510(k) Data Aggregation

    K Number
    K033679
    Device Name
    COPSIOS BONE VOID FILLER (BVF)
    Manufacturer
    CENTERPULSE SPINE-TECH, INC.
    Date Cleared
    2004-07-07

    (226 days)

    Product Code
    MQV
    Regulation Number
    888.3045
    Why did this record match?
    Applicant Name (Manufacturer) :

    CENTERPULSE SPINE-TECH, INC.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    CopiOs™ BVF, in combination with autologous bone marrow, is intended for use only for filling bone voids or gaps of the skeletal system (ie, extremities, pelvis, spine) that are not intrinsic to the stability of the bone structure. These voids may be a result of trauma or creation by surgeon. CopiOs™ BVF is intended to be gently packed into the void or gap and will resorb during the course of the healing process.
    Device Description
    CopiOs™ BVF is a synthetic bone graft material consisting of mineralized, lyophilized collagen that has been formed into three-dimensional pads of various sizes for surgical implantation. The CopiOs™ BVF product sponge consists of dehydrothermally (DHT) cross-linked bovine dermal collagen mixed with calcium phosphate salt. The pads are approximately 67% mineral by weight. The fibrous collagen mixed with the calcium phosphate salt is cast into sponges as described in this application. The average porosity of the product was determined to be 93.39%, which allows for favorable conditions for cell migration and adherence to the collagenous matrix. Further, the calcium phosphate provides the mineral required for osteogenesis and the specific CopiOs™ BVF formulation provides a pH environment conducive for osteoinduction.
    Ask a Question
    K Number
    K031511
    Device Name
    DYNESYS SPINAL SYSTEM
    Manufacturer
    CENTERPULSE SPINE-TECH, INC.
    Date Cleared
    2004-03-05

    (296 days)

    Product Code
    NQP
    Regulation Number
    888.3070
    Why did this record match?
    Applicant Name (Manufacturer) :

    CENTERPULSE SPINE-TECH, INC.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    When used as a pedicle screw fixation system in skeletally mature patients, the DYNESYS Spinal System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, kyphosis, and failed previous fusion (pseudoarthrosis). In addition, when used as a pedicle screw fixation system, the DYNESYS Spinal System is indicated for use in patients: - Who are receiving fusions with autogenous graft only; a) - b) Who are having the device fixed or attached to the lumbar or sacral spine; and - c) Who are having the device removed after the development of a solid fusion mass.
    Device Description
    The DYNESYS® Spinal System consists of four pedicle screws, two cords and two spacers in a symmetric, bilateral arrangement. The pedicle screws are placed lateral to the facet joints with two screws in the cephalad position and two screws in the caudad position. The superior-inferior distance between the pedicle screws is maintained with the spacers. The cord passes through the eye of the pedicle screw heads and through the centers of the spacers.
    Ask a Question
    K Number
    K022615
    Device Name
    CENTERPULSE, SPINE-TECH DIVISION CEMENT RESTRICTOR
    Manufacturer
    CENTERPULSE SPINE-TECH, INC.
    Date Cleared
    2002-10-29

    (83 days)

    Product Code
    JDK
    Regulation Number
    878.3300
    Why did this record match?
    Applicant Name (Manufacturer) :

    CENTERPULSE SPINE-TECH, INC.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Spine-Tech™ Cement Restrictor is intended for use as a cement restrictor in orthopedic surgeries such as those involving the femoral canal and tibial plateau in hip stem and total knee replacement. The Spine-Tech™ Cement Restrictor is NOT intended for any spinal indications.
    Device Description
    The Spine-Tech™ Cement Restrictor is a threaded, hollow cylinder that is manufactured from PEEK Optima LT1 with carbon fiber. This device is intended to be used in conjunction with PMMA cement.
    Ask a Question
    K Number
    K022344
    Device Name
    TRINICA SELECT ANTERIOR CERVICAL PLATE SYSTEM
    Manufacturer
    CENTERPULSE SPINE-TECH, INC.
    Date Cleared
    2002-09-24

    (67 days)

    Product Code
    KWQ
    Regulation Number
    888.3060
    Why did this record match?
    Applicant Name (Manufacturer) :

    CENTERPULSE SPINE-TECH, INC.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Trinica Select™ Anterior Cervical Plate System is intended for anterior interbody screw fixation of the cervical spine at levels C2-T1. The System is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusions in patients with degenerative disc disease (as defined by neck pain of discogenic origin of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudoarthrosis, and/or failed previous fusions. WARNING: This device is not approved for screw attachment to the posterior elements (pedicles) of the cervical, thoracic, or lumbar spine.
    Device Description
    The Trinica Select Anterior Cervical Plate System is a fixation device consisting of cervical plates, locking caps, fixed bone screws and variable angle bone screws made from titanium alloy in conformance with ASTM F136. The locking cap is preassembled onto the plate and is designed with tabs that prevent bone screws from backing out. The plates and locking caps are treated with titanium anodization per AMS (Aerospace Material Specification) 2488 Type II. Bone screws are subjected to a color anodizing process to differentiate the screw type and diameter Plates are offered in one-level, two-level, and four-level fusion configurations (22 mm through 92 mm). Bone screws are available in lengths from 10mm through 18mm in 1mm increments. The screws have either a 4.2 inch 4.6 inch diameter. Fixed angle and variable angle screws are available.