FHS · Dialyzer, Single Coil

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFHS
Device NameDialyzer, Single Coil
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (12 of 12)

RecordDevice NameApplicantDecision DateDecision
K812811MICROCOIL 80 DIALYZERErika, Inc.Dec 3, 1981SESE
K811974MICROCOIL 150 DIALYZERErika, Inc.Sep 16, 1981SESE
K801634THE VITA 2 DISPOSABLE DIALYZERBellco Artifidial Organ Spec., Inc.Dec 17, 1980SESE
K800723MICRO-COIL 100 COIL DIALYZERErika, Inc.May 14, 1980SESE
K800174GAMBRO LUNDIA COIL DIALYZERGambro, Inc.Feb 13, 1980SESE
K790223DIALYZER, CD-800 COILTravenol Laboratories, S.A.Mar 26, 1979SESE
K781102DIALYZER, DISP., COIL, LUNDIAGambro, Inc.Oct 17, 1978SESE
K771349MODIFICATION TO KIDNEY DIALYZERErika, Inc.Aug 2, 1977SESE
K770735DIALYZER, COIL, CD, LSA, 5M1765Travenol Laboratories, S.A.May 10, 1977SESE
K761358COIL DIALYZER MODEL ALT 140Bentley Laboratories, Inc.Jan 10, 1977SESE
K760702ERI-FLO 900 DIALYZERErika, Inc.Nov 19, 1976SESE
K760374DIALYZER (MODEL 1850)Erika, Inc.Oct 27, 1976SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...