(193 days)
Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: Neonatal Cephalic, Fetal, Pediatric and Neonatal Abdominal. Typical examinations performed using this transducer are: General abdominal studies including organ surveys, assessment, and retro-peritoneal cavity studies. Pediatric scans of organs and bony structures. Neonatal head studies. Biopsy guidance for tissue or fluid sampling.
The S-VNA 5-8(B) transducer is a mechanically steered curved array (Volume) probe. This is identical to the previously cleared (K940942) endocavitary S-VDW 5-8 probe, with the same materials, same acoustic module, and the same technical performance. The primary mechanical difference with the endocavity S-VDW 5-8 probe is the modified (shorter) shaft, designed to allow use on the outer surface of the body. The VOLUSON® Neonatal transducer S-VNA5-8(B) is an electronic wideband sector-transducer with a center frequency of 6.5 MHz and with switchable scan angles. The direction of insonation is forward in relation to the transducer's longitudinal axis. This device is a hand-held, 128 element, curved linear array probe. In addition to B-Mode and M-Mode, this probe can be operated in steerable pulsed Doppler, Color Doppler, Color Power Angio Doppler, and 3D Imaging. Similar to the S-VDW 5-8 transducer, the S-VN A5-8(B) also allows the performance of a 3D volume scan by internally sweeping the array in a lateral direction, automatically upon a key press. The images thus obtained from sectional planes perpendicular to each other can be displayed synoptically on the screen. This device is intended for use with the Combison/Voluson C530D Diagnostic Ultrasound Scanner for transcutaneous imaging as an aid in the detection and assessment of physical and functional abnormalities using established diagnostic criteria.
This submission K984639 is for a diagnostic ultrasound transducer (S-VNA 5-8(B)) and does not contain detailed information about a study with acceptance criteria and reported device performance in the context of clinical accuracy or diagnostic efficacy. Instead, it focuses on demonstrating substantial equivalence to predicate devices and adherence to safety standards for the hardware itself.
Therefore, many of the requested sections (e.g., sample size for test set, number of experts for ground truth, MRMC study, training set information) cannot be extracted from the provided text as they are not relevant to this type of 510(k) submission.
However, I can provide information based on what is available regarding safety and technological characteristics.
1. Table of Acceptance Criteria and Reported Device Performance
For this specific 510(k) premarket notification, the "acceptance criteria" are primarily related to safety, electrical, and acoustic output standards, and substantial equivalence to predicate devices. The "reported device performance" in this context refers to the device's adherence to these standards and its functional equivalence to existing devices.
| Acceptance Criterion (Standard or Predicate Equivalence) | Reported Device Performance (as stated in the document) |
|---|---|
| Electromechanical Safety Standards: | |
| EN 60601-1 (IEC 601-1) | Designed to meet this standard |
| UL 2601-1 | Designed to meet this standard |
| C22.2 No. 601.1 | Designed to meet this standard |
| CEI/IEC 1157:1992 (Acoustic Output Declaration) | Designed to meet this standard |
| EN 60601-1-2 (Electromagnetic Compatibility) | Designed to meet this standard |
| European Medical Device Directive Certificate | Compliant (issued by TUV) |
| Acoustic Output Limits: | |
| ISPTA ≤ 720 mW/cm² (Maximum Range) | 720 mW/cm² (Matches predicate Track 3 devices) |
| MI ≤ 1.9 (Maximum Range) | 1.9 (Matches predicate Track 3 devices) |
| Biocompatibility: | |
| Patient contact materials are biocompatible | Patient contact materials are exactly the same as previously cleared predicate C530D system and S-VDW 5-8 endocavity transducer (K940942/K974813) |
| Technological Characteristics (Substantial Equivalence): | |
| Identical materials, acoustic module, technical performance to S-VDW 5-8 probe (K940942) | Stated as "identical to the previously cleared (K940942) endocavitary S-VDW 5-8 probe, with the same materials, same acoustic module, and the same technical performance." |
| Functional equivalence for modes (B-Mode, M-Mode, PWD, Color Doppler, Color Power Angio, 3D Imaging) | Operates identically to predicate devices; offers B-mode, M-mode, steerable pulsed Doppler, Color Doppler, Color Power Angio Doppler, and 3D Imaging. |
2. Sample Size Used for the Test Set and Data Provenance
The document does not describe a clinical performance study with a "test set" in the traditional sense of evaluating diagnostic accuracy or efficacy with patient data. The evaluation is centered on hardware specifications, safety standards, and technological equivalence to predicate devices. Therefore, these details are not provided.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications
Not applicable, as no clinical performance study with a test set requiring expert-established ground truth is described.
4. Adjudication Method for the Test Set
Not applicable, as no clinical performance study with a test set requiring adjudication is described.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done
No, an MRMC comparative effectiveness study was not done or described in this submission. This type of study is typically used for AI-augmented diagnostic systems to assess the impact on human reader performance, which is not the subject of this 510(k).
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
No, a standalone algorithm performance study was not done. This submission is for a medical device hardware (ultrasound transducer) and its associated system, not an AI algorithm.
7. The Type of Ground Truth Used
The "ground truth" in this submission relates to:
- Engineering specifications and safety standards: The device's physical construction, electrical properties, and acoustic output are measured against established engineering and regulatory limits.
- Predicate device characteristics: The ground truth for substantial equivalence is the previously cleared specifications and performance of the predicate devices (K974813, K974269, and especially K940942 for the core transducer design). The claim is that the new transducer is "identical" or "substantially equivalent" in key aspects.
8. The Sample Size for the Training Set
Not applicable. This is not an AI/machine learning device requiring a training set.
9. How the Ground Truth for the Training Set Was Established
Not applicable. This is not an AI/machine learning device.
{0}------------------------------------------------
K984639 (3 pages)
asound Transducer
510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
This summary of safety and effectiveness is provided as part of this Premarket Notification in compliance with 21 CFR, Part 807, Subpart E, Section 807.92.
Submitter's name, address, telephone number, contact person: Medison America, Inc. 6616 Owens Drive Pleasanton, CA 94588 Bob Leiker Vice President, Regulatory and Quality Telephone: (925) 463-1830
Prepared December 24, 1998
Name of the device, including the trade or proprietary name if applicable, the 2) common or usual name, and the classification name, if known:
Common/Usual Name: Diagnostic Ultrasound System and Accessories
Proprietary Name:
S-VNA 5-8 and S-VNA 5-8(B) Ultrasound Transducers. Also called the Voluson Neonatal Ultrasound Transducers.
| Classification Names: | FR Number | Product Code |
|---|---|---|
| Diagnostic Ultrasound Transducer | 892.1570 | 90-ITX |
3) Identification of the predicate or legally marketed device:
Medison America, Inc believes that S-VNA 5-8 and S-VNA 5-8(B) Ultrasound Transducers are substantially equivalent to the currently marketed C530D S-VDW 5-8 Transducer, K974813,
{1}------------------------------------------------
Diagnostic Ultrasound Transducer
and the Medison SA8800/ATL HDI 1500 P7-4 Transducer, K974269.
4)
General Ultrasound Scanner Device Description
The Voluson C530D scanner (K940942) is a general purpose, mobile, software controlled, diagnostic ultrasound system. Its function is to acquire ultrasound data and to display the data as B-mode, Mmode, Color-Flow Doppler, Pulsed (PW) Doppler and Power Angio Doppler (K974813), or as a combination of these modes. The Voluson C530D also gives the operator the ability to measure anatomical structures and offers analysis packages that provide information that is used to make a diagnosis by competent health care professionals. The Voluson C530D has real time acoustic output display with two basic indices, a mechanical index and a thermal index, which are both automatically displayed.
Transducer S-VNA 5-8(B) Device Description 5)
The S-VNA 5-8(B) transducer is a mechanically steered curved array (Volume) probe. This is identical to the previously cleared (K940942) endocavitary S-VDW 5-8 probe, with the same materials, same acoustic module, and the same technical performance. The primary mechanical difference with the endocavity S-VDW 5-8 probe is the modified (shorter) shaft, designed to allow use on the outer surface of the body.
The VOLUSON® Neonatal transducer S-VNA5-8(B) is an electronic wideband sector-transducer with a center frequency of 6.5 MHz and with switchable scan angles. The direction of insonation is forward in relation to the transducer's longitudinal axis. This device is a hand-held, 128 element, curved linear array probe. In addition to B-Mode and M-Mode, this probe can be operated in steerable pulsed Doppler, Color Doppler, Color Power Angio Doppler, and 3D Imaging. Similar to the S-VDW 5-8 transducer, the S-VN A5-8(B) also allows the performance of a 3D volume scan by internally sweeping the array in a lateral direction, automatically upon a key press. The images thus obtained from sectional planes perpendicular to each other can be displayed synoptically on the screen. This device is intended for use with the Combison/Voluson C530D Diagnostic Ultrasound Scanner for transcutaneous imaging as an aid in the detection and assessment of physical and functional abnormalities using established diagnostic criteria. The patient contact materials for biological evaluation that are brought into contact with patients are exactly the same as those of the previously cleared Combison/Voluson C530D Diagnostic Ultrasound System and Transducers (K940942/K974813), specifically the S-VDW 5-8 Endocavity transducer.
The S-VNA 5-8(B) Ultrasound Transducer has been designed to meet the following electromechanical safety standards:
- EN 60601-1 (IEC 601-1,) European Norm, Medical Electrical Equipment .
- . UL 2601-1, Underwriters Laboratories Standards, Medical Electrical Equipment
- C22.2 No. 601.1, Canadian Standards Association, Medical Electrical Equipment .
{2}------------------------------------------------
- . CEI/IEC 1157:1992, International Electrotechnical Commission, Requirements for the declaration of the acoustic output of medical diagnostic ultrasonic equipment
- EN 60601-1-2 (IEC 601-1-2,) European Norm, Collateral Standard: Electromagnetic compatibility .
- Compliant with the European Medical Device Directive Certificate issued by TUV. .
5) Intended Use:
The S-VNA 5-8(B) Ultrasound Transducer intended uses as defined FDA guidance documents are:
- . Neonatal Cephalic
- . Fetal
- Pediatric and Neonatal Abdominal .
Typical examinations performed using this transducer are:
- General abdominal studies including organ surveys, assessment, and retro-peritoneal cavity studies. .
- . Pediatric scans of organs and bony structures.
- Neonatal head studies. .
- Biopsy guidance for tissue or fluid sampling. ●
Technological Characteristics: 6)
This device operates identical to the predicate devices in that piezoelectric material in the transducer is used as an ultrasound source to transmit sound waves into the body. Sound waves are reflected back to the transducer and converted to electrical signals that are processed and displayed as a 2D and M-mode, Spectral Doppler, Power Doppler, Power Doppler, and 3D images. Scanhead patient contact materials are biocompatible.
The device's acoustic output limits are:
All Applications:
| (Maximum Range) | |
|---|---|
| ISPTA | 720 mW/cm2 |
| MI | 1.9 |
The limits are the same as predicate Track 3 devices.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized caduceus, which is a symbol often associated with medicine and healthcare. The caduceus is depicted with three lines forming a shape reminiscent of a bird or abstract human form. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the caduceus.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUL 12 1999
Mr. Bob Leiker Vice President, Regulatory and Quality Assurance Medison America, Inc. 6616 Owens Drive Pleasanton, California 94588
Re: K984639 Trade Name: S-VNA 5-8 (B) Diagnostic Ultrasound Transducer Regulatory Class: II 21CFR 892 1570/Procode: 90 ITX Dated: June 4, 1999 Received: June 8, 1999
Dear Mr. Leiker:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
This determination of substantial equivalence applies to the following transducer intended for use with the Voluson C530D Ultrasound System, as described in your premarket notification:
Transducer Model Number
S-VNA 5-8 (B) Diagnostic Ultrasound Transducer
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing
{4}------------------------------------------------
Page 2 - Mr. Bob Leiker
Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic QS inspections, the FDA will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification does not affect any obligation you may have under sections 531 and 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations
This determination of substantial equivalence is granted on the condition that prior to shipping the first device, you submit a postclearance special report. This report should contain complete information, including acoustic output measurements based on production line devices, requested in Appendix G, (enclosed) of the Center's September 30, 1997 "Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers." If the special report is incomplete or contains unacceptable values (e.g., acoustic output greater than approved levels), then the 510(k) clearance may not apply to the production units which as a result may be considered adulterated or misbranded.
The special report should reference the manufacturer's 510(k) number. It should be clearly and prominently marked "ADD-TO-FILE" and should be submitted in duplicate to:
Food and Drug Administration Center for Devices and Radiological Health Document Mail Center (HFZ-401) 9200 Corporate Boulevard Rockville, Maryland 20850
This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4591. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html"".
{5}------------------------------------------------
Page 3 – Mr. Bob Leiker
If you have any questions regarding the content of this letter, please contact Paul M. Gammell, Ph.D. at (301) 594-1212.
Sincerely yours,
signature
CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure(s)
{6}------------------------------------------------
Ultrasound Device Indications Statement
510(k) Number: Device Name:
Voluson C530D Ultrasound System Summary of previously cleared, and new Indications for Use
Indications for Use:
Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:
| Mode of Operation (*includes simultaneous B-mode) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Clinical Applications | A | B | M* | PWD* | CWD* | ColorDoppler | Power(Amplitude)Doppler * | ColorVelocityImaging | Combined(Specify)*See Note 1 | Other(3D Imaging)See Note 2 |
| Ophthalmic | ||||||||||
| Fetal | P | P | P | P | P1 | P | P | |||
| Abdominal | P | P | P | P | P1 | P | P | |||
| Intraoperative:(Specify) | ||||||||||
| IntraoperativeNeurological | ||||||||||
| Pediatric | P | P | P | P | P1 | P | P | |||
| Small Organ(Specify) See Note 3 | P | P | P | P | P1 | P | P | |||
| Neonatal Cephalic - See Note 4 | N | N | N | N | N | N | N | |||
| Adult Cephalic | ||||||||||
| Cardiac | ||||||||||
| Transesophageal | ||||||||||
| Transrectal | P | P | P | P | P1 | P | P | |||
| Transvaginal | P | P | P | P | P1 | P | P | |||
| Transurethral | ||||||||||
| Intravascular | ||||||||||
| Peripheral vascular | P | P | P | P | P1 | P | P | |||
| Laparoscopic | ||||||||||
| Musculo-skeletal Conventional | P | P | P | P | P1 | P | P | |||
| Musculo-skeletal Superficial | ||||||||||
| Other (Specify) |
Mode of Operation (*includes simultaneous B-mode)
N = new indication; P = Previously cleared in K940942, Voluson C530D Ultrasound System; P = Previously cleared in K974813, Voluson CS30D Ultrasound System with Power Doppler; E = added under Appendix E
Other Indications or Modes:
Note 1: PWD/Color Doppler, PWD/Power Doppler.
Note 2: 3D Volume Imaging Mode
For example: thyroid, testicles, salivary gland, breast, lymph nodes, and pediatric patients. Note 3:
Transfontanell diagnostics of neonates. Note 4:
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
Prescription Use
(Per 21 CFR 801.109)
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT,
and Radiological Devices
510(k) Number K984639
{7}------------------------------------------------
Ultrasound Device Indications Statement
| 510(k) Number: | |
|---|---|
| Device Name: | |
| Transducer: |
84639 Voluson C530D Ultrasound System S-VNA 5-8(B) Volume Transducer
Indications for Use:
Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:
Mode of Operation (*includes simultaneous B-mode)
| Clinical Applications | A | B | M* | PWD* | CWD* | ColorDoppler* | Power(Amplitude)Doppler * | ColorVelocityImaging | Combined(Specify)*See Note 1 | Other(3D Imaging)See Note 2 |
|---|---|---|---|---|---|---|---|---|---|---|
| Ophthalmic | ||||||||||
| Fetal | ||||||||||
| Abdominal | N | N | N | N | N | N | N | |||
| Intraoperative: | ||||||||||
| (Specify) | ||||||||||
| Intraoperative | ||||||||||
| Neurological | ||||||||||
| Pediatric | N | N | N | N | N | N | N | |||
| Small Organ | ||||||||||
| (Specify) | ||||||||||
| Neonatal Cephalic - See Note 4 | N | N | N | N | N | N | N | |||
| Adult Cephalic | ||||||||||
| Cardiac | ||||||||||
| Transesophageal | ||||||||||
| Transrectal | ||||||||||
| Transvaginal | ||||||||||
| Transurethral | ||||||||||
| Intravascular | ||||||||||
| Peripheral vascular | ||||||||||
| Laparoscopic | ||||||||||
| Musculo-skeletal Conventional | ||||||||||
| Musculo-skeletal Superficial | ||||||||||
| Other (Specify) |
N = new indication; P = Previously cleared in K940942, Voluson C530D Ultrasound System; P = Previously cleared in K974813, Voluson CS30D Ultrasound System with Power Doppler; E = added under Appendix E
Other Indications or Modes:
Note 1: PWD/Color Doppier, PWD/Power Doppler.
Note 2: 3D Volume Imaging Mode.
Transfontanell diagnostics of neonates. Note 4:
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
scription lise (Per 21 CFR 801.109)
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT,
and Radiological Devices
Stick Number 5984634
N/A