Found 63 results

510(k) Data Aggregation

    K Number
    K251052
    Device Name
    Trivicta® Hip Stem
    Manufacturer
    Ortho Development Corp.
    Date Cleared
    2025-05-22

    (49 days)

    Product Code
    MEH, KWL, LPH, LZO
    Regulation Number
    888.3353
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corp

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    This device is intended for use in total and hemi-hip arthroplasty. The device is intended for uncemented, press-fit use only in cases of: 1. Notably impaired hip joint due to osteoarthritis, rheumatoid arthritis, and/or post traumatic arthritis. 2. Previously failed hip surgery. 3. Proximal femoral neck fractures or dislocation. 4. Idiopathic avascular necrosis of the femoral head. 5. Non-union of proximal femoral neck fractures. 6. Treatment of fractures that are unmanageable using other forms of therapy. 7. Benign or malignant bone tumors, congenital dysplasia or other structural abnormalities where sufficient bone stock exists to properly seat the prosthesis.
    Device Description
    The subject device is a set of smaller stems that extends the size range of the previously cleared Trivicta® stems (K233758). Trivicta® is a single-piece, tapered, collared and non-collared, hydroxyapatite (HA) and sintered bead commercially pure (Cp) Titanium coated femoral hip stem designed for single use. The stem has a neck with a 12/14 trunnion taper for modular attachment to femoral heads. Trivicta® is manufactured from titanium alloy and device fixation is achieved through uncemented press-fit in the medullary canal and through the use of biocompatible HA coating and porous sintered bead coating. The size range of the subject device is: lengths (97-101mm), horizontal offsets (36-43mm), vertical offsets (27-29mm), resection angle of 41°, and neck angle of 132°. The stem is offered with both standard (STD) and extended (EXT) offsets and with and without a collar. Trivicta® is compatible with the following Ortho Development® devices: CoCr Femoral Heads, Biolox Delta Ceramic Femoral Heads, Solitude™ Unipolar Head, Escalade Acetabular Cup System, Legend® Acetabular Liner, Escalade Legend® Acetabular Shell, and Tri-plus™ DCM Liner.
    Ask a Question
    K Number
    K242984
    Device Name
    BKS Revision System
    Manufacturer
    Ortho Development Corp.
    Date Cleared
    2024-10-25

    (29 days)

    Product Code
    JWH, MBH
    Regulation Number
    888.3560
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corp

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    - 1. Loss of joint configuration and joint function. - 2. Osteoarthritis of the knee joint. - 3. Rheumatoid arthritis of the knee joint. - 4. Post-traumatic arthritis of the knee joint. - 5. Valgus, varus, or flexion deformities of the knee joint. - 6. Revision procedures where other treatments or devices have failed. The BKS, BKS TriMax, and BKS Revision are intended for total knee arthroplasty procedures. The BKS is indicated in the salvage of previously failed surgical attempts where bone loss does not require the use of augments or stem extensions and where collateral ligaments may be relied upon for medial/lateral (M/L) stability. BKS TriMax is intended in the salvage of previously failed surgical attempts where bone loss does not require the use of augments or stem extensions, where collateral ligaments may be relied upon for medial/lateral stability, where postoperative flexion up to 150° may be desirable, and the patient meets all indications requirements. The BKS Revision system is indicated in the salvage of previously failed surgical attempts where bone loss may require the use of augments, sleeves or stem extensions. The BKS Revision system is indicated for cemented use only. The porous-coated metaphyseal sleeves are intended for cemented and uncemented applications. The BKS Revision CK Tibial Insert is indicated for use with the BKS Revision Modular femoral and Modular, Offiset, or Sleeve tibial components where collateral ligaments may not be relied upon for medial/lateral (M/L) stability.
    Device Description
    The purpose of this special 510(k) submission is to request clearance for BKS Revision Sleeve Junction Box of the BKS Revision System which is an extension of Ortho Development's previously cleared predicate BKS Revision Sleeves System (K181569). The subject device incorporates the same locking taper interface for mating with the BKS Revision Sleeves and the same principle of operation for locking the A/P position relative to the BKS Revision Modular Femoral Component. The subject device is manufactured in the same manner from the same material. The subject device also employs the same packaging components and sterilization method. Differences between the subject and predicate device include small adjustments to the envelope geometry, internal configuration, and driving feature for assembly during use. These changes have been made to optimize the Sleeve Junction Box for use specifically with femoral sleeves. The mechanics of the connection and locking mechanism are the same as the predicate device.
    Ask a Question
    K Number
    K242833
    Device Name
    Legend® Acetabular Shell
    Manufacturer
    Ortho Development Corp.
    Date Cleared
    2024-10-11

    (22 days)

    Product Code
    LPH, LZO
    Regulation Number
    888.3358
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corp

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    This device is intended for use in total hip arthroplasty. The device is intended for uncemented, press-fit use only in cases of: - Notably impaired hip joints due to osteoarthritis, rheumatoid arthritis and/or post traumatic arthritis. - Previously failed hip surgery. - Fractures of the femoral neck or head. - Avascular necrosis of the femoral head. - Congenital dysplasia or other structural abnormalities where stock exists to properly seat the prosthesis.
    Device Description
    The Legend® Acetabular Shell is a one-piece, hemispherical shell prostheses, designed for single, uncemented use. Device fixation is achieved via press-fit into a prepared acetabulum, which maximizes contact between the shell and bone. The Legend® Acetabular Shell is manufactured from titanium alloy Ti-6A1-4V ELI per ASTM F136. The outer surface of the shells are coated with commercially pure titanium (CPT)(ASTM F1580) sintered porous coating. The inner surface of the shell is designed to lock together with the Escalade® and Legend® Acetabular Liners which are made from extensively cross-linked polyethylene. The Legend® Acetabular Shell is also designed to be used with cancellous bone screws and apical plugs. The existing Legend® Acetabular Shell (K161080) is coated with commercially pure titanium (CPT) sintered bead coating. This submission allows a similar sintered coating to be applied by an additional supplier: Avalign Thortex (MAF-2607) in addition to the original supplier.
    Ask a Question
    K Number
    K233758
    Device Name
    Trivicta™ Hip Stem
    Manufacturer
    Ortho Development Corp.
    Date Cleared
    2024-03-08

    (105 days)

    Product Code
    MEH, KWL, LPH, LZO
    Regulation Number
    888.3353
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corp

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    This device is intended for use in total and hemi-hip arthroplasty. The device is intended for uncemented, press-fit use only in cases of: 1. Notably impaired hip joint due to osteoarthritis, rheumatoid arthritis, and/or post traumatic arthritis. 2. Previously failed hip surgery. 3. Proximal femoral neck fractures or dislocation. 4. Idiopathic avascular necrosis of the femoral head. 5. Non-union of proximal femoral neck fractures. 6. Treatment of fractures that are unmanageable using other forms of therapy. 7. Benign or malignant bone tumors, congenital dysplasia or other structural abnormalities where sufficient bone stock exists to properly seat the prosthesis.
    Device Description
    Trivictal is a single-piece, tapered, collared and non-collared, hydroxyapatite (HA) and sintered bead commercially pure (Cp) Titanium coated femoral hip stem designed for single use. The stem has a neck with a 12/14 trunnion taper for modular attachment to femoral heads. Trivicta is manufactured from titanium alloy and device fixation is achieved through uncemented press-fit in the medullary canal and through the use of biocompatible HA coating and porous sintered bead coating. The stem has a variety of sizes to accommodate most patients encountered: lengths (101-119mm), horizontal offsets (38-53mm), vertical offsets (29-36mm), resection angle of 41°, and neck angle of 132°. The stem is offered with both standard (STD) and extended (EXT) offsets and with and without a collar. Trivicta™ is compatible with the following Ortho Development devices: CoCr Femoral Heads, Biolox Delta Ceramic Femoral Heads, Solitude™ Unipolar Head, Escalade Acetabular Cup System, Legend® Acetabular Liner, Escalade Legend® Acetabular Shell, and Tri-plus™ DCM Liner.
    Ask a Question
    K Number
    K233093
    Device Name
    Balanced Knee® System TriMax PS Plus Tibial Insert
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2023-10-25

    (29 days)

    Product Code
    JWH
    Regulation Number
    888.3560
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Balanced Knee System TriMax PS Plus Tibial Inset is in cemented total knee arthroplasty procedures with the following indications: 1. Loss of knee joint configuration and joint function. 2. Osteoarthritis of the knee joint. 3. Rheumatoid arthritis of the knee joint. 4. Post-traumatic arthritis of the knee joint. 5. Valgus, varus, or flexion deformities of the knee joint. 6. Revision procedures where other treatments or devices have failed.
    Device Description
    The Balanced Knee® System (BKS) TriMax PS Plus Tibial Insert is a line extension of the TriMax PS Tibial Insert (K131337) that offers slightly more constraint than the original PS Insert. The PS post geometry is the only design difference between the previously cleared predicate device and the subject device. The change slightly modifies the post's shape to provide additional internal/external and varus/valgus constraint if the surgeon determines the need exists. The balance of the design is identical including the articulating surface, locking mechanism, as well as the PS post location and height. The PS Plus inserts are intended for use in primary and revision knee surgeries with the same indications for use as the predicate. This implant is used with existing BKS and BKS Revision (BKSR) tibial travs. TriMax femoral components and the BKSR modular femoral components. The material is identical as well as all manufacturing processes, cleaning, sterilization and packaging that were cleared under K131337.
    Ask a Question
    K Number
    K211086
    Device Name
    The Progen™ Trochanteric Nail System
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2021-12-21

    (253 days)

    Product Code
    HSB, JDS
    Regulation Number
    888.3020
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Progen™ short trochanteric nail is indicated for fixation of various types of stable and unstable neck, intertrochanteric, and peritrochanteric fractures. The Progen™ long trochanteric nail is intended for fixation of stable femoral fractures occurring from the base of the femoral neck extending distally to a point approximal to the intercondylar notch including fractures of the basilar neck, intertrochanteric fractures, subtrochanteric fracture, femoral shaft fractures, pathological fractures, impending pathological fractures, tumor resection, nonunion, and revisions. The Progen™ long trochanteric nail is intended for fixation of stable and unstable femoral fractures occurring from the base of the femoral neck extending distally to a point approximately 10cm proximal to the intercondylar notch including fractures of the basilar neck, intertrochanteric fractures, peritrochanteric fractures, subtrochanteric fracture, femoral shaft fractures, pathological fractures, impending pathological fractures, tumor resection, nonunion, malunion, and revisions.
    Device Description
    The Progen™ Trochanteric Nail System consists of temporary fixation intramedullary nails and their accompanying instrumentation designed for fracture fixation and stabilization of the femur. The implants are available in various lengths and diameters to accommodate a range of patient anatomy. Each of the intramedullary nails is secured by a sequence of screws that transect through holes in the proximal and distal sections of each nail. The Progen™ Trochanteric Nail System consists of single-use intramedullary nails for stable and unstable neck, intertrochanteric, pertrochanteric, and subtrochanteric fractures and combinations of these fractures. The system consists of Nail, Lag Screw, Secondary Screw, Lag Cap, Locking Screws, Set Screws, and Nail End Cap. The nails and accompanying components are manufactured from titanium alloy (Ti-6Al-4V ELI). Additionally, the Nails and Lag Screws have a Type II anodized surface treatments.
    Ask a Question
    K Number
    K211471
    Device Name
    Balanced Knee System Uni
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2021-12-16

    (219 days)

    Product Code
    HSX
    Regulation Number
    888.3520
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    1. Non-inflammatory degenerative joint diseases (NIDJD), e.g., osteoarthritis, avascular necrosis 2. Traumatic arthritis 3. Previous tibial condyle or plateau fracture with loss of anatomy or function 4. Varus deformities 5. Revision of the tibial bearing insert of a previously implanted unicompartmental knee system provided that the tibial tray mechanism is not compromised, and femoral and tibial tray components remain well fixed and undamaged. The BKS Uni is intended for unicompartmental knee arthroplasty procedures. The system is single-use and intended for implantation with bone cement.
    Device Description
    The Balanced Knee® System (BKS®) Uni is a single compartment knee replacement. The BKS Uni is indicated for cemented use only. Cobalt Chromium Femoral Component The femoral components are cobalt chromium (Co-Cr-Mo). The femoral components are right and left specific and are intended for cemented use only. Titanium Tibial Trays The titanium tibial trays (Ti-6Al-4V ELI) are left and right specific and are for cemented use only. Polyethylene Tibial Insert The E-Vitalize tibial insert is manufactured from crosslinked Vitamin E Ultra High Molecular Weight Polyethylene. The inserts match the respective size of the tibial tray used.
    Ask a Question
    K Number
    K203023
    Device Name
    Pisces Spinal System
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2021-07-14

    (285 days)

    Product Code
    NKB
    Regulation Number
    888.3070
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Pisces Spinal System is intended to provide immobilization of spinal segments in skeletally mature patients as an adjunct to fusion using autograft. This system is intended for posterior, non-cervical pedicle fixation of the thoracic, lumbar, sacrum and iliac spine (T1-Sacrum/Ilium) for the following indications: 1. Degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) 2. Degenerative Spondylolisthesis with objective evidence of neurologic impairment 3. Trauma (fracture or dislocation) 4. Spinal tumor 5. Failed previous fusion (pseudarthrosis) 6. Spinal stenosis 7. Spinal deformities or curvatures such as scoliosis, kyphosis, or lordosis
    Device Description
    The Pisces Spinal System is an implantable system intended to provide immobilization and stabilization of spine segments. The subject device is a modular pedicle screw assembly that consists of pedicle screws with solid and cannulated options, modular tulips in standard, reduction, and extended tab configurations, spinal rods, and set screws. All components are made of implantable-grade titanium. The modular tulip is an assembly which consists of a tulip body, a saddle, and a locking ring. The top of the tulip body receives a locking set screw which secures the tulip body assembly to an ø5.5mm or ø6.0mm rod and pedicle screw when tightened. The pedicle screw has a spherical head which the tulip assembly snaps onto either before or after surgical insertion. The 5.5mm or 6.0mm rod is inserted into the tulip assembly. After assembly of multiple pedicle screws, a set screw is inserted into the tulip and locked to a predetermined locking torque, immobilizing the construct. For the 20mm reduction and 90mm extended tab tulips, the guide tabs are removed from the construct following final lock. 20mm reduction tabs can be used to provide length for rod reduction while 90mm tab tulips facilitate minimally invasive surgeries (MIS). All implants are provided sterile for single use only.
    Ask a Question
    K Number
    K200281
    Device Name
    The Gecko Spinal System
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2020-03-31

    (56 days)

    Product Code
    OWI
    Regulation Number
    888.3010
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Gecko Spinal System is a temporary implant for use in orthopedic surgery. The system is intended to provide temporary stabilization as a bone anchor during the development of solid bony fusion and aid in the repair of bone fractures. The indications for use include the following applications: 1. Spinal trauma surgery, used in sublaminar or facet wiring techniques; 2. Spinal reconstructive surgery, incorporated into constructs for the purpose of correction of spinal deformities such as idiopathic and neuromuscular scoliosis in patients 8 years of age and older, adult scollosis, kyphosis and spondylolisthesis; 3. Spinal degenerative surgery, as an adjunct to spinal fusions. The Gecko Spinal System may also be used in conjunction with other Ortho Development's spinal rod systems made of similar metals whenever "wiring" may help secure the attachment of the other implants.
    Device Description
    The Gecko Spinal System is an implantable device intended to provide immobilization and stabilization of spinal segments. The device consists of an implantable polyethylene terephthalate (PET) braided band with a stiffened guiding section at one end and a metal leader at the other (both removed before final implantation), an implantable grade titanium alloy clamp that mates with 5.5mm diameter rods, and an implantable grade titanium alloy nut that secures the band, clamp, and connecting rod together. All implants are provided sterile for single use only; the implant should not be re-used or re-sterilized under any circumstances.
    Ask a Question
    K Number
    K182085
    Device Name
    Balanced Knee Revision System Trabecular Tibial Cone Augments
    Manufacturer
    Ortho Development Corporation
    Date Cleared
    2018-10-31

    (90 days)

    Product Code
    JWH, MBH
    Regulation Number
    888.3560
    Why did this record match?
    Applicant Name (Manufacturer) :

    Ortho Development Corporation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    These devices are intended for use in total knee arthroplasty procedures for the following conditions: 1. Loss of joint configuration and joint function. 2. Osteoarthritis of the knee joint. 3. Rheumatoid arthritis of the knee joint. 4. Post-traumatic arthritis of the knee joint. 5. Valgus, varus, or flexion deformities of the knee joint. 6. Revision procedures where other treatments or devices have failed. The BKS Revision is indicated in the salvage of previously failed surgical attempts where bone loss may require the use of augments, sleeves, cones or stem extensions. The BKS Revision System Trabecular Tibial Cone Augments are for cemented or cementless use.
    Device Description
    The Balanced Knee® Revision System (BKS® Revision) Trabecular Tibial Cone Augments are an addition to the Balanced Knee® Revision System to provide optional single-use modular cone augment implants used in revision knee surgery. The subject device provides additional support to the tibial implant and reinforcement to the proximal tibia when bone voids are present. The subject device is designed for cemented or uncemented fixation with the bone.