When used as a posterior pedicle screw fixation system, the Synthes USS is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, spinal turnor, and failed previous fusion (pseudoanthrosis).
In addition, the Synthes USS is intended for treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation for these patients are L3-S2.
When used as a posterior non-pedicle screw fixation system, the Synthes USS is intended for scoliotic, lordotic, or kyphotic deformities (such as scoliosis, Schuermann's disease), deqenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), and fractures of the posterior thoracolumbar spine.
In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix System.
Anterior components of the USS are intended for anterolateral screw and/or staple fixation for the correction of anterolateral lordotic deformities for the spine, lumbar scollosis, pseudoarthrosis, and fracture or dislocation of the thoracolumbar spine (levels T8-L5).
Anterior components of the USS consists of Stainless Steel or Titanium Universal Spinal threaded rods, Universal Spinal unthreaded rods and Universal Spinal side-opening screws (except 4.2 mm) with a collar and nut, staples, washers, and parallel connectors. The Universal Spinal screws attach to the anterolateral portion of the vertebral body of the thoracolumbar spine (levels T8-L5) and are connected via a Universal Spinal Rod.
Posterior components of the USS are composed of Stainless Steel or Titanium and consist of rods, hooks, side-opening screws with a collar and nut, variable axis screws with rod and screw connector, collar, locking ring and nut, a trans-connector system, open and closed transyerse bars, and parallel connectors, Schanz screws, and clamp with posterior nut.
The provided document is a 510(k) Premarket Notification for a medical device called the "Synthes Universal Spinal System". This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving device performance through clinical studies with acceptance criteria in the way a Pre-Market Approval (PMA) would.
Therefore, the document does not contain the information requested regarding acceptance criteria and a study proving the device meets those criteria. Specifically, it lacks:
- A table of acceptance criteria and reported device performance: This document doesn't define quantitative performance metrics or present data against them.
- Sample size, data provenance, number of experts, adjudication method, MRMC study, standalone performance, or training set details: These are all aspects of a clinical study or performance evaluation that are not present in this 510(k) submission.
Instead, the document asserts substantial equivalence by:
- Stating: "This system is substantially equivalent to previously cleared Synthes spinal systems and is supported by testing which satisfies the requirements of thoracolumbar and sacral fixation." (Page 0)
- Listing: The components of the device (rods, screws, hooks, etc.) and their materials (Stainless Steel or Titanium). (Page 0)
- Defining: The specific indications for use for both posterior pedicle screw fixation, posterior non-pedicle screw fixation, and anterior components. (Page 0, and reiterated on Page 3)
The FDA's response letter (Pages 1-2) confirms that they have "reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976..."
In summary, as this is a 510(k) submission for substantial equivalence, the document focuses on comparing the new device to existing predicate devices, rather than establishing and reporting against new performance acceptance criteria through the detailed study methods you've outlined.
{0}------------------------------------------------
Special 510(k) Premarket Notification - Additional Information
3/31/99
Attachment 2
Summary of Safety and Effectiveness Information [510(k) Summary]
SYNTHES (U.S.A.) 1690 Russell Road Paoli, PA 19301
(610) 647-9700 Contact: Jonathan M. Gilbert 3/23/99
Device: Synthes Universal Spinal System. Anterior components of the USS consists of Stainless Steel or Titanium Universal Spinal threaded rods, Universal Spinal unthreaded rods and Universal Spinal side-opening screws (except 4.2 mm) with a collar and nut, staples, washers, and parallel connectors. The Universal Spinal screws attach to the anterolateral portion of the vertebral body of the thoracolumbar spine (levels T8-L5) and are connected via a Universal Spinal Rod.
Posterior components of the USS are composed of Stainless Steel or Titanium and consist of rods, hooks, side-opening screws with a collar and nut, variable axis screws with rod and screw connector, collar, locking ring and nut, a trans-connector system, open and closed transyerse bars, and parallel connectors, Schanz screws, and clamp with posterior nut.
This system is substantially equivalent to previously cleared Synthes spinal systems and is supported by testing which satisfies the requirements of thoracolumbar and sacral fixation.
When used as a posterior pedicle screw fixation system, the Synthes USS is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic. Jumbar, and sacral spine: deqenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, spinal tumor, and falied previous fusion (pseudoarthrosis).
In addition, the Synthes USS is intended for treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graff having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation for these patients are L3-S2.
When used as a posterior non-pedicle screw fixation system, the Synthes USS is intended for scoliotic, lordotic, or kyphotic deformities (such as scoliosis, Schuermann's disease), deqenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), and fractures of the posterior thoracolumbar spine.
In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix System.
Anterior components of the USS are intended for anterolateral screw and/or staple fixation for the correction of anterolateral lordotic deformities for the spine, lumbar scoliosis, pseudoarthrosis, and fracture or dislocation of the thoracolumbar spine (levels T8-L5).
RA-03 Premarket Notification - Additional Information Low Profile Transconnector
84821520181 28488
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white seal for the Department of Health & Human Services - USA. The seal is circular with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract symbol of three birds in flight.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 3 0 1999
Mr. Jonathan Gilbert Senior Regulatory Affairs Associate Synthes Spine P.O. Box 0548 1690 Russell Road Paoli, Pennsylvania 19301
K990745 Re: Synthes Universal Spinal System Trade Name: Requlatory Class: II Product Codes: MNI, KWP, and MNH Dated: March 5, 1999 Received: March 8, 1999
Dear Mr. Gilbert:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions aqainst misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Requlation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements Please note: concerning your device in the Federal Register. this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or requlations.
{2}------------------------------------------------
Paqe 2 - Mr. Jonathan Gilbert
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diaqnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to
premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Colia M. Witton, Ph.D.
Cella M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Attachment 1
Indications for Use Statement
Page 1 of 1
510(k) Number (if known): NA K 990745
Device Name: Synthes Universal Spinal System
Indications for Use:
When used as a posterior pedicle screw fixation system, the Synthes USS is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, spinal turnor, and failed previous fusion (pseudoanthrosis).
In addition, the Synthes USS is intended for treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation for these patients are L3-S2.
When used as a posterior non-pedicle screw fixation system, the Synthes USS is intended for scoliotic, lordotic, or kyphotic deformities (such as scoliosis, Schuermann's disease), deqenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), and fractures of the posterior thoracolumbar spine.
In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix System.
Anterior components of the USS are intended for anterolateral screw and/or staple fixation for the correction of anterolateral lordotic deformities for the spine, lumbar scollosis, pseudoarthrosis, and fracture or dislocation of the thoracolumbar spine (levels T8-L5).
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use | X |
|---|---|
| ------------------ | --- |
OR
| Over-the-Counter Use | |
|---|---|
| (Per 21 CFR 801.109) |
RA-03
Premarket Notification- Additional Information
Low Profile Transconnector
| (Division Sign-Off) | |
|---|---|
| Division of General Restorative Devices | |
| 510(k) Number | K996743 |
N/A