K Number
K160411

Validate with FDA (Live)

Date Cleared
2016-07-25

(160 days)

Product Code
Regulation Number
880.6250
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

Device Description

The proposed device is a disposable device intended for over the counter use. It is not made with natural rubber latex. Instead, the gloves are formulated using vinyl synthetic polymer. The glove is coated with an emollient coating. The gloves are manufactured using molds that are ambidextrous. They are offered powder-free and non-sterile.

AI/ML Overview

The provided document describes the acceptance criteria and performance data for the Cardinal Health™ Vinyl Powder-Free Exam Gloves with Neu-Thera® Coating. This is a medical device application for examination gloves, and therefore the "device" in this context refers to these gloves.

Here's an analysis of the acceptance criteria and the study that proves the device meets them:

1. Table of Acceptance Criteria and the Reported Device Performance

CharacteristicAcceptance CriteriaReported Device Performance
Biocompatibility
Primary Skin IrritationNon-irritating (per ISO 10993-10)Non-irritating
Guinea Pig MaximizationNon-sensitizing (per ISO 10993-10)Non-sensitizing
Physical Characteristics
DimensionsMeets ASTM D5250 requirementsMeets requirements
Physical PropertiesMeets ASTM D5250 requirements for vinyl examination glovesMeets requirements
Freedom from HolesMeets 21 CFR 800.20 & ASTM D5250 requirements of AQL 2.5Tested in accordance with ASTM D 5151 with acceptable results; Meets requirements of AQL 2.5
Powder ResidualMeets requirements of ≤2.0 mg/glove for "Powder-Free" designation per ASTM D5250Gloves meet powder level requirements for "Powder-Free" designation per ASTM D5250. Results generated values < 2mg of residual powder per glove.

2. Sample Size Used for the Test Set and the Data Provenance

The document does not explicitly state the sample size for each specific test mentioned (e.g., how many gloves were tested for freedom from holes or powder residual). It refers to compliance with ISO and ASTM standards, which would define appropriate sample sizes for these types of tests.

The data provenance is from non-clinical tests conducted by Cardinal Health, Inc. This is prospective testing performed on the device itself. There is no information regarding country of origin for the data beyond being submitted by a US-based company for FDA approval in the US.

3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

This information is not applicable in this context. The "ground truth" for a medical device like examination gloves is typically established through adherence to recognized international and national consensus standards (like ISO and ASTM) and regulatory requirements (like 21 CFR). These standards define objective, measurable performance criteria. Expert judgment, while informing the development of such standards, is not directly applied on a case-by-case basis to "establish ground truth" for individual glove performance during testing in the way it would be for, say, image interpretation in AI.

4. Adjudication Method for the Test Set

This is not applicable. Adjudication methods like 2+1 or 3+1 are typically used when there's subjective interpretation involved, such as in clinical trials or when establishing ground truth from multiple expert readings. For objective physical and chemical tests of a medical device like gloves, the results are derived directly from the test methods and interpreted against the defined criteria in the standards.

5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs without AI Assistance

This is not applicable. An MRMC comparative effectiveness study is relevant for AI-powered diagnostic devices or tools that assist human interpreters (e.g., radiologists interpreting images). The device in question is an examination glove, which does not involve human "readers" or AI assistance in this manner.

6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

This is not applicable. This question pertains to AI/algorithm performance. The device is a physical product (gloves) and does not involve any algorithms.

7. The Type of Ground Truth Used

The ground truth used for these tests is based on accepted international and national consensus standards and regulatory requirements. Specifically:

  • Biocompatibility: ISO 10993-10 standards.
  • Physical Characteristics (Dimensions, Physical Properties, Freedom from Holes, Powder Residual): ASTM D5250, ASTM D5151, ASTM D6124, and 21 CFR 800.20.

These standards define the objective performance benchmarks that the gloves must meet.

8. The Sample Size for the Training Set

This is not applicable. This question refers to the training of an AI model. The device (examination gloves) does not utilize a training set in the context of machine learning.

9. How the Ground Truth for the Training Set Was Established

This is not applicable for the same reasons as point 8.

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is an emblem featuring a stylized depiction of three human profiles facing right, with flowing lines suggesting movement or connection.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

July 25, 2016

Cardinal Health, Inc. Megan Middaugh Manager, Regulatory Affairs 1500 Waukegan Road Waukegan, IL 60085

Re: K160411

Trade/Device Name: Cardinal Health™ Vinyl Powder-Free Exam Gloves with Neu-Thera® Coating (Esteem® Synthetic with Neu-Thera®) Regulation Number: 21 CFR 880.6250 Regulation Name: Patient Examination Glove Regulatory Class: I Product Code: LYZ Dated: June 13, 2016 Received: June 14, 2016

Dear Ms. Middaugh:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act

{1}------------------------------------------------

or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

Tejashri Purohit-Sheth, M.D.

Tejashri Purohit-Sheth, M.D. Clinical Deputy Director DAGRID/ODE/CDRH FOR

Erin I. Keith, M.S. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Indications for Use

510(k) Number (if known) K160411

Device Name

Cardinal Health™ Vinyl Powder-Free Exam Gloves with Neu- thera® Coating (Esteem® Synthetic with Neu-Thera®)

Indications for Use (Describe)

A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

Type of Use (Select one or both, as applicable)
-------------------------------------------------

Prescription Use (Part 21 CFR 801 Subpart D)

|X | Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows the logo for Cardinal Health. The logo consists of a stylized red bird-like design above the company name. The company name "CardinalHealth" is written in a bold, sans-serif font, with "Cardinal" in black and "Health" in a slightly darker shade of black.

Cardinal Health 1500 Waukegan Road Waukegan, IL 60085 cardinalhealth.com

Page 1 of 5

510(k) SUMMARY

Cardinal Health™ Vinyl Powder-Free Exam Gloves with Neu-thera® Coating (Esteem® Synthetic with Neu-Thera®)

Manufacturer:Cardinal Health 200, LLC1500 Waukegan RoadWaukegan, IL 60085
Regulatory Affairs Contact:Megan Middaugh1500 Waukegan RoadWaukegan, IL 60085
Telephone Number:(847) 887-6812
Fax Number:(847) 887-2461
Date Summary Prepared:July 14, 2016
Product Trade Name:Cardinal Health™ Vinyl Powder-Free Exam Gloves with NeuThera® Coating (Esteem® Synthetic with Neu-Thera®)
Common Name:Examination Gloves
Classification Name:Patient Examination Gloves
Classification Panel:General Hospital and Personal Use Devices
Regulation:21 CFR 880.6250
Product Code:LYZ

{4}------------------------------------------------

Page 2 of _5

Image /page/4/Picture/1 description: The image shows the Cardinal Health logo. The logo consists of a stylized red graphic above the company name. The graphic is composed of several curved lines that resemble a bird in flight. The company name, "CardinalHealth," is written in a bold, sans-serif font, with "Cardinal" in regular weight and "Health" in bold.

510(K) SUMMARY (CONT'D)

Predicate Devices:K052568 - Cardinal Health's Esteem Stretchy Synthetic with Neu-Thera® Powder-Free Exam Gloves
Reason for 510(k) Submission:Modification of a legally marketed device
Device Description:The proposed device is a disposable device intended for over the counter use. It is not made with natural rubber latex. Instead, the gloves are formulated using vinyl synthetic polymer. The glove is coated with an emollient coating. The gloves are manufactured using molds that are ambidextrous. They are offered powder-free and non-sterile.
Intended Use:A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.
Substantial Equivalence:The proposed device is substantially equivalent to the predicate device identified in this 510(k) summary. Substantial equivalence can be established in regard to intended use, physical properties and characteristics, design and product features. Both gloves are made of synthetic vinyl using the same manufacturing process.

{5}------------------------------------------------

Table 1: Summary of Technological Characteristics

Summary of the technological characteristics of the device compared to the predicate device
CharacteristicSubject DevicePredicate Device
MaterialCompositionCardinal Health™ Vinyl Powder-FreeExam Gloves with Neu-Thera® Coating(Esteem® Synthetic with Neu-Thera®)Cardinal Health's Esteem StretchySynthetic with Neu-Thera® Powder-Free Exam Gloves (K052568)
MaterialCompositionVinylCoated with emollient coatingVinylCoated with emollient coating
DesignAmbidextrousBeaded cuffLubricatedAmbidextrousBeaded cuffLubricated
Intended UseA patient examination glove is adisposable device intended for medicalpurposes that is worn on the examiner'shand or finger to prevent contaminationbetween patient and examiner.A patient examination glove is adisposable device intended for medicalpurposes that is worn on the examiner'shand or finger to prevent contaminationbetween patient and examiner.
Label ClaimsSingle Use OnlyNon-sterilePowder-freeNot made with natural rubber latexCoated with proprietary formulationSingle Use OnlyNon-sterilePowder-freeNot made with natural rubber latexCoated with proprietary formulation
Dimensions &PhysicalPropertiesMeets ASTM D5250Meets ASTM D5250
Freedom fromHolesMeets 21CFR 800.20 & ASTM D5250requirements of AQL 2.5Meets 21CFR 800.20 & ASTM D5250requirements of AQL 2.5
Powder ResidualMeets requirements of ≤2.0 mg/glove forPowder-Free designation per ASTMD5250Meets requirements of ≤2.0 mg/glovefor Powder-Free designation per ASTMD5250

{6}------------------------------------------------

Table 2: Summary of Non-Clinical Tests

PERFORMANCE DATA
SUMMARY OF NON-CLINICAL TESTS CONDUCTED FOR DETERMINATION
OF SUBSTANTIAL EQUIVALENCEPerformance Test Summary-New Device
CharacteristicStandard/Test/FDAGuidanceResults Summary
Biocompatibility:
Primary SkinIrritationISO 10993-10Non-irritating
Guinea PigMaximizationISO 10993-10Non-sensitizing
Physical Characteristics:
DimensionsASTM D5250Meets requirements
Physical PropertiesASTM D5250Meet requirements for vinyl examinationgloves
Freedom from Holes21 CFR 800.20 &ASTM D5250Tested in accordance with ASTM D 5151with acceptable results; Meetsrequirements of AQL 2.5
Powder ResidualASTM D5250 testedusing ASTMstandard D6124Gloves meet powder level requirements for"Powder-Free" designation per ASTMD5250. Results generated values < 2mg ofresidual powder per glove.

{7}------------------------------------------------

Table 3: Summary of Comparative Performance

Comparative Performance Information Summary
CharacteristicRequirementSubject DevicePredicate Device
Biocompatibility:ISO 10993-1Cardinal Health™ VinylPowder-Free Exam Gloves withNeu-Thera® Coating (Esteem®Synthetic with Neu-Thera®)Cardinal Health's EsteemStretchy Synthetic with Neu-Thera® Powder-Free ExamGloves (K052568)
Primary Skin IrritationISO 10993-10Non-irritatingNon-irritating
Guinea Pig MaximizationISO 10993-10Non-sensitizingNon-sensitizing
DimensionsASTM D5250Meets requirementsMeets requirements
Physical PropertiesASTM D5250Meets requirementsMeets requirements
Freedom from Holes21CFR800.20,ASTM D5250Meets requirementsMeets requirements
Powder ResidualASTM D5250Meets requirementsMeets requirements

SUMMARY OF CLINICAL TESTS CONDUCTED FOR DETERMINATION OF SUBSTANTIAL EQUIVALENCE AND/OR OF CLINICAL INFORMATION

Clinical data is not required.

CONCLUSIONS DRAWN FROM NON-CLINICAL DATA

Non-clinical data demonstrates Cardinal Health™ Vinyl Powder-Free Exam Gloves with Neu-Thera® Coating (Esteem® Synthetic with Neu-Thera®) meet the technological characteristics of ASTM D5250 standard, and are as safe, as effective, and performed as well as the legally marketed devices identified in this summary.

§ 880.6250 Non-powdered patient examination glove.

(a)
Identification. A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.(b)
Classification. Class I (general controls). The device, when it is a finger cot, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.