Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K193033
    Device Name
    GSI Audera Pro
    Manufacturer
    Grason Stadler
    Date Cleared
    2020-04-24

    (176 days)

    Product Code
    GWJ, ETN, GWE, GWF
    Regulation Number
    882.1900
    Why did this record match?
    Applicant Name (Manufacturer) :

    Grason Stadler

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Audera Pro is intended to be used for the stimulation, recording and measurement of auditory evoked potentials, vestibular evoked myogenic potentials, auditory steady state responses and otoacoustic emissions. The device is indicated for use in the evaluation, identification, documentation and diagnosis of auditory and vestibular disorders. The device is intended to be used on patients of any age. The Audera Pro is intended to be used by qualified medical personnel such as an audiologist, physician, hearing healthcare professional, or trained technician. The Audera Pro is intended to be used in a hospital, clinic, or other healthcare facility with a suitable quiet testing environment. The anatomical sites of contact for auditory evoked potential (AEP) testing are the patient's ear canal (with the contact object being a sound delivery eartip or headphone, or an ear probe and eartip) and the patient's scalp and possibly other body sites (with the contact object being a bone transducer or electrodes that are capable of measuring bio-potentials). The anatomical sites of contact for vestibular evoked myogenic potential (VEMP) testing are the patient's ear canal (with the contact object being a sound delivery eartip or headphone, or an ear probe and eartip) and the patient's head and neck and possibly other body sites (with the contact object being a bone transducer or electrodes that are capable of measuring bio-potentials). The anatomical sites of contact for otoacoustic emission (DPOAE, TEOAE) testing are the patient's ear canal (with the contact object being an ear probe and eartip).
    Device Description
    The device is a configurable platform used to aid in the screening and diagnosis of sensory-neural and hearing conditions. It is capable of performing the following procedures: Auditory Evoked Potentials (EP), Auditory Steady-State Response (ASSR), Distortion Products Otoacoustic Emissions (DPOAE), Transient Evoked Otoacoustic Emissions (TEOAE), and vestibular evoked myogenic potentials (VEMP). The device system consists of a laptop PC with Windows 10 Pro, placed on top of or beside a specialized hardware implementation interface (i.e. platform) for the procedures. Software in the laptop controls the specialized hardware and collects and analyzes the resulting signals. Transducers and various accessories connect to the specialized hardware via connectors on the back of the hardware package.
    Ask a Question

    Page 1 of 1