Search Results
Found 3 results
510(k) Data Aggregation
K Number
K250239Device Name
NeuroMatch
Manufacturer
LVIS Corporation
Date Cleared
2025-05-23
(116 days)
Product Code
OLX, OLT, OMA, OMB
Regulation Number
882.1400Why did this record match?
Applicant Name (Manufacturer) :
LVIS Corporation
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
1. LVIS NeuroMatch Software is intended for the review, monitoring and analysis of electroencephalogram (EEG) recordings made by EEG devices using scalp electrodes and to aid neurologists in the assessment of EEG. The device is intended to be used by qualified medical practitioners who will exercise professional judgement in using the information.
2. The Seizure Detection component of LVIS NeuroMatch is intended to mark previously acquired sections of adult EEG recordings from patients greater than or equal to 18 years old that may correspond to electrographic seizures, in order to assist qualified medical practitioners in the assessment of EEG traces. EEG recordings should be obtained with a full scalp montage according to the electrodes from the International Standard 10-20 placement.
3. The Spike Detection component of LVIS NeuroMatch is intended to mark previously acquired sections of adult EEG recordings from patients ≥18 years old that may correspond to spikes, in order to assist qualified medical practitioners in the assessment of EEG traces. LVIS NeuroMatch Spike Detection performance has not been assessed for intracranial recordings.
4. LVIS NeuroMatch includes the calculation and display of a set of quantitative measures intended to monitor and analyze EEG waveforms. These include Artifact Strength, Asymmetry Spectrogram, Autocorrelation Spectrogram, and Fast Fourier Transform (FFT) Spectrogram. These quantitative EEG measures should always be interpreted in conjunction with review of the original EEG waveforms.
5. LVIS NeuroMatch displays physiological signals such as electrocardiogram (ECG/EKG) if it is provided in the EEG recording.
6. The aEEG functionality included in LVIS NeuroMatch is intended to monitor the state of the brain.
7. LVIS NeuroMatch Artifact Reduction (AR) is intended to reduce muscle and eye movements, in EEG signals from the International Standard 10-20 placement. AR does not remove the entire artifact signal and is not effective for other types of artifacts. AR may modify portions of waveforms representing cerebral activity. Waveforms must still be read by a qualified medical practitioner trained in recognizing artifacts, and any interpretation or diagnosis must be made with reference to the original waveforms.
8. LVIS NeuroMatch EEG source localization visualizes brain electrical activity on a 3D idealized head model. LVIS NeuroMatch source localization additionally calculates and displays summary trends based on source localization findings over time.
9. This device does not provide any diagnostic conclusion about the patient's condition to the user.
Device Description
NeuroMatch is a cloud-based software as a medical device (SaMD) intended to review, monitor, display, and analyze previously acquired and/or near real-time electroencephalogram (EEG) data from patients greater than or equal to 18 years old. The device is not intended to substitute for real-time monitoring of EEG. The software includes advanced algorithms that perform artifact reduction, seizure detection, and spike detection.
The subject device is identical to the NeuroMatch device cleared under K241390, with exception of the following additional features:
1. Source localization;
2. Source localization trends;
Source localization and source localization trends are substantially equivalent to the Epilog PreOp (K172858). Apart from the proposed additional software changes and associated changes to the Indications for Use and labeling there are no changes to the intended use or to the software features that were previously cleared. Below is a description of the software functions that will be added to the cleared NeuroMatch Device.
### 1. Source Localization
The NeuroMatch Source Localization visualization feature is used to visualize recorded EEG activity from the scalp in an idealized 3D model of the brain. The idealized brain model is based on template MR images. Each single sample of EEG-measured brain activity corresponds to a single point/pixel referred to as a source localization node (i.e., "node"). Together, the source localization nodes form a 3D cartesian grid where EEG signals with higher standardized current density are depicted in red and signals with lower standardized current density are depicted in blue. Source localization can be performed for any selected segment of the EEG data. The maximum and minimum of the source localization values are the absolute maximum and minimum values across the selected EEG signal, respectively. Users can also set an absolute threshold for the minimum value of the source localization outputs.
### 2. Source Localization Trends
NeuroMatch provides three automatic source localization trends to assist physicians investigating the amplitude and the frequency of the signal of interest (e.g. seizure onset) at the source space. Two of the trends provide simple 3D views of the sources of the high amplitude / high frequency across the signal of interest. The third trend provides a similar 3D view of the high frequency source movement across time.
- **Maximum Amplitude Projection (MAP):** This metric allows clinicians to readily determine which brain regions are active and have high amplitude source localization results. The metric is determined by iterating through each node within a specified analysis time window and outputting the maximum source localization amplitude at that node within the specified analysis time window. No value is reported for nodes which have not been identified as maximum at any time during the specified window. This metric can help show brain regions that have high amplitude during a seizure.
- **Node Visit Frequency (NVF):** This metric is reported as the number of times that a node has been labeled as maximum over time. This metric can help clinicians identify which brain regions are frequently active during a seizure.
- **Node Transition Frequency (NTF):** This metric allows clinicians to determine which brain regions are active in consecutive time frames over a selected time period. A node transition is defined as a transition from one maximum point to another over time, and the node transition frequency is calculated by iterating through all time points for a specified analysis window, counting the number of times a transition between two points occurs over that time, and then dividing it by the time window of analysis. This metric can help identify pairs of brain regions that are frequently active in sequential order.
Ask a Question
K Number
K241390Device Name
NeuroMatch
Manufacturer
LVIS Corporation
Date Cleared
2024-11-26
(195 days)
Product Code
OMB, OLT, OMA
Regulation Number
882.1400Why did this record match?
Applicant Name (Manufacturer) :
LVIS Corporation
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
1. LVIS NeuroMatch Software is intended for the review, monitoring and analysis of electroencephalogram (EEG) recordings made by EEG devices using scalp electrodes and to aid neurologists in the assessment of EEG. The device is intended to be used by qualified medical practitioners who will exercise professional judgement in using the information.
2. The Seizure Detection component of LVIS NeuroMatch is intended to mark previously acquired sections of adult EEG recordings from patients greater than or equal to 18 years old that may correspond to electrographic seizures, in order to assist qualified medical practitioners in the assessment of EEG traces. EEG recordings should be obtained with a full scalp montage according to the electrodes from the International Standard 10-20 placement.
3. The Spike Detection component of LVIS NeuroMatch is intended to mark previously acquired sections of adult EEG recordings from patients >18 years old that may correspond to spikes, in order to assist qualified medical practitioners in the assessment of EEG traces. LVIS NeuroMatch Spike Detection performance has not been assessed for intracranial recordings.
4. LVIS NeuroMatch includes the calculation and display of a set of quantitative measures intended to monitor and analyze EEG waveforms. These include Artifact Strength, Asymmetry Spectrogram, and Fast Fourier Transform (FFT) Spectrogram. These quantitative EEG measures should always be interpreted in conjunction with review of the original EEG waveforms.
5. LVIS NeuroMatch displays physiological signals such as electrocardiogram (ECG/EKG) if it is provided in the EEG recording.
6. The aEEG functionality included in LVIS NeuroMatch is intended to monitor the state of the brain.
7. LVIS NeuroMatch Artifact Reduction (AR) is intended to reduce muscle and eye movements, in EEG signals from the International Standard 10-20 placement. AR does not remove the entire artifact signal and is not effective for other types of artifacts. AR may modify portions of waveforms representing cerebral activity. Waveforms must still be read by a qualified medical practitioner trained in recognizing artifacts, and any interpretation or diagnosis must be made with reference to the original waveforms.
8. This device does not provide any diagnostic conclusion about the patient's condition to the user.
Device Description
NeuroMatch is a cloud-based software as a medical device (SaMD) intended to review, monitor, display, and analyze previously acquired and/or near real-time electroencephalogram (EEG) data from patients 18 years old or older. The device is not intended to substitute for real-time monitoring of EEG. The software includes advanced algorithms that perform artifact reduction, seizure detection, and spike detection.
Ask a Question
K Number
K222450Device Name
LVIS NeuroMatch
Manufacturer
LVIS Corporation
Date Cleared
2023-06-09
(298 days)
Product Code
OMB, OLT, OLX, OMA
Regulation Number
882.1400Why did this record match?
Applicant Name (Manufacturer) :
LVIS Corporation
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
1. LVIS NeuroMatch Software is intended for the review, monitoring and analysis of electroencephalogram (EEG) recordings made by EEG devices using scalp electrodes and to aid neurologists in the assessment of EEG. The device is intended to be used by qualified medical practitioners who will exercise professional judgement in using the information. 2. LVIS NeuroMatch includes the calculation and display of a set of quantitative measures intended to monitor and analyze EEG waveforms. These include Artifact Strength, Asymmetry Spectrogram, Autocorrelation Spectrogram, and Fast Fourier Transform (FFT) Spectrogram. These quantitative EEG measures should always be interpreted in conjunction with review of the original EEG waveforms.
3. LVIS NeuroMatch displays physiological signals such as electrocardiogram (ECG/EKC) if it is provided in the EEG recording.
4. The aEEG functionality included in LVIS NeuroMatch is intended to monitor the state of the brain.
5. LVIS NeuroMatch Artifact Reduction (AR) is intended to reduce muscle and eye movements in EEG signals from the International Standard 10-20 placement. AR does not remove the entifact signal and is not effective for other types of artifacts. AR may modify portions of waveforms representing cerebral activity. Waveforms must still be read by a qualified medical practitioner trained in recognizing artifacts, and any interpretation or diagnosis must be made with reference to the original waveforms.
6. This device does not provide any diagnostic conclusion about the patient's condition to the user.
Device Description
Not Found
Ask a Question
Page 1 of 1