FCX · Insufflator, Automatic Carbon-Dioxide For Endoscope
Gastroenterology, Urology · 21 CFR 876.1500 · Class 2
Overview
| Product Code | FCX |
|---|---|
| Device Name | Insufflator, Automatic Carbon-Dioxide For Endoscope |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
| Review Panel | Gastroenterology, Urology |
| 3rd-Party Reviewable | Yes |
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Classification Rationale
(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Recent Cleared Devices (20 of 24)
Showing 20 most recent of 24 cleared devices.
| Record | Device Name | Applicant | Decision Date | Decision |
|---|---|---|---|---|
| K240847 | MedicCO2LON (MedicCO2LON) | Ide Vision, Ltd. | Oct 30, 2024 | SESE |
| K230474 | EVA5 Insufflator | Palliare , Ltd. | Mar 24, 2023 | SESE |
| K202922 | END 200 Endoscopic Tubeset | Palliare , Ltd. | Jul 8, 2021 | SESE |
| K201096 | CO2mbiLED | Karl Storz Endoscopy America, Inc. | Jun 23, 2020 | SESE |
| K190985 | BAROnova Insufflation System, BAROnova Accessory Kit | Baronova, Inc. | May 14, 2019 | SESK |
| K180711 | FUJIFILM Endoscopic CO2 Regulator GW-100 | Fujifilm Corporation | May 25, 2018 | SESE |
| K162332 | Nexcore GI Insufflator | Nexcore Technology, LLC | Sep 29, 2016 | SESE |
| K133976 | FUJIFILM ENDOSCOPIC CO2 REGULATOR | Fujifilm Medical System U.S.A., Inc. | Sep 9, 2014 | SESE |
| K132192 | BRACCO DIAGNOSTICS INC. PROTOCO, L TOUCH COLON INSUFFLATOR | Bracco Diagnostic, Inc. | Feb 14, 2014 | SESE |
| K123047 | BRACCO DIAGNOSTICS INC. CO2 ENDOSCOPIC INSUFFLATOR IN LINE TUBING SET | Bracco Diagnostic, Inc. | Aug 6, 2013 | SESE |
| K113310 | ENDOGATER AVANTAGE CO2 INSUFFLATOR | Byrne Medical, Inc. | Jun 20, 2012 | SESE |
| K111648 | BRACCO DIAGNOSTICS, INC. CO2MPACT ENDODCOPIC INSUFFLATOR | Bracco Diagnostic, Inc. | Nov 3, 2011 | SESE |
| K090879 | INSUFLOW CO2IONSHIELD | Lexion Medical, LLC | Jul 23, 2009 | SESE |
| K063786 | ENDOSCOPIC INSUFFLATION UNIT, MODEL XECR-2 | Olympus Medical Systems Corporation | Mar 5, 2007 | SESE |
| K053008 | E-Z-EM ENDOSCOPIC CO2 REGULATOR | E-Z-Em, Inc. | Dec 27, 2005 | SESE |
| K030854 | PROTOCO2L COLON INSUFFLATOR WITH PERFORMANCE IMPROVEMENTS, MODEL 6400 | E-Z-Em, Inc. | Apr 16, 2003 | SESE |
| K013219 | PROTOCO2L INSUFFLATOR MODEL 6400 | E-Z-Em, Inc. | Feb 19, 2002 | SESE |
| K945970 | INSUFFLATOR FILTER TUBING SET | Xylog Corp. | Dec 15, 1994 | SESE |
| K930581 | E-Z-FLATE | E-Z-Em, Inc. | Jul 1, 1994 | SESE |
| K935059 | INSUFFLATION TUBING SET, PHX500-082 | Phx Technologies Corp. | Dec 22, 1993 | SESE |
Top Applicants
- E-Z-Em, Inc. — 4 clearances
- Bracco Diagnostic, Inc. — 3 clearances
- Palliare , Ltd. — 2 clearances
- Baronova, Inc. — 1 clearance
- Byrne Medical, Inc. — 1 clearance