K Number
K251255

Validate with FDA (Live)

Manufacturer
Date Cleared
2025-07-22

(90 days)

Product Code
Regulation Number
878.4160
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The LymphaTech Mobile 3D Measuring Tool is a software application that uses input from the Structure Sensor, an off-the-shelf long-wave infrared camera, to measure the diameter, surface area, volume, and perimeter/circumference of a part of the body. The 3D Measuring Tool is non-contact with respect to the patient and provides an adjunctive tool to help a qualified health care professional measure and record body part data. The device uses input from the Structure Sensor camera to accurately capture and construct a 3D model of a patient's anatomy. It is intended for trained and qualified healthcare professionals, who are trained in its use. The 3D Measuring Tool is to be used on a patient population that includes non-pregnant female or male adults. The 3D Measuring Tool is intended to be used in any environment where health care is provided by a qualified health care professional. The 3D Measuring Tool does not provide a diagnosis or therapy.

Device Description

The LymphaTech Mobile 3D Measuring Tool is a standalone software mobile application that uses a high-accuracy off-the-shelf long-wave infrared camera for measuring the diameter, surface area, volume, and circumference of a part of the body. The software allows clinicians to measure body region volume, circumference, surface area, and length with high precision. Specifically, this device uses an off-the-shelf depth sensing scanner, which is a type of long-wave infrared camera, together with an off-the-shelf iPad to acquire complete 3D renderings of the body regions.

AI/ML Overview

The provided document is an FDA 510(k) clearance letter and its associated 510(k) summary for the LymphaTech Mobile 3D Measuring Tool. While it outlines the device's intended use, comparison to a predicate, and types of testing performed, it does not include the specific acceptance criteria or detailed results of the study that proves the device meets those criteria.

Specifically, the document states: "Non-Clinical Bench Performance Testing including linear diameter and length accuracy testing, circumference and surface area testing, volume accuracy testing as compared to water displacement and perometry, and inter-operator variability assessment." However, it does not provide:

  • The quantitative acceptance criteria (e.g., "accuracy within X%").
  • The reported performance statistics (e.g., "average accuracy of Y% for diameter").
  • Details about the sample sizes for the test set, data provenance, ground truth establishment, or multi-reader studies.

Therefore, I cannot fulfill all parts of your request based solely on the provided text. I will answer what can be inferred and explicitly state what information is missing.


Acceptance Criteria and Device Performance

Information Missing: The document states that "Non-Clinical Bench Performance Testing" was conducted, including "linear diameter and length accuracy testing, circumference and surface area testing, volume accuracy testing as compared to water displacement and perometry, and inter-operator variability assessment." However, it does not specify the quantitative acceptance criteria (e.g., a target accuracy percentage or deviation limit) for any of these measurements, nor does it present the reported device performance statistics (e.g., the actual accuracy achieved).

Therefore, a table of acceptance criteria and reported device performance cannot be generated from the given text.


Study Details

Here's what can be extracted or inferred about the study performed, with clear notes on missing information:

1. Sample sized used for the test set and the data provenance:

  • Sample Size (Test Set): Not specified. The document mentions "Performance testing of the subject device was conducted on humans," but it does not provide the number of subjects or scans in the test set.
  • Data Provenance: The document states "Performance testing of the subject device was conducted on humans." The country of origin is not specified, and it is implied to be a prospective collection of data for the purpose of the study, but this is not explicitly stated.

2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

  • Number of Experts: Not specified.
  • Qualifications of Experts: Not specified.
  • Note: The document states that "volume accuracy testing as compared to water displacement and perometry" was performed. Water displacement and perometry are objective physical measurement methods often considered 'gold standards' for volume and circumference, rather than requiring expert consensus in the same way, for example, classifying a medical image would.

3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

  • Adjudication Method: Not specified. Given the nature of the measurements (physical dimensions),, it's more likely that direct comparison to ground truth (water displacement/perometry) would be the primary method for accuracy rather than expert adjudication, but this is not explicitly stated.

4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

  • MRMC Study: No, this type of study was not performed or reported. The device is described as an "adjunctive tool to help a qualified health care professional measure and record body part data." The testing description ("inter-operator variability assessment") suggests evaluating consistency among users of the device, rather than comparing human performance with and without device assistance.
  • Effect Size: N/A, as an MRMC study comparing human readers with/without AI assistance was not reported.

5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

  • Standalone Performance: Yes, implicitly. The "Non-Clinical Bench Performance Testing" described for linear diameter, length, circumference, surface area, and volume accuracy against objective ground truths (water displacement, perometry) represents standalone algorithm performance concerning its measurement capabilities. While a human operates the device, the accuracy of the measurements generated by the software is what's being assessed against physical standards, which is a form of standalone performance.

6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

  • Type of Ground Truth: The ground truth for measurement accuracy included water displacement and perometry. These are objective, gold-standard physical measurement techniques.

7. The sample size for the training set:

  • Sample Size (Training Set): Not specified. The document describes "Software Verification Testing" but does not detail any machine learning model training or associated training data sets. The device is referred to as "software only."

8. How the ground truth for the training set was established:

  • Ground Truth Establishment (Training Set): Not specified. As the document doesn't explicitly mention a machine learning component requiring a distinct training set, this information is not provided. The software's core function is to construct a 3D model and perform geometric calculations; the accuracy of these calculations is what the bench testing verifies against physical ground truths.

FDA 510(k) Clearance Letter - LymphaTech Mobile 3D Measuring Tool

Page 1

U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov

Doc ID # 04017.07.05

July 22, 2025

Lymphatech, Inc.
℅ Grace Powers
Founder/ Principal Consultant
Powers Regulatory Consulting
2451 Cumberland Parkway SE
Suite 3740
Atlanta, Georgia 30339

Re: K251255
Trade/Device Name: LymphaTech Mobile 3D Measuring Tool
Regulation Number: 21 CFR 878.4160
Regulation Name: Surgical Camera And Accessories
Regulatory Class: Class I
Product Code: SFG
Dated: April 21, 2025
Received: April 23, 2025

Dear Grace Powers:

We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Page 2

K251255 - Grace Powers Page 2

Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).

Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.

All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-

Page 3

K251255 - Grace Powers Page 3

assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

YAN FU -S Digitally signed by YAN FU -S Date: 2025.07.22 12:31:24 -04'00'

for Tanisha Hithe
Assistant Director
DHT4A: Division of General Surgery Devices
OHT4: Office of Surgical and
Infection Control Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health

Enclosure

Page 4

FORM FDA 3881 (6/20) Page 1 of 1 PSC Publishing Services (301) 443-6740 EF

DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration

Indications for Use

Form Approved: OMB No. 0910-0120
Expiration Date: 06/30/2023
See PRA Statement below.

510(k) Number (if known)
K251255

Device Name
LymphaTech Mobile 3D Measuring Tool

Indications for Use (Describe)
The LymphaTech Mobile 3D Measuring Tool is a software application that uses input from the Structure Sensor, an off-the-shelf long-wave infrared camera, to measure the diameter, surface area, volume, and perimeter/circumference of a part of the body. The 3D Measuring Tool is non-contact with respect to the patient and provides an adjunctive tool to help a qualified health care professional measure and record body part data. The device uses input from the Structure Sensor camera to accurately capture and construct a 3D model of a patient's anatomy. It is intended for trained and qualified healthcare professionals, who are trained in its use. The 3D Measuring Tool is to be used on a patient population that includes non-pregnant female or male adults. The 3D Measuring Tool is intended to be used in any environment where health care is provided by a qualified health care professional. The 3D Measuring Tool does not provide a diagnosis or therapy.

Type of Use (Select one or both, as applicable)
☒ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.
DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

Page 5

510(k) Summary: K251255

In accordance with 21 CFR §807.92 and the Safe Medical Devices Act of 1990, the following information is provided for the LymphaTech Traditional 510(k) premarket notification.

Sponsor: LymphaTech

Submission Contact: Grace Powers, FRAPS, MS, MBA, RAC
Founder/Principal Consultant
Powers Regulatory Consulting
grace@powersregulatory.com

Submission Date: April 21, 2025

Subject Device:

  • Trade Name: LymphaTech Mobile 3D Measuring Tool
  • Common Name: Camera, surgical, measurement
  • Classification Name: Surgical camera and accessories
  • Regulation: 21 CFR §878.4160
  • Regulatory Classification: Class 1
  • Product Code: SFG

Predicate Device: Scout (K131596)

Reference Device: decimal3D (K192554)

Device Description

The LymphaTech Mobile 3D Measuring Tool is a standalone software mobile application that uses a high-accuracy off-the-shelf long-wave infrared camera for measuring the diameter, surface area, volume, and circumference of a part of the body. The software allows clinicians to measure body region volume, circumference, surface area, and length with high precision. Specifically, this device uses an off-the-shelf depth sensing scanner, which is a type of long-wave infrared camera, together with an off-the-shelf iPad to acquire complete 3D renderings of the body regions.

Intended Use/Indications for Use

The LymphaTech Mobile 3D Measuring Tool is a software application that uses input from the Structure Sensor, an off-the-shelf long-wave infrared camera, to measure the diameter, surface area, volume, and perimeter/circumference of a part of the body. The 3D Measuring Tool is non-contact with respect to the patient and provides an adjunctive tool to help a qualified health care professional measure and record body part data. The device uses input from the Structure Sensor camera to accurately capture and construct a 3D model of a patient's anatomy. It is intended for trained and qualified healthcare professionals, who are trained in its use. The 3D Measuring Tool is to be used on a patient population that includes non-pregnant female or male adults. The 3D Measuring Tool is intended to be used in any environment where health care is provided by a qualified health care professional. The 3D Measuring Tool does not provide a diagnosis or therapy.

Substantial Equivalence

An overview comparison of the LymphaTech Mobile 3D Measuring Tool (subject device) compared to the predicate device is presented in the table below. The reference device (decimal3D) uses the same high-accuracy off-the-shelf long-wave infrared camera for a different intended use.

Page 6

Table 1: Device Comparison

Subject Device: LymphaTech Mobile 3D Measuring ToolPredicate Device: WoundVision ScoutComparison
Regulatory information
ManufacturerLymphaTechWoundVision LLCN/A
Product CodeSFGFXNA new product code
Regulation Number21 CFR 878.416021 CFR 878.4160Identical.
Device Classification NameCamera, Surgical, MeasurementTape, Camera, SurgicalSimilar - Both for measurement
Device Classification11Identical.
Indication for UseThe LymphaTech Mobile 3D Measuring Tool is a software application that uses input from the Structure Sensor, an off-the-shelf long-wave infrared camera, to measure the diameter, surface area, volume, and perimeter/circumference of a part of the body. The 3D Measuring Tool is non-contact with respect to the patient and provides an adjunctive tool to help a qualified health care professional measure and record body part data. The device uses input from the Structure Sensor camera to accurately capture and construct a 3D model of a patient's anatomy. It is intended for trained and qualified healthcare professionals, who are trained in its use. The 3D Measuring Tool is to be used on a patient population that includes non-pregnant female or male adults. The 3D Measuring Tool is intended to be used in any environment whereThe Scout is a combination digital camera and long-wave infrared camera. The digital camera is indicated for the use of capturing visual images to measure the diameter, surface area, and perimeter of a part of the body or two body surfaces. The long-wave infrared camera is indicated for the use of capturing thermal images to measure the thermal intensity data of a part of the body or two body surfaces. Both components of the Scout are non-contact with respect to the patient and provide an adjunctive tool to help a trained and qualified health care professional measure and record external wound and body surface data. Intended for qualified healthcareSimilar- Both devices measure the diameter, surface area, and perimeter of a part of the body. The subject device also measures volume. The predicate device measures temperature.

Page 7

Subject Device: LymphaTech Mobile 3D Measuring ToolPredicate Device: WoundVision ScoutComparison
health care is provided by a qualified health care professional. The 3D Measuring Tool does not provide a diagnosis or therapy.professionals who are trained in its use, the Scout is a non-invasive and non-radiating device. The Scout is to be used on a patient population that includes non-pregnant female or male patients 18 years of age or older. The Scout is intended to be used in hospital, acute and sub-acute care settings, long term care, surgery, health care practitioner facilities, outpatient, home healthcare, or in any environment where health care is provided by a qualified health care professional. The Scout does not provide a diagnosis or therapy.
Rx or OTCRx OnlyRx OnlyIdentical.
Principles of OperationThe subject device is software only.The predicate device is a digital and thermal long-wave infrared camera that measures the desired body part.Similar- Both devices record measurements.
Setting of UseClinical settingClinical settingIdentical.
UserClinicianClinicianIdentical.
Patient ContactNon-patient contactingNon-patient contactingIdentical.
MeasurementsMeasure the diameter, surface area, volume and perimeter/circumference of a part of the body.Measure the diameter, surface area, and perimeter of a part of the body or the distanceSimilar- physical measurements. The subject device measures volume and does not

Page 8

Subject Device: LymphaTech Mobile 3D Measuring ToolPredicate Device: WoundVision ScoutComparison
between two body surfaces. Measures temperature.measure temperature.
TestingBench testing and clinical usability testing.Bench testing and clinical usability testing.Identical types of testing.
Software and Connectivity
Storage of dataElectronically records and stores source data.Electronically records and stores source data.Identical.
Device connectivityNone required. Measurements and images remain on iPad.Measurements and images can be updated to electronic medical records and are stored in the cloud. Connects to a portal and EMR.Different- The predicate device requires connectivity to access data.
Hardware
Long-wave Infrared CameraMeasures infrared radiation on objects.Measures infrared radiation on objects.Identical.
Computing DeviceOff-the-Shelf iPad running iPad iOS 14 or higher.N/A- No iPad or mobile device is required for the predicate device.Different computing devices.

Performance Testing

Performance testing of the subject device was conducted on humans to show usability and accuracy of the software. There are no device-specific guidance documents, special controls document, and/or requirements in a device-specific regulation that is applicable to the subject device.

A list of the testing for the LymphaTech Mobile 3D Measuring Tool is listed below:

  • Software Verification Testing
  • Cybersecurity Testing
  • Usability Testing
  • Non-Clinical Bench Performance Testing including linear diameter and length accuracy testing, circumference and surface area testing, volume accuracy testing as compared to water displacement and perometry, and inter-operator variability assessment.

Conclusion

The LymphaTech Mobile 3D Measuring Tool is substantially equivalent to the legally marketed predicate device as demonstrated by the similar indication for use, similar technologies and performance data, and does not raise different questions of safety and effectiveness.

§ 878.4160 Surgical camera and accessories.

(a)
Identification. A surgical camera and accessories is a device intended to be used to record operative procedures.(b)
Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 878.9.