K Number
K172694

Validate with FDA (Live)

Date Cleared
2018-07-06

(302 days)

Product Code
Regulation Number
870.1650
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Sterile Disposable Syringes are intended for the injection of contrast media or saline, they shall be used with an U.S legally marketed angiographic injector.

Device Description

The proposed devices are available in packs, which may include different configuration of syringes and accessories. The syringes are plastic, disposable syringes, which are available in various models and configurations. They are intended to be used with an U.S legally marketed angiography injector, compatibilities are shown in Table 1. The connecting tubes, which is used to connect the syringe and the catheter. The tubes are available in three configurations, which are straight tube, Type T tube and spiral tube. The different between these tubes is tube shape, which is available in straight shape for straight tube, spiral shape for spiral tube and T shape for T tube. The Type T tube is available in a various specifications to connect different model of syringe. J shape tube, which is used to draw contrast media/ saline into the syringe barrel. Spikes, which are used to draw contrast media/saline into the syringe barrel.

AI/ML Overview

This document is a 510(k) Summary for Sterile Disposable Syringes, which is a regulatory submission to the FDA. It details the device, its intended use, and non-clinical testing performed to establish substantial equivalence to a predicate device. It specifically states: "No clinical study is included in this submission."

Therefore, the following information about acceptance criteria and studies to meet them cannot be provided from the given text:

  1. A table of acceptance criteria and the reported device performance: While the document lists various non-clinical tests and standards (e.g., ISO 7886-2, ISO 594-1, ISO 594-2), it does not explicitly state numerical acceptance criteria for these tests or specific reported device performance results in a comparative table for a clinical study. It only states that the device "complies with the following standards" and that “non clinical tests were conducted to verify that the proposed device met all design specifications”. For biocompatibility, it states "No cytotoxicity," "No intracutaneous reactivity," etc., which can be considered performance relative to certain criteria.

  2. Sample sized used for the test set and the data provenance: No clinical test set.

  3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable as there is no clinical test set/study.

  4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable as there is no clinical test set/study.

  5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is a medical device (syringes) and not an AI-assisted diagnostic tool.

  6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done: Not applicable. This is a medical device (syringes) and not an algorithm.

  7. The type of ground truth used (expert consensus, pathology, outcomes data, etc): Not applicable as there is no clinical test set/study. The ground truth for the non-clinical tests would be the established specifications and standards (e.g., ISO for sterility, gauging, leakage).

  8. The sample size for the training set: Not applicable as there is no clinical study or algorithm that requires a training set. The device is a physical product (syringes).

  9. How the ground truth for the training set was established: Not applicable as there is no clinical study or algorithm that requires a training set.

Summary of available information regarding non-clinical acceptance and performance:

The non-clinical tests performed on the proposed device (Sterile Disposable Syringes) were conducted to verify that it met all design specifications and was Substantially Equivalent (SE) to the predicate device (ANT Angiographic Syringes K072696).

The tests and their compliance statements are:

Test/CharacteristicStandard/DescriptionReported Device Performance/Compliance Statement
CleanlinessClause 5 of ISO 7886-2:1996Complies with standard
Limits for acidity/alkalinityClause 6 of ISO 7886-2:1996Complies with standard
Limits for extractable metalsClause 7 of ISO 7886-2:1996Complies with standard
LubricantClause 8 of ISO 7886-2:1996Complies with standard
Tolerance on graduated capacityClause 9 of ISO 7886-2:1996Complies with standard
Graduated scaleClause 10 of ISO 7886-2:1996Complies with standard
BarrelClause 11 of ISO 7886-2:1996Complies with standard
Piston/plunger assemblyClause 12 of ISO 7886-2:1996Complies with standard
NozzleClause 13 of ISO 7886-2:1996Complies with standard
PerformanceClause 14 of ISO 7886-2:1996Complies with standard
GaugingClause 4.1 of ISO 594-1:1986Complies with standard
Liquid leakageClause 4.2 of ISO 594-1:1986Complies with standard
Air leakageClause 4.3 of ISO 594-1:1986Complies with standard
Separation forceClause 4.4 of ISO 594-1:1986Complies with standard
Stress crackingClause 4.5 of ISO 594-1:1986Complies with standard
GaugingClause 4.1 of ISO 594-2:1998Complies with standard
LeakageClause 4.2 of ISO 594-2:1998Complies with standard
Separation forceClause 4.3 of ISO 594-2:1998Complies with standard
Unscrewing torqueClause 4.4 of ISO 594-2:1998Complies with standard
Ease of assemblyClause 4.5 of ISO 594-2:1998Complies with standard
Resistance to overridingClause 4.6 of ISO 594-2:1998Complies with standard
Stress crackingClause 4.7 of ISO 594-2:1998Complies with standard
Seal strength (Packaging)ASTM F88/F88-09Complies with standard
Dye penetration (Packaging)ASTM F1929-12Complies with standard
EO residueISO 10993-7:2008Complies with standard
ECH residueISO 10993-7:2008Complies with standard
Bacteria Endotoxin LimitUSP 38-NF 33 <85>Complies with standard
Shelf Life EvaluationPhysical, Mechanical, Chemical, Package TestPerformed on aging samples to verify the claimed shelf life of the device
CytotoxicityISO 10993-5No cytotoxicity
Skin SensitizationISO 10993-10No skin sensitization
Intracutaneous ReactivityISO 10993-10No intracutaneous reactivity
Acute Systemic ToxicityISO 10993-11No systemic toxicity
Hemolytic PropertyASTM F756No hemolysis
PyrogenISO 10993-11No pyrogen
Complement ActivityISO 10993-4No complement

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logos of the Department of Health and Human Services and the Food and Drug Administration (FDA). The Department of Health and Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.

July 6, 2018

Shenyang MasTech Medical Device Co., Ltd. % Diana Hong General Manager Mid-Link Consulting Co.,Ltd P.O.box 120-119 Shanghai, 200120 CN

Re: K172694

Trade/Device Name: Sterile Disposable Syringes Regulation Number: 21 CFR 870.1650 Regulation Name: Angiographic Injector and Syringe Regulatory Class: Class II Product Code: DXT Dated: May 31, 2018 Received: June 5, 2018

Dear Diana Hong:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820);

{1}------------------------------------------------

and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely.

Michael John -S 2018.07.06 11:58:42 -04'00'

for Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Indications for Use

510(k) Number (if known)

K172694

Device Name Sterile Disposable Syringes

Indications for Use (Describe)

The Sterile Disposable Syringes are intended for the injection of contrast media or saline, they shall be used with an U.S legally marketed angiographic injector.

Type of Use (Select one or both, as applicable)

X Prescription Use (Part 21 CFR 801 Subpart D)

| | Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Exhibit #10 510(k) Summary

This 510(k) Summary is being submitted in accordance with requirements of Title 21, CFR Section 807.92.

The assigned 510(k) Number: K172694

    1. Date of Preparation: 05/29/2018
    1. Sponsor Identification

Shenyang MasTech Medical Device Co., Ltd. Zhaojia Village, Qianjin Street, Dadong District, Shenyang 110165, China

Establishment Registration Number: Not yet registered

Contact Person: Liu Han Position: General Manager Tel: +86-24-24331351 Fax: +86-24-24326101 Email: sy@mastech-medical.com

    1. Designated Submission Correspondent
      Ms. Diana Hong (Primary Contact Person) Ms. Ying Xu (Alternative Contact Person)

Mid-Link Consulting Co., Ltd

P.O. Box 120-119, Shanghai, 200120, China

Tel: +86-21-22815850, Fax: 240-238-7587 Email: info@mid-link.net

{4}------------------------------------------------

4. Identification of Proposed Device

Trade Name: Sterile Disposable Syringes Common Name: Disposable angiographic syringe

Regulatory Information

Classification Name: Angiographic injector and syringe; Classification: II; Product Code: DXT Regulation Number: CFR 870.1650 Review Panel: Cardiovascular

Intended Use Statement:

The Sterile Disposable Syringes are intended for the injection of contrast media or saline, they shall be used with an US legally marketed angiographic injector.

Device Description

The proposed devices are available in packs, which may include different configuration of syringes and accessories. The syringes are plastic, disposable syringes, which are available in various models and configurations. They are intended to be used with an U.S legally marketed angiography injector, compatibilities are shown in Table 1.

Model (Syringe)Volume (ml)TypeK Number of Compatible Angiographic Injector
DSA-150-MARK150mlSingle shotK903390
DSA-150-LF150mlSingle shotK860204
DSA-130-NE125mlSingle shotK092896
CT/DSA-150-LF150mlSingle shotK963071, K873687
CT-200-MARK200mlSingle shotK993728, K991557, K982814, K934086, K924116, K913624
CT-200-MARK-E200mlSingle shotK071378, K063029, K011160
CT-200/200-MARK-E200/200mlDual shootK071378, K063029, K031571
CT-200-LF200mlSingle shotK912944
CT-100-NE100mlSingle shotK133189, K071691, K062168, K052633
CT-200-NE200mlSingle shotK133189, K071691, K062168,

Table 1 Compatibility between Syringes and Injectors

{5}------------------------------------------------

K052633
CT/MRI-60-NE50mlSingle shotK133189, K091734 (MRI),K071691, K062168, K052633
MRI-60-LF60/60mlDual shootK073592, K984088
MRI-60-MARK65/65mlDual shootK011991, K935668
MRI-100-MARK65/115mlDual shootK042784, K033247, K012950
MRI-100-EZEM100/100mlDual shootK020892

The connecting tubes, which is used to connect the syringe and the catheter. The tubes are available in three configurations, which are straight tube, Type T tube and spiral tube. The different between these tubes is tube shape, which is available in straight shape for straight tube, spiral shape for spiral tube and T shape for T tube. The Type T tube is available in a various specifications to connect different model of syringe.

J shape tube, which is used to draw contrast media/ saline into the syringe barrel.

Spikes, which are used to draw contrast media/saline into the syringe barrel.

  • న్. Identification of Predicate Device
    510(k) Number: K072696 Product Name: ANT Angiographic Syringes Manufacturer: Shenzhen Ant Hi-Tech Industrial Co., Ltd.

6. Non-Clinical Test Conclusion

Non clinical tests were conducted to verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device. The test results demonstrated that the proposed device complies with the following standards:

CleanlinessClause 5 of ISO 7886-2:1996
Limits for acidity or alkalinityClause 6 of ISO 7886-2:1996
Limits for extractable metalsClause 7 of ISO 7886-2:1996
LubricantClause 8 of ISO 7886-2:1996
Tolerance on graduated capacityClause 9 of ISO 7886-2:1996
Graduated scaleClause 10 of ISO 7886-2:1996
BarrelClause 11 of ISO 7886-2:1996
Piston/ plunger assemblyClause 12 of ISO 7886-2:1996
NozzleClause 13 of ISO 7886-2:1996
PerformanceClause 14 of ISO 7886-2:1996

{6}------------------------------------------------

GaugingClause 4.1 of ISO 594-1:1986
Liquid leakageClause 4.2 of ISO 594-1:1986
Air leakageClause 4.3 of ISO 594-1:1986
Separation forceClause 4.4 of ISO 594-1:1986
Stress crackingClause 4.5 of ISO 594-1:1986
GaugingClause 4.1 of ISO 594-2:1998
LeakageClause 4.2 of ISO 594-2:1998
Separation forceClause 4.3 of ISO 594-2:1998
Unscrewing torqueClause 4.4 of ISO 594-2:1998
Ease of assemblyClause 4.5 of ISO 594-2:1998
Resistance to overridingClause 4.6 of ISO 594-2:1998
Stress crackingClause 4.7 of ISO 594-2:1998

Sterile Barrier Packaging Testing performed on the proposed device:

Seal strengthASTM F88/F88-09
Dye penetrationASTM F1929-12

Sterilization and Shelf Life Testing performed on the proposed device:

EO residueISO 10993-7:2008
ECH residueISO 10993-7:2008
Bacteria Endotoxin LimitUSP 38-NF 33 <85>
Shelf Life EvaluationPhysical, Mechanical, Chemical, Package Test
were performed on aging samples to verify the
claimed shelf life of the device

Biocompatibility Testing:

The patient-contact materials of proposed devices are identified and the proposed devices were tested for Cytotoxicity (ISO 10993-5), Skin Sensitization (ISO 10993-10), Intracutaneous Reactivity (ISO 10993-10), Acute Systemic Toxicity (ISO 10993-11), Hemolytic Property (ASTM F756), Pyrogen (ISO 10993-11) and Complement Activity (ISO 10993-4).

    1. Clinical Test Conclusion
      No clinical study is included in this submission.

{7}------------------------------------------------

Substantially Equivalent (SE) Comparison 8.

Table 1 Comparison of Technology Characteristics

ItemProposed DevicePredicate DeviceK072696
Product CodeDXTDXT
RegulationNumberCFR 870.1650CFR 870.1650
Intended UseThe Sterile Disposable Syringes are intended for the injection of contrastmedia or saline, they shall be used with an U.S legally marketedangiographic injector.ANT Angiographic Syringes are syringes for the injection of contrasmedia or saline. This syringe is for single use with U.S leally marketecangiographic injection.
Operation modePower-driven operation, single usePower-driven operation, single use
Configurationand MaterialAngiographicSyringeConfigurationMaterialAngiographicSyringeConfigurationMaterial
BarrelPolycarbonate (PC) orPolypropylene (PP)BarrelPolypropylene (PP) orPolyethylene terephthalate (PET)
PistonNatural RubberPistonUnknown
Piston SeatPolycarbonate (PC) orPolypropylene (PP)Piston SeatUnknown
Protective CapPolypropylene (PP)Protective CapUnknown
ConnectingtubeTubingPolyvinyl Chloride (PVC)Connectingtube
Check ValvePolycarbonate (PC)
J shape tubePolyethylene (PE)J shape tubeUnknown
SpikeAcrylonitrile-butadiene-styrene (ABS)SpikeUnknown
SterilityEO SterilizedEO Sterilized
Single UseYesYes

S001

{8}------------------------------------------------

BiocompatibilityCytotoxicityNo cytotoxicity.CytotoxicityNo cytotoxicity.
IrritationNo intracutaneous reactivity.IrritationNo intracutaneous reactivity.
SensitizationNo skin sensitizationSensitizationNo skin sensitization
Systemic ToxicityNo systemic toxicitySystemic ToxicityNo systemic toxicity
HemolysisNo hemolysisHemolysisNo hemolysis
PyrogenNo pyrogenPyrogenNo pyrogen
Complement ActivationNo complementComplement ActivationNo complement
PerformanceComply with ISO 7886-2, ISO594-1 and ISO 594-2Comply with ISO 7886-2, ISO594-1 and ISO 594-2

Substantially Equivalent (SE) Conclusion 9.

Based on the comparison and analysis above, the proposed devices are determined to be Substantially Equivalent (SE) to the predicate device.

S001

§ 870.1650 Angiographic injector and syringe.

(a)
Identification. An angiographic injector and syringe is a device that consists of a syringe and a high-pressure injector which are used to inject contrast material into the heart, great vessels, and coronary arteries to study the heart and vessels by x-ray photography.(b)
Classification. Class II (special controls). The device, when it is a non-patient contacting balloon inflation syringe intended only to inflate/deflate balloon catheters and monitor pressure within the balloon, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.