Search Results
Found 2 results
510(k) Data Aggregation
(129 days)
The Ventix Suture Anchors are indicated for use in soft tissue reattachment procedures in the shoulder, wrist/hand, ankle/foot, elbow, knee, and hip. Specific indications are:
Shoulder: Bankart repair, SLAP lesion repair, acromio- clavicular separation, rotator cuff repair, capsule repair or capsulolabral reconstruction, biceps tenodesis, deltoid repair, pectoralis major repair.
Wrist/Hand: Scapholunate ligament reconstruction, ulnar/radial collateral ligament reconstruction.
Ankle/Foot: Lateral stabilization, medial stabilization, Achilles tendon repair/reconstruction, hallux valgus reconstruction, mid- and forefoot reconstruction.
Elbow: Ulnar or radial collateral ligament reconstruction, biceps tendon reconstruction, Lateral epicondylitis repair
Knee: Medial collateral ligament repair, lateral ligament repair, posterior oblique ligament repair, joint capsule closure, iliotibial band tenodesis, and patellar ligament/tendon repair, medial patellofemoral ligament (MPFL) repair or reconstruction, quadriceps tendon repair.
Hip: Proximal hamstring repair
The Ventix Suture Anchor is a two-piece design consisting of the vented body and the threaded tip preloaded with suture. The anchor will be offered in three sizes: 3.5mm, 4.75mm, and 5.5mm and is manufactured from polyetheretherketone (PEEK). The Ventix Suture Anchor will be loaded onto a disposable inserter and will be available with #2 MaxBraid or 1.5mm ForceFiber OrthoTape suture.
The provided document is a 510(k) premarket notification for the Ventix Suture Anchor. It primarily focuses on demonstrating substantial equivalence to legally marketed predicate devices, rather than establishing acceptance criteria and detailed study results for the device's performance against specific metrics.
Therefore, much of the requested information about acceptance criteria, detailed study results, sample sizes for test and training sets, ground truth establishment, expert qualifications, adjudication methods, and MRMC studies cannot be extracted from this document.
However, I can provide the limited information available regarding performance testing:
1. A table of acceptance criteria and the reported device performance
Acceptance Criteria | Reported Device Performance |
---|---|
Pull-out strength: Statistically equivalent or greater fixation strength compared to predicate devices. | The Ventix Suture Anchors provide statistically equivalent or greater fixation strength to the predicate devices. |
2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
This information is not provided in the document. The document only mentions that non-clinical laboratory testing was performed using the Ventix Suture Anchors and predicate devices for comparison.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This information is not applicable as the document describes non-clinical mechanical testing, not a study involving expert assessment of medical images or patient outcomes.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
This information is not applicable as the document describes non-clinical mechanical testing, not a study involving human readers or subjective assessments.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
There was no MRMC comparative effectiveness study done. The document explicitly states "Clinical Tests - None provided as a basis for substantial equivalence." The testing described is non-clinical mechanical testing.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This information is not applicable. The device is a physical suture anchor, not an algorithm or AI system. The testing described is mechanical performance.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
For the non-clinical pull-out strength testing, the "ground truth" would be the measured mechanical pull-out strength values obtained directly from the testing equipment. This is objective data.
8. The sample size for the training set
This information is not applicable. The device is a physical product, not an AI or machine learning algorithm that requires a training set.
9. How the ground truth for the training set was established
This information is not applicable as there is no training set for a physical device.
Ask a specific question about this device
(112 days)
The RoG 5.5 mm Suture Anchor is indicated for soft tissue reattachment procedures in the shoulder, elbow, wrist/hand, foot/ankle and knee. Specific indications are as follows:
- . Shoulder indications:- Bankart repair, rotator cuff repair, SLAP lesion repair, capsule repair or capsulolabral reconstruction, acromio-clavicular separation, deltoid repair, biceps tenodesis.
- Wrist/hand indications:- Ulnar/Radial collateral ligament reconstruction, scapholunate ligament reconstruction.
- Foot/Ankle indications: Achilles tendon repair/reconstruction, hallax valgus reconstruction, lateral stabilization, medial stabilization, mid- and forefoot reconstructions.
- t Elbow indications:- Biceps tendon reconstruction, ulnar or radial collateral ligament reconstruction, lateral epicondylitis repair.
- Knee indications:- Lateral collateral ligament repair, medial collateral ligament repair, posterior oblique ligament repair, patellar ligament/tendon repair, iliotibial band tenodesis, joint capsule closure.
The RoG 2.9mm Suture Anchor is indicated for use in soft tissue reattachment procedures. Specific indications are as follows:
- Shoulder indications:- Bankart repair, rotator cuff repair, SLAP lesion repair, capsule repair or capsulolabral reconstruction, acromio-clavicular separation, deltoid repair, biceps tenodesis.
- Wrist/hand indications:- Scapholunate ligament reconstruction. .
- . Elbow indications:- Biceps tendon reconstruction, ulnar or radial collateral ligament reconstruction.
- Knee indications:- Lateral collateral ligament repair, medial collateral ligament repair, posterior oblique ligament repair, patellar ligament/tendon repair. iliotibial band tenodesis, joint capsule closure. extracapsular repair, vastus medialis obliquus (VMO) muscle advancement.
The subject device is screw-like in shape and composed exclusively of PEEK plastic. It is available in diameters of 5.5mm and 2.9mm and lengths of 10mm and 17mm. It is supplied non-sterile and is intended for sterilization by the user facility. It allows the user to secure a suture of his/her selection to the top of the anchor. The anchor is supplied with reusable taps and guides of corresponding sizes.
The provided document is a 510(k) summary for the RoG Suture Anchor, a medical device. It describes the device's technical specifications, intended use, and its equivalence to predicate devices, but it does not contain information about a study involving AI, human readers, or image analysis.
The 510(k) process is for demonstrating substantial equivalence to a legally marketed predicate device, primarily focusing on design considerations, materials, performance characteristics (mechanical testing), and indications for use. It typically does not involve the kind of clinical or comparative effectiveness studies with human readers or AI that your request outlines.
Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving a device meets these criteria in the context of AI performance, human readers, or ground truth establishment in the way you described, because the provided document does not pertain to such a device or study.
The "Performance Characteristics" section explicitly states: "Both sizes of subject were evaluated in accordance with FDA's Guidance Document for Testing Bone Anchor Devices (4/20/96). Testing consisted of tapping and pull testing with comparison to the corresponding size of predicate devices. The subject device was found to be equivalent to the corresponding sizes of the predicate devices in such testing." This indicates the evaluation was purely mechanical and comparative to existing similar devices.
Ask a specific question about this device
Page 1 of 1