510(k) Data Aggregation

    K Number
    K000670
    Date Cleared
    2000-04-12

    (44 days)

    Product Code
    Regulation Number
    880.6250
    Reference & Predicate Devices
    N/A
    Why did this record match?
    Device Name :

    NITRILE EXAM GLOVE, POWDER FREE, BLUE

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K980802
    Date Cleared
    1998-03-25

    (23 days)

    Product Code
    Regulation Number
    880.6250
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    NITRILE EXAM GLOVE, POWDER-FREE, BLUE

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

    Device Description

    Nitrile Exam Gloves, Powder-Free, Blue

    AI/ML Overview

    This document is a 510(k) summary for a Nitrile Exam Glove, Powder-Free, Blue. It is a medical device submission, and the content provided does not relate to an AI/ML powered device or a study demonstrating its performance. Therefore, I cannot fulfill your request for detailed information about acceptance criteria, study design, and AI-specific metrics like MRMC studies or human reader improvement, as these concepts are not applicable to the provided document.

    The document discusses the substantial equivalence of the Nitrile Exam Glove to already marketed devices based on physical characteristics and intended use. The "Test Results" section (K980802 on page 34 of 34) lists the standards and tests that the device has met or exceeded, which serve as the acceptance criteria for the glove's performance.

    Here's a breakdown of the information that can be extracted relevant to your request, adapted for a non-AI medical device submission:

    1. Table of Acceptance Criteria and the Reported Device Performance:

    Acceptance Criteria (Standards/Tests Met)Reported Device Performance
    ASTM D 3578-95Met or exceeded
    ASTM D 5151Met or exceeded
    FDA Water Leak Test (before & after aging)Met or exceeded
    Nitrile Glove Draft ASTM, Sept 97Met or exceeded
    Bio-Compatibility Dermal SensitizationMet or exceeded
    Primary Skin IrritationMet or exceeded
    Bio-Burden (bacteria/mold)Met or exceeded

    2. Sample size used for the test set and the data provenance:

    • Sample Size: The document does not specify the exact sample sizes used for each test. For medical devices like gloves, testing is typically done on representative batches according to the specified ASTM standards.
    • Data Provenance: Not explicitly stated, but assumed to be from laboratory testing conducted on the manufacturer's product (Sinochem Ningbo Latex Gloves Factory). The document does not specify country of origin for the data itself, but the device is manufactured by Sinochem Ningbo Latex Gloves Factory, implying the testing was done on their product. It is a retrospective evaluation of the product's compliance with established standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This concept is not directly applicable to the testing of examination gloves. The "ground truth" here is adherence to objective, standardized test methodology and performance thresholds defined by organizations like ASTM and the FDA. The experts involved would be the certified laboratory technicians and engineers performing these specific tests, adhering to the standard protocols. Their qualifications would be in laboratory practices and materials testing, not medical diagnosis or interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable. Performance testing for medical gloves involves objective measurements against predefined standards, not subjective interpretations requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an AI/ML device.

    7. The type of ground truth used:

    • The "ground truth" is defined by the objective performance criteria specified in the referenced ASTM standards and FDA guidelines (e.g., specific tensile strength, elongation, water leak rate, biocompatibility thresholds).

    8. The sample size for the training set:

    • Not applicable. This is not an AI/ML device. There is no concept of a "training set" in the context of standard physical and biocompatibility testing for medical gloves.

    9. How the ground truth for the training set was established:

    • Not applicable.