NGL · Test, Opiates, Over The Counter

Clinical Toxicology · 21 CFR 862.3650 · Class 2

Overview

Product CodeNGL
Device NameTest, Opiates, Over The Counter
Regulation21 CFR 862.3650
Device ClassClass 2
Review PanelClinical Toxicology
3rd-Party ReviewableYes

Identification

An opiate test system is a device intended to measure any of the addictive narcotic pain-relieving opiate drugs in blood, serum, urine, gastric contents, and saliva. An opiate is any natural or synthetic drug that has morphine-like pharmocological actions. The opiates include drugs such as morphine, morphine glucoronide, heroin, codeine, nalorphine, and meperedine. Measurements obtained by this device are used in the diagnosis and treatment of opiate use or overdose and in monitoring the levels of opiate administration to ensure appropriate therapy.

Classification Rationale

Class II (special controls). An opiate test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (e.g., programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Special Controls

*Classification.* Class II (special controls). An opiate test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (*e.g.,* programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Recent Cleared Devices (20 of 23)

Showing 20 most recent of 23 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253567Healgen Accurate Urine Drug Screen Dip Card; Healgen Accurate Home Urine Drug Test Dip CardHealgen Scientific,, LLCDec 23, 2025SESE
K250803Deepblue Multi-Drug Urine Test Cup; Deepblue Home Muti-Drug Urine Test CupAnhui Deepblue Medical Technological Co., Ltd.Apr 15, 2025SESE
K250067Dochek® Multi-Drug Urine Test Cup; Dochek® Multi-Drug Urine Test Cup ProGuangzhou Decheng Biotechnology Co., Ltd.Feb 20, 2025SESE
K242428Dochek® Fentanyl Urine Test Strip, Dochek® Fentanyl Urine Test Strip Plus, Dochek® Fentanyl Urine Test Card, Dochek® Fentanyl Urine Test Card Plus, Dochek® Fentanyl Urine Test Cup and Dochek® Fentanyl Urine Test Cup PlusGuangzhou Decheng Biotechnology Co., Ltd.Feb 6, 2025SESE
K243365Healgen Accurate Muti-Drug Urine Drug Screen Cup; Healgen Accurate Home Muti-Drug Urine Test CupHealgen Scientific,, LLCDec 17, 2024SESE
K243064ETERBIO Fentanyl/Norfentanyl Rapid Test (Colloidal Gold); ETERBIO Fentanyl/Norfentanyl Home TestEterbio, Inc.Nov 20, 2024SESE
K242802CLUNGENE Fentanyl Home Test Cassette; CLUNGENE Fentanyl Test CassetteHangzhou Clongene Biotech Co., Ltd.Nov 8, 2024SESE
K241869BioSieve™ Fentanyl FIA Home Test Kit; BioSieve™ Fentanyl FIA Pro Test Kit; BioSieve™ Toxismart ReaderVivachek Biotech (Hangzhou) Co., Ltd.Oct 4, 2024SESE
K241969Hightop® Home Use Fentanyl/Norfentanyl Urine Rapid Test Panel; Hightop® Fentanyl/Norfentanyl Urine Rapid Test PanelQingdao Hightop Biotech Co., Ltd.Aug 14, 2024SESE
K241741SAFElife™ Fentanyl Urine Home Test (Cassette); SAFElife™ Fentanyl (FTY) Urine Test Cassette; SAFElife™ T-Dip Fentanyl Urine Home Test (Dip Card); SAFElife™ T-Dip Fentanyl (FTY) Urine Test PanelGuangzhou Wondfo Biotech Co., Ltd.Jul 16, 2024SESE
K241100Rapid Urine Fentanyl (FYL) Test Strip; Rapid Urine Fentanyl (FYL) Test DipcardCo-Innovation Biotech Co., Ltd.May 22, 2024SESE
K240949Healgen® Accurate Fentanyl Rapid Test Cassette (Urine); Healgen® Accurate Rapid Fentanyl Test Cassette (Urine); Healgen® Accurate Fentanyl Rapid Test Dip Card (Urine); Healgen® Accurate Rapid Fentanyl Test Dip Card (Urine); Healgen® Accurate Fentanyl Rapid Test Strip (Urine); Healgen® Accurate Rapid Fentanyl Test Strip (Urine)Healgen Scientific,, LLCMay 13, 2024SESE
K240686Healgen Accurate Urine Drug Screen Dip Card; Healgen Accurate Home Urine Drug Test Dip CardHealgen Scientific,, LLCApr 12, 2024SESE
K240654SAFECARE Fentanyl Urine Test Cassette; SAFECARE FYL Urine Test CassetteSafecare Biotech (Hangzhou) Co., Ltd.Apr 10, 2024SESE
K240295InstaStrip Fentanyl Rapid Test (Urine); InstaStrip Fentanyl Dipstick Test (Urine)Instanosis, Inc.Mar 28, 2024SESE
K234006AllSource Drug Detector FenTest; AllSource Drug Detector Fentanyl TestAllsource Screening SolutionsMar 21, 2024SESE
K240351FaStep Fentanyl Rapid Test Device (Urine); FaStep Rapid Fentanyl Urine Test (Urine)Assure Tech., LLCMar 6, 2024SESE
K233417AllTest Fentanyl Urine Test CassetteHangzhou AllTest Biotech Co., Ltd.Oct 26, 2023SESE
K193480BIOEASY Multi-Drug Test CupShenzhen Bioeasy Biotechnology Co., Ltd.Jan 31, 2020SESE
K190412CLUNGENE Multi-Drug Test Dip Card, CLUNGENE Multi-Drug Test Easy CupHangzhou Clongene Biotech Co., Ltd.Mar 21, 2019SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...