.

    In Reverse:

    The AETOS Shoulder System, when used with AETOS Humeral Meta Stems, is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with massive and non-repairable rotator cuff-tear with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of devices if sufficient bone stock remains

    The humeral liner component is indicated for use in the AETOS Shoulder System as a primary reverse total shoulder replacement and for use when converting an anatomic AETOS Shoulder System into a reverse shoulder construct. This facilitates the conversion without the removal of the humeral stem during revision surgery for patients with a functional deltoid muscle. The component is permitted to be used in the conversion from anatomic to reverse if the humeral stem is well fixed, the patient has a functional deltoid muscle; the arthroplasty is associated with a massive and non-repairable rotator cuff tear.

    The coated humeral stems are indicated for uncemented use. The coated glenoid base plate is intended for cementless application with the addition of screws for fixation.

    Note: All implant components are single use.

    Device Description

    The AETOS Shoulder System Meta Humeral Prosthesis Size 0 subject to this submission is intended for press-fit fixation as of an implant construct in anatomic and/or reverse total shoulder arthroplasty for the treatment of skeletally mature individuals with degenerative diseases of the glenohumeral joint.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252129

    Validate with FDA (Live)

    Date Cleared
    2025-10-03

    (88 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AETOS Shoulder System (when used with the AETOS Humeral Meta Stems) is to be used only in patients with an intact or reconstructable rotator cuff, where it is intended to provide increased mobility and stability and to relieve pain.

    The AETOS humeral stems (AETOS Humeral Meta Stems) and head may be used by themselves, as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with the glenoid, as a total replacement.

    When used with the AETOS Humeral Meta Stems, The AETOS Shoulder System is indicated for use as a replacement of shoulder joints disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The AETOS Shoulder System (when used with AETOS Stemless Humeral Prosthesis) is to be used only in patients with an intact or reconstructable rotator cuff.

    When used with AETOS Stemless Humeral Prosthesis, the AETOS Shoulder System is indicated for anatomic total shoulder replacement of shoulder joints disabled by:

    • Non-inflammatory degenerative joint disease
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The coated humeral components are intended for uncemented use. The glenoid component is intended for cemented use only.

    In Reverse:

    The AETOS Shoulder System, when used with AETOS Humeral Meta Stems, is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with massive and non-repairable rotator cuff-tear with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of devices if sufficient bone stock remains

    The humeral liner component is indicated for use in the AETOS Shoulder System as a primary reverse total shoulder replacement and for use when converting an anatomic AETOS Shoulder System into a reverse shoulder construct. This facilitates the conversion without the removal of the humeral stem during revision surgery for patients with a functional deltoid muscle. The component is permitted to be used in the conversion from anatomic to reverse if the humeral stem is well fixed, the patient has a functional deltoid muscle; the arthroplasty is associated with a massive and non-repairable rotator cuff tear.

    The coated humeral stems are indicated for uncemented use. The coated glenoid base plate is intended for cementless application with the addition of screws for fixation.

    Device Description

    The AETOS Stemless Humeral Prosthesis subject to this submission is a humeral anchor intended for press-fit fixation as part of an implant construct in anatomic total shoulder arthroplasty for the treatment of skeletally mature individuals with degenerative diseases of the glenohumeral joint.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251826

    Validate with FDA (Live)

    Date Cleared
    2025-09-11

    (90 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RENASYS WOUND+ Dressing Kit with AIRLOCK Technology is intended to be used in conjunction with Smith+Nephew traditional Negative Pressure Wound Therapy (tNPWT) RENASYS systems. The Smith+Nephew RENASYS NPWT system is indicated for patients who would benefit from a suction pump (Negative Pressure Wound Therapy), as it allows for wound management via removal of fluids, including irrigation and body fluids, wound exudates and infectious materials. Appropriate wound types for RENASYS WOUND+ Dressing include:

    • Chronic
    • Acute
    • Traumatic
    • Sub-Acute and dehisced wounds
    • Ulcers (such as pressure or diabetic)
    • Partial-thickness burns
    • Flaps
    • Grafts

    RENASYS WOUND+ Dressing without filler can be used on the following additional wound type:

    • Closed surgical incisions

    The RENASYS WOUND+ Dressing Kit with AIRLOCK Technology in Small, Medium, and Large sizes is intended to be used with Smith+Nephew RENASYS TOUCH, RENASYS GO, and RENASYS EDGE NPWT systems.

    Device Description

    RENASYS WOUND+ Dressing kits with AIRLOCK Technology can be used without a wound filler, with foam or with gauze wound filler. The kits are accessories intended for use in conjunction with RENASYS TOUCH, RENASYS GO and RENASYS EDGE Negative Pressure Wound Therapy systems. RENASYS Negative Pressure Wound Therapy allows for wound management via removal of fluids, including irrigation and body fluids, wound exudates and infectious materials.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Smith & Nephew BIORAPTOR◊ Suture Anchor is indicated for the reattachment of soft tissue to bone for the following indications:

    Hip:

    • Hip Capsule Repair
    • Acetabular labrum reattachment/reconstruction

    Shoulder:

    • Capsular stabilization
    • Bankart repair
    • Anterior shoulder instability
    • SLAP lesion repairs
    • Capsular shift or capsulolabral reconstructions
    • Acromioclavicular separation repairs
    • Deltoid repairs
    • Rotator cuff tear repairs
    • Biceps tenodesis

    Foot and Ankle:

    • Hallux valgus repairs
    • Medial or lateral instability repairs/reconstructions
    • Achilles tendon repairs/reconstructions
    • Midfoot reconstructions
    • Metatarsal ligament/tendon repairs/reconstructions
    • Bunionectomy

    Elbow, Wrist, and Hand:

    • Biceps tendon reattachment
    • Ulnar or radial collateral ligament reconstructions
    • Lateral epicondylitis repair

    Knee:

    • Extra-capsular repairs:
      • Medial collateral ligament
      • Lateral collateral ligament
      • Posterior oblique ligament
    • Patellar realignment and tendon repairs
    • Vastus medialis obliquous advancement
    • Iliotibial band tenodesis

    Smith & Nephew BIORAPTOR◊ Curved 2.3 PK Suture Anchors are indicated for the reattachment of soft tissue to bone for the following indications:

    Shoulder:

    • Capsular stabilization
    • Bankart repair
    • Anterior shoulder instability
    • SLAP lesion repairs
    • Capsular shift or capsulolabral reconstructions
    • Acromioclavicular separation repairs
    • Deltoid repairs
    • Rotator cuff tear repairs
    • Biceps tenodesis

    Foot and Ankle:

    • Hallux valgus repairs
    • Medial or lateral instability repairs/reconstructions
    • Achilles tendon repairs/reconstructions
    • Midfoot reconstructions
    • Metatarsal ligament/tendon repairs/reconstructions
    • Bunionectomy

    Elbow, Wrist, and Hand:

    • Biceps tendon reattachment
    • Ulnar or radial collateral ligament reconstructions
    • Lateral epicondylitis repair

    Knee:

    • Extra-capsular repairs:
      • Medial collateral ligament
      • Lateral collateral ligament
      • Posterior oblique ligament
    • Patellar realignment and tendon repairs
    • Vastus medialis obliquous advancement
    • Iliotibial band tenodesis

    The Smith & Nephew BIORAPTOR◊ Suture Anchor is intended for the reattachment of soft tissue to bone.

    The Smith & Nephew BIORAPTOR◊ Curved 2.3 PK Suture Anchor is intended for the reattachment of soft tissue to bone.

    Device Description

    The Smith & Nephew BIORAPTOR 2.3 PK and BIORAPTOR Curved 2.3 PK Suture Anchors are fixation devices intended to provide secure attachment of soft tissue to bone. The devices consist of a suture anchor with attached non-absorbable suture(s) preassembled to an insertion device. The BIORAPTOR Curved 2.3 PK Suture Anchors are preassembled to a flexible insertion device.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the BIORAPTOR Suture Anchors primarily focus on demonstrating substantial equivalence to a predicate device, particularly concerning a packaging modification. As such, the document does not contain the typical acceptance criteria and detailed study data (like sample size, expert consensus, MRMC studies, etc.) that would be found in a submission for a novel or significantly modified AI/medical imaging device.

    The "Performance Data" section specifically mentions non-clinical testing related to the packaging modification. Therefore, I will extract information related to these non-clinical tests and frame them as 'acceptance criteria' and 'reported performance' for the device's packaging.

    Here's the breakdown based on the provided document:


    Acceptance Criteria and Device Performance for BIORAPTOR Suture Anchors (Packaging Modification)

    The described study proves that the modified packaging for the BIORAPTOR Suture Anchors meets the acceptance criteria.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Implied from test types)Reported Device Performance
    Packaging Design VerificationPackaging successfully protects the device from damage and maintains sterility during expected handling, shipping, and storage conditions. (Specific tests typically include drop tests, vibration tests, compression tests, seal integrity tests, etc., though not detailed here).Device met all required specifications for each test.
    Usability EvaluationThe packaging is easily and safely opened by users, allows for aseptic presentation of the device, and the device is easily removed for use.Device met all required specifications for each test.
    Packaging Material StabilityPackaging materials maintain their integrity and protective properties (e.g., barrier to microbial ingress) over the stated shelf life. (Specific tests often involve accelerated aging, real-time aging, and subsequent barrier integrity assessment).Device met all required specifications for each test.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: The document states "Non-clinical testing was completed on the subject device for the proposed packaging modification," but does not specify the exact sample size used for these tests.
    • Data Provenance: The tests are non-clinical, conducted by the manufacturer (Smith & Nephew, Inc.). The document does not specify the country of origin for the data beyond the company's US headquarters (Andover, MA). These were likely prospective tests performed on the new packaging design.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • This information is not applicable to the type of non-clinical, packaging-related testing described. There is no 'ground truth' in the clinical sense (e.g., diagnosis, pathology) that requires expert consensus. The "ground truth" here is the adherence to engineering specifications and performance standards for packaging.

    4. Adjudication Method for the Test Set

    • This information is not applicable as the testing is engineering/laboratory-based for packaging performance, not clinical interpretation of data that would require adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • No, an MRMC study was not done. This type of study is relevant for AI/imaging devices where human readers interpret diagnostic images, often with and without AI assistance. The device in question is a physical suture anchor, and the described studies are non-clinical evaluations of its packaging.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • Not applicable. This concept applies to AI algorithms. The described studies are physical tests of a medical device's packaging.

    7. The Type of Ground Truth Used

    • The "ground truth" for these non-clinical tests is based on pre-defined engineering specifications and performance standards for medical device packaging (e.g., ISO or ASTM standards for sterile barrier systems, shelf life, and shipping integrity). It is not clinical ground truth like pathology or outcomes data.

    8. The Sample Size for the Training Set

    • Not applicable. This concept applies to machine learning models. The tests performed are physical, non-clinical evaluations related to manufacturing and packaging.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. This concept applies to machine learning models.

    Summary of Limitations Based on Document Content:

    The provided document details a 510(k) submission for a suture anchor with a packaging modification. The testing described is therefore focused on demonstrating that this packaging change does not compromise the device's safety, effectiveness, or equivalence to its predicate. The detailed information typically requested for AI/software devices (like expert consensus, MRMC studies, training data details) is not relevant or present in this type of submission for a physical, mechanical device's packaging.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243608

    Validate with FDA (Live)

    Date Cleared
    2025-06-12

    (202 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The subject device can be used with the TRIGEN META-TAN Trochanteric Antegrade Nailing System, TRIGEN TAN FAN Trochanteric Antegrade and Femoral Antegrade Nailing System, and the TRIGEN META-NAIL Retrograde Femoral Nail System therefore the indications for use for all three systems are applicable to the subject TRIGEN Stable Lock Nut & Washer.

    TRIGEN META-TAN Trochanteric Antegrade Nailing System

    The TRIGEN META-TAN Trochanteric Antegrade Nail is indicated for fixation of fractures that occur in and between the proximal third and distal fourth of the femur including simple long bone fractures, severely comminuted, spiral, and segmental fractures, and supracondylar fractures.

    In addition, TRIGEN META-TAN Nails contain holes/slots proximally to accept screws that thread into the femoral head for compression and rotational stability and are indicated for the following: subtrochanteric fractures; intertrochanteric fractures; and intracapsular fractures.

    TRIGEN TAN FAN Trochanteric Antegrade and Femoral Antegrade Nailing System

    Indications for interlocking intramedullary nails include simple long bone fractures; severely comminuted spiral, large oblique and segmental fractures; and nonunions. Interlocking intramedullary nails are indicated for fixation of fractures that occur in and between the proximal and distal third of the long bones being treated.

    In addition to the indications for interlocking intramedullary nails, devices that contain holes/slots proximally to accept screws that thread into the femoral head for compression and rotational stability (e.g. Femoral Antegrade Nail, Trochanteric Antegrade Nail and Femoral/Recon Antegrade Nail) are indicated for the following: subtrochanteric fractures and intertrochanteric fractures.

    TRIGEN META-NAIL Retrograde Femoral Nail System

    The TRIGEN META-NAIL Retrograde Femoral Nail is indicated for fractures of the femur including stable and unstable distal metaphyseal fractures, diaphyseal fractures, intra-articular fractures, and peri-prosthetic fractures.

    Device Description

    The device in scope of this submission is the TRIGEN Stable Lock Nut & Washer.

    The TRIGEN Stable Lock Nut & Washer is intended to be used as an aid to normal fracture healing for fractures that occur in and between the proximal third and distal fourth of the femur including simple long bone fractures, severely comminuted, spiral, and segmental fractures, and supracondylar fractures; simple long bone fractures; severely comminuted spiral, large oblique and segmental fractures; nonunions; for fixation of fractures that occur in and between the proximal and distal third of the long bones being treated; and for fractures of the femur that include stable and unstable distal metaphyseal fractures, diaphyseal fractures, intra-articular fractures, and peri-prosthetic fractures. The TRIGEN Stable Lock Nut & Washer is made from Ti-6Al-4V material. The device is Gamma sterilized and intended for single-use only.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the TRIGEN Stable Lock Nut & Washer does not pertain to an Artificial Intelligence (AI) or machine learning (ML) device. Instead, it describes a mechanical bone fixation appliance.

    Therefore, the requested information regarding acceptance criteria and study details for an AI/ML device (e.g., sample size, data provenance, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth establishment for training and test sets) cannot be extracted or inferred from this document.

    The clearance letter focuses on demonstrating substantial equivalence to predicate devices primarily through non-clinical bench testing:

    • Acceptance Criteria and Reported Device Performance: This document does not present quantitative acceptance criteria or performance metrics in a table format that would be typical for an AI/ML device validating its inferential accuracy (e.g., sensitivity, specificity, AUC). Instead, for this mechanical device, the performance is implicitly demonstrated by the successful completion of the following non-clinical tests:

      • Theoretical Failure Analysis
      • Torque to Failure/Insertion/Extraction Torque Testing and Analysis
      • MR Compatibility per ASTM F2182-19e2, ASTM F2052-15, ASTM F2213-2017, and ASTM F2119-07(2013)
    • Study That Proves the Device Meets Acceptance Criteria: The study that proves the device meets acceptance criteria consists of the non-clinical bench tests listed above. The conclusion states: "The results of the equivalence testing demonstrate that the differences in design of the subject device does not raise any difference in safety or effectiveness as compared to the predicate devices." This implies that the 'acceptance criteria' were met if these tests demonstrated performance comparable to, or better than, the predicate devices without compromising safety or effectiveness.

    In summary, as this is a traditional mechanical medical device, the concepts of acceptance criteria, test sets, ground truth, and study methodologies related to AI/ML device validation are not applicable here.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250677

    Validate with FDA (Live)

    Date Cleared
    2025-04-02

    (27 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Rheumatoid arthritis;
    • Post-traumatic arthritis, osteoarthritis, or degenerative arthritis;
    • Posterior stabilized and constrained knee systems are also indicated for the treatment of unicompartmental replacement or total knee replacement;
    • Posterior stabilized knee systems are designed for use in patients in primary and revision surgery, where the anterior and posterior cruciate ligaments are incompetent and the collateral ligaments remain intact.
    • Constrained knee systems are designed for use in patients in primary and revision surgery, where the posterior cruciate ligament and one or both of the collateral ligaments (i.e. medial collateral and/or lateral collateral ligament) are incompetent.
    Device Description

    The subject insert is a line addition to the LEGION Inserts with JOURNEY Lock (K200407) and has undergone design modifications to provide a new articulating surface that incorporates a flatter lateral plateau and extended medial geometry to match the asymmetry of the tibial baseplate, while maintaining the JOURNEY locking mechanism. The subject LEGION Medial Stabilized Inserts with JOURNEY Lock have a size range of 1-2, 3-4, 5-6, and 7-8mm with thicknesses of 9, 10, 11, 12, 13, 15, 18mm, and come in both left (LT) and right (RT) configurations. The LEGION Medial Stabilized XLPE Inserts with JOURNEY Lock are provided sterile via Ethylene Oxide sterilization and are intended for single use only. The subject inserts are intended to be used with compatible knee systems for total knee arthroplasty in skeletally mature patients with or without bone cement.

    AI/ML Overview

    I am sorry, but based on the provided FDA 510(k) clearance letter for the LEGION Total Knee System, the document does not contain the specific information required to describe the acceptance criteria and the study that proves the device meets those criteria, especially in the context of an AI/human-in-the-loop performance study.

    Here's why the requested information cannot be found in the provided text:

    • Device Type: The cleared device, the "LEGION Total Knee System," is a physical medical device (a knee joint prosthesis), not an AI/software device. The 510(k) is for a hardware modification (a new articulating surface for an insert).
    • Study Type: The document states, "No clinical testing was performed to support safety and effectiveness of the subject device." The testing mentioned is "bench testing" (Tibiofemoral Constraint Testing and Tibiofemoral Contact Area Testing) which applies to the physical properties of the knee implant.
    • AI/Human-in-the-loop: There is no mention of AI, human readers, ground truth establishment by experts, or MRMC studies, as the device is not an AI diagnostic or assistance tool.

    Therefore, I cannot provide a table of acceptance criteria and reported device performance related to AI, nor can I answer questions about sample sizes for AI test sets, expert numbers, adjudication methods, MRMC studies, standalone AI performance, or training set details, as these concepts are not applicable to the cleared device as described.

    The document focuses on demonstrating substantial equivalence of a new knee implant component to existing, legally marketed predicate devices through material and mechanical performance testing.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250571

    Validate with FDA (Live)

    Date Cleared
    2025-03-28

    (30 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CATALYSTEM Femoral Stems are intended for total and partial hip arthroplasty in skeletally mature patients for the following indications:

    Hip components are indicated for individuals undergoing primary surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of degenerative joint disease or any of its composite diagnoses of osteoarthritis, avascular necrosis, and traumatic arthritis.

    Hip components are also indicated for inflammatory degenerative joint disease including rheumatoid arthritis, congenital dysplasia, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques, and fracture-dislocation of the hip.

    The CATALYSTEM Femoral Stems are intended for use without bone cement.

    Device Description

    The purpose of this Special 510(k) is to notify the FDA of Smith & Nephew's intent to market the CATALYSTEM Femoral Stems with additional femoral head compatibility. The CATALYSTEM Femoral Stems were previously cleared by the FDA under K240381.

    The CATALYSTEM Femoral Stems consists of femoral stem implants intended for primary in skeletally mature patients. The CATALYSTEM Femoral Stems are provided sterile to the user via gamma irradiation.

    The subject CATALYSTEM Femoral Stems are comprised of two variants: CATALYSTEM Collared and CATALYSTEM Collarless. Both variants are available in standard and high neck offset options.

    The CATALYSTEM Femoral Stems are intended to be used with Smith & Nephew femoral heads and acetabular components for total hip arthroplasty and hip hemiarthroplasty.

    AI/ML Overview

    This document is a 510(k) clearance letter for the CATALYSTEM Femoral Stems. It primarily addresses the regulatory approval process rather than detailing a study proving the device meets specific acceptance criteria in the context of an AI/software device.

    The provided text does not contain information related to AI/software device performance or studies proving such a device meets acceptance criteria. It describes a medical device (femoral stems for hip replacement) and its regulatory clearance based on substantial equivalence to a predicate device.

    Specifically, it states:

    • "No clinical tests were performed to support safety and efficacy of the subject device."
    • Bench testing was performed for mechanical properties (e.g., fatigue, range of motion, impingement), which are relevant to orthopedic implants, not AI performance.
    • The clearance is a "Special 510(k)" primarily for "additional femoral head compatibility."

    Therefore, I cannot extract the requested information about acceptance criteria and a study proving an AI device meets them from this document. The concepts of ground truth, expert adjudication, MRMC studies, standalone performance, training sets, and test sets are not applicable to the information provided in this 510(k) clearance letter for a mechanical implant.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241666

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-02-19

    (254 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EVOS Pelvic and Acetabular System is indicated for fixation of fractures and/or disruptions of the pelvis and acetabulum in skeletally mature patients.

    Device Description

    The subject EVOS Pelvic and Acetabular System consists of Class II bone plate and screw implants. The subject bone plates are available in a variety of shapes and sizes. The subject screws consist of locking screws as well as cannulated screws. The subject plates are also compatible with the previously cleared EVOS locking screws, and partially and fully threaded osteopenia screws (K140814 S.E. 5/7/2014 and K162078 S.E. 7/27/2016). The proposed plates and screws are manufactured from implant-grade 316L Stainless Steel material and will be available in a sterile packaged condition.

    AI/ML Overview

    I am sorry, but based on the provided text, there is no information about acceptance criteria or a study proving that a device meets those criteria in the context of an AI/ML medical device.

    The document is a 510(k) clearance letter from the FDA for the "EVOS Pelvic and Acetabular System," which is a metallic bone fixation appliance. The clearance is based on substantial equivalence to legally marketed predicate devices, not on the performance of a software algorithm or AI model.

    The "Non-Clinical and/or Clinical Tests Summary & Conclusions" section explicitly states that "No clinical testing was performed on the subject devices." The tests conducted are mechanical and materials testing for the implants (e.g., Finite Element Analysis, fatigue testing, static evaluation of screws, MRI compatibility, and packaging verification), which are standard for orthopedic hardware, not for AI performance.

    Therefore, I cannot provide details on:

    • A table of acceptance criteria and reported device performance (for an AI/ML device)
    • Sample size used for the test set and data provenance (for an AI/ML device)
    • Number of experts and qualifications (for establishing ground truth for an AI/ML device)
    • Adjudication method (for an AI/ML device)
    • Multi-reader multi-case comparative effectiveness study (for an AI/ML device)
    • Standalone performance (for an AI/ML device)
    • Type of ground truth used (for an AI/ML device)
    • Sample size for the training set (for an AI/ML device)
    • How ground truth for the training set was established (for an AI/ML device)

    The document is about a traditional medical device (surgical implants) and does not contain the information requested about AI/ML device performance or studies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243576

    Validate with FDA (Live)

    Date Cleared
    2025-02-18

    (91 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RENASYS Foam and Gauze Wound Dressing Kits with AIRLOCK Technology and Soft Port are intended to be used in conjunction with Smith + Nephew traditional Negative Pressure Wound Therapy (tNPWT) RENASYS system.

    The Smith + Nephew RENASYS NPWT system is indicated for patients who would benefit from a suction pump (Negative Pressure Wound Therapy), as it allows for wound management via removal of fluids, including irrigation and body fluids, wound exudates and infectious materials.

    Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Sub-Acute and dehisced wounds
    • Ulcers (such as pressure or diabetic)
    • Partial-thickness burns
    • Flaps
    • Grafts
    Device Description

    RENASYS Foam and Gauze Wound Dressing Kits with AIRLOCK Technology and Soft Port are accessories intended for use in conjunction with RENASYS TOUCH, RENASYS GO and RENASYS EDGE Negative Pressure Wound Therapy systems.

    AI/ML Overview

    Based on the provided text, the document is a 510(k) summary from the FDA for a medical device called "RENASYS Foam Wound Dressing Kit with AIRLOCK Technology and Soft Port; RENASYS Gauze Wound Dressing Kit with AIRLOCK Technology and Soft Port." This document does not describe an AI/ML device or its performance criteria. It pertains to a physical medical device used for negative pressure wound therapy.

    Therefore, I cannot provide the requested information as the document does not contain details regarding acceptance criteria for an AI/ML device, nor does it describe a study proving such a device meets those criteria. The original text only mentions non-clinical tests (simulated wound model tests, human factors validation, biological evaluation) and explicitly states "No clinical performance data was necessary" for this particular device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242146

    Validate with FDA (Live)

    Date Cleared
    2024-12-17

    (147 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BIOBRANE Dressings are indicated for:

    • Covering clean partial thickness burn wounds
    • Split thickness donor sites

    BIOBRANE Glove is indicated for:

    • Covering clean partial thickness burn wounds of the hand.
    Device Description

    BIOBRANE Dressing and BIOBRANE Glove are wound dressings made from an ultrathin, semipermeable, perforated silicone membrane that is mechanically bonded to a flexible knitted tri-filament nylon fabric. Denatured porcine dermal collagen is bonded to the silicone-nylon membrane to provide a flexible and conformable dressing with adherence properties and a hydrophilic surface.

    AI/ML Overview

    This document is a 510(k) K242146 premarket notification for the BIOBRANE Dressing and BIOBRANE Glove. It asserts substantial equivalence to the predicate device BIOBRANE II (K901369).

    Here's an analysis of the provided information relating to acceptance criteria and device performance:

    1. Table of Acceptance Criteria and Reported Device Performance

    The submission does not provide a table of acceptance criteria with specific performance metrics such as sensitivity, specificity, accuracy, or any quantitative measures for the device's diagnostic or predictive capabilities. This is likely because the device is a wound dressing, not a diagnostic AI/ML device.

    Instead, the submission focuses on demonstrating substantial equivalence to a predicate device through shared characteristics and verification tests. The "acceptance criteria" can be inferred as successful completion of these tests and demonstration that the device's characteristics are similar to the predicate.

    Characteristic / TestAcceptance Criteria (Inferred)Reported Device Performance
    Intended UseSame as predicateSame
    Indications for UseWithin scope of predicate's indicationsMore precise, but substantially equivalent
    Principles of OperationSame as predicateSame
    Materials and StructureSame as predicateSame (Silicone membrane, nylon, collagen)
    Silicone Membrane FunctionSame as predicateSame
    Nylon FunctionSame as predicateSame
    Collagen FunctionSame as predicateSame
    Principal OperatorSame as predicateSame (Trained HCP only)
    Environment of UseSame as predicateSame (Healthcare facility and home use)
    Single-Use or ReusableSame as predicateSame (Single-Use)
    SterilizationSame as predicateSame (Moist heat)
    SterilitySame as predicateSame (Sterile, SAL 10-6)
    Shelf LifeSame as predicateSame (3 years)
    BiocompatibilityComplies with ISO 10993Complies with ISO 10993
    Device DimensionsEquivalent to predicate sizesEquivalent to predicate sizes
    Anatomical sitesSame as predicateSame
    Bench Performance Verification TestsMeets design specificationsCompleted and confirm specifications met
    Product CharacterizationConfirms product characteristicsCompleted and confirm characteristics

    2. Sample Size Used for the Test Set and Data Provenance

    The document explicitly states: "No clinical data is relied upon in this submission to determine substantial equivalence."

    Therefore:

    • Sample size for the test set: Not applicable, as no clinical test set was used for substantial equivalence determination.
    • Data provenance: Not applicable. The evaluation was based on non-clinical (bench) testing and comparison of technological characteristics.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable, as no clinical test set with a ground truth established by experts was used. The substantial equivalence was based on non-clinical data and direct comparison to a predicate device.

    4. Adjudication Method for the Test Set

    Not applicable, as no clinical test set was used requiring adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not performed or relied upon. This is a wound dressing, not an AI/ML diagnostic device where such studies are typical.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This device is a wound dressing, not an algorithm or software-only device.

    7. The Type of Ground Truth Used

    Not applicable, as no clinical data or ground truth in the context of diagnostic performance was used. The "ground truth" for this submission is implicitly the established safety and efficacy profile of the legally marketed predicate device (BIOBRANE II, K901369) and the physical/chemical properties assessed through bench testing.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/ML device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. This is not an AI/ML device that requires a training set or ground truth for training.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 62