K Number
K243232Device Name
GripMate
Manufacturer
Synthon Hispania S.L.
Date Cleared
2024-12-02
(54 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The GripMate™ autoinjector is intended for use with Sun Pharma's glatiramer acetate 20 mg/mL and 40 mg/mL prefilled syringes (a 1 mL BD Hypak Biotech glass syringe, containing a ½'' fixed needle of 29G, and drug product solutions with a viscosity between 1.7 and 2.3 mPas). The GripMate™ autoinjector is a reusable injection device for patients with multiple sclerosis age 18 and older for the subcutaneous injection of Sun Pharma's glatiramer acetate 20 mg/mL and 40 mg/mL prefilled syringes.
Device Description
The GripMate™ is a non-sterile, reusable, spring-loaded injection device. The device consists of two subassemblies into which the syringe is loaded and connected together to form the delivery system for self-injection. The device does not have any fluid path and does not have any contained within the syringe. The user has the option to adjust the needle extension using the device Needle Hider Feature. Injection occurs upon the activation of a trigger button which drives the syringe in a three-step sequence which includes needle penetration, injection and needle cover. Once the injection is completed the device provides visual indication to confirm that the full drug dose has been delivered.
Ask a Question
K Number
K213429Device Name
AccuSert Needle Inserter
Manufacturer
Emed Technologies Corporation
Date Cleared
2022-10-20
(364 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
AccuSert Needle Inserter is intended for use at home or hospital environment to assist inserting EMED subcutaneous administration needle sets into the subcutaneous tissue at 90 degrees. Single patient use only.
Device Description
The EMED AccuSert Needle Inserter is a manually operated, reusable, spring-loaded injection device. This device is used to insert EMED subcutaneous infusion administration sets. The device is contraindicated for use with other sets. The AccuSert Needle Inserter consists of a plastic body containing a stainless-steel spring and a needle carrier component.
Ask a Question
K Number
K163400Device Name
Orbit Inserter
Manufacturer
YPSOMED AG
Date Cleared
2017-07-26
(233 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Orbit Inserter is indicated to aid the user with the insertion of the cannula into the subcutaneous tissue for compatible infusion sets listed on the labeling.
The Orbit Inserter is intended to be used to assist patients and their caregivers by providing a mechanism to automate the insertion of compatible Ypsomed Infusion Sets primarily in a home setting.
Device Description
The Orbit Inserter is a manually operated, spring-loaded insertion aid for automatic insertion of compatible Orbit infusion sets. It assists the user with insertion of the infusion set cannula into the subcutaneous tissue. The device is non-invasive, non-sterile and intended for multiple uses by the same patient. The Orbit Inserter is made of plastic and is powered by a stainless-steel spring.
Ask a Question
K Number
K160860Device Name
MiniMed Quick-serter
Manufacturer
MEDTRONIC MINIMED
Date Cleared
2016-09-22
(177 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The MiniMed Quick-serter is indicated to use as an aid for inserting compatible devices. It is for use by a single patient. It is not for use by multiple patients.
Device Description
The modified MiniMed Quick-serter (MMT-305) is a non-sterile, single patient, multi-use, hand held accessory product designed to be used as an insertion aid for compatible devices, including specific infusion sets. It is used to insert the introducer needle and cannula through the skin and into the subcutaneous tissue. The MiniMed Quick-serter is intended to be used by a patient or clinician as a means to insert an infusion set with minimum discomfort and technique dependency.
The MiniMed Quick-serter consists of a plastic barrel containing a stainless steel spring and a handle. The device user places and securely seats the infusion set into the MiniMed Quick-serter is loaded and locked by pulling the handle (compressing the spring) until it clicks/locks into place. The serter is placed in contact with the insertion site and fired to release the infusion set. This is done by depressing the green side buttons to release the spring, which drives the infusion set forward and the insertion needle and cannula are inserted into the user's subcutaneous tissue. The release button on the top of the device is then pressed to ease the release of the infusion set from the serter.
Ask a Question
K Number
K141384Device Name
WHISPERJECT AUTOINJECTOR
Manufacturer
SCANDINAVIAN HEALTH LIMITED
Date Cleared
2014-09-12
(108 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Whisper JECT autoinjector is a non-sterile injection device. It is intended to be used with FDA approved drug products with non-viscous (aqueous) liquid formulations, which are presented in a BD 1.0 mL pre-filled glass syringe with staked needles. It is a reusable injection device for the subcutaneous injection of FDA approved drugs.
Device Description
The WhisperJECT™ autoinjector is a reusable, spring-loaded injection device that is for general use with 1.0 ml pre-filled glass syringes. WhisperJECTTM autoinjector consists of two subassemblies into which the syringe is loaded and connected together to form the delivery system for self-injection.
Ask a Question
K Number
K124026Device Name
LOBSTER AUTO-INJECTOR
Manufacturer
SCANDINAVIAN HEALTH LIMITED
Date Cleared
2013-09-13
(259 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Lobster device is intended for use with a ImL glass syringe, containing a fixed needle of 27G to 29G gauge, and drug product solutions with a viscosity between 1 and 4 mPa*s. The Lobster auto-injector is a reusable injection device for the subcutaneous injection of FDA approved drugs.
For single patient or individual use only.
Device Description
The Lobster Auto-injector is a reusable, spring-loaded injection device that is for use with 1.0 ml pre-filled glass syringes with staked needle. Lobster Auto-injector consists of two subassemblies into which the syringe is loaded and connected together to form the delivery system for self-injection.
Ask a Question
K Number
K122837Device Name
AUTOJECT 2 FOR GLASSY SYRINGE
Manufacturer
OWEN MUMFORD, LTD.
Date Cleared
2012-10-15
(28 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Autoject® II for glass syringe is a non-sterile fully automatic injection device. The device is intended for the self-administration of an FDA approved drug. The device is designed for use with 1ml fixed needle pre-filled glass syringe, for use in the home to aid, support and reduce patient liked needle phobia. It has been developed to provide a safe and simple procedure to the patient.
Device Description
The 'Autoject® II for glass syringe' is composed of simple plastic injection moulded parts and stainless steel springs. The device is a non-sterile, handheld mechanical device intended for self-administered, subcutaneous delivery of an FDA approved drug. The device is designed for use with 1ml fixed needle pre-filled glass syringe, for use in the home to aid, support and reduce patient liked needle phobia. It has been developed to provide a safe and simple procedure to the patient.
Ask a Question
K Number
K111467Device Name
FLEXI-Q DV AND DVR AUTO-INJECTORS
Manufacturer
ELCAM MEDICAL A.C.A.L.
Date Cleared
2012-02-09
(259 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Flexi-Q DV Auto-injector is indicated for the transfer and automated subcutaneous injection of FDA approved drugs and biologics in compatible vials.
The Flexi-Q DV Auto-injector is intended for use in the home environment by the patient or care-giver after training by a Health Care Professional.
Device Description
The Flexi-Q DV Auto-injector (also called: FUDAI DV)) is designed to allow people with or without minor dexterity problems (or with a help of a care giver) to aspirate a drug in solution form from a standard 13mm vial and automatically inject themselves subcutaneously with the drug.
The device is comprised of the following parts;
- -Housing: The outer shell/covering of the device. The Housing which encloses and protects the inner components including the syringe, is designed to be used while held with one hand and provides the user with visibility of the solution/ drug before, during and after injection via a window.
- -Syringe: A standard 1mL long glass syringe is assembled within the Housing. The syringe includes a staked 1/2 27G needle and an elastomeric syringe piston. The syringe is marked with a single graduation line indicating the dose volume to be aspirated and delivered (any dosage between 0.3 to 1.0mL is possible; e.g., 0.3 or 0.4 or 0.5 or 0.6 etc. up to 1.0mL). i.e., different Flexi-Q Auto-injector versions will be available, each for a single dosage volume, and according to physician prescription, the patient will use the Flexi-Q Auto-injector version specifically marked for his/her prescribed dose volume. The "single dose - single device" Flexi-Q auto-injectors are illustrated in page 11-13, Figure I. The syringe needle is used to penetrate the Vial Adaptor septum (for solution/reconstituted drug aspiration) and then to administer the subcutaneous injection to the patient.
- -Needle Shield: The needle shield covers the needle before injection. When depressed against the skin, the shield "unlocks" the Trigger Button to allow activation and injection. After the injection is completed, the shield locks in place, keeping the needle from being accessible and helping protect the user from accidental needle stick injury.
- Plunger Rod: A rigid rod that is connected to the syringe piston and protrudes out of the Auto-injector's Housing. The Plunger Rod is used to aspirate the solution/reconstituted drug into the syringe and adjust the volume to be injected to the predefined dosage.
- Trigger Button (Red INJECT Button): This button enables the user to activate the injection process after is has been unlocked by the user pressing the shield against the skin at the injection site. Once pressed the device advances the injection needle into the subcutaneous tissue followed by injection of the drug.
- One Vial Adaptor (Gray Connector): The Sterile, Single use Vial Adaptor . functions as a connector between the Auto-injector and the drug vial and provides a fluid path to enable aspiration of the drug. The syringe needle penetrates a septum (assembled inside the Vial Adaptor) made of thermoplastic elastomer while a plastic spike (part of the Vial Adaptor) penetrates the vial stopper. While attached to the Auto-injector, the Vial Adaptor conceals the Needle Shield and thus preventing inadvertent activation.
In certain cases when additional vial may be used (per drug prescription), additional sterile vial adaptor(s), may be used.
Ask a Question
K Number
K082587Device Name
AUTO-SAFETY INJECTOR-2 (ASI-2)
Manufacturer
MEDICAL HOUSE PRODUCTS LIMITED
Date Cleared
2008-10-02
(24 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Auto Safety Injector 2 (ASI-2) is indicated for assisting the self-administered subcutaneous injection of fixed doses of FDA-approved drug products with non-viscous (aqueous) liquid formulations, which are presented in standard 1 ml long BD Hypak® pre-filled syringes with staked needles.
The ASI-2 is primarily intended for home use by patients to aid and support their treatment regime or may be used by Health Care Professionals or caregivers.
Device Description
The ASI-2 is a single-use, automatic, disposable and hidden-needle auto-injector for the self-administration of liquid drug products.
Ask a Question
K Number
K073476Device Name
COMPACT AUTO-SAFETY INJECTOR (CASI)
Manufacturer
MEDICAL HOUSE (ASI) LIMITED
Date Cleared
2008-03-07
(88 days)
Product Code
KZH
Regulation Number
880.6920Why did this record match?
Product Code :
KZH
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Compact Auto Safety Injector (CASI) is indicated for assisting the selfadministered subcutaneous injection of fixed doses of FDA approved drug products with viscous liquid formulations, which are presented in standard 1ml long BD Hypak® pre-filled syringes with staked needles. The CASI is primarily intended for home use by patients to aid and support their treatment regime or may be used by Health Care Professionals or caregivers.
Device Description
The CASI is a single-use, automatic, disposable and hidden-needle auto-injector for the self-administration of liquid drug products.
Ask a Question