892.2020
Age Range
All
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The KODAK Digital Science Medical Image Manager is an extension of the KODAK Health Sciences Imagelink System with the intended use to be used as a network gateway to a host of image management and printing devices.
The KODAK Digital Science Medical Image Manager will provide network access for both point -to - point and network capable image and information sources. The Image Manager will provide a value added service to point - to - point devices by adding services including routing to multiple destinations and access to multiple printers. However, evaluation of soft copy or hard copy output provides adequate opportunity for competent human intervention. PACS are not represented to be used in supporting or sustaining human life, nor do they represent a potential for unreasonable risk of illness or injury.

Device Description

The general hardware configuration of the KODAK digital Science Medical Imager contains the following major components:
-Power Supply
-Main System Circuit Board
-Hard Dick
-Internal Removable Media
-Keypad
Optional Accessories:
-Keypad Accessories
-Mini-keypad
-Microphone
-Modality Store Connection
-Keyboard
-Bar Code Reader
-Magnetic Stripe Reader

AI/ML Overview

This document does not contain information about acceptance criteria or a study proving the device meets acceptance criteria. The provided text is a 510(k) premarket notification for the KODAK Digital Science Medical Image Manager, focusing on its general information, intended use, and a comparison of its features with a previous Kodak product. It details hardware components, power requirements, environmental conditions, acquisition unit specifications (disk storage, network capability, video/digital inputs, capture/store times), and reader unit specifications (inputs, outputs, image presentation options).

Therefore, I cannot provide the requested information.

{0}------------------------------------------------

K960382

KODAK DIGITAL SCIENCE MEDICAL IMAGE MANAGE Premarket Notification: 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS

K960382

INTRODUCTION I.

The KODAK Digital Science Medical Image Manager is an extension of the KODAK Health Sciences Imagelink System with the intended use to be used as a network gateway to a host of image management and printing devices.

GENERAL INFORMATION II.

APR 1 7 1996

Name of Manufacture: Eastman Kodak Company Health Sciences Division 18325 Waterview Parkway Dallas, Texas 75252-8026

Establishment Registration Number:

Device Name:

KODAK Digital Science Medical Image Manager

Device Classification:

Class I Device

III. THE DEVICE

The general hardware configuration of the KODAK digital Science Medical Imager contains the following major components:

-Power Supply -Main System Circuit Board -Hard Dick -Internal Removable Media -Keypad

Optional Accessories: -Keypad Accessories -Mini-keypad -Microphone -Modality Store Connection -Keyboard -Bar Code Reader -Magnetic Stripe Reader

{1}------------------------------------------------

KODAK DIGITAL SCIENCE MEDICAL IMAGE MANAGE Premarket Notification: 510(k) IV. INDICATIONS FOR USE

The KODAK Digital Science Medical Image Manager will provide network access for both point -to - point and network capable image and information sources. The Image Manager will provide a value added service to point - to - point devices by adding services including routing to multiple destinations and access to multiple printers. However, evaluation of soft copy or hard copy output provides adequate opportunity for competent human intervention. PACS are not represented to be used in supporting or sustaining human life, nor do they represent a potential for unreasonable risk of illness or injury.

V. COMPARISON OF FEATURES

KODAK EKTASCANKODAK DIGITAL
IMAGELINKSCIENCE
Ultrasound SystemRemote Network Interface

General

General
K-NumberK-931551This 510(k)
PowerRequirements90-132VAC/47-63Hz180-264VAC/47-63Hz100VAC +/-10%,50/60 Hz (+/-2%)250w120VAC +/-10%,60Hz (+/-2%)250w220VAC +/-10%,50/60 Hz (+/-2%)250w240VAC +/-10%,50/60 Hz (+/-2%)250w
Environmental15-35 degrees C / 15-90% RHnon-condensing41-95 degrees F / 15-80% RHnon-condensing

Acquisition Unit

Removable Disk2.5" Hard Disk3.5" Floppy, 3.5" Magneto Optical (MOD)
Disk Storage Capacity30,40,60,80,105 Mbytes1-4 GBytes
Network CapabilityEthernetEthernet
Video Image InputsMonochrome:RS-170/CCIRRed,Green,Blue (RGB)Monochrome:RS-170/CCIRRed,Green,Blue (RGB),CINE Loop, Motion Video
Digital Image InputsNone8 and 12 Bit Digital Images in UBMED Format
Serial Control InputsNoneRS-232, RS-422
Image Capture Time1/30 second (.25MB)Grayscale Video: .2s (1MB)Color Video: .25s(1MB)8-Bit Digital: .2s (1MB)
Image Store TimeGrayscale Video: <2 seconds (.25MB)Color Video: <5 seconds (.75MB)Grayscale Video: .5s (1MB)Color Video: 1.5s (3MB)8-Bit Digital: 5s (1MB)

Reader Unit

InputsRemovable Disk CartridgeEthernet - ACR/NEMA Format3.5" Floppy, 3.5" Magneto OpticalEthernet - DICOM Format, HIS/RIS Interface
OutputsSCSI, Video, RS-485, RS-422, RS-232Ethernet, RS-485, High Speed Optical, Modem,ATM, SCSI
Image Presentation1,2,4,6,8,9,12,15,16,20,24,30,351,2,4,6,8,9,12,15,16,20,24,30,35.slide

N/A