K Number
K171398

Validate with FDA (Live)

Date Cleared
2017-07-06

(55 days)

Product Code
Regulation Number
878.4350
Age Range
All
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Dermal Cooling System is a cryosurgical instrument intended for use in dermatologic procedures for the removal of benign lesions of the skin.

Device Description

The Dermal Cooling System is a cryosurgical device used to cool the skin, without the use of cryogenic gases or liquids, for the removal of benign skin lesions. Surface contact cooling is achieved using a thermoelectric cooler (TEC), with an integrated aluminum plate, to lower the temperature of the skin. It is intended for use in a healthcare facility such as a clinic or doctor's office.

The Dermal Cooling System is comprised of the following components:

  • . control unit – houses user interface display, the system controller, and the power converters
  • . chiller – provides circulating coolant to the handpiece to remove heat from the TEC
  • . handpiece - contains the TEC, temperature sensors, the aluminum cooling plate, and user interface elements
  • . isolation transformer – isolates system from AC mains power
  • . cart – houses the isolation transformer, chiller, and control unit
AI/ML Overview

This document describes a 510(k) premarket notification for a Dermal Cooling System, not an AI/ML device. Therefore, the specific questions related to AI/ML device acceptance criteria, training sets, and ground truth establishment are not directly applicable to the provided information.

However, I can extract and structure the information related to the device's acceptance criteria and performance as presented in the document.

Device: Dermal Cooling System (Cryosurgical Unit and Accessories)

Indications for Use: The Dermal Cooling System is a cryosurgical instrument intended for use in dermatologic procedures for the removal of benign lesions of the skin. It is intended to be used by trained healthcare professionals.

Here's an analysis based on the provided document, addressing the relevant points:


1. A table of acceptance criteria and the reported device performance:

TestTest Method/RequirementAcceptance CriteriaReported Device Performance
System Verification
Force sensor accuracyAll measured values must be within specification, and within tolerance of calibrated controls as appropriate (e.g., force and thermistor accuracy)Passed
Thermistor accuracyPassed
Maintenance of cold plate temperature with worst-case simulated heat loadPassed
Power performance characteristics: acceptance of power regulation of input power reverse polarity protectionPassed
Weight (i.e., handpiece, system)Passed
Handpiece LEDs, beeper, and buzzer activationLEDs cycle through color/beeper sequence, buzzer activates per specificationPassed
Maintenance of cold plate temperature for fixed duration at: minimum temperature (-30°C) maximum temperature (+40°C)Temperature maintained within specification for duration of testPassed
Electrical SafetySystem to demonstrate electrical safety, IEC 60601-1Per standard, based on report from Safety Equipment LaboratoryPassed (Implied)
System to demonstrate suitability with respect to electromagnetic interference, IEC 60601-1-2Passed (Implied)
UsabilitySystem to demonstrate usability, IEC 60601-1-6Passed (Implied)
System Validation
System performance with exposure to operating and storage conditionsSystem must pass functional performance test (e.g., pre-cool, cooling, warming) after exposure to operating/storage conditionsPassed
Usability - simulated use (with novice and experienced users) to demonstrate function of modified interface and handpiece featuresUsers must be able to successfully perform all tasks associated with treatment (e.g., turn system on, select treatment plan, initiate treatment, cancel treatment, etc.)Passed
Subsurface temperature test - demonstrate creation of cryoablation zone at depth of 1mmMeasured temperature at 1mm of ≤ -20°CPassed

2. Sample sized used for the test set and the data provenance:

  • Sample Size:
    • For the usability testing, "individuals with varying degrees of experience" were used, including "novice and experienced users." The exact number is not specified.
    • For the in vitro simulated model for subsurface temperature testing, the sample size (number of tests or models) is not specified.
  • Data Provenance: The tests were bench tests and in vitro simulations. There is no mention of country of origin for the data as it's not patient data. The study was performed to support a 510(k) submission, indicating a pre-market evaluation rather than a post-market study or retrospective analysis of clinical data. It is a prospective testing approach for regulatory approval.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

This is a physical device, not an AI/ML system that requires expert-established ground truth in the same way. The "ground truth" for this device's performance is established by objective physical measurements (e.g., temperature, force, weight) and functional performance checks against engineering specifications (e.g., maintain temperature, cycle LEDs).

For usability testing, "individuals with varying degrees of experience" were used, but these were users (not necessarily experts establishing ground truth about the device's function, but rather testing its usability).


4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

Not applicable. This is not an AI/ML system requiring image or data interpretation by multiple readers/experts. The tests described are objective engineering and performance validations.


5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

Not applicable. This is not an AI/ML device, and no MRMC study, human reader improvement, or comparative effectiveness with or without AI assistance was performed or is relevant.


6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

Not applicable. This is a physical medical device. It has software control for its operation, but it's not a standalone diagnostic algorithm.


7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

The "ground truth" for this device's performance is based on:

  • Engineering Specifications: Designed performance parameters (e.g., specific temperatures, power output, weight limits).
  • Physical Measurements: Objective measurements using validated sensors and equipment (e.g., force sensors, thermistors, calibrated controls).
  • Functional Verification: Demonstrating the device performs its intended actions (e.g., LEDs cycle, buzzer activates, pre-cool/cooling/warming modes work).
  • Simulated Model Performance: An in vitro simulated model was used to verify the creation of a cryoablation zone.

The document explicitly states: "No preclinical or clinical testing was performed." and "There were no changes to patient contacting material and, as such, biocompatibility testing was not repeated." This indicates reliance on bench testing and in-vitro models rather than patient outcomes or pathology.


8. The sample size for the training set:

Not applicable. This is not an AI/ML device; there is no "training set" in the context of machine learning. The device's software is rule-based control logic, not a machine learning model.


9. How the ground truth for the training set was established:

Not applicable, as there is no training set for an AI/ML model. The software's functionality is verified against design specifications and validated through testing (as noted in point 7). "Software verification and validation testing was conducted per FDA's 'General Principles of Software Validation; Final Guidance for Industry and FDA Staff' (January 2002)." This guidance focuses on traditional software engineering best practices, not machine learning training.

{0}------------------------------------------------

Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, with a triple-line design extending above them, resembling a bird in flight.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

July 7, 2017

R2 Dermatology. Inc. Mr. Bijesh Chandran Sr. Director, RA/OA 2633 Camino Ramon, Suite 130 San Ramon, California 94583

Re: K171398

Trade/Device Name: Dermal Cooling System Regulation Number: 21 CFR 878.4350 Regulation Name: Cryosurgical Unit and Accessories Regulatory Class: Class II Product Code: GEH Dated: May 10, 2017 Received: May 12, 2017

Dear Mr. Chandran:

This letter corrects our substantially equivalent letter of July 6, 2017.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28. 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Actinclude requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device

{1}------------------------------------------------

related adverse events) (21 CFR 803): good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerelv. Jennifer R. Stevenson -S3 For Binita S. Ashar, M.D., M.B.A., F.A.C.S.

Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Indications for Use

510(k) Number (if known) K171398

Device Name

Dermal Cooling System

Indications for Use (Describe)

The Dermal Cooling System is a cryosurgical instrument intended for use in dermatologic procedures for the removal of benign lesions of the skin.

Type of Use (Select one or both, as applicable)
X Prescription Use (Part 21 CEB 801 Subpart D)Over-The-Counter Use (21 CER 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

510(k) SUMMARY K171398

I.SUBMITTERR2 Dermatology, Inc.2633 Camino Ramon, Suite 130Bishop Ranch 3San Ramon, CA 94583
Contact:Bijesh Chandran, M.S.Senior Director, RAQAR2 Dermatology, Inc.Phone: 925-378-4418Fax: 925-378-4495bchandran@r2derm.com
Date Prepared:July 2, 2017

II. DEVICE

Name of Device:Dermal Cooling System
Common or Usual Name:Cryosurgical unit and accessories
Classification Name:Cryosurgical unit and accessories (21 CFR 878.4350)
Regulatory Class:II
Product Code:GEH

lll. PREDICATE DEVICE

The predicate device is the R2 Dermal Cooling System, K161480.

IV. DEVICE DESCRIPTION

The Dermal Cooling System is a cryosurgical device used to cool the skin, without the use of cryogenic gases or liquids, for the removal of benign skin lesions. Surface contact cooling is achieved using a thermoelectric cooler (TEC), with an integrated aluminum plate, to lower the temperature of the skin. It is intended for use in a healthcare facility such as a clinic or doctor's office.

The Dermal Cooling System is comprised of the following components:

  • . control unit – houses user interface display, the system controller, and the power converters
  • . chiller – provides circulating coolant to the handpiece to remove heat from the TEC
  • . handpiece - contains the TEC, temperature sensors, the aluminum cooling plate, and user interface elements
  • . isolation transformer – isolates system from AC mains power
  • . cart – houses the isolation transformer, chiller, and control unit

{4}------------------------------------------------

The control unit initiates the treatment parameters and receives feedback from temperature sensors in the handpiece during the procedure. The user interface provides the mechanism for selection of the treatment plan, initiation of treatment, and display of treatment status.

The non-sterile, reusable handpiece contains the TEC which cools the aluminum contact plate to the treatment temperature, while the circulation of fluid past the TEC allows for the removal of heat. Thermistors affixed to the aluminum contact plate monitor the temperature at the treatment site.

The Dermal Cooling System has three operational modes: cooling off, pre-cool, and treatment. Cooling off represents the resting state; no power is supplied to the TEC in the handpiece. Pre-cool is the state in which the aluminum contact plate on the handpiece is cooled prior to treatment is the normal treatment state in which temperature is controlled to a pre-defined treatment plan, as selected from the user interface on the control unit. The minimum cooling temperature is -30°C and the maximum warming temperature is 40°C; the maximum treatment duration is 300 seconds.

The user interface is the means by which the system implements each of the operational modes. The software provides three primary functions: setting up the display by which the user can select a treatment plan; establishing communications with the TEC controller to monitor and control temperature; and monitoring treatment progress.

Use of a TEC for cooling at the treatment site, as provided by the Dermal Cooling System, allows the selected temperature to be maintained throughout the duration of treatment. The TEC controller in the control unit communicates to the TEC module in the handpiece, maintaining the treatment plan selected by the user. As the skin is cooled through contact with the aluminum plate, heat is then transferred from the aluminum plate to the TEC module in the handpiece. The chiller maintains a continuous flow of coolant to carry heat way from the TEC module. The Dermal Cooling System generates sufficient thermal power to cool the aluminum contact plate to a pre-set temperature over a pre-set time. The temperature of the cooling surface, as measured by the thermistor affixed to the aluminum contact plate, is fed into the controller such that the surface temperatures can be precisely controlled.

The Dermal Cooling System operates off standard 120 VAC (60 Hz) power to provide controlled, active cooling at the skin interface throughout the procedure.

V. INDICATIONS FOR USE

The Dermal Cooling System is a cryosurgical instrument intended for use in dermatologic procedures for the removal of benign lesions of the skin.

The Dermal Cooling System is intended to be used by trained healthcare professionals.

{5}------------------------------------------------

VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE

The modified Dermal Cooling System and the predicate have these same fundamental scientific technological elements:

  • freezing tissue without the use of cryogenic liquids or gases;
  • contact surface cooling at a targeted treatment site on the skin;
  • . use of a thermoelectric cooler (TEC) to cool the aluminum contact surface; and
  • software control of the treatment parameters and display of the treatment information.

The key differences between the modified device and the predicate are:

  • Updates to user interface and selection of treatment parameters
  • . Relocation of user interface features to handpiece
  • Additional features to convey information on treatment progress
  • Display of applied pressure at skin interface
  • . Increased cooling power
  • Integration of system components into single portable entity
  • . Increase in maximum temperature to 40°C

The modifications do not raise new questions of safety or efficacy for the intended use of cooling at the skin interface for the removal of benign lesions. The intended use and indications for use have not changed; the scientific technological elements have not changed. The modifications to the system were implemented to improve usability of the device, e.g., to reduce the steps required by the user for set up of the system and treatment, and to make it more commercially appealing.

VII. PERFORMANCE DATA

Performance data were provided in support of the substantial equivalence determination, as summarized in the table on the following page. These tests included design verification, electrical safety, usability, and subsurface temperature measurements.

Bench testing was completed to demonstrate the ability of the Dermal Cooling System to meet device and performance specifications (e.g., component accuracy, cooling characteristics).

Usability testing was performed by individuals with varying degrees of experience using the Dermal Cooling System. Individuals were trained in the use of the device and then asked to perform a mock cooling procedure on a simulated test system. All users successfully completed the mock procedure and demonstrated understanding of the device features thereby validating the improvements made to the user interface for this update.

Substantial equivalence testing was performed to demonstrate that the cryoablation zone created with the modified Dermal Cooling System was equivalent to that of the predicate. An in vitro simulated model was used to allow the recording of subsurface measurements documented with the in vitro model verified the creation of a substantially equivalent cryoablation zone.

{6}------------------------------------------------

TestTest method/RequirementAcceptance criteriaResults
SystemVerificationForce sensor accuracyAll measured values must be withinspecification, and within tolerance ofcalibrated controls as appropriate (e.g.,force and thermistor accuracy)Passed
Thermistor accuracyPassed
Maintenance of cold plate temperature with worstcase simulated heat loadPassed
Power performance characteristics:acceptance of power regulation of input power reverse polarity protectionPassed
Weight (i.e., handpiece, system)Passed
Handpiece LEDs, beeper, and buzzer activationLEDs cycle through color/beeper sequence,buzzer activates per specificationPassed
Maintenance of cold plate temperature for fixedduration at:minimum temperature (-30°C) maximum temperature (+40°C)Temperature maintained withinspecification for duration of testPassed
ElectricalSafetySystem to demonstrate electrical safety, IEC60601-1Per standard, based on report from SafetyEquipment Laboratory
System to demonstrate suitability with respect toelectromagnetic interference, IEC 60601-1-2
System to demonstrate usability, IEC 60601-1-6Passed
SystemValidationSystem performance with exposure to operatingand storage conditionsSystem must pass functional performancetest (e.g., pre-cool, cooling, warming) afterexposure to operating/storage conditionsPassed
Usability - simulated use (with novice andexperienced users) to demonstrate function ofmodified interface and handpiece featuresUsers must be able to successfully performall tasks associated with treatment (e.g.,turn system on, select treatment plan,initiate treatment, cancel treatment, etc.)Passed
Subsurface temperature test - demonstratecreation of cryoablation zone at depth of 1mmMeasured temperature at 1mm of ≤ -20°CPassed

Software verification and validation testing was conducted per FDA's "General Principles of Software Validation; Final Guidance for Industry and FDA Staff" (January 2002). The software for this device was considered as moderate level of concern. All tests were successfully passed by meeting the acceptance criteria.

There were no changes to patient contacting material and, as such, biocompatibility testing was not repeated.

No preclinical or clinical testing was performed.

VIII. CONCLUSIONS

The modified Dermal Cooling System and the predicate (as cleared in K161480) have the same intended use and the same technological characteristics e.g., contact cooling without the use of cryogenic gas or liquid, the use of a TEC to cool the aluminum contact plate, and software control. The performance data demonstrate that the device performs to specification and is expected to be equivalent to the predicate, in safety and effectiveness, for the specified use conditions. The modified Dermal Cooling System is, therefore, determined to be substantially equivalent to the predicate.

§ 878.4350 Cryosurgical unit and accessories.

(a)
Identification —(1)Cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories. A cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories is a device intended to destroy tissue during surgical procedures by applying extreme cold.(2)
Cryosurgical unit with a nitrous oxide cooled cryoprobe and accessories. A cryosurgical unit with a nitrous oxide cooled cryoprobe and accessories is a device intended to destroy tissue during surgical procedures, including urological applications, by applying extreme cold.(3)
Cryosurgical unit with a carbon dioxide cooled cryoprobe or a carbon dioxide dry ice applicator and accessories. A cryosurgical unit with a carbon dioxide cooled cryoprobe or a carbon dioxide dry ice applicator and accessories is a device intended to destroy tissue during surgical procedures by applying extreme cold. The device is intended to treat disease conditions such as tumors, skin cancers, acne scars, or hemangiomas (benign tumors consisting of newly formed blood vessels) and various benign or malignant gynecological conditions affecting vulvar, vaginal, or cervical tissue. The device is not intended for urological applications.(b)
Classification. Class II.