510(k) Data Aggregation

    K Number
    K111391
    Date Cleared
    2012-09-26

    (497 days)

    Product Code
    Regulation Number
    880.2800
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    STERRAD (R) 100NX DUO CYCLE TEST PACK

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The STERRAD® 100NX® DUO Cycle Test Pack is used for routine monitoring of the STERRAD® 100NX® DUO Sterilization Cycle and is also used for the periodic testing of a STERRAD® 100NX® System DUO Cycle, using hospital-defined loads containing devices that do not exceed claims of the cycle. The STERRAD® 100NX® DUO Cycle Test Pack consists of a STERRAD® CYCLESURE® 24 Biological Indicator, vial and cap to hold the BI.

    Device Description

    The STERRAD® 100NX® DUO Test Pack consists of a CYCLESURE® 24 Biological Indicator (BI) and a STERRAD® NX® Test Vial with cap for holding the BI during the sterilization cycle.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and the study that proves the device meets those criteria:

    Acceptance Criteria and Device Performance

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Resistive Equivalence to Biological Model: The Test Pack must be at least as resistant to the sterilization process as the biological model developed for the DUO Cycle.Passed. Based on both survival curves and fraction negative data as a function of dose, the Test Pack configuration was found to be at least as resistant as the biological model.
    Functionality of Chemical Indicator Disc: The chemical indicator in a DUO Test Pack configuration must show appropriate response in half-cycle parameters of the DUO Cycle.Passed. The response was determined to be appropriate for a chemical indicator.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: "DUO Test Packs assembled from three lots of CYCLESURE® 24 Biological Indicator (BI)" were used for the resistance evaluation.
    • Data Provenance: Not explicitly stated, but given that the applicant is Advanced Sterilization Products, a division of Ethicon, Inc. located in Irvine, CA, it is highly likely the testing was conducted prospectively and in the United States. The study description implies a laboratory or controlled setting.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    There is no mention of human experts being used to establish the "ground truth" for this device. The ground truth is intrinsically defined by the biological model and the chemical indicator's expected behavior within the sterilization process. The "ground truth" here is the scientific measurement of biological indicator survival and chemical indicator color change.

    4. Adjudication Method for the Test Set

    Not applicable. There was no human adjudication as the assessment was based on objective biological and chemical responses.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is typically used for diagnostic or imaging devices where human interpretation is a key component, and the AI's impact on human performance is being measured. This device is a biological indicator for sterilization monitoring, not a diagnostic tool requiring human interpretation for its primary function.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, in essence. The entire evaluation focuses on the performance of the STERRAD® 100NX® DUO Cycle Test Pack product itself, which functions as a standalone indicator of sterilization effectiveness. Its performance is measured directly against established biological models and chemical indicator specifications, without human interaction influencing the core function it is designed to evaluate (i.e., whether sterilization occurred). The "algorithm" here isn't a complex AI, but rather the intrinsic biological and chemical response mechanisms of the test pack.

    7. The Type of Ground Truth Used

    The ground truth used is based on:

    • Biological Model: The established and validated "biological model developed for the DUO Cycle" represents the benchmark for resistance to the sterilization process. This model likely involves characterized microorganisms and their known inactivation kinetics.
    • Expected Chemical Indicator Response: The predetermined, appropriate response of the chemical indicator to the sterilization conditions (specifically half-cycle parameters).

    8. The Sample Size for the Training Set

    There is no explicit mention of a "training set" in the context of an AI/ML algorithm. This device is not an AI/ML product. The testing involves physical devices (biological indicators) rather than training data for an algorithm. The "training" in this context would be the historical data and scientific principles used to develop the biological model itself, but that's not described here.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no explicitly defined "training set" for an AI/ML algorithm. The "ground truth" for the device's functional evaluation (as described in point 7) is established through scientific validation of the biological model and the chemical indicator's properties, likely using established standards and lab procedures.