FDA · Enteroscope And Accessories

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeFDA
Device NameEnteroscope And Accessories
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (19 of 19)

RecordDevice NameApplicantDecision DateDecision
K251204FUJIFILM Stiffening Wire Device (SW-2000)FUJIFILM Healthcare Americas CorporationSep 26, 2025SESE
K233321Double Balloon Endoscope EN-840T, Over-tube TS-1214CFUJIFILM Healthcare Americas CorporationJun 13, 2024SESE
K231323Ancora-SBAspero Medical, Inc.Aug 31, 2023SESE
K223295Endoscope Model EN-580T, Over-tube TS-1314B, Balloon BS-4, Tube Kit TY-500DFujifilm CorporatonJan 11, 2023SESE
K213195Balloon BS-3Fujifilm CorporationOct 29, 2021SESE
K191330Arc EnterocuffBoddingtons Plastics, Ltd.Jan 31, 2020SESE
K183032FUJIFILM Double Balloon Endoscope EI580BTFujifilm CorporationJun 24, 2019SESE
K183683FUJIFILM Double Balloon Endoscopes EN-580T, EC-450BI5, EN-450P5/20, and EN-450T5Fujifilm CorporationFeb 27, 2019SESE
K143556Fujifilm Double Balloon Endoscopes Models EN-530T and EN-580TFujifilm Medical Systems U.S.A, Inc.Aug 20, 2015SESE
K071254SMALL INTESTINAL VIDEOSCOPE SYSTEMOlympus Medical Systems CorporationMar 25, 2008SESE
K060923NAVIAID BGE DEVICE, MODEL 21-001Smart Medical Systems , Ltd.Aug 15, 2006SESE
K060235ENDO-EASE ENDOSCOPIC OVERTUBESpirus Medical, Inc.Aug 4, 2006SESE
K040048FUJINON DOUBLE BALLOON ENTEROSCOPY SYSTEMFujinon, Inc.Jun 7, 2004SESE
K031256XSIF-1TQ140A SMALL INTESTINAL VIDEOSCOPEOlympus Opto-Electronics Co., Ltd.Jul 23, 2003SESE
K993704GASTRO-INTESTINAL SYSTEM EN-410WMFujinon, Inc.Feb 11, 2000SESE
K904800SIF-SWOlympus Corp.Mar 27, 1991SESE
K840722ENTEROSCOPETrimedyne, Inc.Jun 7, 1984SESE
K841396TRANSFER TROLLEYSetma, Inc.May 7, 1984SESE
K810757I.V. ADMINISTRATION SETAmerican McgawApr 8, 1981SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...