Search Results
Found 13 results
510(k) Data Aggregation
K Number
K150956Device Name
PINPOINT Endoscopic Fluorescence Imaging System
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2016-05-23
(410 days)
Product Code
GCJ, IZI
Regulation Number
876.1500Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The PINPOINT Endoscopic Fluorescence Imaging System is indicated for use to provide real time endoscopic visible and near-infrared fluorescence imaging.
The PINPOINT System enables surgeons to perform minimally invasive surgery using standard endoscope visible light as well as visual assessment of vessels, blood flow and related tissue perfusion, and at least one of the major extra-hepatic bile ducts (cystic duct, common bile duct or common hepatic duct), using near-infrared imaging.
Fluorescence imaging of biliary ducts with the PINPOINT System is intended for use with standard of care white light, and when indicated, intraoperative cholangiography. The device is not intended for standalone use for biliary duct visualization.
Device Description
The PINPOINT Endoscopic Fluorescence Imaging System (PINPOINT, PINPOINT System) is comprised of an endoscopic video processor/ illuminator (VPI) which is capable of providing visible and near-infrared illumination to a surgical laparoscope, surgical laparoscopes optimized for visible (VIS) and near-infrared (NIR) illumination and imaging, a camera head that is also optimized for visible and near-infrared imaging, and a flexible light guide cable. The following laparoscope models are included as part of the PINPOINT System: SC9100, SC9104, SC9130, SC9131, SC9134 and SC9144. These are the major components of the PINPOINT System.
During surgical procedures, PINPOINT may be operated to provide visualization similar to that provided by conventional imaging systems used in surgical endoscopy. The area of interest is illuminated with visible light from the illuminator and the resulting reflected light is imaged by the camera and displayed on the video monitor. When used with the VIS-only laparoscopes, the System is only capable of the conventional mode of visualization described herein.
To provide NIR fluorescence imaging, PINPOINT is used with the imaging agent, indocyanine green (ICG). The patient is injected with ICG imaging agent. The ICG fluoresces when illuminated through the laparoscope with NIR excitation light from the VPI, and the fluorescence response is then imaged with the camera, processed and displayed on an HD video monitor.
When used with a VIS/NIR laparoscope, PINPOINT can operate to provide illumination and imaging of both visible light and ICG fluorescence images simultaneously.
Ask a Question
K Number
K123013Device Name
ENDOSCOPIC INTRODUCER
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2013-03-22
(175 days)
Product Code
FED
Regulation Number
876.1500Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Novadag Disposable Rigid Scope Introducer is intended to facilitate passage of a laparoscope through the anus allowing visual examination of the rectum and distal portions of the colon.
Device Description
The single-use Disposable Rigid Scope Introducer is used in conjunction with a laparoscope to allow visual examination of the rectum and distal portions of the colon. When used with the laparoscope, the Disposable Rigid Scope Introducer and laparoscope are advanced into the rectum under visual guidance to a maximum insertion length of 25cm. An insufflation port is provided as part of the Endoscopic Introducer to allow insufflation of the rectum and lower colon.
Ask a Question
K Number
K100371Device Name
SPY INTRA-OPERATIVE IMAGING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2011-02-04
(357 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY System is intended to provide fluorescence images for the visual assessment of blood flow in vessels and related tissue perfusion during gastrointestinal surgical procedures.
Device Description
The SPY System consists of two components: the SP2001 Imaging Device and the SPY Pag. The SPY System utilizes the fluorescent imaging agent ICG. The SP2001 Imaging Device consists of an imaging head containing a camera, a laser light source, and a distance sensor attached to a mobile cart via an articulating arm. The mobile cart contains a flat panel monitor, a computer with keyboard and mouse, an electronics enclosure, and a printer. While ICG distributes through the vessels or tissues, absorption of laser light at 808 nm causes excitation of the ICG followed by emission of infrared energy at a wavelength of 830 nm. This results in a fluorescent image of the blood vessels and related tissue perfusion. A CCD camera with an 830 nm optical band-pass filter captures the images, Image sequences. up to 60 seconds in duration, are displayed on the monitor and recorded on the computer hard drive. The image sequences can be exported to a CD, DVD, memory stick or lpod. The camera head can be moved in the in horizontal plane during image sequence acquisition. Once the image is captured, the laser automatically shuts off.
Ask a Question
K Number
K091515Device Name
SPY SCOPE INTRA-OPERATIVE OPERATING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2009-07-09
(48 days)
Product Code
GCJ, IZI
Regulation Number
876.1500Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY scope intra-operative imaging system (SPY scope) is intended to provide realtime endoscopic visible and near infrared fluorescence imaging. SPY scope enables surgeons to perform routine visible light endoscopic procedures as well as further visually assess vessels, blood flow and related tissue perfusion with near infra-red imaging during minimally invasive surgery.
Device Description
The SPY® scope provides real-time high definition (HD) endoscopic video images of visible (VIS) and near infrared (NIR) indocyanine green (ICG) dye fluorescence during minimally invasive surgery. During such a procedure, the SPY scope functions like all conventional VIS light imaging systems used in surgical endoscopy. Visible light from the SPY scope light source illuminates the area of interest through the endoscope and the resulting reflected light is imaged by the SPY scope color HD camera and displayed on an HD video monitor.
The SPY scope device is comprised of the following components:
- Endoscopes for VIS and NIR illumination and imaging.
- A 3 CCD (charge coupled device) color video camera head with video coupler and accompanying sterile drape,
- Light source & video processor unit, and
- ICG imaging agent.
Ask a Question
K Number
K081792Device Name
SPY ANALYSIS TOOLKIT, MODEL SA9000
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2008-09-17
(84 days)
Product Code
LLZ
Regulation Number
892.2050Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY Analysis Toolkit is a separate companion software application to the SPY Intra-operative Imaging System and is intended as a display, analysis, and comparison tool for the interpretation of SPY images by trained healthcare professionals including cardiovascular, plastic & reconstructive, and organ transplant surgeons.
Note: The clinician retains the ultimate responsibility for making the pertinent diagnosis based on their standard practices and visual comparison of the separate images. The SPY Analysis Toolkit is a complement to the SPY procedures.
Device Description
The SPY® Analysis Toolkit is a separate companion application to the SPY Intraoperative Imaging System's (SPY System) software, which is currently cleared for use in cardiovascular, plastic and reconstruction, and organ transplant surgeries. The Analysis Toolkit is capable of working cooperatively, as an accessory plug-in feature, with the SPY software or standalone on a physician's desktop computer. The Analysis Toolkit is not real-time.
Novadaq's SPY System allows surgeons (including cardiovascular, plastic and reconstructive, and transplant) to produce real-time images of blood vessels, surrounding tissue and related perfusion of those tissues/organs during various types of surgeries. The Analysis Toolkit provides a set of clinical image analysis tools and makes them available to clinicians for either intra-operative post image acquisition or retrospective analysis. The ultimate goal of analysis will be to provide surgeons with another parameter, in addition to standard of care information, including data from other imaging modalities, for use in pre-operative decision-making and post-operative evaluation of results as an input to post-operative care.
The SPY Analysis Toolkit is a plug-in module to the SPY Imaging Device and does not have any control over the device or the previously cleared software. The SPY Analysis Toolkit is an accessory software feature designed and developed to work with images acquired on the SPY System, models SP2000 and SP2001. The SPY Analysis Toolkit has no capability to modify in any way the underlying images previously acquired intraoperatively by the SPY System. The resolution and the quality of the images captured by the SPY System and analyzed by the SPY Analysis Toolkit remain the same.
The SPY Analysis Toolkit application is for viewing, manipulation, measurement and comparison of medical image sequences produced at single or multiple time-points by the SPY System. Entire image time-sequences are processed for viewing using a variety of analytical algorithms that provide visual or numerical results.
The Analysis Toolkit can also accept DICOM and AVI images independent of the SPY device for post-operative analysis.
Ask a Question
K Number
K073088Device Name
SPY FLUORESCENT IMAGING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2008-01-10
(70 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY Fluorescent Imaging System is an imaging system used in capturing and viewing fluorescent images for the visual assessment of blood flow as an adjunctive method for the evaluation of tissue perfusion, and related tissuetransfer circulation in tissue and free flaps used in plastic, micro- and reconstructive surgical procedures.
Device Description
The SPY Fluorescent Imaging System used in plastic, micro, and reconstructive surgery indication consists of 2 components: the SP2001 Imaging Device and the SPY Paq. The SP2001 Imaging Device consists of an imaging head containing a charge coupled device (CCD) camera, a laser light source, motion sensor, and distance sensor attached via an articulating arm to a mobile cart. The mobile cart contains a flat panel display, a computer with keyboard and optical mouse, an electronics enclosure, and a printer. The SPY System provides the surgeon with the capability to view, record, and replay fluorescent images of blood flow in vessels and organs. A laser light source is used to illuminate the area of interest. In order to obtain the images, ICG is injected intravenously through the central or peripheral venous line. While the ICG is passing through the vessels, the absorption of laser light causes excitation of the ICG dye, followed by the emission of infrared energy. A CCD camera of the SP2000 Imaging Device captures the infrared emission, resulting in a fluorescent image of blood flow and related tissue perfusion. These images are used to evaluate the integrity of native and grafted vasculature and blood flow in the organs. The SP2001 Imaging Device represents minor modifications of the SP2000 Imaging Device: The maximum recording time for image sequences captured has been extended to 60 seconds from the 34 seconds of the SP2000 Imaging Device. An ability to move the SP2001 camera head in horizontal plane during image sequence acquisition has been implemented. A variable Laser Power Attenuator has been added to the device to permit laser illumination at power levels lower or equal to the laser power level of the SP2000 Imaging Device. New HELIOS software has been developed to support the SPY System in its plastic, micro-, and reconstructive surgery indication.
Ask a Question
K Number
K073130Device Name
SPY FLUORESCENT IMAGING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2008-01-10
(65 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY® Fluorescent Imaging System is intended to intra-operatively enable surgeons to visually assess blood flow and related tissue perfusion during organ transplant procedures.
Device Description
The Novadag® Technologies SPY® Fluorescent Imaging System used in plastic, micro, and reconstructive surgery indication consists of 2 components:
- · the SP2001 Imaging Device
- · the SPY Paq®
The SPY Pags are available in 2 configurations dependent on the intended indication for use. Each SPY Paq contains sufficient number of ICG, custom sterile drapes called Novadrape®, and diluent for 6 imaging procedures. Each configuration of SPY Pag has a unique part number assigned to it, and different Instructions for Use exist for the two types of SPY Pags. The different Instructions for Use also have unique part numbers for ease of assembly of the Pags and quidance for the end user.
The SP2000 Imaging Device consists of an imaging head containing a charge coupled device (CCD) camera, a laser light source, motion sensor, and distance sensor attached via an articulating arm to a mobile cart. The mobile cart contains a flat panel display, a computer with keyboard and optical mouse, an electronics enclosure, and a printer.
The SPY® System provides the surgeon with the capability to view, record, and replay fluorescent images of blood flow in vessels and organs. A laser light source is used to illuminate the area of interest. In order to obtain the images, ICG is injected intravenously through the central or peripheral venous line, bypass pump, cardioplegia line, or down a coronary graft. While the ICG is passing through the vessels, the absorption of laser light causes excitation of the ICG dye, followed by the emission of infrared energy. A CCD camera of the SP2000 Imaging Device captures the infrared emission, resulting in a fluorescent image of blood flow and related tissue perfusion. These images are used to evaluate the integrity of native and grafted vasculature and blood flow in the organs.
The SP2001 Imaging Device represents a modification of the SP2000 Imaging Device in the following ways:
- The maximum recording time for image sequences captured has been extended to 60 seconds from the 34 seconds of the SP2000 Imaging Device.
- An ability to move the SP2001 camera head in horizontal plane during image sequence acquisition has been implemented.
- A variable Laser Power Attenuator has been added to the device to permit laser illumination at power levels lower or equal to the laser power level of the SP2000 Imaging Device.
- New HELIOS 10 software has been developed to support the SPY System in its organ transplant surgery indication.
Ask a Question
K Number
K071619Device Name
SPY FLUORESCENT IMAGING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2007-11-09
(149 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY Fluorescent Imaging System is intended to provide fluorescent images for the visual assessment of blood flow in vessels and related tissue perfusion during cardiovascular surgical procedures.
Device Description
The Novadaq® Technologies SPY® Fluorescent Imaging System consists of 2 components:
- the SP2000 Imaging Device; and
- the SPY Paq®
The SPY Pag constitutes a 6 procedure kit. Each SPY Pag contains The Sir I aq constitution a o procours ... " procedures ... " leG and diluent to carry out 6 cardiovascular imaging procedures. Novadaq provides the ICG as it is sold by the manufacturer and does not adulterate the integrity of the original packaging or labeling. IC-Green™ (Akorn, Inc.) is packaged in an IC-Green kit that contains 6 x 25 mg vials of ICG along with 6 x 10 ml ampules of Aqueous Solvent.
The SP2000 Imaging Device consists of an imaging head containing a charge coupled device (CCD) camera, a laser light source, motion sensor and distance sensor attached via an articulating arm to a mobile cart. The mobile cart contains a flat panel display, computer, electronics enclosure and printer.
The SPY System provides the surgeon with the capability to view record and replay fluorescent images of blood flow in vessels and bypass grafts of the heart. A laser light source is used to illuminate the area of interest. ICG is injected intravenously through the central venous line, bypass pump, cardioplegia line and coronary graft and while it is passing through the vessels, the absorption of laser light causes excitation of the dye followed by emission of infrared energy. The result is a fluorescent image of blood flow and related tissue perfusion in the vessels. A CCD camera captures the image. These images are used to evaluate the integrity of the coronary vasculature and blood flow in the heart and bypass grafts.
Ask a Question
K Number
K072222Device Name
SPY FLUORESCENT IMAGING SYSTEM
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2007-09-07
(28 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SPY System is an imaging system used in capturing and viewing fluorescent images for the visual assessment of blood flow as an adjunctive method for the evaluation of tissue perfusion, and related tissuetransfer circulation in tissue and free flaps used in plastic, micro- and reconstructive surgical procedures.
Device Description
The Novadaq® Technologies SPY® Fluorescent Imaging System consists of 2 components: the SP2000 Imaging Device and the SPY Paq®. The SP2000 Imaging Device consists of an imaging head containing a charge coupled device (CCD) camera, a laser light source, motion sensor and distance sensor attached via an articulating arm to a mobile cart. The mobile cart contains a flat panel display, computer, electronics enclosure and printer. The SPY® System provides the surgeon with the capability to view record and replay fluorescent images of blood flow in vessels and bypass grafts of the heart. A laser light source is used to illuminate the area of interest. ICG is injected intravenously through the central or peripheral venous line, bypass pump, cardioplegia line and coronary graft and while it is passing through the vessels, the absorption of laser light causes excitation of the dye followed by emission of infrared energy. The result is a fluorescent image of blood flow and related tissue perfusion in the vessels. A CCD camera captures the image.
Ask a Question
K Number
K071037Device Name
SPY INTRA-OPERATIVE IMAGING SYSTEM, MODEL SP2000
Manufacturer
NOVADAQ TECHNOLOGIES, INC.
Date Cleared
2007-05-10
(28 days)
Product Code
IZI
Regulation Number
892.1600Why did this record match?
Applicant Name (Manufacturer) :
NOVADAQ TECHNOLOGIES, INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
For use in intraoperative visual assessment of the coronary vasculature and bypass grafts during coronary artery bypass (CABG) surgery.
Device Description
The SPY Imaging System: SP2000 is currently cleared for intraoperative visual assessment of the coronary vasculature and grafts during coronary artery bypass graft (CABG) surgery. The Novadaq Technologies SPY Intra-operative Imaging System consists of 2 components: the SPY Imaging Device; and the SPY Paq®
Ask a Question