Search Filters

Search Results

Found 8 results

510(k) Data Aggregation

    K Number
    K221789

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-08-09

    (49 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    IRIS Pi Q switched Nd YAG laser system is indicated for the Incision, Excision, Ablation Vaporization of soft tissues for general dermatologic and general surgery procedures for Coagulation and Hemostasis

    532nm wavelength

    Tattoo removal light ink (red, tan, purple, orange, sky blue) Removal of benign epidermal pigmented lesions, Minor benign vascular lesions, Talangietasias Treatment of Lentigines, Cafe-Au-Lait, Sebrorrheic Keratoses, Becker's Nevi, Freckles. Treatment of Post inflammatory Hyperpigmentation ( PIH)

    1064nm wavelength

    Tattoo removal dark ink (black, blue, green) Removal of Nevus of Ota, Removal or lightening of unwanted hair, Treatment of Common Nevi, Melasma Skin resurfacing procedures for treatment of Acne Scars, Wrinkle

    Device Description

    The IRIS Pi O-Switched Nd:YAG laser system produces a two pulsed beam, 1064 nm Infrared and 532nm long pulse laser, and using two non-fractional handpieces (Zoom handpiece and 7mm collimated handpiece) is able to control various treatment fluence.

    laser tube : placed in the mixed crystals of copper pipe to the heater and produces a laser beam, Resonator : amplifies the beam, through the Xe-gas contained lamp : Xe-gas contains high pressure lamp to increase specific laser beam lamp

    This converted light energy creates the Nd: Y AG crystal and exhaust from the crystal is amplified into a specific wave length. Laser energy produced is delivered to the tissue by means of an articulated arm and a specially designed adjustable spot size Hand Piece.

    The Physician can optimize the effect for different applications by controlling the energy of the laser pulse and the spot size of the treatment beam, and is able to activate laser emission using Foot Switch. Laser parameters and other system features are controlled from a display panel located on the front of the power supply unit.

    This system also consist of

    Optic main Bench assembly, Articulated Arm Hand pieces, LCD control panel, Cooling system, Foot Pedal Switch

    AI/ML Overview

    This document is a 510(k) summary for the IRIS Pi Q-switched Nd:YAG laser, comparing it to a predicate device (K171648 BM.IRIS Nd:YAG). It does not describe acceptance criteria or a study proving the device meets said criteria in the way typically expected for an AI/CADe device. Instead, it focuses on demonstrating substantial equivalence to a legally marketed predicate device through technical specifications and adherence to general safety and performance standards for laser medical devices.

    Therefore, many of the requested sections about acceptance criteria, device performance, sample sizes, ground truth establishment, expert involvement, and MRMC studies are not applicable to this type of submission, as it's not for a diagnostic AI/CADe device.

    Here's an analysis based on the provided text, addressing the applicable points and explicitly stating when information is not present:

    Summary of Acceptance Criteria and Device Performance (Not Applicable - Device is a laser, not AI/CADe)

    This submission does not provide acceptance criteria in the typical sense for an AI/CADe or diagnostic device, nor does it report specific device performance metrics against such criteria. The device is a laser system, and its "performance" is assessed by comparing its technical specifications to those of a predicate device and by demonstrating adherence to international safety standards for laser products.


    1. A table of acceptance criteria and the reported device performance

    As this is a laser surgical instrument, the "acceptance criteria" are primarily related to safety and efficacy as demonstrated through substantial equivalence to a predicate device and compliance with relevant international standards. There are no specific performance metrics like sensitivity, specificity, or AUC mentioned in the context of diagnostic decision-making that would be typically found for an AI/CADe device.

    Here's a table based on the comparison to the predicate device, highlighting differences that were reviewed for safety and effectiveness:

    CharacteristicAcceptance Criteria (Predicate Device K171648)Reported Device Performance (K221789 IRIS Pi)Comment
    Laser TypeNd YAGNd YAGSame
    Wavelength1064/532 nm1064/532 nmSame
    Operating ModeQ-switchedQ-switchedSame
    Mode Names1064, 532, SLP, BLUE Toning1064, 532, SLP, BLUE TSame
    Max Pulse Energy (mJ)1200 @ 1064 nm (Q)1600 @ 1064 nm (Q)Different
    400 @ 532 nm (Q)500 @ 532 nm (Q)Different
    1500 @ 1064 nm (SLP)2000 @ 1064 nm (SLP)Different
    1000 @ 1064 nm (Blue Toning, PTP)1500 @ 1064 nm (BLUE T)Different
    Spot Size (mm)2-10 @ 1064 nm2-10 @ 1064 nmSame
    1.5-8 @ 532 nm2-10 @ 532 nmComparable
    Pulse Duration (ns)5-10 nm (all modes)5-10 nm (all modes)Same
    Repetition Rate (Hz)10-20 @ 1064/532 nm (Q)1-10 @ 1064/532 nm (Q)Different
    10-20 @ 1064 nm (SLP)1-10 @ 1064 nm (SLP)Different
    10-20 @ 1064 nm (Blue Toning, PTP)1-15 @ 1064 nm (BLUE T)Different
    Aiming Beam<3 mW @ 655 nm<3 mW @ 655 nmSame
    Cooling SystemWater coolingWater coolingSame
    Dimensions295 x 740 x 1680 mm270 x 700 x 750 mmComparable
    Weight70 kg90 kgComparable

    Conclusion stated in the document: The differences in Maximum Pulse Energy and Repetition Rate "are not expected to significantly alter the safety and effectiveness of the subject device compared to the predicate device" because "the maximum repetition rate for the subject device is lower than that of the predicate device, the energy delivered by the subject device is lower than or comparable to the predicate device."


    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not Applicable. This submission is for a laser surgical instrument, not an AI/CADe device that relies on a "test set" of medical images or patient data to evaluate algorithmic performance. The evaluation is based on technical specifications and adherence to performance standards.
    • The document states: "Clinical data is not required in this submission".

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not Applicable. As no clinical data or "test set" was used to evaluate a diagnostic or AI algorithm, there was no need for experts to establish ground truth in this context.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable. No test set or human adjudication was performed for this laser device submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is not an AI/CADe device, and therefore no MRMC study or evaluation of human reader improvement with AI assistance was performed or is relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This is a physical laser device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not Applicable. As no diagnostic claims or AI/CADe functionality are involved, "ground truth" in the traditional sense of medical image analysis is not established for this device. The 'truth' in this context is adherence to fundamental engineering and safety standards for laser devices.

    8. The sample size for the training set

    • Not Applicable. This is a hardware device, not an AI model, and therefore does not have a "training set."

    9. How the ground truth for the training set was established

    • Not Applicable. No training set was used.

    Performance Tests Conducted (from section 8 of the 510(k) Summary):

    The device's performance and safety were demonstrated by compliance with the following mandatory and voluntary standards:

    • AAMI/ANSI ES60601-1:2005® 2012 And A1:2012: General requirement for basic safety and essential performance.
    • IEC60601-1-2: 2014: Electro Magnetic Compatibility test.
    • IEC60601-2-22: Part 2, Particular requirements for safety of diagnostic and Therapeutic laser.
    • IEC60825-1: 2nd ED: Equipment classification and requirement.
    • IEC60601-2 Part 6: General requirements for safety - Collateral Standard: Usability.
    • Software Verification and Validation test: Conducted and documentation provided as recommended by FDA guidance and IEC62304. Results found acceptable for software release.
    • Biocompatibility: The device uses non-contact mode, and the handpiece tips are made of SS.304, same as the predicate device.

    These tests serve as the "study" proving the device's acceptable performance in terms of safety and adherence to recognized standards for laser medical devices, supporting its substantial equivalence claim.

    Ask a Question

    Ask a specific question about this device

    K Number
    K212082

    Validate with FDA (Live)

    Device Name
    Picore
    Manufacturer
    Date Cleared
    2021-10-06

    (96 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PICORE Q-switched Nd : Y AG Laser System is indicated for the incision, ablation, vaporization of soft tissues for general dermatology, dermatologic and general surgical procedures for coagulation and hemostasis.

    532nm Wavelength
    Tattoo removal light ink (red, tan, purple, orange, sky blue) Removal of Benign Epidermal Pigmented Lesions, Minor Benign Vascular Lesions. Talangiectasias Treatment of Lentigines, Cafe-Au-Lait, Sebrorrheic Keratoses, Becker's Nevi, Freckles Treatment of Post Inflammatory Hyperpigmentation (PIH)

    1064nm Wavelength:
    Tattoo removal: dark ink (black, blue, green) Removal of Nevus of Ota, Removal or lightening of unwanted hair with or without adjuvant preparation Treatment of Common Nevi, Melasma, Skin resurfacing procedures for the treatment of acne scars. wrinkle

    Device Description

    The subject device PICORE is a picosecond Nd:Y AG laser instrument that uses Nd:YAG as a medium to emit a laser beam of 1064nm and 532nm wavelength. It has four non-fractional handpieces (Zoom handpiece, 7mm collimated handpiece, 3-5 mm handpiece, 6-8 mm handpiece). A physician can optimize the treatment effect for different applications by controlling the energy of the laser pulse and the spot size of the treatment beam. Laser emission can be controlled by using a Foot Switch. Laser parameters and other system features are controlled from a display panel located on the front of the power supply unit.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of acceptance criteria with corresponding performance metrics. Instead, it relies on demonstrating substantial equivalence to a predicate device (BM.IRIS, K171648) by showing that its technical specifications are comparable and that it passed relevant non-clinical testing standards.

    However, we can infer the "acceptance criteria" through the comparison to the predicate device and the non-clinical testing performed.

    Acceptance Criteria (Inferred)Reported Device Performance (PICORE, K212082)
    Technical Specifications Comparable to Predicate Device (BM.IRIS, K171648):
    Laser TypeNd:YAG (Same as predicate)
    Wavelength (nm)1064/532 (Same as predicate)
    Operating ModeQ-switched, Pulsed (Same as predicate)
    Spot size (mm)2-10 @ 1064nm, 2-10 @ 532nm (Comparable to predicate's 2-10 @ 1064nm, 1.5-8 @ 532nm)
    Maximum Pulse Energy (mJ)50-800 @ 1064nm (Q), 5-300 @ 532nm (Q), 50-800 @ Blue Fx, 50-800 @ Blue T (Different from predicate's 1200 @1064nm (Q), 400 @ 532nm (Q), etc., but noted as "different & subset" with an implication of maintaining safety/effectiveness).
    Maximum Pulse Power (GW)800 mJ/450ps = 1.8 GW (Different from predicate's 1200 mJ/5ns = 0.24 GW, but deemed not to significantly alter safety/effectiveness).
    Pulse Duration450 ps @ 1064nm, 380 ps @ 532nm, 450 ps @ Blue Fx, 450 ps @ Blue T (Different from predicate's 5-10ns, but deemed not to significantly alter safety/effectiveness).
    Repetition Rate (Hz)1-10 (Different from predicate's 10-20, but noted as "different & subset" with an implication of maintaining safety/effectiveness).
    Aiming Beam<3 mW @ 655 nm (Same as predicate)
    LCD Display10.4" touch screen (Same as predicate)
    CoolingClosed circuit water to air (Same as predicate)
    Power Consumption3kVA (Same as predicate)
    Dimensions290mmX794mmX934mm (Comparable to predicate's 295mmX740mmX1680mm)
    Weight60 kg (Comparable to predicate's 70 kg)
    Compliance with Non-Clinical Standards:
    Basic Safety & Essential Performance (IEC 60601-1)Met (Test conducted)
    Laser Product Safety (IEC 60825-1)Met (Test conducted)
    Electromagnetic Compatibility (IEC 60601-1-2)Met (Test conducted)
    Software Validation & VerificationMet (Test conducted)
    Bench Testing to Verify PerformanceMet (Test conducted)
    Biocompatibility: (Not performed, rationale provided)Not applicable: Handpieces do not touch patients and are identical to the predicate device.
    No Significant Alteration in Safety and Effectiveness due to Technical Differences from PredicateThe document explicitly states: "The difference in technological parameters is not expected to significantly alter the safety and effectiveness of the subject device compared to the predicate device." This is the overarching acceptance criterion for substantial equivalence.

    2. Sample Size for the Test Set and Data Provenance

    • Sample Size for Test Set: Not applicable. No clinical or standalone performance studies were conducted that would involve a "test set" of patients/data in the typical sense for an AI/diagnostic device. The testing was non-clinical (bench testing, standards compliance).
    • Data Provenance: Not applicable. The testing was primarily against hardware/software standards and direct comparison of specifications, not clinical data or patient samples.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Number of Experts: Not applicable. Since no clinical study or data-driven performance test was conducted on a "test set" requiring ground truth, no experts were used for this purpose in the context of this submission.
    • Qualifications of Experts: Not applicable.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not applicable. No clinical or data-driven test set requiring adjudication was used.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • MRMC Study: No, an MRMC comparative effectiveness study was not done.
    • Effect Size of Human Readers with AI vs. without AI assistance: Not applicable, as no such study was conducted.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    • Standalone Performance Study: No, a standalone performance study (algorithm only) was not conducted. The device is a laser system, not an AI or diagnostic algorithm, and its performance is evaluated through technical specifications and safety standards, not an "algorithm only" assessment.

    7. The Type of Ground Truth Used

    • Type of Ground Truth: Not applicable in the context of clinical outcomes or diagnostic accuracy. For the non-clinical testing, the "ground truth" was established by engineering specifications, recognized international safety and performance standards (IEC standards), and the technical characteristics of the legally marketed predicate device.

    8. The Sample Size for the Training Set

    • Sample Size for Training Set: Not applicable. This device is a laser system, not a machine learning or AI-driven diagnostic device that typically requires a "training set" of data.

    9. How the Ground Truth for the Training Set was Established

    • Ground Truth for Training Set: Not applicable, as no training set was used.
    Ask a Question

    Ask a specific question about this device

    K Number
    K182270

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2018-11-02

    (72 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cellene CO2 laser system is indicated for use in surgical applications requiring the ablation, vaporization, excision,incision, and coagulation of soft tissue in medical specialties including: aesthetic surgery (dermatology and plastic surgery), podiatry, gynecology, neurosurgery, orthopedics (soft tissue), arthroscopy (knee).

    The Cellene Co2 Laser system is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin.

    The Standard Handpiece of the Cellene Co2 System is indicated for the following:
    Dermatology & Plastic Surgery:
    The ablation, vaporization, excision, incision, and coagulation of soft tissue in dermatology and plastic surgery in the performance of: laser skin resurfacing, laser dermabrasion, laser burn debridement. Laser skin resurfacing (ablation and/or vaporization) for the treatment of: wrinkles, rhytids, and furrows (including fines lines and texture irregularities) Clinical literature demonstrates that skin resurfacing of wrinkles, rhytids, and furrows with CO2 laser increases the amount of sub-epidermal collagen.
    Laser skin resurfacing (ablation and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of:
    keratoses, including actinic and seborrheic keratosis, seborrhoecae vulgares, seborrheic wart, and verruca seborrheica; vermillionectomy of the lip; cutaneous horns; solar/actinic elastosis; chelitis, including actinic chelitis; lentigines, including lentigo maligna or Hutchinson's malignant freckle, uneven pigmentation/ dyschromia; acne scars; surgical scars; keloids including acne keloidalis nuchae; hemangiomas (including Buccal, port wine and pyogenic granulomas/granuloma pyogenicum/granuloma telagiectaticum); tattoos; telangiectasia; removal of small skin tumors, including periungual (Koenen) and subungual fibromas; superficial pigmented lesions; adenosebaceous hypertrophy or sebaceous hyperplasia, rhinophyma reduction, cutaneous papilloma (skin tags); milia; debridement of eczematous or infected skin: basal and squamous cell carcinoma, including keratoacanthomas, Bowen's disease (Erythroplasia of Queyrat), and Bowenoid Papulosis (BP) lesions; nevi, including spider, epidermal and protruding; neurofibromas; laser de-epithelialization; tricoepitheliomas; xanthelasma palpebrarum; syringoma laser ablation, vaporization for complete or partial nail matrixectomy. Vaporization of: benign/malignant vascular/avascular/avascular skin lesions; Verrucae and seborrhoecae vulgares, including paronychial, periungal, and subungual wart.

    Podiatry
    Laser ablation, vaporization and /or excision of soft tissue for the reduction, removal, and/or treatment of: Verrucae, vulgares / plantars(warts), including paronychial, periungal, and subungual warts, fungal nail treatment, porokeratoma ablation; ingrown nail treatment; neuromas/fibromas,
    including morton's neuroma, debridement of ulcers, and other soft tissue lesions.
    Laser ablation, vaporization and / or excision in podiatry for complete or partial matrixectomy.

    Otolaryngology (ENT)
    Laser incision, excision, ablation and/or vaporization of soft tissue in otolaryngology the treatment of: leukoplakia, including oral, larynx, uvula, palatal, upper latera pharyngeal tissue; nasal obstruction; x adult and juvenile papillomatosis polyps; x polypectomy of nose and nasal passages; lymphangioma removal; removal of recurrent papillomas in the oral cavity, nasal cavity, larynx, pharynx and trachea, including the uvula, palatal, upper lateral pharyngeal - tissue, tongue and vocal cords; superficial lesions of the ear, including chondrodermatitis nodularis chronica helices/Winkler's disease; rhinophyma; verrucae vulgares (warts);

    Gynecology (GYN)
    Laser incision, excision, ablation and/or vaporization and of soft tissue in gynecology (GYN) for the treatment of conization of the cervix, including cervical intraepithelial neoplasia (CIN), vulvar and vaginal intraepithelial neoplasia (VIN, VAIN); condyloma acuminate, including cervical, genital, vulvar, perineal, and Bowen's disease, (Erythroplasia of Queyrat) and Bowenoid papulosa (BP) lesions; leukoplakia (vulvar dystrophies); herpes vaporization, urethral caruncle vaporization, cervical dysplasia, Benign and malignant tumors.

    Dental/Oral Surgery
    Incision/excision and vaporization of soft tissue in dentistry and oral surgery. Applications include: treatment of ulcerous lesions, including aphthous ulcers, excision and ablation of benign and malignant lesions; leukoplakia,

    Genitourinary
    Incision/excision and vaporization and of soft tissue in genitourinary procedures.
    Applications include. benign and malignant lesions of external genitalia, condyloma. erythroplasia

    The Fractional Handpiece of the Cellene System is indicated for dermatological procedures requiring ablation, coagulation and resurfacing of soft tissue, including skin.

    The Surgical Handpiece of the Cellene Co2 laser System is
    Indicated for the following
    Dermatology & Plastic Surgery
    Laser skin resurfacing (ablation and/or vaporization) of soft tissue for the reduction, removal, and/or treatment of:
    vermillionectomy of the lip; cutaneous horns; removal of small skin tumors, including periungual (Koenen) and subungual fibromas; rhinophyma reduction, basal and squamous cell carcinoma, including keratoacanthomas, Bowen's disease (Erythroplasia of Queyrat), and Bowenoid Papulosis (BP) lesions; neurofibromas
    Laser ablation, vaporization and /or excision for complete or partial nail matrixectomy. Vaporization/coagulation of:
    benign/malignant vascular/avascular skin lesions: Moh's Surgerv: Lipectomy: Verrucae and seborrhoecae vulgares, including paronychial, periungal, and subungual warts. Laser incision and /or excision of soft tissue for the performance of upper and lower eyelid blepharoplasty. Laser incision and /or excision of soft tissue for the creation of recipient sites for hair transplantation.

    Podiatry
    Laser ablation, vaporization and /or excision of soft tissue for the reduction, removal, and/or treatment of: verrucae vulgares/plantar (warts), including paronychial, periungal, and subungual warts; Laser ablation, vaporization and /or excision in podiatry for complete or partial matrixectomy.

    Otolaryngology (ENT)
    Laser incision, excision, ablation and/or vaporization of soft tissue in otolaryngology the treatment of, choanal atresia, nasal obstruction; adult and juvenile papillomatosis olyps, polypectomy of nose and nasal passages; lymphangioma removal, removal of vocal cord/fold nodules, polyps and cysts; x removal of recurrent , papillomas in the oral cavity, nasal cavity, larynx and trachea, including the uvula, palatal, upper lateral pharyngeal tissue, tongue and vocal cords;, laser/tumor surgery in the larynx, pharynx, nasal, ear and oral structures and tissue, Zenker's Diverticulum/pharyngoesophageal diverticulum [endoscopic laser- assisted esophagodivertuculostomy (ELAED)]; stenosis, including subglottic stenosis, tonsillectomy (including tonsillar cryptolysis, neoplasma) and tonsil ablation/tonsillotomy, pulmonary bronchial and tracheal lesion removal, benign and malignant nodules, tumors and fibromas (larynx, pharynx, trachea, tracheobronchial/endobronchial); benign and malignant lesions and fibromas (nose and nasal passages); benign and malignant tumors and fibromas (oral) stapedotomy / stapedectomy, acoustic neuroma in the ear; superficial lesions of the ear, including chondrodermatitis, nodularis chronica helices/Winkler's disease, telangiectasia/hemangioma of larynx, pharynx and trachea (includes uvula, palatal or upper lateral pharyngeal tissue); cordectomy, cordotomy (for the treatment of vocal fold paralysis/vocal fold motion impairment), and cordal lesions of larynx, pharynx and trachea,
    myringotomy/tympanostomy (tympanic membrane fenestration), vulopalatoplasty (LAUP, laser UPPP); turbinectomy and turbinate reduction/ablation, septal spur ablation/reduction and septoplasty, x partial glossectomy; x tumor resection on oral, subfacial and neck tissues, thimophyma, verrucae vulgares (warts), Gingivoplasty / Gingivoctomy ..

    Gynecology (GYN)
    Laser incision, excision, ablation and/or vaporization and of soft tissue in gynecology (GYN) for the treatment of:
    conization of the cervix, including cervical intraepithelial neoplasia (CIN), vulvar and vaginal intraepithelial neoplasia (VIN, VAIN), condyloma acuminate, including cervical, genital, vulvar, perineal, and Bowen's disease, (Erythroplasia of Queyrat) and Bowenoid papulosa (BP) lesions, incision and drainage (1&D) of Bartholin's and nubuthian cysts, benign and malignant tumors; hemangiomas.

    GYN Laparoscopy
    Vaporization, incision, excision, ablation, or photocoagulation of soft tissue in endoscopic and laparoscopic surgery, including GYN laparoscopy, for treatment of:
    endometrial lesions, including ablation of endometriosis; excision / lysis of adhesions salpingostomy, oophorectomy/ovariectomy, fimbrioplasty, metroplasty, microsurgery (tubal);, uterine myomas and fibroids; ovarian fibromas and follicle cysts, uterosacral ligament ablation; hvsterectomy.

    Neurosurgery
    Laser incision, excision, ablation and/or vaporization and of soft tissue in neurosurgery for the treatment of: Cranial
    posterior fossa tumors; x peripheral neurectomy, benign and malignant tumors and cysts (e.g. gliomas, menigiomas (including basal tumors), acoustic neuromas, lipomas and large tumors); arteriovenous malformation, pituitary gland tumors (transphenoidal approach). Spinal Cord incision/excision and vaporization of benign and malignant tumors and cysts, intra- and extradural lesions; laminectomy / laminotomy/ microdiscectomy.

    Orthopedics
    Incision/excision and vaporization and of soft tissue in orthopedic surgery. Applications include: Arthroscopy
    Xmenisectomy, chondromalacia, chondrolasty, ligament release ( lateral and other) excision of plica, partial synovectomy. debridement of traumatic wounds; debridement of decubitus and diabetic ulcers, microsurgery. artificial joint revision; PMMA removal.

    General/Thoracic Surgery
    Incision, excision and vaporization and of soft tissue in general and thoracic surgery including endoscopic and open procedures. Applications include:
    debridement of decubitus ulcers, stasis, diabetic and other ulcers; mastectomy; debridement of bums; rectal and anal hemorrhoidectomy; breast biopsy; reduction mammoplasty; cytoreduction for metastatic disease, laparotomy and laparoscopic applications; mediastinal and thoracic lesions and abnormalities; skin tag vaporization, atheroma, cysts, including sebaceous cysts, pilar cysts, and mucous cysts of the lips; pilonidal cyst removal and repair; abscesses; other soft tissue applications.

    Dental/Oral Surgery
    Incision/excision and vaporization of soft tissue in dentistry and oral surgery. Applications include: gingivectomy- removal of hyperplasias; gingivoplasty; incisional and excisional biopsy, incision of infection when used with antibiotic
    therapy;, frenectomy (frenum release); excision and ablation of benign and malignant lesions, homeostasis, operculectomy, crown lengthening; removal of soft tissue, cysts and tumors, oral cavity tumors and hemangiomas; abscesses, extraction site hemostasis, salivary gland pathologies, preprosthetic gum preparation, partial glossectomy; periodontal gum resection

    Genitourinary
    Incision/excision and vaporization and of soft tissue in genitourinary procedures. Applications include:
    benign and malignant lesions of external genitalia, condyloma, phimosis, Erythroplasia.

    Device Description

    The Cellene Co2 Laser system is a computer controlled Radio Frequency system that delivery Co2 energy to the target treatment area at 10,600nm wave length using three different Handpieces (Standard, Fractional and Surgical), This Co2 laser energy is absorbed by water in tissue to achieve its intended treatment effects. and system consist of,
    laser tube : placed in the mixed crystals of copper pipe to the heater and produces a laser beam,
    Resonator : amplifies the beam, through the Xe-gas contained lamp : Xe-gas contains high pressure lamp to increase specific laser beam lamp
    This converted light energy creates the C02 laser and exhaust from the crystal and amplified into a specific wave length. Laser energy produced is delivered to the Tissue by means of an articulated arm and a specially designed Hand Piece.
    The Physician can optimize the effect for different applications by controlling the energy of the laser pulse and the spot size of the treatment beam, and is able to activate laser emission using Foot Switch. Laser parameters and other system features are controlled from a display panel located on the front of the power supply unit.
    This system also consist of
    Optic main Bench assembly, Articulated Arm, 3 Hand pieces, LCD control panel, Cooling system, Foot Pedal Switch,

    AI/ML Overview

    The provided text is a 510(k) Summary for the Cellene CO2 Laser System. This document focuses on demonstrating substantial equivalence to a predicate device rather than detailing specific clinical studies with acceptance criteria and performance metrics for the Cellene CO2 Laser System itself. It primarily lists the device's intended uses and references standards compliance for safety and essential performance.

    Therefore, the requested information regarding acceptance criteria and a study proving the device meets those criteria, particularly with details about sample size, data provenance, expert qualifications, ground truth establishment, MRMC studies, or standalone algorithm performance, is not available in the provided text.

    The document explicitly states: "Clinical test data is not provided in this submission."

    However, I can extract the information that is present:

    1. A table of acceptance criteria and the reported device performance

    As stated above, no specific performance acceptance criteria or clinical performance data for the Cellene CO2 Laser System is provided. The submission relies on demonstrating substantial equivalence to a predicate device (K103501 Pixel Co2 System Alma Lasers Inc.) based on similar characteristics and compliance with general safety and performance standards.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not provided, as clinical test data was not included.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not provided, as clinical test data was not included.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not provided, as clinical test data was not included.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not done, as clinical test data was not included. The device is a surgical laser, not an AI or diagnostic imaging device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable/done. The Cellene CO2 Laser System is a physical surgical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not provided, as clinical test data was not included.

    8. The sample size for the training set

    Not applicable, as clinical test data was not included and the device is not an AI/machine learning system that requires a "training set."

    9. How the ground truth for the training set was established

    Not applicable, for the same reasons as above.

    Additional details available from the document (regarding general safety and performance, not clinical efficacy):

    The device claims to meet the following standards, which can be considered "acceptance criteria" for basic safety and performance, although specific performance metrics against these standards are not detailed in this summary:

    • IEC60601-1 part 1: General requirement for basic safety and essential performance
    • IEC60601-1-2: 2007: Electro Magnetic Compatibility test
    • IEC60601-2-2: Performance of high frequency surgical equipment and accessories
    • IEC60601-2-22: Performance of Surgical, Cosmetic, Therapeutic and Diagnostic laser
    • IEC60601-1 Part 1-6: General requirement for safety-Collateral Standard: usability
    • IEC60825-1, 2nd Ed Part 1: Equipment classification and requirements
    • IEC62304: Medical device software- Software life-cycle processes
    • Accelerated Aging test of Electrosugrical system electrode hand controlled, general-purpose, single use

    Biocompatibility Testing:

    For parts having direct contact with patients (Hand Piece Probe, made of PC (Polycarbonate), limited contact < 24 hrs), the following tests were performed in compliance with ISO10993:

    Test ItemTest and controlResultStandard
    Cytotoxicity StudyL-929CellsPassISO10993-5
    Maximization / SensitizationPolarPassISO10993-10
    Intracutaneous Reactivity StudyPolarPassISO10993-10

    Sterilization: The device is stated to be non-sterilized.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163638

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-05-15

    (143 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This device indicated for use the Incision, Alblation, Vaporization and Hemostasis of oral soft tissue such as, Excisional and Incisional biopsies, Exposure of Un-erupted teeth, Fibroma Removal, Frenectomy and Frenotomy, Gingival troughing for crown impressions, Gingivectomy, Gingvioplasty, Gingival Incision and Excision, Implant recovery, Incision and drainage of abscess, Leukoplakia, Operculectomy, Oral Papillectomies, Pulpotomy, Pulpotomy as an adjunct to root canal therapy, Reduction of gingival hypertrophy, Soft tissue crown lengthening, Sulcular debridement, Treatment of aphthous ulcers Vestibuloplasty, Biopsy incision and excision, lesion (tumor) removal, Light activation for bleaching material, for laser assisted bleaching/ whitening for teeth.

    Device Description

    Dental 5 multi Diode laser system are producing 81

    AI/ML Overview

    The provided document is a 510(k) premarket notification letter from the FDA for a dental laser device. It does not contain any information regarding acceptance criteria or a study that proves the device meets those criteria.

    The document explicitly states:

    • "Clinical and Non-Clinical performance test data was not provided in this submission." (See page 4, Section 6. Performance test)

    Therefore, I cannot extract the requested information from this document. The device's substantial equivalence to a predicate device was based on similarities in design, construction, energy rate, pulse duration, cooling system, and intended use, along with adherence to mandatory and voluntary standards (IEC 60601-1, IEC 60601-1-2, IEC 60601-2-22, IEC 60825-1, IEC 62304) and sterilization/disinfection validations.

    To answer your request, clinical and non-clinical performance test data would be required, which is absent from this submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K142332

    Validate with FDA (Live)

    Device Name
    BT-400
    Manufacturer
    Date Cleared
    2015-03-20

    (212 days)

    Product Code
    Regulation Number
    880.5700
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BT-400 is the Phototherapy unit intended for the treatment of Neonatal Hyperbilirubinemia caused by Indirect Hyperbilirubinemia.

    Device Description

    BT-400 Neonatal phototherapy is designed to emit the blue light wave length range 450-470nm spectrum to treat Neonatal Jaundice to use in Bassinets, Incubators, Open beds or Radiant warmer and consists of Head ( Light Source ) Control box with LCD window Roll Stand ( optional)

    AI/ML Overview

    This document describes the premarket notification (510(k)) for the BT-400 Neonatal Phototherapy device. It compares the device to a predicate device, the BILI-THERAPY Spot type (K103828), to establish substantial equivalence.

    Here's an analysis of the acceptance criteria and study information provided:


    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state "acceptance criteria" in the sense of predefined thresholds for a study outcome. Instead, it compares the proposed device's performance to that of a legally marketed predicate device to demonstrate substantial equivalence. The "acceptance criteria" here are implied to be that the proposed device performs comparably to or better than the predicate device across key technical and functional characteristics.

    CharacteristicAcceptance Criteria (Implied: Comparable to Predicate)Reported Device Performance (BT-400)Predicate Device Performance (BILI-THERAPY Spot type K103828)
    Light SourceBlue LEDsBlue LEDsBlue LEDs
    WavelengthPeak 450-475nmPeak 450-475nmPeak 450-475nm
    Intensity30-40 uW/cm² at 30cm distance30-45 uW/cm² at 30cm distance30-40 uW/cm² at 30cm distance
    Variation in intensity in 6 hrs±10% in Illumination area±10% in Illumination areaIdentical
    Effective Surface30x20cm40x20cm30x20cm
    Head output over 6 hrs<10°C warmer than ambient<10°C warmer than ambientIdentical
    Electrical Main power100-120v ac 50/60 hz 70va100-120v ac 50/60 hz 70vaIdentical
    Leakage current<100uA<100uAIdentical
    Audible Noise<60dB<60dBIdentical
    Maximum height190cm200cm190cm
    Header320x200x700mm340x210x750mm320x200x700mm
    Light assembly / Roll Stand Weight3.6kg / 8.4kg3.6kg / 8.4kgIdentical
    Operating Temp/Humidity10-30°C / 30-85%10-40°C / 30-75%10-30°C / 30-85%
    Storage Temp / Humidity0-45°C / 10-90%0-50°C / 10-100%0-45°C / 10-90%
    Atmospheric Pressure70 kPa-106 kPa70 kPa-106 kPaIdentical
    Regulatory Standard ComplianceEN6001-1, EN60601-1-2, EN60601-2-50EN6001-1, EN60601-1-2, EN60601-2-50Identical
    Intended useTreatment of Neonatal HyperbilirubinemiaTreatment of Neonatal HyperbilirubinemiaTreatment of Neonatal Hyperbilirubinema

    Note: The document explicitly states: "Note performance is similar since subject device intensity is few microwatts higher and effective area is slightly large compared to the predicate device." This indicates the device meets or exceeds the predicate's performance.


    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document refers to "Bench Tests" for performance data. These are typically laboratory tests conducted on the device itself, rather than tests on human subjects using a "test set" of patient data. Therefore, concepts like sample size for a test set, country of origin, or retrospective/prospective data are not applicable in this context. The provenance would be the test conditions within a manufacturing or testing facility.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not applicable. The device is a phototherapy unit, not an AI or diagnostic imaging device that requires expert review for ground truth establishment. The performance is assessed through physical and electrical bench testing against established standards.


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not applicable. Adjudication methods are typically used in clinical studies or studies involving human interpretation of data (e.g., medical images) where discrepancies need to be resolved. This device underwent bench testing.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable. The device is a phototherapy unit, not an AI-assisted diagnostic tool. Therefore, MRMC studies or effect sizes related to human reader improvement with AI are irrelevant to this submission.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable. The device is a physical medical device (phototherapy unit), not an algorithm or AI system.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For this device, the "ground truth" for evaluating its performance comes from established engineering and medical device standards. Specifically, the device was tested against:

    • IEC60601-1 Medical Electrical Equipment: General requirements for basic safety and essential performance.
    • IEC 60601-1-2: Electromagnetic compatibility test.
    • IEC60601-2-50 Medical Electrical Equipment part 2-50: Particular requirements for the basic safety and essential performance of Infant Phototherapy Equipment.

    The "ground truth" or reference for evaluating its properties (like wavelength, intensity, safety parameters) is defined by the requirements outlined in these standards.


    8. The sample size for the training set

    This information is not applicable. The BT-400 Neonatal Phototherapy device is a hardware medical device, not an AI/ML algorithm that requires a training set.


    9. How the ground truth for the training set was established

    This information is not applicable, as there is no training set for a hardware device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K140837

    Validate with FDA (Live)

    Device Name
    LUCID LY
    Manufacturer
    Date Cleared
    2014-09-24

    (175 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LUCID L Y, the laser system is indicated for: the incision, ablation, vaporization of soft tissues for general dermatology, dermatologic and general surgical procedures for coagulation and hemostasis.

    1064nm Wavelength: Tattoo removal: dark ink (black, blue and brown) Removal of Nevus of Ota Removal or lightening of unwanted hair with or without adjuvant preparation. Treatment of Common Nevi, Melasma Skin resurfacing procedures for the treatment of acne scars and wrinkle

    Device Description

    The LUCID LY . Nd: YAG laser system produces a one pulsed beam, 1064 nm Infrared light laser oscillation in tubes; power supplies, with non-contacted mode and consists of main function,

    laser tube : placed in the mixed crystals of copper pipe to the heater and produces a laser beam,

    Resonator : amplifies the beam, through the Xe-gas contained lamp : Xe-gas contains high pressure lamp to increase specific laser beam lamp

    This converted light energy creates the ND:YAG crystal and exhaust from the crystal is amplified into a specific wave length. Laser energy produced is delivered to the Tissue by means of an articulated arm and a specially designed multi spot Hand Piece.

    The Physician can optimize the effect for different applications by controlling the energy of the laser pulse and the spot size of the treatment beam, and is able to activate laser emission using Foot Switch.

    This system also consist of

    Optic main Bench assembly, Fiber optic Hand pieces, LCD control panel, Cooling system. Foot Pedal Switch

    AI/ML Overview

    The provided document is a 510(k) summary for the LUCID LY laser system (K140837). This document explicitly states that no clinical or non-clinical performance test data was provided in this submission (Page 4, Section 6. Performance test).

    Therefore, based on the provided document, the device (LUCID LY) does not have reported performance data or an acceptance criteria study that proves its performance in the context of clinical efficacy (e.g., tattoo removal, acne scar treatment). The submission focuses on demonstrating substantial equivalence to a predicate device (Spectra / K113588) based on technical characteristics and intended use.

    However, I can extract the general information requested, noting the absence of performance data.

    Here's the breakdown of the information based on the document:

    1. A table of acceptance criteria and the reported device performance

    • Since no clinical performance data was provided, there are no specific clinical acceptance criteria or reported device performance metrics in this document. The device is being cleared based on substantial equivalence to a predicate device, assuming similar safety and effectiveness based on technical characteristics.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not applicable. No clinical tests were performed or provided in this submission to evaluate the device's performance against specific clinical outcomes.
    • Data Provenance: Not applicable.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    • Not applicable. No clinical tests were performed or provided in this submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. No clinical tests were performed or provided in this submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This device is a laser surgical instrument, not an AI-assisted diagnostic tool involving human readers. Therefore, an MRMC study is not relevant to this device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This device is a laser surgical instrument, not an algorithm, and its performance is inherently human-in-the-loop (operated by a physician).

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Not applicable for clinical performance. The "ground truth" for this submission revolves around demonstrating that the technical specifications and intended use of LUCID LY are substantially equivalent to the predicate device (Spectra / K113588), implying similar safety and effectiveness.

    8. The sample size for the training set

    • Not applicable. No clinical data or training sets were used for an algorithm in this submission.

    9. How the ground truth for the training set was established

    • Not applicable. No clinical data or training sets were used for an algorithm in this submission.

    Summary based on the document:

    The K140837 submission for the LUCID LY laser system does not include performance criteria or a study demonstrating the device meets such criteria through clinical testing. Instead, the submission relies on demonstrating substantial equivalence to a legally marketed predicate device (K113588 Spectra) based on technical specifications (e.g., laser type, wavelength, pulse width, fluence, spot size, repetition rate) and intended uses. The document states: "Clinical and Non-Clinical performance test data was not provided in this submission. But, manufactured in accordance with both mandatory and voluntary standard." (Page 4, Section 6). The conclusion states: "LUCID LY, Nd: YAG laser system, in this submission, is substantially equivalent to several already cleared predicate device in respect to the Intended use. Main function, Technology, Principal operation and performance. And every Safety test report show it as safe and effective as predicate device and it does not raise any additional issues for safety and effectiveness." (Page 4, Section 9).

    Ask a Question

    Ask a specific question about this device

    K Number
    K123710

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-05-09

    (156 days)

    Product Code
    Regulation Number
    880.5860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Single use, Sterilized, Intended use for the subcutaneous injection of Botox®Cosmetic into parts of body below the surface of skin.

    Device Description

    UniTox® Syringe are sterile, single use, disposable hypodermic syringes with a permanently affixed lumen needle to the tip of syringe. The syringe consists of a barrel, a plunger rod with Synthetic Rubber Gasket, and yellow colored end-cap over the needle to prescrve sterility of the fluid path.
    In addition the UniTox ® Syringe are pyrogen free, and available , 0.5cc (20units), 30G X 5/16"needle length and conformed following standard (graduate drawing attached)
    ISO 7864 Sterile, Hypodermic Needles for single use
    ISO 8537: second edition,: 2007 Sterile, Single use Syringe with/without needle

    AI/ML Overview

    The provided document for KIZ3710 (UniTox® Syringe) is a 510(k) premarket notification summary. This type of submission is for medical devices that are substantially equivalent to already legally marketed devices. As such, the required testing and documentation focuses on demonstrating this equivalence rather than de novo performance studies.

    Therefore, the document does not contain the information requested regarding acceptance criteria and a study proving the device meets those criteria in the context of an Artificial Intelligence (AI) or machine learning device. The UniTox® Syringe is a physical, disposable hypodermic syringe, and its safety and effectiveness are established through comparison to predicate devices, material biocompatibility, and adherence to relevant ISO standards (e.g., for sterile hypodermic needles and syringes).

    The document specifically states:

    • "The UniTox @ Syringe are substantially equivalent in Design, Function, Performing and all used material to already cleared DMJECT Uni-body Insulin Syringe by K993017, and other several needle permanently attached Insulin Syringe, but different graduate to use Botox®Cosmetic."
    • "there are no difference in technological characteristic between the UniTox® Syringe and cited predicate device, only has different graduate (mark ) to use Botox®Cosmetic. accordingly, no any new issues of safety or effectiveness raised."
    • "UniTox® Syringe using exact same raw material, which has been previously tested and accepted Biocompatibility, and also manufactured with same process as alteady cleared Predicate Device DM JECT, SUREJECT uni-body insulin syringe K993017, so additional Biocompatibility testing to ISO10993 standard is not required."

    In summary, none of the requested information regarding AI device acceptance criteria, study data, sample sizes, expert ground truth establishment, or clinical performance studies is relevant or present in this document, as it describes a conventional medical device whose approval is based on substantial equivalence to predicate devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K121268

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-12-20

    (238 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Wandy's Dispersive Electrode is intended use to the patient during Electrosurgical procedures to provide a path for RF current to leave the patient and return to the Generator

    Device Description

    Wandy Dispersive Electrode is designed to provide a safe return path Electrosurgical current between Generator, to active electrode and to patient without cord. And able to use to any patient if full skin contact available. non sterilized and to use only one time.

    The surface of the conductive area is covered with a Bio-compatible Hydro-gel and the surface of the non-conductive area made of PE Foam and Texture Fabric is covered with Medical grade adhesive for maximum skin adhesion. This device are non sterilized and one time use only, available 3 sizes with various shape for Adult / Pediatric

    AI/ML Overview

    The Wandy Dispersive Electrode is an electrosurgical grounding pad. The provided text, a 510(k) summary, details its safety and effectiveness for FDA clearance.

    Here's an analysis of the acceptance criteria and the study information based on the provided document:

    Acceptance Criteria and Device Performance

    Acceptance CriteriaReported Device PerformanceStudy that Proves Device Meets Criteria
    Biocompatibility* Conforms to ISO 10993-1: Biological Evaluation of Medical Device.Test Report attached (mentioned in section 7. Bio-Compatibility). Details not provided in this summary.
    * In vitro Cytotoxicity: ISO 10993-5 (2002)ConformedTest Report attached (mentioned in section 7. Bio-Compatibility). Details not provided.
    * Skin Sensitization/Irritation: ISO 10993-10 (2009)ConformedTest Report attached (mentioned in section 7. Bio-Compatibility). Details not provided.
    Electrical Safety/Performance* Meets IEC 60601-2-2 (Ed 5/9, 2009-02) General requirement for safety.Bench test done by manufacturer in accordance with IEC 60601-2-2: 2006-59.104.5 / 104.79b(b).(c). Report attached (mentioned in section 6. Intended use). Details not provided.
    * Output Power: 300W, 700mA @615 ohms for less than 60 seconds.Same as predicate cleared electrode device.Bench testing (explicitly mentioned for electrical safety). Comparison to predicate. No specific study details provided beyond "Bench test done by manufacturer."
    Substantial Equivalence* Substantially equivalent to several predicate devices in respect to intended use, main function, technology, principal operation, and performance. * Does not raise any additional concerns regarding safety and effectiveness.This is an overall claim based on the technical characteristics and testing described. The 510(k) process itself establishes substantial equivalence. No specific comparative study with the predicate is detailed beyond a statement of "intended use, same output power... as predicate cleared electrode device."

    Note: The provided 510(k) summary emphasizes equivalence to a predicate device and adherence to international standards. It references "attached reports" for biocompatibility and bench testing, but the actual data and detailed methodologies of these studies are not included in the provided text.

    Study Information (Based on available text)

    1. Sample size used for the test set and the data provenance:

      • Test set sample size: Not explicitly stated for any of the tests. The document refers to "Bench test done by manufacturer" and "Test Report attached" for biocompatibility, but no specifics on sample size are provided.
      • Data provenance: The tests were conducted by the manufacturer (Wandy Rubber Industrial Co., Ltd) in Taiwan, R.O.C., as indicated by the manufacturer's address. The data is retrospective in the sense that the tests were performed to support the 510(k) submission.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This is not applicable in the context of this device and submission. The "ground truth" for a medical device like a dispersive electrode is typically established through adherence to recognized international standards (e.g., ISO for biocompatibility, IEC for electrical safety), not through expert consensus on diagnostic images or clinical outcomes. The standards themselves define acceptance criteria.
    3. Adjudication method for the test set:

      • Not applicable. The tests performed (biocompatibility, electrical safety) are objective measurements against defined criteria in international standards, not subjective assessments requiring adjudication.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done:

      • No. An MRMC study is relevant for diagnostic imaging devices where human readers interpret medical images. This is a therapeutic device (electrosurgical accessory), and such a study is not appropriate or required for its clearance.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Yes, in a way. The device's performance was evaluated in standalone bench tests according to specified standards (e.g., IEC for electrical performance, ISO for biocompatibility) without requiring human intervention in its primary function for the evaluation. These tests assess the device's inherent characteristics.
    6. The type of ground truth used:

      • Standards-based performance criteria: For electrical safety, the ground truth is defined by the parameters and limits specified in IEC 60601-2-2. For biocompatibility, it's the criteria outlined in ISO 10993-1, ISO 10993-5, and ISO 10993-10. These are objective engineering and biological safety standards.
      • Comparison to predicate device: For technological characteristics like output power, the "ground truth" for substantial equivalence is the established performance of the legally marketed predicate device (K100686 Conmed Corp Macrolyte Dispersive Electrode).
    7. The sample size for the training set:

      • Not applicable. This device does not use machine learning or AI, so there is no "training set."
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set for this device.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1