510(k) Data Aggregation

    K Number
    K251850
    Device Name
    Phantom® Hindfoot TTC/TC Nail System
    Manufacturer
    Paragon 28, Inc
    Date Cleared
    2025-07-14

    (28 days)

    Product Code
    HSB
    Regulation Number
    888.3020
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Device Description
    Ask a Question
    K Number
    K250641
    Device Name
    APEX 3D Total Ankle Replacement System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2025-05-01

    (58 days)

    Product Code
    HSN
    Regulation Number
    888.3110
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The APEX 3D™ Total Ankle Replacement System is indicated as a total ankle replacement in primary surgery for patients with ankle joints damaged by severe rheumatoid, post traumatic, or degenerative arthritis. Revision surgery for these patients is also indicated for patients with sufficient bone stock present. In the United States, components are intended for cemented use only.
    Device Description
    The APEX 3D Total Ankle Replacement System has been cleared under K192994. The purpose of this submission is to introduce a new diffusion bonded talar dome to the APEX 3D Total Ankle Replacement System. The APEX 3D Total Ankle Replacement System is a cemented, fixed-bearing device comprised of a tibial component, a talar component, and a UHMWPE component used for ankle joint replacement. Based on patient anatomy, a number of component sizes and design configurations can be selected for best fit.
    Ask a Question
    K Number
    K242452
    Device Name
    Monkey Bars Pin to Bar External Fixation System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-11-01

    (74 days)

    Product Code
    KTT
    Regulation Number
    888.3030
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Monkey Bars Pin to Bar External Fixation System is intended to be used in adult and pediatric patients (specifically, children and adolescents aged 2 through 21 years) for provisional fixation of open and/or unstable fractures in the lower and upper extremities and pelvis. It may also be used for temporary fixation of peri-articular or intra-articular fractures. Additionally, the device can be used on fractures where soft tissue injury or an infected fracture site may preclude the use of other fracture fixation treatments.
    Device Description
    The device is used for the external stabilization of bone fractures. It consists of: Carbon fiber composite bars, 11mm diameter by 150mm to 500mm lengths, titanium combination clamp, aluminum 5 & 8 hole multi-pin clamps, aluminum straight and 30 degree angled posts, stainless steel 3mm, 4mm and 5mm thread diameter pins with 5mm diameter shanks that come in blunt tip and self tapping with 125mm through 230mm overall lengths and 20mm through 65mm thread lengths, stainless steel transfixing pin with 5mm shank, 7.2mm thread diameter, and 325mm overall length, and stainless steel instruments for implantation. The pins are implanted into bone and then they are connected using the clamps, rods and posts to form a rigid construct which holds the bone fragments rigidly in place. The pins are offered in various lengths and thicknesses.
    Ask a Question
    K Number
    K234128
    Device Name
    Phantom Fibula Nail System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-08-22

    (238 days)

    Product Code
    HSB
    Regulation Number
    888.3020
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Phantom Fibula Nail System is intended for use in the fixation of fibular fractures and osteotomies.
    Device Description
    The Phantom Fibula Nail System consists of nails, screws, and accessories for the intended use of fibula repair. The implants are provided in multiple sizes and lengths.
    Ask a Question
    K Number
    K241864
    Device Name
    Grappler Interference Screw System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-07-25

    (28 days)

    Product Code
    MBI
    Regulation Number
    888.3040
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Device Description
    Ask a Question
    K Number
    K240259
    Device Name
    APEX 3D Total Ankle Replacement System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-06-24

    (145 days)

    Product Code
    HSN
    Regulation Number
    888.3110
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The APEX 3D Total Ankle Replacement System is indicated as a total ankle replacement in primary surgery for patients with ankle joints damaged by severe rheumatoid, post-traumatic, or degenerative arthritis. Revision surgery for these patients is also indicated for patients with sufficient bone stock present. In the United States, components are intended for cemented use only.
    Device Description
    The APEX 3D Total Ankle Replacement System is a cemented, fixed-bearing device comprised of a tibial component, a talar component, and a UHMWPE component used for ankle joint replacement. Based on patient anatomy, a number of component sizes and design configurations can be selected for best fit.
    Ask a Question
    K Number
    K241262
    Device Name
    Baby Gorilla/Gorilla Plating System; Monster Screw System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-06-05

    (30 days)

    Product Code
    HRS, HTN, HWC
    Regulation Number
    888.3030
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Baby Gorilla/Gorilla Bone Plates and Bone Screws of the Baby Gorilla/Gorilla Plating System are indicated for use in stabilization of fractures or osteotomies; intra and extra articular fractures, ioint depression, and multi-fragmentary fractures: revision procedures, joint fusion and reconstruction of small bones of the toes, feet and ankles including the distal tibia, talus, and calcaneus, as well as the fingers, hands, and wrists. The system can be used in both and pediatric patients. Specific examples include: Forefoot: Arthrodesis of the first metatarsalcuneiform joint (Lapidus Fusion), Metatarsal or phalangeal fractures and osteotomies, Lesser metatarsal shortening osteotomies (e.g. Weil), Fifth metatarsal fractures (e.g. Jones Fracture). Mid/Hindfoot: LisFranc Arthrodesis and/or Stabilization, 1st (Lapidus), 2nd, 3rd, 4th, and 5th Tarsometatarsal (TMT) Fusions, Intercuneiform Fusions, Navicular-Cuneiform (NC) Fusion, Talo-Navicular (TN) Fusion, Calcaneo-Cuboid (CC) Fusion, Subtalar Fusion, Medial Column Fusion, Cuneiform Fracture, Cuboid Fracture, Navicular Fracture. Ankle: Lateral Malleolar Fractures, Syndesmosis Injuries, Medial Malleolar Fractures and Osteotomies, Bi-Malleolar Fractures, Tri-Malleolar Fractures, Posterior Malleolar Fractures, Distal Anterior Tibia Fractures, Vertical Shear Fractures of the Medial Malleolus, Pilon Fractures, Distal Tibia Shaft Fractures, Distal Fibula Shaft Fractures, Distal Tibia Periarticular Fractures, Medial Malleolar Avulsion Fractures, Lateral Malleolar Avulsion Fractures, Tibiotalocalcaneal Joint Arthrodesis, Tibiotalar Joint Arthrodesis, Tibiocalcaneal Arthrodesis, Supramalleolar Osteotomy, Fibular Osteotomy, First metatarsal osteotomies for hallux valgus correction including: Opening base wedge osteotomy, Closing base wedge osteotomy, Crescentic Osteotomy, Proximal Osteotomy (Chevron and Rotational Oblique), Distal Osteotomy (Chevron/Austin), Arthrodesis of the first metatarsophalangeal joint (MTP) including: Primary MTP Fusion due to hallux ridgidus and/or hallux valgus, Revision MTP Fusion, Revision of failed first MTP Arthroplasty implant. Flatfoot: Lateral Column Lengthening (Evans Osteotomy), Plantar Flexion Opening Wedge Osteotomy of the Medial Cuneiform (Cotton Osteotomy), Calcaneal Slide Osteotomy. Charcot: Medial column fusion (talus, navicular, cuneiform, metatarsal) for neuropathic osteoarthropathy (Charcot), Lateral column fusion (calcaneus, cuboid, metatarsal) for neuropathic osteoarthropathy (Charcot). In addition, the non-locking, titanium screws and washers are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture fixation, appropriate for the size of the device. The Monster Screw System is indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, ligament fixation, fracture repair and fracture fixation, appropriate for the device. Specific examples include: Fractures and Osteotomies: Fractures of the tarsals, metatarsals and other fractures of the foot (i.e. LisFranc), Avulsion fractures and fractures of the 5th metatarsal (i.e. Jones Fracture), Talar fractures, Ankle fractures, Navicular fractures, Fractures of the fibula, malleolus, and calcaneus, Metatarsal and phalangeal osteotomies, Weil osteotomy, Calcaneal osteotomy. Hallux Valgus Correction: Fixation of osteotomies (i.e. Akin, Scarf, Chevron), Interphalangeal (IP) arthrodesis, Proximal, midshaft, or distal osteotomy, Lapidus arthrodesis. Arthrodesis/Deformity Correction: 1st MTP arthrodesis, Metatarsal deformity correction, Tarsometatarsal joint arthrodesis, Naviculocuneiform joint arthrodesis, Talonavicular arthrodesis, Subtalar joint arthrodesis, Triple arthrodesis, Medial column arthrodesis, Subtalar joint distraction arthrodesis, Ankle arthrodesis, Lateralizing calcaneal osteotomy, Lateral column lengthening, Hammertoe. Fusion resulting from neuropathic osteoarthropathy (Charcot) such as: Medial and lateral column, Subtalar, talonavicular, and calcaneocuboid.
    Device Description
    Baby Gorilla/ Gorilla Plating System: The Baby Gorilla/Gorilla Plating System is comprised of bone plates, threaded bone screws, and washers. Gorilla Plates are offered in “mini” and “standard” set sizes in a variety of shapes based upon the anatomical fixation required. Screws are also offered in “mini” and “standard” sets and, in addition, in locking and non-locking versions. Size-matched washers are available for use with the non-locking screws when the latter are used for fixation without the plates. Size-matched plate washers are also available for use with plate holes when there is no desire to use a screw. The Baby Gorilla/Gorilla Plating System implants are manufactured from medical grade titanium (per ASTM F67), stainless steel (per ASTM E138) and titanium alloy (per ASTM. Monster Screw System: The Monster Screw System is comprised of threaded bone screws (Ti Alloy or Stainless Steel) offered in 2.0mm to 9.5mm diameters (in 0.5mm increments). In addition, a 2.7mm diameter is also part of the system. The overall screw length ranges from 8mm (for smaller diameters) thru 200mm (for larger diameters). The screws are available in a variety of designs including fully or partially threaded, self-drilling or blunt, cannulated or solid, and headed or headless. Sized-matched washers are also available.
    Ask a Question
    K Number
    K240594
    Device Name
    Grappler Suture Anchor R3FLEX IOL System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2024-03-26

    (22 days)

    Product Code
    MBI
    Regulation Number
    888.3040
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Grappler Suture Anchor R3FLEX IOL System is intended for the fixation of soft tissue to bone including: Elbow: Biceps Tendon Reattachment, Lateral Epicondylitis Repair, Tennis Elbow Repair Shoulder: Rotator Cuff Repair, Bankart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Repair Hand/Wrist: Scapholunate Ligament Reconstruction, Ulnar or Radial Collateral Ligament Reconstruction, TFCC Foot/Ankle: Lateral Stabilization (Brostrom, Brostrom-Gould, Christman-Snook Repair), Ankle Ligament Repair, Medial Stabilization (Deltoid, Spring Ligament Repair), Achilles Tendon Repair, Metatarsal Ligament Repair, Syndesmosis Repair, Hallux Valgus Reconstruction, Digital Tendon Transfers, Mid-foot Reconstruction, LisFranc Repair Knee: Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis, Extra Capsular Reconstruction, Patellar Ligament and Tendon Avulsion Repair Hip: Capsular Repair, Acetabular Labral Repair The plate interacting anchors are only indicated for the above Hand/Wrist and Foot/Ankle indications.
    Device Description
    The Grappler Suture Anchor R3FLEX IOL System consists of suture anchors, suture, and the accompanying instrumentation for the intended use of soft tissue damage repair. The anchors are provided in titanium and all-suture and are connected by suture composed of UHMWPE.
    Ask a Question
    K Number
    K232838
    Device Name
    Monkey RingsTM External Fixation System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2023-10-12

    (28 days)

    Product Code
    KTT
    Regulation Number
    888.3030
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Monkey Rings™ External Fixation System is indicated in pediatric patients and adults for the treatment and fixation of: - · Open and closed fractures - · Post-traumatic joint contracture which has resulted in loss of range of motion - · Fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction - · Pseudoarthrosis, infected union, non-union, or malunion of long bones - · Limb lengthening by epiphyseal, diaphyseal, or metaphyseal distraction - · Correction of bony or soft tissue deformity (e.g. orthoplastic surgery) - · Correction of segmental bony or soft tissue defects - · Joint arthrodesis - · Management of comminuted intra-articular fractures - · Bone transport The Monkey Rings™ External Fixation System is indicated in adults for: - · Osteotomy - · Revision procedure where other treatments or devices have been unsuccessful - · Bone reconstruction procedures - · Fusions and replantations of the foot - · Charcot foot reconstruction - · Offloading and/or immobilization of ulcers and/or wounds of the foot and ankle - · Lisfranc dislocations - · Ankle distraction (arthrodiastasis) - · Septic fusion
    Device Description
    The Monkey Rings™ External Fixation System is a modular, ring-based, external fixation system designed for the treatment and fixation of a variety of conditions in pediatric and adult patients. The Monkey Rings™ External Fixation System utilizes wires, pins, struts, rods, bolts, fasteners, clamps, and plates that connect to rings statically placed or gradually manipulated in order to fixate or correct the bone. The modular design of the system allows for a customized treatment for the patient. Components of the Monkey Rings™ External Fixation System may be used in conjunction with all Paragon 28 legally marketed devices. The components of the device are offered in a variety of sizes, which allow for a truly customized external fixation device.
    Ask a Question
    K Number
    K231867
    Device Name
    Grappler Suture Anchor System
    Manufacturer
    Paragon 28, Inc.
    Date Cleared
    2023-08-21

    (56 days)

    Product Code
    MBI
    Regulation Number
    888.3040
    Why did this record match?
    Applicant Name (Manufacturer) :

    Paragon 28, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The GRAPPLER Suture Anchor System is intended for the fixation of soft tissue to bone including: Elbow: Biceps Tendon Reattachment, Lateral Epicondylitis Repair, Tennis Elbow Repair Shoulder: Rotator Cuff Repair, Bankart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Repair Hand/Wrist: Scapholunate Ligament Reconstruction, Ulnar or Radial Collateral Ligament Reconstruction, TFCC Foot/Ankle: Lateral Stabilization (Brostrom, Brostrom-Gould, Christman-Snook Repair), Ankle Ligament Repair, Medial Stabilization (Deltoid, Spring Ligament Repair), Achilles Tendon Repair, Metatarsal Ligament Repair, Syndesmosis Repair, Hallux Valgus Reconstruction, Digital Tendon Transfers, Mid-foot Reconstruction, LisFranc Repair Knee: Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis, Extra Capsular Reconstruction, Patellar Ligament and Tendon Avulsion Repair Hip: Capsular Repair, Acetabular Labral Repair The plate interacting anchors are only indicated for the above Hand/Wrist and Foot/Ankle indications.
    Device Description
    The GRAPPLER Suture Anchor System consists of suture anchors, suture, and the accompanying instrumentation for the intended use of soft tissue damage repair. The anchors are provided in PEEK, titanium, and suture materials in multiple sizes and lengths. Each anchor is accompanied by round suture or suture tape composed of UHMWPE and PGLA.