K Number
K955820

Validate with FDA (Live)

Date Cleared
1996-03-25

(90 days)

Product Code
Regulation Number
870.1340
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

For percutaneous introduction of catheters into the vasculature while preventing the backflow of blood.

Device Description

16 Et 18 french versions of the Braun Hemostasis Introducer with silicone gasket, in lengths of 10 - 40 cm.

AI/ML Overview

The provided document is a 510(k) summary for a medical device (catheter introducer and vessel dilator) and does not contain information about a study proving device performance against acceptance criteria in the context of AI/ML or diagnostic accuracy. It focuses on demonstrating substantial equivalence to previously cleared devices.

Therefore, I cannot extract the requested information regarding acceptance criteria and performance studies in the context of AI/ML, human readers, ground truth, or training sets from this document.

The document mainly includes:

  • Device Classification and Common Name: Catheter introducer and Vessel dilator (21 CFR 870.1340 and 870.1310).
  • Substantial Equivalence: A comparison table demonstrating similarities to predicate devices (K894446, K931743, K871153, K930057, K945396).
  • Device Description: 16 and 18 French versions of the Braun Hemostasis Introducer with specific gasket and length details.
  • Intended Use: For percutaneous introduction of catheters into the vasculature while preventing blood backflow.
  • Summary/Comparison of Technological Characteristics: Detailed comparison of labeling, packaging, intended use, physical characteristics (French sizes, lengths, materials), and anatomical sites with predicate devices.

This document is for a traditional medical device submission and does not describe a study involving algorithms, AI, or human reader performance.

{0}------------------------------------------------

SUMMARY OF SAFETY AND EFFECTIVENESS 11.

Applicant Name & Address:

B. Braun Medical Inc., Cardiovascular Division, 13000 Hwy 55 Minneapolis, MN 55441-3813 (612) 559-3370

Barbara Atzenhoefer, Regulatory Affairs Manager Contact:

December 19, 1995 Date Prepared:

Common or Usual Name: Catheter introducer and Vessel dilator for percutaneous catheterization

Device Classification Name:

Introducer: 21 CFR Reference- 870.1340, Class II Panel- 74 DYB

11 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1

Dilator: 21 CFR Reference- 870.1310, Class II, Panel- 74 DRE

Substantial Equivilance:

510(k) #ProductManufacturer
K894446Angeion Hemostasis Valve Introducer KitB. Braun Cardiovascular - MN
K931743Burron Cardiovascular AngestatB. Braun Cardiovascular - MN
K871153ANGETEAR Tear-away Introducer KitsB. Braun Cardiovascular - MN
K930057Fluoro-tip Hemostasis Introducer SetB. Braun Cardiovascular - MN
K945396Fluoro-tip Hemostasis Introducer SetB. Braun Cardiovascular - MN

Device Description:

16 Et 18 french versions of the Braun Hemostasis Introducer with silicone gasket, in lengths of 10 - 40 cm. Statement of Intended Use:

For percutaneous introduction of catheters into the vasculature while preventing the backflow of blood. Summary/Comparision of Technological Characteristics:

CharacteristicBraun Hemostasis IntroducersK894446 Hemostasis IntroducerK931743 AngestatK871153 ANGETEAR
A) Labeling/Pkg
Labels & IFUsSee Attachment BAll Braun Hemostasis IntroducerLabel formats are identicalAll Braun HemostasisIntroducer Label formats areidenticalsame informationprovided on pouch andbox labels as onhemostasis labels
Expiration Dating2 years2 years2 years4 years
Pyrogen FreeYesYesYesYes
PackagingTyvek/Polymylar pouchTyvek/Polymylar pouchTyvek/Polymylar pouchTray w/ tyvek lid w/in atyvek/polymylar pouch
B) Intended Usepercutaneous introduction ofcatheters into the vasculaturewhile minimizing the backflowof bloodpercutaneous introduction ofcatheters into the vasculaturewhile minimizing the backflow ofbloodpercutaneous introduction ofcatheters into the vasculaturewhile minimizing the backflowof bloodpercutaneousintroduction of cathetersinto the vasculature
C) Physical Char.
Available french sizes4-18 french5-14 french4-15 french4-16 french
Lengths10-40 cm12-24 cm15-32 cm16-30 cm
gasket materialsiliconeNatural rubbersiliconenone
sheath materialFEP with BaSO₄FEP teflon with BaSO₄FEP with BaSO₄polyethylene withbismuth subcarbonate
dilator materialhigh density polyethylene withbismuth subcarbonatepolyethylene with bismuthsubcarbonatepolyethylene with bismuthsubcarbonateFEP with BaSO₄ orpolyethylene withbismuth subcarbonate
D) Anatomical Sitesvasculaturevasculaturevasculaturevasculature

§ 870.1340 Catheter introducer.

(a)
Identification. A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.(b)
Classification. Class II (performance standards).