510(k) Data Aggregation

    K Number
    K152870
    Device Name
    BD Veritor System for the Rapid Detection of Flu A + B CLIA waived kit
    Manufacturer
    BECTON DICKINSON AND CO.
    Date Cleared
    2015-10-27

    (27 days)

    Product Code
    PSZ, GNX
    Regulation Number
    866.3328
    Why did this record match?
    Applicant Name (Manufacturer) :

    BECTON DICKINSON AND CO.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The BD Veritor System for Rapid Detection of Flu A+B is a rapid chromatographic immunoassay for the direct and qualitative detection of influenza A and B viral nucleoprotein antigens from nasal and nasopharyngeal swabs of symptomatic patients. The BD Veritor System for Rapid Detection of Flu A+B (also referred to as the BD Veritor System and BD Veritor System Flu A+B) is a differentiated test, such that influenza A viral antigens can be distinguished from influenza B viral antigens from a single processed sample using a single device. The test is to be used as an aid in the diagnosis of influenza A and B viral infections. A negative test is presumptive and it is recommended that these results be confirmed by viral culture or an FDA-cleared influenza A and B molecular assay. Outside the U.S., a negative test is presumptive and it is recommended that these results be confirmed by viral culture or a molecular assay cleared for diagnostic use in the country of use. FDA has not cleared this device for use outside of the U.S. Negative test results do not preclude influenza viral infection and should not be used as the sole basis for treatment or other patient management decisions. The test is not intended to detect influenza C antigens.
    Device Description
    The BD Veritor™ Flu A+B test is an immunochromatographic assay for the qualitative detection of influenza A and B viral antigens in respiratory specimens. The patient specimen is mixed in a reaction tube prefilled with RV Reagent C, gently mixed, and then added to the test device. RV Reagent C contains mucolytic agents that function to break down mucus in a patient specimen thereby exposing viral antigens and enhancing detection in the assay device. Processed specimens are expressed through a filter tip into a single sample well on the BD Veritor™ Flu A+B test device. After addition to the test device, any influenza A or influenza B viral antigens present in the specimen bind to anti-influenza antibodies conjugated to detector particles on the Veritor™ Flu A+B test strip. The antigen-conjugate complexes migrate across the test strip to the reaction area and are captured by a line of antibody striped on the membrane. The Veritor™ Flu A+B test devices are designed with five spatially-distinct zones including positive and negative control line positions, separate test line positions for the target analytes, and a background zone. The test lines for the target analytes are labeled on the test device as 'A' for Flu A position, and 'B' for Flu B position. The onboard positive control ensures the sample has flowed correctly and is indicated on the test device as 'C'. Two of the five distinct zones on the test device are not labeled. These two zones are an onboard neqative control line and an assay background zone. The onboard negative control zone addresses non-specific signal generation. The remaining zone is used to measure the assay background. The BD Veritor™ Flu A+B assay incorporates an active negative control feature in each test to identify and compensate for sample-related, nonspecific signal generation. The BD Veritor™ System Reader uses a proprietary algorithm that subtracts nonspecific signal at the negative control line from the signal present at both the Flu A and Flu B test lines. If the resultant test line signal is above a pre-selected assay cutoff, the specimen scores as positive. If the resultant test line signal is below the cutoff, the specimen scores as negative. Use of the active negative control feature allows the BD Veritor™ System reader to correctly interpret test results that cannot be scored visually because the human eye is unable to accurately perform the subtraction of the nonspecific signal.
    Ask a Question
    K Number
    K010890
    Device Name
    BD ULTRA-FINE II INSULIN SYRINGE-MINI NEEDLE, MODEL 30G * 3/16 (5MM)
    Manufacturer
    BECTON DICKINSON AND CO.
    Date Cleared
    2001-04-19

    (24 days)

    Product Code
    FMF
    Regulation Number
    880.5860
    Why did this record match?
    Applicant Name (Manufacturer) :

    BECTON DICKINSON AND CO.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Device Description
    Ask a Question
    K Number
    K010572
    Device Name
    BD VISIDRAPE OPHTHALMIC DRAPES; BD VISIFLEX INCISE DRAPE
    Manufacturer
    BECTON DICKINSON AND CO.
    Date Cleared
    2001-03-12

    (14 days)

    Product Code
    KKX
    Regulation Number
    878.4370
    Why did this record match?
    Applicant Name (Manufacturer) :

    BECTON DICKINSON AND CO.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Device Description
    Ask a Question