(72 days)
The 2600 endoscope is intended for accessing and visualizing the spinal nerve root, foramina, intervertebral disc, and the surrounding tissues of the lumbar spine. The endoscope has a working channel intended for the passage of surgical instruments indicated for use in this area. Surgical instrumentation may be used for discectomy procedures, bone and osteophyte removal, procedures associated with ruptured or herniated discs such as, retrieval of extruded disc fragments and retrieval of free fragments. The Model 2600 also has an irrigation channel for sterile fluid flush or aspiration.
The Model 2600 Neuro Endoscope is manufactured using medical grade biocompatible materials. The basic design and materials are the same as those used in the Model 1103 Laser Endoscopic Disc Decompression Kit, the Model 2230 Neuro Endoscope, and the Model 2125 Endoscopic Ball Probe. Further, the sizes and configurations of the endoscope and accessories are equivalent as well.
The Model 2600 Neuro Endoscope is a rigid fiber optic endoscope with a molded proximal handle. The optical element of the endoscope consists of a fiber optic image bundle with a distal lens and a fiber light guide. The endoscope has a working channel and a separate fluid irrigation channel.
The light and image guides are terminated with standard connectors designed to interface with light cables and video cameras. The fluid irrigation channel is terminated with a standard Luer-Lok connector. The working channel has a proximal port to allow the passage of surgical instruments.
This 510(k) summary for the Clarus Model 2600 Neuro Endoscope does not contain the detailed information necessary to fully answer the request. The document describes a traditional medical device (an endoscope) and its testing, which focuses on biocompatibility and physical performance, rather than algorithm performance.
Therefore, many sections of your request related to AI/algorithm performance (e.g., acceptance criteria for diagnostic performance, sample sizes for test/training sets, expert ground truth, MRMC studies, standalone performance) are not applicable or cannot be extracted from this document.
Here's an analysis based on the provided text:
1. Table of acceptance criteria and the reported device performance
| Acceptance Criteria | Reported Device Performance |
|---|---|
| Biocompatibility | All materials passed Biocompatibility testing and are suitable for this application. |
| Physical Testing | All testing of the product yielded acceptable results. |
| Dimensional inspection | Acceptable results |
| Weld strength testing | Acceptable results |
| Optical clarity | Acceptable results |
| Light transmittance | Acceptable results |
| Fluid flow rate | Acceptable results |
Note: The document states "All testing of the product yielded acceptable results" for physical testing, implying these were the acceptance criteria. Specific numerical acceptance thresholds are not provided.
2. Sample size used for the test set and the data provenance
- Sample size: Not specified. The testing described is for the physical and biological properties of the device itself (materials, construction), not for diagnostic performance using a test set of data/images.
- Data provenance: Not applicable in the context of diagnostic performance data. The tests are performed on the device components/product samples.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
- Not applicable. This device is a surgical endoscope, not an AI/diagnostic algorithm. Its performance is assessed through engineering and biocompatibility tests, not by comparing its diagnostic output to expert-established ground truth on a dataset.
4. Adjudication method for the test set
- Not applicable. See point 3.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance
- No. This is not an AI-powered diagnostic device. No MRMC study was conducted or is relevant for this type of product.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- No. This is not an algorithm.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
- Not applicable in the context of diagnostic performance. For biocompatibility, "ground truth" is established by relevant ISO standards and test methods. For physical testing, "ground truth" is established by design specifications and engineering standards.
8. The sample size for the training set
- Not applicable. This device does not involve a training set as it is not an AI/machine learning algorithm.
9. How the ground truth for the training set was established
- Not applicable. See point 8.
Summary regarding AI/Algorithm specific questions:
The provided 510(k) summary describes a standard medical device (a neuro endoscope) and its physical and biocompatibility testing. It predates widespread clinical AI applications (filed in 1997, cleared in 1998). Therefore, the questions related to AI/algorithm performance (test sets, training sets, ground truth for data, expert adjudication, MRMC studies) are not relevant to this submission and cannot be answered from the text. The "testing" section refers to manufacturing quality control and material safety, not diagnostic performance of an algorithm.
{0}------------------------------------------------
510K Summary
FEB 118 1998
Clarus Model 2600 Neuro Endoscope
6974579
General Information
| Classification | Class II |
|---|---|
| Trade Name | PercScope™ |
| Submitter | Clarus Medical Systems, Inc.1000 Boone Avenue North, Suite 100Golden Valley, Minnesota 55427 |
| Contact | Dale SappenfieldVP, Operations(612) 525-8400 |
Predicate Devices
- Clarus Model 2230 Neuro Endoscope by Clarus Medical .
- Model 1103 Laser Endoscopic Disc Decompression Kit by Clarus Medical .
- . Model 2125 Endoscopic Ball Probe by Clarus Medical
Device Description
The Model 2600 Neuro Endoscope is manufactured using medical grade biocompatible materials. The basic design and materials are the same as those used in the Model 1103 Laser Endoscopic Disc Decompression Kit, the Model 2230 Neuro Endoscope, and the Model 2125 Endoscopic Ball Probe. Further, the sizes and configurations of the endoscope and accessories are equivalent as well.
The Model 2600 Neuro Endoscope is a rigid fiber optic endoscope with a molded proximal handle. The optical element of the endoscope consists of a fiber optic image bundle with a distal lens and a fiber light guide. The endoscope has a working channel and a separate fluid irrigation channel.
{1}------------------------------------------------
The light and image guides are terminated with standard connectors designed to interface with light cables and video cameras. The fluid irrigation channel is terminated with a standard Luer-Lok connector. The working channel has a proximal port to allow the passage of surgical instruments.
Intended Use
The 2600 endoscope is intended for accessing and visualizing the spinal nerve root, foramina, intervertebral disc, and the surrounding tissues of the lumbar spine. The endoscope has a working channel intended for the passage of surgical instruments indicated for use in this area. Surgical instrumentation may be used for discectomy procedures, bone and osteophyte removal, procedures associated with ruptured or herniated discs such as, retrieval of extruded disc fragments and retrieval of free fragments. The Model 2600 also has an irrigation channel for sterile fluid flush or aspiration.
Testing
Biocompatibility testing was performed on the materials used in the construction of these endoscopes. All materials passed Biocompatibility testing and are suitable for this application.
Physical testing of the product will include: dimensional inspection, weld strength testing, optical clarity, light transmittance and fluid flow rate. All testing of the product yielded acceptable results.
Summary of Substantial Equivalence
The Clarus Model 2600 Neuro Endoscopes are constructed of the same material as the Series 2200 Endoscopes, the Model 2230 Endoscopes, and Model 1103 Laser Endoscopic Disc Decompression Kit as well as other Clarus products. The sizes and configuration available along with the packaging and sterilization methods are also equivalent.
The clinical indications for use are equivalent to those for Model 2230.
Therefore, due to the similarity of materials to other Clarus devices, the test results and the equivalent indication for use to other predicate devices, Clarus believes these products do not raise any new safety or effectiveness issues.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged in a circular fashion around the symbol. The caduceus is rendered in black, and the text is also in black.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
FEB 1 8 1998
Mr. Dale Sappenfield Vice President Operations Clarus Medical Systems, Incorporated 1000 Boone Avenue North, Suite 100 Golden Valley, Minnesota 55427
Re: K974579 Trade Name: PercScope™ Model 2600 Regulatory Class: II Product Code: HRX Dated: December 3, 1997 Received: December 8, 1997
Dear Mr. Sappenfield:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements , as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for
{3}------------------------------------------------
Page 2 - Mr. Sappenfield
devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Jcsellyz
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Device Name: PercScope Model 2600
lications For Use:
III. Device Description Information
Intended Use
The 2600 endoscope is intended for accessing and visualizing the spinal nervertebral disc, and the surrounding tissues of the lumbar spine. The endoscope has a working channel intended for the passage of surgical instruments indicated for use in this area. Surgical instrumentation may be used for discessory procedures, bone, and osteophyte removal, procedures associated with ruptured or herniated discs such as, retrieval of extruded disc fragments. The Model 2600 also has as irrigation channel for sterile fluid flush or aspiration.
The Model 2600 Neuro Endoscope is a modification of the current Model 2230 Neuro Endoscope filled under K941 188. The Model 2600 incomorates similar materials and design of the Model 2230 and the original Series 2200 Semi-rigid Endoscopes, as filed under K924554 which are manufactured of stainless steel with polycarbonate proximal handles.
Access to the nerve root area may be gained either during an open operative procedure or percutaneously. Access during an open procedure would be the same as with the Clarus Endoscopic Ball Probe filed as K922281. The perculaneous access procedure is identical to the disc access procedure used for the Model 2230. The instrumentation and technique are identical.
The Model 2600 Neuro Endoscope is packaged separately or with an accessory kit for percutaneous introduction, which includes a spinal needle, introducer cannula, and ditional kit of disposable accessories will be sold which includes the following:
- Introducer septum
- PercScope septum
- Flush tubing
- Scalpel
- Marking pen
- Plastic ruler
These accessory items are the same as identified in the Model 2230, K941188.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
biceef
(Division Sign-Off)
Division of General Restorative Devices K974579
510(k) Number
==============================================================================================================================================================================
§ 888.1100 Arthroscope.
(a)
Identification. An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.(b)
Classification. (1) Class II (performance standards).(2) Class I for the following manual arthroscopic instruments: cannulas, currettes, drill guides, forceps, gouges, graspers, knives, obturators, osteotomes, probes, punches, rasps, retractors, rongeurs, suture passers, suture knotpushers, suture punches, switching rods, and trocars. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 888.9.