DSL 1900 ACTIVE HUMAN GROWTH HORMONE IRMA (DSL 1900)
Device Facts
| Record ID | K970701 |
|---|---|
| Device Name | DSL 1900 ACTIVE HUMAN GROWTH HORMONE IRMA (DSL 1900) |
| Applicant | Diagnostic Systems Laboratories, Inc. |
| Product Code | CFL · Clinical Chemistry |
| Decision Date | Apr 2, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1370 |
| Device Class | Class 1 |
Indications for Use
The DSL hGH IRMA assay is intended for the quantitative determination of hGH in human serum. The measurement of hGH is used as a diagnostic aid in the evaluation of hGH deficiency disorders or acromegaly.
Device Story
DSL 1900 hGH IRMA kit; non-competitive immunoradiometric assay (IRMA) for quantitative hGH measurement in human serum. Analyte sandwiched between immobilized antibody (coated tube) and radiolabelled antibody; unbound material removed via decanting/washing. Gamma counter measures net counts; bound hGH concentration directly proportional to counts. Used in clinical laboratory settings by trained personnel. Results aid clinicians in evaluating hGH deficiency or acromegaly.
Clinical Evidence
Bench testing only. Comparative study of 68 human serum samples using subject IRMA kit and predicate ELISA. Linear regression analysis: Y = 0.93(predicate) - 0.19; r = 0.97.
Technological Characteristics
Non-competitive immunoradiometric assay (IRMA). Components: antibody-coated tubes, radiolabelled antibody. Detection via gamma counter. Quantitative measurement based on direct proportionality between bound hGH and net counts.
Indications for Use
Indicated for quantitative measurement of hGH in human serum to aid in diagnosis of hGH deficiency disorders or acromegaly.
Regulatory Classification
Identification
A human growth hormone test system is a device intended to measure the levels of human growth hormone in plasma. Human growth hormone measurements are used in the diagnosis and treatment of disorders involving the anterior lobe of the pituitary gland.
Predicate Devices
- DSL 10-1900 hGH ELISA
Related Devices
- K960551 — DSL ACTIVE HUMAN GROWTH HORMONE ELISA · Diagnostic Systems Laboratories, Inc. · Mar 6, 1996
- K961172 — DSL ACTIVE NON-EXTRACTION IGF-I IRMA · Diagnostic Systems Laboratories, Inc. · Apr 23, 1996
- K962118 — DSL ACTIVE FSH IRMA · Diagnostic Systems Laboratories, Inc. · Sep 9, 1996
- K971353 — DSL ACTIVE NON-EXTRACTION IGF-I ELISA · Diagnostic Systems Laboratories, Inc. · May 12, 1997
- K960357 — DSL ACTIVE I-HCG IRMA · Diagnostic Systems Laboratories, Inc. · May 7, 1996