510(k) Data Aggregation

    K Number
    K231967
    Date Cleared
    2023-12-07

    (157 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ARi ExCon Implant System is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function in the following situations and with the clinical protocols:

    • Delayed loading

    • Immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    For TiGEN Abutment and ZrGEN Abutment, all digitally designed abutments for use with TiGEN Abutment and ZrGEN Abutment are intended to be sent to a MegaGen-validated milling center for manufacture.

    Device Description

    The ARi ExCon Implant is a substructure of a dental implant system made of CP Ti Grade 4 with the surface treated by SLA method. It is intended to be placed in the maxillary or mandibular areas to restore masticatory function.
    The Abutments are prosthetic components directly or indirectly connected to the endosseous dental implant and are intended for use as an aid in prosthetic rehabilitation, allows single & multiple prosthetic restorations.

    AI/ML Overview

    The provided text is an FDA 510(k) premarket notification summary for the "ARi ExCon Implant System." It details various components of the dental implant system (implants, cover screws, healing abutments, etc.) and compares them to predicate and reference devices to demonstrate substantial equivalence.

    However, the document does not contain information about a study that proves the device meets specific acceptance criteria in the context of an AI/human-in-the-loop performance study, such as an MRMC study. The "Performance test" section on page 25-26 only mentions fatigue testing according to ISO 14801 and "Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutment" to evaluate the performance of subject devices (implant components), and that test results met pre-set criteria. This is a mechanical performance test, not a clinical or human-reader study.

    Therefore, I cannot fulfill the request for information regarding:

    1. A table of acceptance criteria and reported device performance (in the context of AI/human performance).
    2. Sample size for the test set and data provenance.
    3. Number of experts and their qualifications for ground truth.
    4. Adjudication method.
    5. MRMC comparative effectiveness study results or effect size.
    6. Standalone (algorithm-only) performance.
    7. Type of ground truth used (clinical/AI performance).
    8. Training set sample size.
    9. How training set ground truth was established.

    The document primarily focuses on demonstrating substantial equivalence of the dental implant components through material comparisons and mechanical bench testing to predicate and reference devices, not on the performance of a medical AI device or human-in-the-loop performance with AI assistance.