(13 days)
Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:
Transducer S-VNW 5-10: Pediatric, small organs (including thyroid, testicles, salivary gland, breast, and lymph nodes); peripheral vascular; and musculoskeletal-conventional.
Transducer S-VAW 4-7: Fetal, abdominal, pediatrics, and small organs.
Transducer S-VNW 5-10 is a multielement, mechanically steered linear array (volume) probe for use with the Combison 530D Diagnostic Ultrasound System. The center frequency is 7.5 MHz, and the nominal transmit frequency range is 5 to 10 MHz. The scan width is 40 mm and the maximum depth range is 75 mm.
Transducer S-VAW 4-7 is a multielement curved array probe for use with the Combison 530D system. The center frequency is 4.5 MHz, and the nominal transmit frequency range is 4 to 7 MHz. The image starting width is approximately 70 mm and the maximum depth range is 200 mm.
Operating Modes: Both Transducer S-VNW 5-10 and Transducer S-VAW 4-7 operate in B-mode (including three-dimensional volume imaging), M-mode, Pulsed Doppler, and Color Flow modes.
The provided text describes two diagnostic ultrasound transducers, Model S-VNW 5-10 Voluson Small Parts Transducer and Model S-VAW 4-7 Voluson Abdominal Transducer, intended for use with the Combison 530D Diagnostic Ultrasound System. The submission is a 510(k) summary, which focuses on demonstrating substantial equivalence to predicate devices rather than providing detailed clinical study results or acceptance criteria in the typical sense of a diagnostic AI product.
Therefore, much of the requested information (like specific acceptance criteria values, sample sizes for test sets, data provenance, expert ground truth establishment, adjudication methods, MRMC studies, or training set details) is not applicable or not explicitly detailed in this type of regulatory submission for a hardware device like an ultrasound transducer.
Here's an attempt to answer the questions based only on the provided text, with clear indications where information is unavailable:
1. Table of Acceptance Criteria and Reported Device Performance:
The document states that "Measurement accuracy, precision of volume reconstruction, electrical and thermal safety, and software performance have been tested in accordance with applicable guidelines and standards with satisfactory results." However, specific numerical acceptance criteria (e.g., "accuracy > 90%") and their corresponding precise performance values are not provided. This level of detail is typically not included in a 510(k) summary for a transducer.
| Acceptance Criteria Category | Reported Device Performance |
|---|---|
| Measurement Accuracy | Satisfactory |
| Precision of Volume Reconstruction | Satisfactory |
| Electrical Safety | Satisfactory |
| Thermal Safety | Satisfactory |
| Software Performance | Satisfactory |
| Acoustic Output | Measured as specified in pertinent FDA recognized standards and reported according to Track 3. (A specific numerical output is not given, but compliance with standards is implied.) |
2. Sample size used for the test set and the data provenance:
- Sample Size for Test Set: Not specified. The document mentions testing was done, but no details on the number of cases or subjects are provided.
- Data Provenance (e.g., country of origin of the data, retrospective or prospective): Not specified.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Number of Experts: Not applicable/Not specified. This pertains to clinical performance evaluation, which is not detailed for this hardware submission. The "ground truth" for a transducer primarily relates to its physical performance characteristics (e.g., accuracy of measurements, safety parameters) rather than diagnostic interpretations requiring human experts to establish ground truth in a clinical sense.
- Qualifications of Experts: Not applicable/Not specified.
4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Adjudication Method: Not applicable/Not specified. This is relevant for clinical performance studies involving human interpretation or consensus, which is not detailed here.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- MRMC Comparative Effectiveness Study: No. This is a submission for an ultrasound transducer, not an AI-based diagnostic tool. Therefore, an MRMC study comparing human readers with and without AI assistance is not relevant or mentioned.
6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
- Standalone Performance Study: Not applicable/No. This device is a diagnostic ultrasound transducer, a hardware component that requires human operation and interpretation. It is not an algorithm that performs in a standalone manner. The performance of the transducer (e.g., image quality, measurement accuracy) is what's being assessed, always in the context of human use.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- Type of Ground Truth: The "ground truth" for the tests mentioned (measurement accuracy, precision of volume reconstruction, electrical/thermal safety, software performance, acoustic output) would typically refer to validated engineering measurements against known physical standards, phantom studies, and adherence to regulatory safety limits and technical specifications. It is not clinical "ground truth" derived from pathology or expert consensus on patient cases.
8. The sample size for the training set:
- Sample Size for Training Set: Not applicable/Not specified. This device is a hardware component. The concept of a "training set" is generally associated with machine learning models, which are not detailed as part of this submission. Device design and validation rely on engineering principles and testing against specifications, not machine learning training.
9. How the ground truth for the training set was established:
- How Ground Truth for Training Set was Established: Not applicable/Not specified. See the explanation for point 8.
{0}------------------------------------------------
510(k) SUMMARY
K 992155
MODEL S-VNW 5-10 VOLUSON® SMALL PARTS TRANSDUCER MODEL S-VAW 4-7 VOLUSON® ABDOMINAL TRANSDUCER
-
- COMPANY INFORMATION. Name: Medison America, Inc. Address: 6616 Owens Drive, Pleasanton, CA 94588. Phone: (925) 463-1830. Contact: Bob Leiker - Vice President, Regulatory and Quality. Manufacturer: Kretztechnik AG, Tiefenbach 15, A-4871, Zipf, Austria.
-
- DEVICE IDENTIFICATION. Trade Name: (1) Model S-VNW 5-10 Voluson® Small Parts Transducer (2) Model S-VAW 4-7 Voluson® Abdominal Transducer. Common Name: Diagnostic Ultrasound Transducer. Classification Name: Diagnostic Ultrasound Transducer, 90-1TX.
-
- PREDICATE DEVICE. For Model S-VNW 5-10: Kretztechnik Transducer Model S-NLM 5-10. For Model S-VAW 4-7: Kretztechnik Transducer Models S-VSW 3-5 and S-ACA 4-7. The three predicate devices were all cleared with the Combison 530D system under 510(k)'s K940942 and K974813. See also Combison 530D Special Report dated October 23, 1997.
-
- DEVICE DESCRIPTION. General: Transducer S-VNW 5-10 is a multielement, mechanically steered linear array (volume) probe for use with the Combison 530D Diagnostic Ultrasound System. The center frequency is 7.5 MHz, and the nominal transmit frequency range is 5 to 10 MHz. The scan width is 40 mm and the maximum depth range is 75 mm. Transducer S-VAW 4-7 is a multielement curved array probe for use with the Combison 530D system. The center frequency is 4.5 MHz, and the nominal transmit frequency range is 4 to 7 MHz. The image starting width is approximately 70 mm and the maximum depth range is 200 mm. Operating Modes: Both Transducer S-VNW 5-10 and Transducer S-VAW 4-7 operate in B-mode (including three-dimensional volume imaging), M-mode, Pulsed Doppler, and Color Flow modes.
-
- INTENDED USES. Transducer S-VNW 5-10: Pediatric, small organs (including thyroid, testicles, salivary gland, breast, and lymph nodes); peripheral vascular; and musculoskeletal-conventional. Transducer S-VAW 4-7: Fetal, abdominal, pediatrics, and small organs.
-
- COMPARISON WITH PREDICATE DEVICE. Transducer S-VNW 5-10: This device is a modification of its predicate device. The major difference is that the modified transducer contains 192 elements while the predicate device has 128. Transducer S-VAW 4-7: This device is a combination of its two predicate devices. The principle difference is that the subject device is a curved array while one of the two predicate devices was an annular array. Evaluation: Transducers S-VNW 5-10 and S-VAW 4-7 are both similar in design and function to their respective predicate devices. Neither transducer introduces new modes of operation or indications for use beyond those previously cleared.
-
- PERFORMANCE DATA. Measurement accuracy, precision of volume reconstruction, electrical and thermal safety, and software performance have been tested in accordance with applicable guidelines and standards with satisfactory results. Patient contact materials remain unchanged. Acoustic output has been measured as specified in pertinent FDA recognized standards and is reported according to Track 3.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white logo for the Department of Health & Human Services - USA. The logo features a stylized image of an eagle with three human profiles incorporated into its design. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle image.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUL -8 1999
Medison America, Inc. C/O Carole Stamp TUV product Services 1775 Old Highway 8 New Brighton, MN 55112-1891
RE: K992155 Model S-VNW 5-10 Voluson Small parts Transducer Model S-VAW 4-7 Voluson Abdominal Transducer Dated: June 24, 1999 Received: June 25, 1999 Regulatory Class: II 21 CFR 892.1570/Procode: 90 ITX
Dear Ms. Stamp:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
This determination of substantial equivalence applies to the following transducers intended for use with the Combison 530D Diagnostic Ultrasound System as described in your premarket notification:
Transducer Model Number(s):
Model S-VNW 5-10 Voluson Small Parts Model S-VAW 4-7 Voluson Abdominal
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic QS inspections, the FDA will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification does not affect any obligation you may have under sections 531 and 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{2}------------------------------------------------
Page -2 - Ms. Stamp
This determination of substantial equivalence is granted on the condition that prior to shipping the first device, you submit a postclearance special report. This report should contain complete information, including acoustic output measurements based on production line devices, requested in Appendix G, (enclosed) of the Center's September 30, 1997 "Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers." If the special report is incomplete or contains unacceptable values (e.g., acoustic output greater than approved levels), then the 510(k) clearance may not apply to the production units which as a result may be considered adulterated or misbranded.
The special report should reference the manufacturer's 510(k) number. It should be clearly and prominently marked "ADD-TO-FILE" and should be submitted in duplicate to:
Food and Drug Administration Center for Devices and Radiological Health Document Mail Center (HFZ-401) 9200 Corporate Boulevard Rockville, Maryland 20850
This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4591. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
If you have any questions regarding the content of this letter, please contact Robert Phillips, Ph.D at (301) 594-1212.
Sincerely yours,
CAPT Daniel Schultz, M.D.
CAPT Daniel Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
{3}------------------------------------------------
.
Ultrasound Device Indications Statement
| 510(k) Number: | |
|---|---|
| Device Name: | Voluson C530D Ultrasound System |
| Transducer: | S-VNW 5-10 Small Part Volume Transducer |
| Indications for Use: | Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: |
Mode of Operation (*includes simultaneous B-mode)
| Mode of Operation (* includes simultaneous B-mode) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Clinical Applications | A | B | M* | PWD* | CWD* | ColorDoppler* | Power(Amplitude)Doppler * | ColorVelocityImaging | Combined(Specify)*See Note 1 | Other(Specify)See Note 2 |
| Ophthalmic | ||||||||||
| Fetal | ||||||||||
| Abdominal | ||||||||||
| Intraoperative:(Specify) | ||||||||||
| IntraoperativeNeurological | ||||||||||
| Pediatric | E | E | E | E | E | E | E | E | N | |
| Small Organ(Specify) See Note 3 | E | E | E | E | E | E | E | E | N | |
| Neonatal Cephalic | ||||||||||
| Adult Cephalic | ||||||||||
| Cardiac | ||||||||||
| Transesophageal | ||||||||||
| Transrectal | ||||||||||
| Transvaginal | ||||||||||
| Transurethral | ||||||||||
| Intravascular | ||||||||||
| Peripheral vascular | E | E | E | E | E | E | E | E | N | |
| Laparoscopic | ||||||||||
| Musculo-skeletalConventional | E | E | E | E | E | E | E | E | N | |
| Musculo-skeletal Superficial | ||||||||||
| Other (Specify) |
N = new indication; P = Previously cleared in K940942, Voluson C530D Ultrasound System; P = Previously cleared in K974813, Voluson C530D Ultrasound System with Power Doppler; E = added under Appendix E
Other Indications or Modes:
Note 1: PWD/Color Doppler, PWD/Power Doppler.
Note 2: 3D Volume Imaging Mode
Note 3: For example: thyroid, testicles, salivary gland, breast, lymph nodes, and pediatric patients.
| Concurrence of CDRH, Office of Device Evaluation (ODE) | |
|---|---|
| Prescription Use (Per 21 CFR 801.109) |
| (Division Sign-Off) | |
|---|---|
| Division of Reproductive, Abdominal, ENT, | |
| and Radiological Devices |
| Prescription Use | |
|---|---|
| (Per 21 CFR 801.109) | |
| 510(k) Number | K992155 |
{4}------------------------------------------------
Ultrasound Device Indications Statement
| 510(k) Number: | Voluson C530D Ultrasound System |
|---|---|
| Device Name: | |
| Transducer: | S-VAW 4-7 Abdominal Volume Transducer |
| Indications for Use: | Diagnostic ultrasound imaging or fluid flow analysis of the human body |
as follows:
Mode of Operation (*includes simultaneous B-mode)
| Clinical Applications | A | B | M* | PWD* | CWD* | ColorDoppler* | Power(Amplitude)Doppler * | ColorVelocityImaging | Combined(Specify)*See Note 1 | Other(Specify)See Note 2 |
|---|---|---|---|---|---|---|---|---|---|---|
| Ophthalmic | ||||||||||
| Fetal | P | P | P | P | P¹ | P | ||||
| Abdominal | P | P | P | P | P¹ | P | ||||
| Intraoperative: | ||||||||||
| (Specify) | ||||||||||
| Intraoperative | ||||||||||
| Neurological | ||||||||||
| Pediatric | P | P | P | P | P¹ | P | ||||
| Small Organ | P | P | P | P | P¹ | P | ||||
| (Specify) See Note 3 | ||||||||||
| Neonatal Cephalic | ||||||||||
| Adult Cephalic | ||||||||||
| Cardiac | ||||||||||
| Transesophageal | ||||||||||
| Transrectal | ||||||||||
| Transvaginal | ||||||||||
| Transurethral | ||||||||||
| Intravascular | ||||||||||
| Peripheral vascular | ||||||||||
| Laparoscopic | ||||||||||
| Musculo-skeletalConventional | ||||||||||
| Musculo-skeletal Superficial | ||||||||||
| Other (Specify) |
N = new indication; P = Previously cleared in K940942, Voluson C530D Ultrasound System; P = Previously cleared in K974813, Voluson C530D Ultrasound System with Power Doppler; E = added under Appendix E
Other Indications or Modes:
Note 1: PWD/Color Doppler, PWD/Power Doppler.
Note 2: 3D Volume Imaging Mode
Note 3: For example: thyroid, testicles, salivary gland, breast, lymph nodes, and pediatric patients.
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
| (Division Sign-Off)Division of Reproductive, Abdominal, ENT,and Radiological Devices | |
|---|---|
| 510(k) Number | K992155 |
Prescription Use
§ 892.1570 Diagnostic ultrasonic transducer.
(a)
Identification. A diagnostic ultrasonic transducer is a device made of a piezoelectric material that converts electrical signals into acoustic signals and acoustic signals into electrical signals and intended for use in diagnostic ultrasonic medical devices. Accessories of this generic type of device may include transmission media for acoustically coupling the transducer to the body surface, such as acoustic gel, paste, or a flexible fluid container.(b)
Classification. Class II.