(386 days)
A Nittile powder free exam glove is a disposable device, worn on the hand or finger to prevent contamination between examiner and patient. This glove has also been tested for use with Chemotherapy Drugs.
Non-sterile, Powder Free, ambidextrous, textured, beaded cuff, single use, Doffy® Nitrile Examination Glove, Tested for use with Chemotherapy Drugs
This document is a 510(k) premarket notification for a medical device: "Non-sterile, Powder Free, ambidextrous, textured, beaded cuff, single use, Doffy® Nitrile Examination Glove, Tested for use with Chemotherapy Drugs".
The main acceptance criteria for this device, beyond its primary function as an examination glove, is its resistance to permeation by various chemotherapy drugs. This is evaluated by the "Minimum Breakthrough Detection Time (minutes)" for each tested drug.
Here's the breakdown of the requested information based on the provided text:
1. A table of acceptance criteria and the reported device performance
| Acceptance Criteria (Chemotherapy Drug and Concentration) | Reported Device Performance (Min Breakthrough Detection Time - minutes) |
|---|---|
| Carboplatin, 10 mg/ml | >240 |
| Carmustine, 3.3 mg/ml | 15.0 |
| Cisplatin (BCNU), 1.0 mg/ml | >240 |
| Cyclophosphamide (Cytoxan), 20.0 mg/ml | >240 |
| Dacarbazine (DTIC), 10.0 mg/ml | >240 |
| Doxorubicin Hydrochloride, 2.0 m/ml | >240 |
| Etoposide (Toposar), 20.0 mg/ml | >240 |
| Fluorouracil, 5.0 mg/ml | >240 |
| Ifosfamide, 50.0 mg/ml | >240 |
| Methotrexate, 25 mg/ml | >240 |
| MitomycinC, 0.5mg/ml | >240 |
| Mitoxantrone, 2 mg/ml | >240 |
| Paclitaxel (Taxol), 6.0 mg/ml | >240 |
| ThioTEPA, 10.0 mg/ml | 30.1 |
| Vincristine Sulfate, 1.0 mg/ml | >240 |
Note: The document itself specifies a warning based on these results: "WARNING: NOT TO BE USED WITH CARMUSTINE OR THIOTEPA" due to their extremely low permeation times (15.0 minutes and 30.1 minutes respectively). While the provided table states the reported performance, the implied acceptance criteria for safe use would be a breakthrough time considered acceptable for handling (likely much higher than 15 or 30 minutes, commonly 240 minutes per ASTM D6978). The device meets the criteria by reporting its performance, allowing users to make informed decisions and the FDA to determine substantial equivalence.
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
The document does not explicitly state the sample size for the test set (number of gloves tested or repetitions per drug). It also does not explicitly state the country of origin of the data or whether the study was retrospective or prospective. We only know the applicant is YTY Industry (Manjung) Sdn Bhd from Malaysia.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This device is a physical product (nitrile examination glove) and not an AI or diagnostic tool requiring expert interpretation of images or data. Therefore, the concept of "experts establishing ground truth" in the typical sense for test sets of AI models is not applicable here. The ground truth (breakthrough time) is established through standardized laboratory testing protocols (likely ASTM D6978 for chemotherapy drug permeation), not human expert consensus.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable for a physical product performance test. This concept is relevant for studies involving human interpretation or subjective assessment where consensus among multiple reviewers is needed to establish ground truth.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This device is a physical product (glove), not an AI or assistive diagnostic technology.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This device is a physical product (glove), not an algorithm or software.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
The ground truth for the chemotherapy drug permeation is established through laboratory testing using standardized methods, likely following a standard like ASTM D6978 "Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs". This involves precise measurement of the time it takes for a detectable amount of a chemotherapy drug to pass through the glove material.
8. The sample size for the training set
Not applicable. This device is a physical product. The concept of a "training set" is relevant for machine learning models, not for traditional manufacturing and testing of physical goods.
9. How the ground truth for the training set was established
Not applicable, as there is no "training set" in the context of this device.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
March 25, 2023
YTY Industry (Manjung) Sdn Bhd Punitha Samy Senior Manager (Group DCRA & YTY Industry QA) Lot 1422-1424, Batu 10 Lekir Sitiawan, Perak 32020 Malaysia
Re: K220644
Trade/Device Name: Non-sterile, Powder Free, ambidextrous, textured, beaded cuff, single use, Doffy® Nitrile Examination Glove, Tested for use with Chemotherapy Drugs Regulation Number: 21 CFR 880.6250 Regulation Name: Non-Powdered Patient Examination Glove Regulatory Class: Class I. reserved Product Code: LZA, LZC, OPJ Dated: March 20, 2023 Received: March 22, 2023
Dear Punitha Samy:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
Bifeng Qian -S
Bifeng Oian, MD, PhD Assistant Director DHT4B: Division of Infection Control and Plastic Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
Indications for Use
510(k) Number (if known) K220644
Device Name
Non-sterile, Powder Free, ambidextrous, textured, beaded cuff, single use, Doffy® Nitrile Examination Glove, Tested for use with Chemotherapy Drugs
Indications for Use (Describe)
A Nittile powder free exam glove is a disposable device, worn on the hand or finger to prevent contamination between examiner and patient. This glove has also been tested for use with Chemotherapy Drugs.
| Tested Chemotherapy Drug and Concentration | Min Breakthrough Detection Time (minutes) |
|---|---|
| Carboplatin, 10 mg/ml | >240 |
| Carmustine, 3.3 mg/ml | 15.0 |
| Cisplatin (BCNU), 1.0 mg/ml | >240 |
| Cyclophosphamide (Cytoxan), 20.0 mg/ml | >240 |
| Dacarbazine (DTIC), 10.0 mg/ml | >240 |
| Doxorubicin Hydrochloride, 2.0 m/ml | >240 |
| Etoposide (Toposar), 20.0 mg/ml | >240 |
| Fluorouracil, 5.0 mg/ml | >240 |
| Ifosfamide, 50.0 mg/ml | >240 |
| Methotrexate, 25 mg/ml | >240 |
| MitomycinC, 0.5mg/ml | >240 |
| Mitoxantrone, 2 mg/ml | >240 |
| Paclitaxel (Taxol), 6.0 mg/ml | >240 |
| ThioTEPA, 10.0 mg/ml | 30.1 |
| Vincristine Sulfate, 1.0 mg/ml | >240 |
The following chemotherapy drugs and concentration have extremely low permeation time. Carmustine (3.3 mg/ml): 15.0 minutes, Thiotepa (10.0 mg/ml): 30.1 minutes WARNING: NOT TO BE USED WITH CARMUSTINE OR THIOTEPA
Type of Use (Select one or both, as applicable)
Prescription Use (Part 21 CFR 801 Subpart D)
|X | Over-The-Counter Use (21 CFR 801 Subpart C)
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
§ 880.6250 Non-powdered patient examination glove.
(a)
Identification. A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.(b)
Classification. Class I (general controls). The device, when it is a finger cot, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.