FDS · Gastroscope And Accessories, Flexible/Rigid

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeFDS
Device NameGastroscope And Accessories, Flexible/Rigid
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 74)

Showing 20 most recent of 74 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K250550FUJIFILM Endoscope Model EG-S100XT and VS-1000 Display UnitFujifilm CorporationFeb 17, 2026SESE
K253568Hood DH-084STR; Hood DH-094STR; Hood DH-104STR; Hood DH-114STR; Hood DH-124STR; Hood DH-134STRFujifilm CorporationFeb 6, 2026SESE
K251256PENTAX Medical Video Upper GI Scopes (EG Family) (EG Family); PENTAX Medical Video Colonoscopes (EC Family) (EC Family)Pentax of America, Inc.Dec 16, 2025SESE
K251041GripTract-GI™ Endoscopic Tissue Manipulator Upper GI Model GT-GS100Actuated Medical, Inc.Oct 31, 2025SESE
K251708EvoEndo Single-Use Endoscopy SystemEvoEndo, Inc.Oct 10, 2025SESE
K243388Disposable Distal CapMicro-Tech (Nanjing) Co., Ltd.Jun 27, 2025SESE
K250900EvoEndo Single-Use Endoscopy SystemEvoEndo, Inc.Jun 16, 2025SESE
K243512FUJIFILM Endoscope Model EG-840N; FUJIFILM Endoscope Model EG-840T; FUJIFILM Endoscope Model EG-840TPFujifilm CorporationJun 10, 2025SESE
K242635Endoscopic Distal Attachment (AF-D series)Alton (Shanghai) Medical Instruments Co., Ltd.May 30, 2025SESE
K250296Disposable Distal Attachment D-201 SeriesOlympus Medical Systems Corp.May 1, 2025SESE
K241213PENTAX Medical Video Upper GI Scope (EG27-i20c); PENTAX Medical Video Colonoscope (EC34-i20cL)Pentax of America, Inc.Dec 6, 2024SESE
K242779Hood (DH-083ST)Fujifilm CorporationOct 11, 2024SESE
K240142FUJIFILM Endoscope Model EG-840N; FUJIFILM Endoscope Model EG-840T; FUJIFILM Endoscope Model EG-840TPFujifilm CorporationSep 4, 2024SESE
K232997EVIS Exera III Gastrointestinal Videoscope GIF-1TH190Olympus Medical Systems CorporationJun 19, 2024SESE
K232919Ambu® aScope™ Gastro Large; Ambu® aBox™ 2Ambu A/SApr 5, 2024SESE
K232028Q Vision Sterile Single Use Adult Flexible Gastroscope (G-100); Q Base Reusable Base Unit (Q-100)Iq Endoscopes LimitedNov 17, 2023SESE
K232314Hood (DH-106STL, DH-116STL, DH-126STL, DH-096ST)FUJIFILM Healthcare Americas CorporationSep 1, 2023SESE
K221551FUJIFILM Endoscope Model EI-740D/SFujifilm CorporatonJan 27, 2023SESE
K213606EvoEndo Single-Use Endoscopy SystemEvoEndo, Inc.Feb 14, 2022SESE
K212382Ambu® aScope™ Gastro, Ambu® aBox™2Ambu A/SFeb 3, 2022SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...