Found 2 results

510(k) Data Aggregation

    K Number
    K132570
    Manufacturer
    Date Cleared
    2014-04-29

    (257 days)

    Product Code
    Regulation Number
    872.4200
    Panel
    Dental
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    ELECTRIC HANDPIECE SYSTEM

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Thor 700 Electric Handpiece System is intended to convert pneumatic output from a dental treatment center to electrical energy for operation of electrically-driven dental handpiece.

    Device Description

    Thor 700 Electric Handpiece System is composed of a system unit, which is connected to a : power supply and a control tube, that system unit drives a dental drive device. The system unit converts pneumatic output from the dental treatment unit to control the torque, speed and directional rotation of the dental drive device. The dental drive device, in turn, provides the control for motorized dental handpieces. The inputs to the system unit are supplied by a dental treatment unit. Inputs can also be controlled by the foot pedal of the treatment unit.

    AI/ML Overview

    This submission package for the Thor 700 Electric Handpiece System primarily focuses on demonstrating substantial equivalence to a predicate device (Siro Torque L, K031584) through a comparison of technical specifications and non-clinical performance testing. It does not describe an AI/ML-based device, therefore, many of the requested details concerning acceptance criteria and studies for AI performance metrics are not applicable.

    Here's an analysis based on the provided document:

    Acceptance Criteria and Reported Device Performance (Table)

    The document evaluates the Thor 700's performance against established standards and safety requirements, rather than against specific clinically relevant accuracy metrics typically associated with AI/ML devices. The "acceptance criteria" here are generally compliance with international standards and direct comparison of specifications to the predicate device.

    Acceptance Criteria / Performance MetricTarget (Predicate/Standard)Thor 700 Reported PerformanceStudy/Test Conducted
    Electrical SafetyIEC 60601-1CompliesIEC 60601-1 testing
    Electromagnetic Compatibility (EMC)IEC 60601-1-2CompliesIEC 60601-1-2 testing
    Software ValidationFDA Guidance "General principle of Software Validation; Final Guidance for Industry and FDA staff", Jan 11, 2002Successfully validatedSoftware validation
    Performance (Noise)ISO 11498CompliesISO 11498 performance testing
    Sterilization Validation (132°C for 15 min, drying 30 min)ANSI/AAMI ST79:2010CompliesSterilization validation (132°C/15min, 30min drying)
    Biocompatibility (Erythema & Oedema)ISO 10993-10 (Response "negligible")No erythema, no oedema; "negligible" responseISO 10993-10 testing on rabbits
    Intended Use EquivalenceMatches Predicate (Siro Torque L)Substantially equivalentComparison of intended uses
    Components EquivalenceComparable to PredicateSystem unit, power supply, control tube, dental drive deviceComparison of components
    Principle of Operation EquivalenceComparable to PredicateSimilar power, cooling, and foot pedal controlComparison of operating principles
    Material Composition EquivalenceIdentical to PredicateAluminum, Stainless Steel, PlasticComparison of materials
    Patient ContactNone (Matches Predicate)No contact with patientsTechnical comparison
    System Unit PresenceYes (Matches Predicate)YesTechnical comparison
    Speed ControlYes (Matches Predicate)YesTechnical comparison
    Digital Speed ReadoutYes (Matches Predicate)YesTechnical comparison
    Installation CapabilityPredicate: internal/externalThor 700: externalTechnical comparison
    Individually Programmable Settings2 (Matches Predicate)2Technical comparison
    Forward/Reverse SwitchesYes (Matches Predicate)YesTechnical comparison
    Spray Water PressurePredicate: 29 psi (2.0 bar)Thor 700: 36 psi (2.5 bar)Technical comparison
    Spray Air PressurePredicate: 39 psi (2.7 bar)Thor 700: 29 psi (2.0 bar)Technical comparison
    Voltage InputAC: 100-240V, 50/60 Hz (Matches Predicate)AC: 100-240V, 50/60 HzTechnical comparison
    Voltage OutputPredicate: DC: 24V DCThor 700: DC: 48V DCTechnical comparison
    Motor Speed2000-40000 rpm (Matches Predicate)2000-40000 rpmTechnical comparison
    Motor DiameterPredicate: 21 mmThor 700: 22 mmTechnical comparison
    TorquePredicate: 2.4 N-cm maximumThor 700: 3 N-cm maximumTechnical comparison
    WeightPredicate: 100 gramsThor 700: 62 gramsTechnical comparison
    Cooling Air Pressure30 NL/min (Matches Predicate)30 NL/minTechnical comparison
    Coupling DimensionsAccording to ISO-3964 (Matches Predicate)According to ISO-3964Technical comparison
    Hose ConnectionsAccording to ISO-9168 (Matches Predicate)According to ISO-9168Technical comparison

    Details for AI-Specific Questions (Not Applicable for this Device)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not Applicable. This is a hardware device (electric handpiece system) and does not involve an AI/ML component or a "test set" of data in the context of diagnostic or predictive performance. The testing involved
      • Electrical safety and EMC testing (IEC standards).
      • Software validation (internal process, not a clinical data set).
      • Performance testing (ISO 11498 for noise, likely empirical measurements of mechanical properties).
      • Sterilization validation (empirical testing in a lab).
      • Biocompatibility testing (animal studies - rabbits).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not Applicable. No ground truth in the context of AI/ML classification or prediction was established. "Ground truth" for this device relates to compliance with engineering standards and physiological safety, typically assessed by qualified engineers and toxicologists/biocompatibility experts with appropriate certifications, not medical specialists for diagnostic accuracy.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable. No test set requiring expert adjudication for ground truth was used.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This device is an electric handpiece system, not an AI-assisted diagnostic or therapeutic tool for human readers. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Not Applicable. This is not an algorithm-only device. Software validation was performed, but it pertains to the control and operation of the hardware, not an AI for interpretation or diagnosis.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    • Not Applicable in the AI/ML sense. The "ground truth" for this device's performance is defined by compliance with established international standards (IEC, ISO, ANSI/AAMI) for electrical safety, EMC, mechanical performance (e.g., speed, torque, noise), software functionality, and biocompatibility. The predicate device's specifications also serve as a comparative benchmark.

    8. The sample size for the training set

    • Not Applicable. This device does not use an AI/ML model that requires a training set of data.

    9. How the ground truth for the training set was established

    • Not Applicable. No training set was used.
    Ask a Question

    Ask a specific question about this device

    K Number
    K031540
    Date Cleared
    2003-06-30

    (45 days)

    Product Code
    Regulation Number
    872.4200
    Panel
    Dental
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    APEX ELECTRIC HANDPIECE SYSTEM

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Lares Research Apex™ Electric Handpiece System ("System" defined as and limited to: A. Contra Angle Dental Instrument B. Electric Motor and C. Control System) device consists of a dental handpiece and accessories as listed in 21 CFR 872.4200, product code EKX that is a Class I, non-exempt hand-held device for dental drilling applications. This device is indicated for use where high speeds are required in general dentistry with or without the use of coolant where precision control of the cutting bur is desired such as cutting a tooth for caries, and/or crown preparation and finishing, cutting and/or finishing for dentures, denture bases, crowns, inlays and metal plates and/or root canal preparation for restoration. The device is also indicated for use in difficult to reach areas in general dentistry with or without the use of coolant where precision control of the cutting bur is desired such as the preparing dental caries for restorations, and for use at low speeds in teeth cleaning applications and dental surface polishing. The Apex™ Electric Handbiece System device is driven by an electronically controlled DC electric motor with a pneumatic/electronic actuated control system that is connected to the Contra Angle dental instrument via an ISO-3964 coupling. The Apex™ Electric Handpiece System device is indicated for use by dental professionals only.

    Device Description

    The Apex™ Electric Handpiece System is a pneumatic/electronic controlled drive for dental drilling applications. The system consists of (3) components: A commercially-available electronic control system and electric motor and, Contra Angle dental instrument.
    The Apex™ Electric Handpiece System consists of a console type desktop housing with the electronic microprocessor with integrated electric and pneumatic-electric controls, a high-torque motor sealed against lubrication from handpieces with removable motor sleeve and, Contra Angle dental instrument.
    The Apex™ Electric Handpiece System uses a DC controlled micromotor as the driving element of the system, controlled by an electronic microprocessor that is actuated by the practicing dentist's existing air delivery system via foot pedal. Rotation of the dental instrument is controlled by the translation of air to electrical power wherein a wide range of speeds can be achieved and maintained resulting in a precise control of torque and light at the procedure site.

    AI/ML Overview

    The provided text is a 510(k) summary for a dental handpiece system. It pertains to a device that is classified as Class I (general controls) and specifically states that no formal performance data was submitted. This means the document does not contain information about acceptance criteria or a study proving the device meets them in the way one might expect for a higher-risk device that relies on clinical or in-vitro performance studies.

    Instead, the submission relies on demonstrating substantial equivalence to legally marketed predicate devices and adherence to relevant industry standards. The primary "test" described is a biocompatibility/cytotoxicity evaluation.

    Here's an analysis based on your requested information, focusing on what is available and explicitly stating what is not available in this specific document:


    Acceptance Criteria and Device Performance for Apex™ Electric Handpiece System

    Based on the provided 510(k) summary, the primary area where specific "acceptance criteria" and "reported performance" are detailed is regarding biocompatibility/cytotoxicity. For other aspects, the device's acceptability is demonstrated through substantial equivalence to predicate devices and compliance with recognized standards.

    1. Table of Acceptance Criteria and Reported Device Performance

    Criteria CategoryAcceptance CriteriaReported Device Performance
    Biocompatibility - CytotoxicityGrade zero (0) = No Cellular Destruction, indicating no cytotoxicity substances were extractable.Grade zero (0) = No Cellular Destruction was indicated. "The 3 Lares Handpiece samples tested... gave No indication that any cytotoxicity substances were extractable."
    Functional EquivalenceDevice characteristics (e.g., indications for use, input voltage, materials, drive delivery, sterilization features, speeds, lighting, water spray, bur release, coupler, autoclavability) are substantially equivalent to the predicate devices (Bien Air ORL-E-92 Surgical Drill System, W & H Synea WA-99LT, NSK Speed Increaser Contra Angle).The comparison tables (Section XII) show "Yes" for Substantial Equivalence across all listed technical characteristics when compared to the Bien Air ORL-E-92 and another Bien Air Contra Angle (though the latter's model number is not explicitly listed at the top of the column, it can be inferred from the context of the comparison). The narrative explicitly states the device is "substantially equivalent" in design, speed, rotation, irrigation, and autoclavability.
    Standards ComplianceMeets all applicable ISO, IEC, and FDA Guidance Standards."Lares Research, Inc. has taken all steps necessary to assure that the Apex™ Electric Handpiece System meets all applicable ISO, IEC and FDA Guidance Standards listed in Section XV of this document."

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size:
      • For the biocompatibility/cytotoxicity evaluation: Three (3) separate Lares Handpiece samples were tested.
      • For functional equivalence (comparison to predicate devices) and standards compliance: Not applicable in the same way as a clinical study. The device itself is the "test article" compared against specifications and predicate device characteristics.
    • Data Provenance:
      • Biocompatibility/cytotoxicity evaluation: Conducted by Nelson Laboratories (Salt Lake City, UT). The report is dated June 19, 2003. This is an in vitro test.
      • Functional equivalence and standards compliance: Based on internal assessment by Lares Research, Inc. and comparison to publicly available information or specifications of predicate devices and standards. This is not "data provenance" in the clinical study sense.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Biocompatibility/Cytotoxicity: The ground truth (assessment of cellular destruction) was established by the Nelson Laboratories personnel conducting the in vitro MEM Elution test. The document does not specify the number or qualifications of these experts beyond stating the lab conducted the evaluation. It's a laboratory test with objective scoring criteria, rather than expert interpretation of complex clinical data.
    • Functional Equivalence/Standards Compliance: The "ground truth" here is the established specifications of the device and the predicate devices, and the requirements of the standards. The comparison was performed by Lares Research, Inc., as part of their 510(k) submission. No external "experts" were explicitly mentioned for subjective "ground truth" establishment in this context.

    4. Adjudication Method for the Test Set

    • Biocompatibility/Cytotoxicity: The grading of cellular destruction (Grade 0) is based on a standardized and objective laboratory assay (MEM Elution). No explicit "adjudication method" (like 2+1 or 3+1 for expert review) is mentioned or likely relevant for this type of in vitro test. The result is a direct observation and scoring based on the test protocol.
    • Other aspects: Not applicable as there isn't a "test set" requiring adjudication in the context of clinical or image-based studies.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size of Human Readers Improve with AI vs. Without AI Assistance

    • No, an MRMC comparative effectiveness study was not done. This document pertains to a dental handpiece (a mechanical device), not an AI or imaging diagnostic tool. Therefore, discussions of human reader improvement with AI assistance are irrelevant to this submission.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • No, performance of an algorithm (standalone or otherwise) was not done. This document is for a physical dental handpiece system, not a software algorithm.

    7. The Type of Ground Truth Used

    • Biocompatibility/Cytotoxicity: Objective laboratory measurements/observations of cellular destruction in an in vitro MEM Elution test, scored based on established criteria for such assays.
    • Functional Equivalence: Comparison against predicate device technical specifications and performance characteristics and recognized industry standards.

    8. The Sample Size for the Training Set

    • Not applicable. There is no "training set" for this type of device submission. The device is a mechanical tool, not a machine learning model.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As there is no training set, there is no ground truth for it.

    Summary:

    This 510(k) submission for the Apex™ Electric Handpiece System primarily relies on demonstrating:

    1. Biocompatibility through a specific in vitro cytotoxicity test on 3 samples, which showed no cellular destruction.
    2. Substantial Equivalence to existing legally marketed predicate devices by comparing technical characteristics (design, speed, control, sterilization, etc.).
    3. Compliance with recognized industry standards (ISO, IEC, FDA Guidance Standards).

    The document explicitly states that "No formal performance data was submitted for this Class I device." This is typical for Class I devices where safety and effectiveness are largely demonstrated through adherence to general controls, standards, and substantial equivalence to market predecessors, rather than extensive clinical performance trials.

    Ask a Question

    Ask a specific question about this device