K Number
K970377

Validate with FDA (Live)

Date Cleared
1997-03-31

(56 days)

Product Code
Regulation Number
886.4370
Age Range
All
Reference & Predicate Devices
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

To perform microlamellar keratoplasty for the correction of myopia or hyperopia

Device Description

Power unit, Turbine motor, Fixed keratome head, Keratome blade, Pneumatic fixation rings, Applanation lenses

AI/ML Overview

This device is a surgical keratome, intended to perform microlamellar keratoplasty for the correction of myopia or hyperopia. The provided text is a summary comparing the submitted device with predicate devices. It does not contain information about acceptance criteria or a study proving the device meets acceptance criteria. It primarily focuses on comparing the features and specifications of the submitted device with existing predicate devices to demonstrate substantial equivalence, rather than presenting performance data against defined acceptance criteria.

Therefore, I cannot provide the requested information from the given text.

To be able to answer your questions, I would need a document that includes:

  • Specific performance metrics (e.g., cut depth accuracy, cut quality, safety outcomes).
  • Numerical acceptance criteria for these metrics.
  • Details of a clinical or non-clinical study (e.g., preclinical testing, animal studies, human clinical trials) where the device's performance was evaluated against these criteria.
  • Information regarding sample sizes, ground truth establishment, expert qualifications, and adjudication methods for such a study.

{0}------------------------------------------------

HAR 3 | 1997

K970377

SAFETY AND EFFECTIVENESS SUMMARY K970377 p. 1/2

Plancon Instruments, 15 Rue Georges Besse, 92160 Antony, France Te Contact person: Mr. Alain DUPRAT, General Manager Date: December 13, 1996

ilist

(33-1) 46 74 46el.:74
-----------------------------------
Predicated device ①510 K Document numberK 960395Predicated device ②510 document number :Not knownPredicated device ③510 K document number :K 935342Submitted device
Designation /FeaturePLANCON INSTRUMENTSMicrolamellar KeratomeEYE TECHNOLOGYSCMDPLANCON INSTRUMENTSMicrolamellar Keratome(single piece head)
Intended useTo perform microlamellarkeratoplasty for the correctionof myopia or hyperopiaTo perform micro lamellarkeratoplasty for the correctionof myopia or hyperopiaTo perform micro lamellarkeratoplasty for the correctionof myopia or hyperopiaTo perform microlamellarkeratoplasty for the correctionof myopia or hyperopia
SystemcompositionPower unitTurbine motorAdjustable keratome headKeratome bladePneumatic fixation ringsApplanation lensesPlate checking gaugePower unitTurbine motorAdjustable keratome headKeratome bladePneumatic fixation ringsApplanation lensesPlate checking gaugePower unitTurbine motorAdjustable keratome headKeratome bladePneumatic fixation ringsApplanation lensesPlate checking gaugePower unitTurbine motorFixed keratome headKeratome bladePneumatic fixation ringsApplanation lenses
Power unitVacuum pumpBatteryVacuum release valveKnob to regulate gas pressureGas & vacuum pressuregaugesVacuum & turbine quickconnectorsBattery charger unitVacuum pumpBatteryVacuum release valveKnob to regulate gas pressureGas & vacuum pressuregaugesVacuum & turbine quickconnectorsBattery charger unitVacuum pumpBatteryVacuum release valveKnob to regulate gas pressureGas & vacuum pressuregaugesVacuum & turbine quickconnectorsBattery charger unitVacuum pumpBatteryVacuum release valveKnob to regulate gas pressuGas & vacuum pressuregaugesVacuum & turbine quickconnectorsBattery charger unit

参考
参考

{1}------------------------------------------------

K970377

(

!

11


SAFETY AND EFFECTIVENESS SUMMARY K970377 p. 2/2

Predicated device ①510 K Document numberK 960395Predicated device ②510 document number :Not knownPredicated device ③510 K document number :K 935342Submitted device
Designation /FeaturePLANCON INSTRUMENTSMicrolamellar KeratomeEYE TECHNOLOGYSCMDPLANCON INSTRUMENTSMicrolamellar Keratome(single piece head)
Turbine motorGas poweredAdjustable speed 0 to 20 000RPM (recommended 14 000RPM)Material : stainless steel,titanium and aluminium.No gear systemGas poweredAdjustable speedMaterial : stainless steelNo gear systemGas poweredAdjustable speed from 10 to24 000 RPMPre-set speed 14 000 RPMMaterial : stainless steel andbrassNo gear systemGas poweredAdjustable speed 0 to 20 000RPM (recommended 14 000RPM)Material : stainless steel,titanium and aluminium.No gear system
KeratomeMaterial : stainless steelAdjustableSafety : maximum cut depth,and checking gaugeMaterial : stainless steelAdjustablePermanent adjustable headwith adjustment knobSafety : maximum cut depthand checking gaugeMaterial : stainless steelAdjustableSafety : maximum cut depthand checking gaugeMaterial : stainless steelFixed single piece headSafety : only one cut depthallowed by head principle
Pneumaticfixation ringsMaterial : stainless steelDouble dovetailsMaterial : stainless steelDouble dovetailsMaterial : stainless steelDouble dovetailsMaterial : stainless steelDouble dovetails
ApplanationlensesMaterial : clear plastic +stainless handleEngraved inner reticlediameterMaterial : clear plastic +stainless handleEngraved inner reticlediameterMaterial : clear plastic +stainless handleEngraved inner reticlediameterMaterial : clear plastic +stainless handleEngraved inner reticlediameter

§ 886.4370 Keratome.

(a)
Identification. A keratome is an AC-powered or battery-powered device intended to shave tissue from sections of the cornea for a lamellar (partial thickness) transplant.(b)
Classification. Class I.