510(k) Data Aggregation

    K Number
    K221283
    Manufacturer
    Date Cleared
    2022-09-06

    (126 days)

    Product Code
    Regulation Number
    888.3040
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K172392, K211388

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HTS is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe. Cannulated implants in the HTS can be used with K-wires for the delivery of implants or the temporary stabilization of outlying joints (e.g. MTP Joint).

    Device Description

    The 4WEB HTS implants consists of a series of titanium implants that are designed to provide stability and fixation of the lesser toes in the foot. The 4WEB HTS implants have proximal and distal fixation features to provide structural support and will be offered in multiple sizes to accommodate various patients' anatomy. The implants are manufactured from Ti6Al4V alloy. Each implant is available in a sterile/packaged form.

    AI/ML Overview

    This document is a 510(k) summary for the Hammertoe Truss System (HTS). It indicates that the purpose of the submission is to update the HTS implant offering to include two smaller sizes. The document outlines the device description, indications for use, and a comparison to predicate devices, focusing on the mechanical properties and MRI compatibility.

    Here's an analysis based on your request, keeping in mind that the document mainly focuses on mechanical performance and equivalence to a predicate device, rather than a clinical study with patients or human readers.

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    Mechanical Properties:
    Finite element analysis: No new worst-case implant compared to previously cleared devices.Validated finite element analysis demonstrated that the additional implant sizes for the Hammertoe Truss System (HTS) do not create a new worst-case implant compared to the previously cleared 4WEB Hammertoe Truss System devices for mechanical properties of the device.
    ASTM F1264: Static and Dynamic 3-Point Bend and Torque to FailurePerformance completed per this standard (specific values not provided but implied to meet acceptance for substantial equivalence).
    ASTM F543: Axial Push OutPerformance completed per this standard (specific values not provided but implied to meet acceptance for substantial equivalence).
    MR Conditional Testing (based on reference predicate):
    ASTM F2119: MR Image ArtifactHammertoe Truss System does not present a new worst case compared to the reference predicate which met this standard.
    ASTM F2052: MR Induced Displacement ForceHammertoe Truss System does not present a new worst case compared to the reference predicate which met this standard.
    ASTM F2213: MR Induced TorqueHammertoe Truss System does not present a new worst case compared to the reference predicate which met this standard.
    ASTM F2182: MR Induced HeatingHammertoe Truss System does not present a new worst case compared to the reference predicate which met this standard.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This submission describes engineering performance testing and simulation analysis, not a clinical study on a test set of patient data. Therefore, the concepts of "sample size for the test set" and "data provenance" in a clinical context are not applicable. The testing was done on physical device prototypes or through computer-simulated models.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the submission reports on mechanical and MRI compatibility testing of a physical device, not a diagnostic or AI-driven system requiring expert review of medical images.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable. Adjudication methods are relevant for studies involving human interpretation of data, typically in clinical trials or diagnostic accuracy studies.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, a multi-reader, multi-case (MRMC) comparative effectiveness study was not done. This submission focuses on the safety and effectiveness of a physical implantable device based on mechanical and MRI compatibility testing, demonstrating substantial equivalence to a predicate device. It does not involve AI or human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    No, a standalone algorithm performance study was not done. This submission is for a physical medical device (implant).

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" for this type of submission is based on engineering standards and established test methods (e.g., ASTM standards) for evaluating the mechanical properties and MRI compatibility of medical implants. The "truth" is whether the device physically performs in accordance with these validated standards and demonstrates similar characteristics to the predicate device.

    8. The sample size for the training set

    This is not applicable. The device is a physical implant, not an AI or machine learning model that requires a training set. The "training" for such devices involves design, manufacturing, and extensive bench testing.

    9. How the ground truth for the training set was established

    This is not applicable for the reasons mentioned in point 8.