K Number
K192416

Validate with FDA (Live)

Manufacturer
Date Cleared
2019-10-01

(27 days)

Product Code
Regulation Number
888.3353
Age Range
All
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The BIOLOX delta Ceramic Femoral Heads are modular components used in total hip arthroplasty and are indicated for the following:
• Patients suffering from severe hip pain and disability due to rheumatoid arthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur.
• Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis.
• Patients suffering from disability due to previous fusion; patients with previously failed endoprostheses and/or total hip components in the operative extremity.
• Patients with acute femoral neck fractures.

The BIOLOX OPTION Ceramic Femoral Head System is comprised of modular components used in primary or revision total hip arthroplasty and is indicated for the following:
• Patients suffering from severe hip pain and disability due to rheumatoid arthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur.
• Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis.
• Patients suffering from disability due to previous fusion.
• Patients with previously failed endoprostheses and/or total hip components in the operative extremity.
• Patients with acute neck fractures.

Device Description

The BIOLOX delta Ceramic Femoral Heads are fabricated from an alumina matrix composite and are available in diameters of 28, 32, 36, and 40mm with a range of offsets to accommodate various patient anatomies. They serve as an alternative to both metal and alumina ceramic femoral heads for use in total hip arthroplasty.

The BIOLOX OPTION Ceramic Femoral Head System consist of a ceramic head fabricated from an alumina matrix composite available in diameters of 28, 32, 36, and 40 mm and a titanium adapter for the femoral stem cone with a range of offsets to accommodate various patient anatomies. The system serves as an alternative to both metal and alumina ceramic femoral heads and is for use in both primary and revision total hip arthroplasty.

AI/ML Overview

This appears to be a 510(k) summary for a medical device (BIOLOX Delta Ceramic Femoral Heads and BIOLOX Option Ceramic Femoral Head System), not a study describing acceptance criteria and performance of a device based on AI/ML or image analysis. The document focuses on demonstrating substantial equivalence to predicate devices for regulatory clearance, primarily through engineering analyses and material equivalence, rather than a clinical study with a test set, ground truth, or human reader involvement.

Therefore, many of the requested fields cannot be extracted directly from this document as they are not applicable to this type of regulatory submission. This document does not describe an AI/ML-based device that would typically have the requested performance metrics.

However, I can extract information related to the performance data presented within the context of a 510(k) submission for mechanical/material equivalence.

Here's a breakdown of what can and cannot be answered based on the provided text:

1. A table of acceptance criteria and the reported device performance

Acceptance Criteria (General for Mechanical Devices)Reported Device Performance (from text)
Material Equivalence (e.g., ISO 6474-2, ISO 5832-3/ASTM F136)Demonstrated material equivalence to predicate devices (K071535, K130899, K073567).
Wear Justification (ISO 7206-2)Provided rationales for wear justification according to ISO 7206-2.
Range of Motion (ISO 21535)Provided rationales for Range of Motion according to ISO 21535.
No new questions of safety and effectivenessPerformance data and analyses demonstrate that differences do not raise new questions of safety and effectiveness.
At least as safe and effective as legally marketed predicate devicesSubject devices are at least as safe and effective as the legally marketed predicate devices.

2. Sample size used for the test set and the data provenance

  • Not Applicable in the way implied by the request for an AI/ML study.
  • The performance data relies on engineering analyses and material testing, not a "test set" of clinical cases or images. The "samples" would refer to test articles/components used in the mechanical and material tests. The document does not specify the number of individual components tested but refers to the completion of the tests.
  • Data Provenance: The tests are likely conducted in a controlled laboratory environment by the manufacturer or a third-party testing facility, adhering to specified ISO/ASTM standards. The country of origin of these tests is not explicitly stated but would typically be where the manufacturer (Zimmer GmbH, Switzerland) conducts or commissions such testing.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

  • Not Applicable in the way implied by the request for an AI/ML study.
  • This device is a mechanical implant. "Ground truth" in this context would refer to the validated standards and specifications (e.g., ISO standards) used for material and mechanical properties, not expert consensus on clinical cases. The interpretation of test results would be done by engineers and scientists (who are experts in their field) in accordance with these standards.

4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

  • Not Applicable. Adjudication methods like 2+1 or 3+1 are used for establishing clinical ground truth, especially with image interpretation. For mechanical testing, adherence to standardized test protocols and data analysis governs the results.

5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

  • Not Applicable. This is a mechanical implant device, not an AI/ML diagnostic aid that involves human readers interpreting cases.

6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

  • Not Applicable. This is a mechanical implant device, not an AI/ML algorithm.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

  • For this type of device, the "ground truth" (or reference standard) is primarily international standards and specifications (e.g., ISO, ASTM) for mechanical properties, material composition, and performance under specific simulated conditions (like wear and range of motion). There is no "pathology" or "outcomes data" ground truth directly described for the performance testing in this summary for substantial equivalence.

8. The sample size for the training set

  • Not Applicable. This is a mechanical implant device, not an AI/ML algorithm, so there is no "training set."

9. How the ground truth for the training set was established

  • Not Applicable. No training set exists for this type of device.

{0}------------------------------------------------

October 1, 2019

Image /page/0/Picture/1 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the FDA logo is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.

Zimmer GmbH Neha Sreenath Regulatory Affairs Senior Speicalist Sulzerallee 8 Winterthur, 8404 Ch

Re: K192416

Trade/Device Name: BIOLOX Delta Ceramic Femoral Heads, BIOLOX Option Ceramic Femoral Head System Regulation Number: 21 CFR 888.3353 Regulation Name: Hip Joint Metal/Ceramic/Polymer Semi-Constrained Cemented Or Nonporous Uncemented Prosthesis Regulatory Class: Class II Product Code: LZO Dated: August 30, 2019 Received: September 4, 2019

Dear Neha Sreenath:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpm/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part

{1}------------------------------------------------

801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely.

FOR Vesa Vuniqi Acting Assistant Director DHT6A: Division of Joint Arthroplasty Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Ouality Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

Indications for Use

510(k) Number (if known)

K192416

Device Name

BIOLOX® delta Ceramic Femoral Head

Indications for Use (Describe)

The BIOLOX delta Ceramic Femoral Heads are modular components used in total hip arthroplasty and are indicated for the following:

· Patients suffering from severe hip pain and disability due to rheumatoid arthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur.

· Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis.

• Patients suffering from disability due to previous fusion; patients with previously failed endoprostheses and/or total hip components in the operative extremity.

· Patients with acute femoral neck fractures.

Type of Use (Select one or both, as applicable)

X Prescription Use (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2020 See PRA Statement below.

{3}------------------------------------------------

Form Approved: OMB No. 0910-0120

Expiration Date: 06/30/2020

See PRA Statement below.

DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

Indications for Use

510(k) Number (if known)

K192416

Device Name

BIOLOX® OPTION Ceramic Femoral Head System

Indications for Use (Describe)

The BIOLOX OPTION Ceramic Femoral Head System is comprised of modular components used in primary or revision total hip arthroplasty and is indicated for the following:

· Patients suffering from severe hip pain and disability due to rheumatoid arthritis, traumatic arthritis,

polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur.

  • · Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis.
  • · Patients suffering from disability due to previous fusion.
  • · Patients with previously failed endoprostheses and/or total hip components in the operative extremity.
  • · Patients with acute neck fractures.

Type of Use (Select one or both, as applicable)

X Prescription Use (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff @fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{4}------------------------------------------------

Image /page/4/Picture/1 description: The image shows the logo for Zimmer Biomet. The logo consists of a blue circle with a white "Z" inside, followed by the text "ZIMMER BIOMET" in a sans-serif font. Below the company name is the tagline "Your progress. Our promise."

510(k) SUMMARY

Sponsor:Zimmer GmbHSulzerallee 8, P.O. Box8404 Winterthur, Switzerland
Contact Person:Neha SreenathSenior Specialist, Regulatory AffairsTelephone: +41 58 85 48814Fax: + 41 52 244 86 58
Date:August 30, 2019
Trade Name:BIOLOX® delta Ceramic Femoral HeadBIOLOX® OPTION Ceramic Femoral Head System
Common Name:Ceramic Femoral Head Prosthesis
Classification Product Code :LZO
Device Classification Name:Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer,Cemented Or Non-Porous, UncementedProsthesis, Hip, Semi-Constrained, Metal/Polymer, PorousUncementedProsthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Regulation Number / Description:21 CFR § 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis
Predicate Device:Biolox Delta Ceramic Femoral Heads, manufactured by Zimmer GmbH, K071535, cleared 11/19/2007 and K130899, cleared 05/01/2013Biolox Option Ceramic Femoral Head System, manufactured by Zimmer GmbH, K073567, cleared 03/13/2008
Device Description:The BIOLOX delta Ceramic Femoral Heads are fabricated from analumina matrix composite and are available in diameters of 28, 32,36, and 40mm with a range of offsets to accommodate variouspatient anatomies. They serve as an alternative to both metal andalumina ceramic femoral heads for use in total hip arthroplasty.The BIOLOX OPTION Ceramic Femoral Head System consist of aceramic head fabricated from an alumina matrix compositeavailable in diameters of 28, 32, 36, and 40 mm and a titanium

{5}------------------------------------------------

Image /page/5/Picture/1 description: The image shows the logo for Zimmer Biomet. The logo consists of a blue circle with a stylized "Z" inside, followed by the text "ZIMMER BIOMET" in a sans-serif font. Below the company name is the tagline "Your progress. Our promise."

adapter for the femoral stem cone with a range of offsets to accommodate various patient anatomies. The system serves as an alternative to both metal and alumina ceramic femoral heads and is for use in both primary and revision total hip arthroplasty. Indications for Use: BIOLOX delta Ceramic Femoral Heads: The BIOLOX delta Ceramic Femoral Heads are modular components used in total hip arthroplasty and are indicated for the following: • Patients suffering from severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur. · Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis. · Patients suffering from disability due to previous fusion; patients with previously failed endoprostheses and/or total hip components in the operative extremity. · Patients with acute femoral neck fractures. BIOLOX OPTION Ceramic Femoral Head System: The BIOLOX OPTION Ceramic Femoral Head System is comprised of modular components used in primary or revision total hip arthroplasty and is indicated for the following: • Patients suffering from severe hip pain and disability due to rheumatoid arthritis. osteoarthritis. traumatic arthritis. polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur. · Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis. · Patients suffering from disability due to previous fusion. · Patients with previously failed endoprostheses and/or total hip components in the operative extremity. · Patients with acute neck fractures. Comparison to Predicate Device: The intended use of the modified devices, as described in its labelling, has not changed as a result of the modifications proposed in the present submission. Further, the indications for use, materials, design features and sterilization method of the subject devices remain identical to the predicate devices. The proposed compatibility extension does not alter the fundamental scientific technology shared by both the subject devices and predicate devices. Performance Data (Nonclinical Non-Clinical Performance and Conclusions:

{6}------------------------------------------------

Image /page/6/Picture/1 description: The image shows the logo for Zimmer Biomet. The logo consists of a blue circle with a stylized "Z" inside, followed by the text "ZIMMER BIOMET" in a gray sans-serif font. Below the company name is the tagline "Your progress. Our promise." in a smaller, lighter gray font.

and/or Clinical):Results from engineering analyses demonstrate that the subjectBIOLOX delta and BIOLOX OPTION ceramic femoral heads forwhich the expansion of product compatibility is proposed remainssubstantially equivalent to the predicate devices cleared underK071535 and K130899 (BIOLOX delta) and K073567 (BIOLOXOPTION) respectively. This conclusion has been supported byrationales for wear justification (ISO 7206-2), material equivalence(ISO 6474-2, ISO 5832-3/ASTM F136) and Range of Motionaccording to ISO 21535.Clinical Performance and Conclusions:
Clinical data and conclusions were not needed for this device.
Conclusion:The subject devices have the same intended use and indicationsfor use as the predicate devices. The subject devices use thesame operating principle, incorporate the same basic design andlabelling and are manufactured and sterilized using the samematerials and processes as the predicate devices.
Except for the modifications described in this submission, thesubject devices are identical to the predicate devices, and theperformance data and analyses demonstrate that:• any differences do not raise new questions of safety and
  • effectiveness as established with performance testing; and
  • the subject devices are at least as safe and effective as ● the legally marketed predicate devices.

§ 888.3353 Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

(a)
Identification. A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A12 03 ) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.(b)
Classification. Class II.