510(k) Data Aggregation

    K Number
    K222760
    Manufacturer
    Date Cleared
    2022-12-28

    (106 days)

    Product Code
    Regulation Number
    888.3027
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K080979

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    StageOne™ Select Hip Cement Spacer Molds with stainless steel reinforcement stems, adapters and inserts are indicated for use to mold a temporary hemi-hip replacement for skeletally mature patients undergoing a two-stage revision procedure due to a septic process. The temporary prosthesis is molded using Refobacin Bone Cement R, assembled and inserted into the femoral medullary cavity following removal of the existing femoral and acetabular replacement implants and debridement. The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy (standard treatment approach to an infection).

    The hemi-hip prosthesis made from the StageOne™ Select Cement Spacer Molds is not intended for use more than 180 days, at which time it must be explanted and permanent devices implanted or another appropriate treatment performed (e.g. resection arthroplasty, fusion, etc.).

    Due to the inherent mechanical limitations of the hemi-hip prosthesis material (Refobacin Bone Cement R), the temporary hemi-hip prosthesis is only indicated for patients who will consistently use traditional mobility assist devices (e.g. crutches, walkers) throughout the implant period.

    Device Description

    The StageOne™ Select Hip Cement Spacer Molds are sterile, single use medical devices made of silicone with a stainless steel reinforcement stem, head insert and neck length adapter. The device is used to create a temporary hip implant component made from antibiotic bone cement, Refobacin® Bone Cement R by injecting with a dispenser/gun into the mold. After removal of the initial femoral and acetabular implants, the prepared cement spacers are assembled using the neck length adapter and placed into the femoral joint space using Refobacin® Bone Cement R as the first stage of a two-stage revision surgical procedure. The temporary hemi-hip prosthesis remains in place (180 days or less) until the second stage of the two-stage revision procedure is performed to implant a conventional hip joint prosthesis.

    AI/ML Overview

    The provided text is related to an FDA 510(k) premarket notification for a medical device called "StageOne™ Select Hip Cement Spacer Molds." It details the device's purpose, indications for use, and a comparison to predicate and reference devices to establish substantial equivalence.

    However, the document DOES NOT contain information about acceptance criteria or a study that proves the device meets specific performance metrics in the context of an AI/ML medical device submission. This document pertains to a physical medical device (cement molds) and the testing described is non-clinical (biocompatibility, packaging, shelf-life, sterilization, MRI analysis, fatigue performance, antibiotic elution, BET, and pyrogenicity testing) and does not involve AI/ML performance evaluation.

    Therefore, I cannot fulfill the request to describe acceptance criteria and a study proving device performance in the context of AI/ML, as the provided text does not contain such information.