K Number
K242664Device Name
gentleheel® Adult Incision Device
Manufacturer
Date Cleared
2024-11-05
(62 days)
Product Code
Regulation Number
878.4850Why did this record match?
Applicant Name (Manufacturer) :
GRI-Alleset, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
Intended Use
The gentleheel® Adult Incision Device is a single-use lancing device intended to obtain microliter capillary blood samples. The gentleheel® Adult Incision Device has a sharps prevention feature to protect the user from a needlestick injury.
Device Description
The gentleheel® Adult Incision Device is designed to be an easy to use, safe, one handed incision device for acquiring blood samples from the patient's finger to obtain sufficient blood volumes for capillary blood draws. The gentleheel Adult Incision Device utilizes a blade resulting in improved blood flow requirements. The welded plastic housing is designed to prevent accidental exposure to the blade, to be ergonomic for improved handling, and compatible with a human fingertip. The user is instructed to remove the trigger lock. When the gentleheel Adult Incision Device is placed against the patient's finger and the user presses the trigger mechanism it automatically makes the incision the blade in a continuous motion from inside the housing, into the fingertip, and then back within the housing. The trigger mechanism is no longer functional and the blade remains inside the housing through disposal. The entire device is discarded in a sharps container after use. The gentleheel Adult Incision Devices are provided sterile and are single patient use only. They are sterilized by Ethylene Oxide (EO) sterilization method.
Ask a Question
Ask a specific question about this device
K Number
K220917Device Name
gentleheel Micro-Preemie, gentleheel Preemie, gentleheel Newborn, gentleheel Toddler
Manufacturer
Date Cleared
2022-05-18
(49 days)
Product Code
Regulation Number
878.4850Why did this record match?
Applicant Name (Manufacturer) :
GRI-Alleset, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
Intended Use
The intended use of this device is for newborn babies of any ethnicity where a blood sample is desired, and a self-retracting safety feature is desired to protect the clinician performing the blood sampling.
Device Description
The gentleheel® is designed to be an easy to use, safe, one handed heel incision device for acquiring blood samples from the heels of newborns. The welded plastic housing is designed to prevent accidental exposure to the blade, to be ergonomic for improved handling, and compatible with an infant's foot. The user is instructed to remove the trigger lock. When the gentleheel is placed against the infant's heel and the user presses the trigger mechanism it automatically makes the incision by starting the blade in a continuous motion from inside the housing, into the infant's heel, and then back within the housing. The trigger mechanism is no longer functional and the blade remains inside the housing through disposal. The entire device is discarded in a sharps container after use. The gentleheel devices are provided sterile and are single patient use only. They are sterilized by Ethylene Oxide (EO) sterilization method.
The gentleheel comes in models for Newborn (NGH), Preemie (PGH), Micro-Preemie (MPGH), and Toddler (TGH). The models are differentiated by the styles and colors of the housing (see following definitions).
Ask a Question
Ask a specific question about this device
K Number
K210860Device Name
Comfort Guard Mask, level 1, Comfort Guard Mask, level 3
Manufacturer
Date Cleared
2022-04-07
(380 days)
Product Code
Regulation Number
878.4040Why did this record match?
Applicant Name (Manufacturer) :
GRI-Alleset, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
Intended Use
Non-sterile, single use device designed to create a physical barrier between the mouth and nose of the wearer and potential contaminants in the imment. They are designed to be worn in the operating room, dental offices, isolation and other medical procedures to protect both the patient and healthcare personnel from transfer of microogransims, bodily fluid and particulate matter.
Device Description
Not Found
Ask a Question
Ask a specific question about this device
K Number
K210131Device Name
ComfortGuard Surgical Isolation Gown
Manufacturer
Date Cleared
2021-08-26
(219 days)
Product Code
Regulation Number
878.4040Why did this record match?
Applicant Name (Manufacturer) :
GRI-Alleset, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
Intended Use
The GRI-Alleset ComfortGuard™ Surgical Isolation Gown is a non-sterile disposable, single-use gown intended to protect both the health care worker and patients from the transfer of microorganisms, bodily fluids and particulate matter in moderate risk patient isolations. This gown in not intended for use in an operating room environment and should not be worn during surgical or invasive procedures or when there is a potential for a high risk of contamination.
Additionally, the GRI-Alleset ComfortGuard™ Surgical Isolation Gown meets the requirements defined per ANSI/AAMI PB70:2012 Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for Use in Health Care Facilities (ANSI/AAMI PB70) for AAMI Level 3 barrier protection.
Device Description
Not Found