510(k) Data Aggregation

    K Number
    K020733
    Device Name
    PVS 1500 SDS
    Date Cleared
    2002-03-21

    (15 days)

    Product Code
    Regulation Number
    870.1210
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    PVS 1500 SDS

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PVS 1500 SDS is intended to be used to access tortuous vasculature for infusion of diagnostic, embolic, and therapeutic agents into the distal, peripheral, coronary, and neurovasculature, and for guide wire exchange/support during diagnostic Or interventional procedures.

    The PVS 1500 SDS is intended for use in accessing distal peripheral, coronary, and neurovasculature for selective, controlled, regional delivery of diagnostic, embolic, and therapeutic agents into selected vessels.

    Device Description

    The PVS 1500 SDS is a 2.4 F tubular device, 155 cm in length, with a lumen to be used for delivery of contrast, drugs, or embolics. The lumen is constructed from a polyment material and has an inside diameter of 0.021". The device is coated on the outer diameter with a lubricious coating over the distal segment of the device. Two radiopaque markers are positioned 31 mm apart at the distal tip of the device to aid visualization under fluoroscopy. The proximal end of the device has a standard luer adapter for attachment of accessories and can be used to flush the 1500 SDS. The subject device has the ability to access distal, tortuous vasculature over a guide wire, deliver embolics and agents, and has the ability to be steered like a guide wire as needed.

    AI/ML Overview

    The provided text describes a medical device, the PVS 1500 SDS (an infusion catheter), and its testing to demonstrate substantial equivalence to predicate devices, rather than a study evaluating an AI/ML powered device. Therefore, many of the requested categories for AI/ML device studies are not applicable.

    Here's an analysis based on the provided text:

    Acceptance Criteria and Device Performance for PVS 1500 SDS

    The study primarily focused on demonstrating the PVS 1500 SDS's substantial equivalence to existing predicate devices by meeting established performance standards for infusion catheters.

    Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Tests PerformedReported Device Performance
    BiocompatibilityISO 10993-1, Biological Evaluation of Medical Devices - Part 1Confirmed biocompatibility as an external communicating, blood contact, short duration (