(90 days)
The hip prosthesis AMIStem-H, AMIStem-H collared, AMIStem-H Proximal Coating, AMIStem-P and AMIStem-P collared are designed for cementless use in total or partial hip arthroplasty for primary or revision surgery. The hip prosthesis AMIStem-C is designed for cemented use in total or partial hip arthroplasty in primary or revision surgery.
Hip replacement is indicated in the following cases:
· Severely painful and/or disabled joint as a result of arthritis, rheumatoid polyarthritis, or congenital hip dysplasia
- Avascular necrosis of the femoral head
· Acute traumatic fracture of the femoral head or neck
· Failure of previous hip surgery: joint reconstruction, arthrodesis, partial hip arthroplasty, hip resurfacing replacement or total hip arthroplasty.
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are line extensions to the Medacta Total Hip Prosthesis system family AMIStem H, Quadra S and Quadra H femoral stems (K093944), AMIStem C & Quadra C SN (K103189), AMIStem and Quadra - Line Extension (K121011), and AMIStem-H Proximal Coating (K161635).
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants subject of this submission are comprised of the following products:
- AMIStem-H Proximal Coating STD, Stem sizes 00 and 0; ●
- AMIStem-H Proximal Coating LAT, Stem size 0;
- AMIStem-P STD, Stem sizes 00 9; ●
- AMIStem-P LAT, Stem sizes 0 - 8;
- AMIStem-P Collared STD, Stem sizes 00 9; and ●
- AMIStem-P Collared LAT, Stem sizes 0 - 8.
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are part of the brand, Medacta Total Hip Prosthesis system for total and partial hip arthroplasty. The Medacta Total Hip Prosthesis system family consists of femoral stems, modular femoral heads, and acetabular components.
The provided text describes a 510(k) premarket notification for hip joint prostheses, specifically the AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared. It focuses on demonstrating substantial equivalence to predicate devices through a comparison of technological characteristics and performance data.
However, the provided text does not contain any information regarding the acceptance criteria or study details for an artificial intelligence (AI) device. The "Performance Data" section solely lists non-clinical mechanical and pyrogenicity tests for the hip prostheses, which are physical medical devices, not AI software or algorithms.
Therefore, I cannot provide the requested information about acceptance criteria and studies related to an AI device using the provided text.
Here's why I cannot fulfill your request:
- No AI Device Mentioned: The document is a 510(k) submission for physical hip implants, not an AI or software as a medical device (SaMD).
- Performance Data Irrelevant to AI: The performance tests listed (range of motion, fatigue testing, pull-off force, pyrogenicity) are standard for orthopedic implants, not for evaluating AI performance metrics like diagnostic accuracy, sensitivity, specificity, etc.
- Missing AI-Specific Details: All your specific questions (sample size, data provenance, expert ground truth, adjudication, MRMC studies, standalone performance, training set details) are entirely related to AI model evaluation, which is absent from this document.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logos of the U.S. Department of Health & Human Services and the U.S. Food & Drug Administration (FDA). The Department of Health & Human Services logo is on the left, featuring a stylized caduceus. To the right of it is the FDA logo, with the acronym "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG" and "ADMINISTRATION" in blue text.
Medacta International SA % Elizabeth Rose Manager, Regulatory Affairs Mapi USA, Inc. 2343 Alexandria Drive, Suite 100 Lexington, Kentucky 40504
March 14. 2018
Re: K173794
Trade/Device Name: AMIStem-H Proximal Coating, AMIStem-P and AMIStem-P Collared Regulation Number: 21 CFR 888.3353 Regulation Name: Hip Joint Metal/Ceramic/Polymer Semi-Constrained Cemented Or Nonporous Uncemented Prosthesis Regulatory Class: Class II Product Code: LZO, MEH, KWY, LZY, LPH Dated: December 13, 2017 Received: December 14, 2017
Dear Elizabeth Rose:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part
{1}------------------------------------------------
801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
Indications for Use
510(k) Number (if known)
Device Name
AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared
Indications for Use (Describe)
The hip prosthesis AMIStem-H, AMIStem-H collared, AMIStem-H Proximal Coating, AMIStem-P collared are designed for cementless use in total or partial hip arthroplasty for primary or revision surgery. The hip prosthesis AMIStem-C is designed for cemented use in total or partial hip arthroplasty in primary or revision surgery.
Hip replacement is indicated in the following cases:
· Severely painful and/or disabled joint as a result of arthritis, rheumatoid polyarthritis, or congenital hip dysplasia
- Avascular necrosis of the femoral head
· Acute traumatic fracture of the femoral head or neck
· Failure of previous hip surgery: joint reconstruction, arthrodesis, partial hip arthroplasty, hip resurfacing replacement or total hip arthroplasty.
| Type of Use (Select one or both, as applicable) |
|---|
| ------------------------------------------------- |
X Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
3.0 510(k) Summary
I. Submitter
Medacta International SA Strada Regina 6874 Castel San Pietro (CH) Switzerland Phone (+41) 91 696 60 60 Fax (+41) 91 696 60 66
Contact Person: Stefano Baj, Regulatory Affairs Manager, Medacta International SA Date Prepared: December 13, 2017 Date Revised: March 9, 2018
II. Device
| Device Proprietary Name: | AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared |
|---|---|
| Common or Usual Name: | Femoral Stems |
| Classification Name: | Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis |
| Primary Product Code: | LZO, MEH, KWY, LZY, LPH |
| Regulation Number: | 21 CFR 888.3353, 21 CFR 888.3390, 21 CFR 888.3360, 21 CFR 888.3358 |
| Device Classification | II |
III. Predicate Device
Substantial equivalence is claimed to the following devices:
- Medacta Total Hip Prosthesis AMIStem H, Quadra S and Quadra H femoral stems, ● K093944, Medacta International SA
- AMIStem and Quadra - Line Extension, K121011, Medacta International SA
- AMIStem-H Proximal Coating, K161635, Medacta International SA
IV. Device Description
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are line extensions to the Medacta Total Hip Prosthesis system family AMIStem H, Quadra S and
{4}------------------------------------------------
Quadra H femoral stems (K093944), AMIStem C & Quadra C SN (K103189), AMIStem and Quadra - Line Extension (K121011), and AMIStem-H Proximal Coating (K161635).
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants subject of this submission are comprised of the following products:
- AMIStem-H Proximal Coating STD, Stem sizes 00 and 0; ●
- AMIStem-H Proximal Coating LAT, Stem size 0;
- AMIStem-P STD, Stem sizes 00 9; ●
- AMIStem-P LAT, Stem sizes 0 - 8;
- AMIStem-P Collared STD, Stem sizes 00 9; and ●
- AMIStem-P Collared LAT, Stem sizes 0 - 8.
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are part of the brand, Medacta Total Hip Prosthesis system for total and partial hip arthroplasty. The Medacta Total Hip Prosthesis system family consists of femoral stems, modular femoral heads, and acetabular components.
V. Indications for Use
The hip prosthesis AMIStem-H, AMIStem-H collared, AMIStem-H Proximal Coating, AMIStem-P and AMIStem-P collared are designed for cementless use in total or partial hip arthroplasty for primary or revision surgery. The hip prosthesis AMIStem-C is designed for cemented use in total or partial hip arthroplasty in primary or revision surgery.
Hip replacement is indicated in the following cases:
• Severely painful and/or disabled joint as a result of arthrosis, traumatic arthritis, rheumatoid polyarthritis, or congenital hip dysplasia
- · Avascular necrosis of the femoral head
- · Acute traumatic fracture of the femoral head or neck
· Failure of previous hip surgery: joint reconstruction, internal fixation, arthrodesis, partial hip arthroplasty, hip resurfacing replacement or total hip arthroplasty.
{5}------------------------------------------------
VI. Comparison of Technological Characteristics
The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants and the predicate devices share the following characteristics:
- sizes;
- stem lengths;
- CCD angle;
- cementless;
- material of construction; ●
- coatings;
- coating composition of the AMIStem-H Proximal Coating only;
- biocompatibility;
- device usage;
- sterility:
- o shelf life; and
- packaging.
The only technological characteristic difference between the AMIStem-H proximal Coating and the predicate devices is the addition of three new sizes STD 00, 0 and LAT 0.
The only technological characteristic difference between the AMIStem-P and AMIStem-P Collared implants and the predicate devices is the coating composition. The AMIStem-P and AMIStem-P Collared implants have a double coating of Ti and HA in the proximal zone of the shaft and a HA coated distal end.
VII. Performance Data
Testing was conducted according to written protocols with acceptance criteria that were based on standards. The following mechanical studies were performed in support of a substantial equivalence determination:
Non-Clinical Studies
- Performance Tests 0
- о range of motion (ROM): EN ISO 21535:2009 Non-Active Surgical Implants - Joint Replacement Implants - Specific Requirements for Hip-Joint Replacement Implants (ISO 21535:2007/Amendment 1:2016);
- fatigue testing: ISO 7206-4 Third Edition 2010-06-15 Implants For Surgery о Partial And Total Hip Joint Prostheses - Part 4: Determination Of Endurance Properties And Performance Of Stemmed Femoral Components [Including AMENDMENT 1 (2016)];
- fatigue testing: ISO 7206-6 Second Edition 2013-11-15 Implants For Surgery o - Partial And Total Hip Joint Prostheses - Part 6: Determination Of Endurance Properties Of Head And Neck Region Of Stemmed Femoral Components; and
{6}------------------------------------------------
- o pull off force testing: ASTM F2009-00 (Reapproved 2011) Standard Test Method For Determining The Axial Disassembly Force Of Taper Connections Of Modular Prostheses.
- Pyrogenicity
- Bacterial Endotoxin Test (LAL test) was conducted and met the endotoxin o limit of <20 EU/device; and
- Medacta has no intentions of labeling the subject devices as non-pyrogenic or o pyrogen free.
VIII. Conclusion
Based on the above information, the AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are substantially equivalent to the identified predicate devices.
Substantial equivalence has been demonstrated through a comparison of intended use, design, and technological characteristics, as well as performance evaluations. The AMIStem-H Proximal Coating, AMIStem-P, and AMIStem-P Collared implants are as safe and effective as the predicate devices. Medacta Total Hip Prosthesis – AMIStem H. Quadra H femoral stems (K093944), AMIStem and Quadra - Line Extension (K121011), and AMIStem-H Proximal Coating (K161635).
--------------------------This space intentionally left blank-----------------------------------------------------------------------------------------------------------------
N/A