K Number
K153229

Validate with FDA (Live)

Device Name
Superbium
Manufacturer
Date Cleared
2016-04-12

(158 days)

Product Code
Regulation Number
878.4810
Age Range
All
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Nd: Yag 1064 Laser Handpiece (Long Pulsed) is intended for:
-treatment of benign vascular lesions such as but not limited to port wine stains, hemangiomas, telangiectasias, rosacea. venus lake, facial and leg veins;
-treatment of benign pigmented lesions such as, but not limited to, senile lentigines (age spots), solar lentigos (sun spots), pigmented seborrheic keratoses, nevi, chloasma, cafe-au-lait macules, and plaques;
-tattoos (significant reduction in the intensity of black and/or blue-black tattoos);
verrucae, skin tags, seborrheic keratosis;

  • reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar;
  • coagulation and hemostasis of soft tissue;
    -the removal of unwanted hair for skin types I-VI, and to effect stable long-term permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

The Nd: Yag 1064 Laser Handpiece (Short Pulsed) is intended for:
Removal of tattoos and blemishes of the skin, the treatment of various pigmentation lesions
Laser skin treatment procedures for the treatment of: Acne scars, Wrinkles

The Nd:YAG Q-Switched Handpieces (1064 nm) are indicated for treatment of:

  • Benign vascular lesions such as, but not limited to treatment of:
    Port wine stains; Hemangiomas; Warts; Superficial and deep telangiectasias; Reticular veins (0.1-4.0 mm dia.) of the leg; Rosacea; Venus lake; Leg veins; Spider veins; Poikiloderma of Civatte; Angiomas
    -Benign cutaneous lesions, such as, but not limited to:
    Warts; Scars; Striae; Psoriasis
    -Benign pigmented lesions such as, but not limited to:
    Lentigos (age spots); Solar lentigos (sun spots); Cafe-au-lait macules; Seborrheic keratoses; Nevi and nevus of Ota; Chloasma; Verrucae; Skin tags; Keratoses; The removal of black, blue or green tattoos (significant reduction in the intensity of black and /or blue/black tattoos); Plaques
  • Pigmented benign lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments.
  • The non-ablative treatment of facial wrinkles, such as, but not limited to:
    Periocular wrinkles; Perioral wrinkles;
    -Laser skin resurfacing procedures for the treatment of:
    Acne scars; Wrinkles
  • Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar.
  • Indicated for use on all skin types (Fitzpatrick I-VI), including tanned skin.

The Nd:YAG Q-Switched Handpieces (532 nm) are indicated for treatment of:

  • Incision, excision, ablation, vaporization of soft tissue.
  • Tattoo removal: Light blue; Yellow; Red; Green
  • Vascular lesions: Hemangiomas (Port wine stains/birthmarks, cavernous, cherry, spider, hemangiomas); Angiomas (cherry, spider); Telangiectasia; Spider nevi
    -Benign pigmented lesions: Cafe-au-lait (macules); Lentigines (senile and solar); Freckles (ephelides); Chloasma; Nevi; Nevus spillus; Nevus of Ota ;Becker's Nevi
    -Other benign pigmented cutaneous lesions: Verrucae; Skin tags; Keratoses; Plaques

The 2940 nm Er:YAG Laser Module handpiece is indicated for:
Coagulation, vaporization, ablation or cutting of soft tissue (skin) in Dermatology, Plastic Surgery, ENT, Gynecology, General Surgery, Podiatry and Ophthalmology (skin around the eyes). Laser skin resurfacing procedures for the treatment of:
A. Acne scars

  • Acne scars . . Wrinkles

The 2940 nm Er: Yag Fractional tips are indicated for:
Use in soft tissue (skin, cutaneous tissue, subcutaneous tissue, striated and smooth tissue, muscle, cartilage meniscus, mucous membrane, lymph vessels and nodes; organs, and glands) such as, but not limited to: Dermatology and plastic Surgery: Skin resurfacing Treatment of wrinkles; Epidermal nevi; Telangiectasia; Spider veins; Actinic chelitis; Keloids; Verrucae; Skin tags; Keratoses; Scar revision (including acne scars).

The 1540 Fractional Non-ablative Laser Handpiece is intended for use in coagulation of soft tissue, skin resurfacing procedures as well as treatment of melasma, striae, acne scars and surgical scars.

IPL 400-1200 run handpiece is indicated for:
· The treatment of moderate inflammatory acne vulgaris.
· The treatment of benign pigmented epidermal lesions including dyschromia,
hyperpigmentation, melasma, and ephelides (freckles).
· The treatment of benign cutaneous lesions including warts, scars and striae.
· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.
·Use on all skin types (Fitzpatrick I-VI).

IPL500-1200 nm handpiece is indicated for:
· The treatment of moderate inflammatory acne (acne vulgaris).
· The treatment of tattoos and benign pigmented epidermal and cutaneous lesions including warts, scars, striae,
dyschromia, hyperpigmentation, melasma, ephelides (freckles), lentigines, and cafe..au-lait macules. · The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.
· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6. 9, and 12 months after the completion of a treatment regime.
•Use on Fitzpatrick skin types I-V.

IPL 550-1200 nm handpiece is indicated for:
· The treatment of moderate inflammatory acne Vulgans.
· The treatment of benign pigmented epidermal lesions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).

  • · The treatment of face and body vascular and pigmented lesions.
    · The treatment of cutaneous lesions, including scars and striae.
    · The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.
    · The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.
    · Use on all skin types (Fitzpatrick I-VI).

IPL 580-1200 run handpiece is indicated for:
· The treatment of moderate inflammatory acne vulgaris.
· The treatment of benign pigmented esions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).
· The treatment of face and body vascular and pigmented lesions.
· The treatment of cutaneous lesions, including scars and striae.
· The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.
· The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.
· Use on all skin types (Fitzpatrick I-VI).

IPL 620-1200 nm handpiece is iodicated for:
· The treatment of tattoos.
· The treatment of moderate inflammatory acne vulgaris.
· The treatment of benign pigmented epidermal lesions includiog dyschromia, hyperpiementation, melasma, and ephelides (freckles), lentigines, nevi, melasma, and ca!e-au-lait.
· The treatment of cutaneous lesions including warts, scars and striae.
· The treatment of benign cutaneous vascular lesions includiog port wine stains, hemangiomas, facial. truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.
: The removal of unwanted hair and to effect stable long-term or permanent reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction io the number of hairs regrowiog when measured at 6. 9, and 12 months after the completion of a treatment regime.
· Use on all skin types (Fitzpatrick I-VI), iocludiog tanned skin.

IPL 755-1200 nm handpiece is indicated for:
• The treatment of tattoos.
· The treatment of moderate ioflammatory acne vulgaris.
· The treatment of benign pigmented epidermal lesions includiog dyschromia, hyperpigmentation, melasma, and ephelides (freckles).
· The treatment of cutaneous lesions iocluding warts, scars and striae.
· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.
· The treatment of psoriasis, vitiligo, atopic dermatitis (eczema), seborrheic dermatitis.
· The treatment of pseudofolliculitis barbae (PFB).
· The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.
·Use on all skin types (Fitzpatrick I-VI), including tanned skin.

Device Description

The portable device SUPERBIUM, is a multilaser and pulsed light system, designated to act on some common conditions of face and body (as specified in detail in Section 4). The equipment is designed as an expandable system for dermatologic and general surgery procedures, composed of a modular platform, which contains the entire electronics of the system and the cooling circuit, and a series of interchangeable handpieces to be connected on the platform, intended to treat specific groups of imperfections. A quick connection enables the quick and easy replacement of the various hand pieces that can be mounted on the modular platform.

AI/ML Overview

This document is a 510(k) summary for the "SUPERBIUM" medical laser system. It compares the device to several predicate devices to demonstrate substantial equivalence, rather than providing a performance study with specific acceptance criteria against a defined ground truth.

Therefore, many of the requested sections about acceptance criteria and study details cannot be fully answered from this document. However, I can extract the relevant information regarding the device's technical characteristics and the comparison to predicate devices, which serves the purpose of demonstrating equivalence.

Here's a summary of the available information based on the provided text:

1. A table of acceptance criteria and the reported device performance

Since this is a 510(k) submission showing substantial equivalence to predicate devices, there isn't a table of explicit acceptance criteria for the study's outcome in the traditional sense of a clinical trial. Instead, the "acceptance criteria" are implied by demonstrating that the SUPERBIUM device's technological characteristics and intended uses are "substantially equivalent" to the listed predicate devices. The "reported device performance" is essentially a comparison of these characteristics.

The tables within the document (e.g., "B) Nd:Yag Handpiece Long Pulse", "C) Nd:Yag Handpiece - Short Pulse", etc.) serve as the core of this comparison. For each handpiece, the SUPERBIUM's specifications (Wavelength, Output power, Max energy per pulse, Beam diameter, Fluence, Pulse duration, Emission frequency, and Intended Use) are presented alongside those of the predicate devices.

Example of "Acceptance Criteria" (Implicit for Substantial Equivalence) and "Reported Device Performance" (Comparison to Predicates):

CharacteristicSUPERBIUM (Reported Performance)Predicate Device A (e.g., HARMONY XL K072564)Predicate Device B (e.g., ICON AESTHETIC SYSTEM K103664)Implied "Acceptance Criteria" for Substantial Equivalence
Nd:Yag LP Wavelength1064 nm1064 nm1064 nmWavelength must be identical or clinically similar.
Nd:Yag LP Output Power45W max40W max50 WWithin comparable range of predicate devices.
Nd:Yag LP Max Energy/PulseLP: 45J (max)40 J50 JWithin comparable range of predicate devices.
Nd:Yag LP Fluence (6mm spot)160 J/cm230-150 J/cm2 (6mm)16/140 J/cm2 (6mm)Within comparable range of predicate devices.
Nd:Yag LP Pulse Duration1 - 25 ms40-60 ms (6mm) / 8-15ms (2mm)10 - 100 msWithin comparable range of predicate devices.
Nd:Yag LP Emission Freq.1 Hz (max)1 Hz0.2 - 2 HzIdentical or within comparable range.
Intended Use (Nd:Yag LP example)Treatment of vascular lesions, pigmented lesions, tattoos, hair removal, etc.Similar scope of treatments.Similar scope of treatments.Intended uses must be the same or highly similar.

Note: The document states "Any differences are considered minor and do not raise new issues of the safety and effectiveness of the SUPERBIUM device when compared to the predicate devices." This is the ultimate "acceptance" for a 510(k).

2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

The document explicitly states: "Animal and clinical studies were not necessary to demonstrate that the permormances are comparable to the predicate devices." Instead, the submission relies on direct comparison of technological characteristics. Therefore, there is no test set sample size or clinical data provenance to report. The data provenance for the comparison itself is simply from the regulatory submissions of the predicate devices.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

Not applicable, as no clinical study with a test set requiring expert ground truth was conducted for this 510(k) submission.

4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

Not applicable, as no clinical study with a test set requiring adjudication was conducted.

5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

Not applicable, as this is a medical laser system for various dermatological and surgical applications, not an AI-powered diagnostic device, and no MRMC study was performed.

6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

Not applicable, as this is a medical laser system, not an algorithm.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

Not applicable, as no clinical study requiring a specific ground truth was conducted. The ground for the submission is the regulatory information and technical specifications of the predicate devices.

8. The sample size for the training set

Not applicable, as this is a physical medical device and not a machine learning model.

9. How the ground truth for the training set was established

Not applicable, as this is a physical medical device and not a machine learning model.

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an emblem featuring a stylized caduceus, which is a symbol of medicine and health. The caduceus is depicted with a staff entwined by two snakes and topped with wings.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

April 12, 2016

Bios S.r.l Mr. Riccardo Pisati Regulatory Affairs Via Guido Rossa, 10/12 Vimodrone, IT-20090 Milan

Re: K153229 Trade/Device Name: Superbium Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: Class II Product Code: GEX, ONG, ONF Dated: March 21, 2016 Received: March 25, 2016

Dear Mr. Pisati:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in

{1}------------------------------------------------

the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

Jennifer R. Stevenson -A

For Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Indications for Use

510(k) Number (if known) K153229

Device Name Superbium

Indications for Use (Describe)

The Nd: Yag 1064 Laser Handpiece (Long Pulsed) is intended for:

-treatment of benign vascular lesions such as but not limited to port wine stains, hemangiomas, telangiectasias, rosacea. venus lake, facial and leg veins;

-treatment of benign pigmented lesions such as, but not limited to, senile lentigines (age spots), solar lentigos (sun spots), pigmented seborrheic keratoses, nevi, chloasma, cafe-au-lait macules, and plaques;

-tattoos (significant reduction in the intensity of black and/or blue-black tattoos);

verrucae, skin tags, seborrheic keratosis;

  • reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar;
  • coagulation and hemostasis of soft tissue;

-the removal of unwanted hair for skin types I-VI, and to effect stable long-term permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

The Nd: Yag 1064 Laser Handpiece (Short Pulsed) is intended for:

Removal of tattoos and blemishes of the skin, the treatment of various pigmentation lesions

Laser skin treatment procedures for the treatment of: Acne scars, Wrinkles

The Nd:YAG Q-Switched Handpieces (1064 nm) are indicated for treatment of:

  • Benign vascular lesions such as, but not limited to treatment of:

Port wine stains; Hemangiomas; Warts; Superficial and deep telangiectasias; Reticular veins (0.1-4.0 mm dia.) of the leg; Rosacea; Venus lake; Leg veins; Spider veins; Poikiloderma of Civatte; Angiomas

-Benign cutaneous lesions, such as, but not limited to:

Warts; Scars; Striae; Psoriasis

-Benign pigmented lesions such as, but not limited to:

Lentigos (age spots); Solar lentigos (sun spots); Cafe-au-lait macules; Seborrheic keratoses; Nevi and nevus of Ota; Chloasma; Verrucae; Skin tags; Keratoses; The removal of black, blue or green tattoos (significant reduction in the intensity of black and /or blue/black tattoos); Plaques

  • Pigmented benign lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments.

  • The non-ablative treatment of facial wrinkles, such as, but not limited to:

Periocular wrinkles; Perioral wrinkles;

-Laser skin resurfacing procedures for the treatment of:

Acne scars; Wrinkles

  • Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar.

-Indicated for use on all skin types (Fitzpatrick I-VI), including tanned skin.

The Nd:YAG Q-Switched Handpieces (532 nm) are indicated for treatment of:

-Incision, excision, ablation, vaporization of soft tissue.

  • Tattoo removal: Light blue; Yellow; Red; Green

  • Vascular lesions: Hemangiomas (Port wine stains/birthmarks, cavernous, cherry, spider, hemangiomas); Angiomas (cherry, spider); Telangiectasia; Spider nevi

-Benign pigmented lesions: Cafe-au-lait (macules); Lentigines (senile and solar); Freckles (ephelides); Chloasma; Nevi; Nevus spillus; Nevus of Ota ;Becker's Nevi

{3}------------------------------------------------

-Other benign pigmented cutaneous lesions: Verrucae; Skin tags; Keratoses; Plaques

The 2940 nm Er:YAG Laser Module handpiece is indicated for:

Coagulation, vaporization, ablation or cutting of soft tissue (skin) in Dermatology, Plastic Surgery, ENT, Gynecology, General Surgery, Podiatry and Ophthalmology (skin around the eyes). Laser skin resurfacing procedures for the treatment of:

Laser skin resurfacing procedures for the tr

A. Acne scars

  • Acne scars . . Wrinkles
    The 2940 nm Er: Yag Fractional tips are indicated for:

Use in soft tissue (skin, cutaneous tissue, subcutaneous tissue, striated and smooth tissue, muscle, cartilage meniscus, mucous membrane, lymph vessels and nodes; organs, and glands) such as, but not limited to: Dermatology and plastic Surgery: Skin resurfacing Treatment of wrinkles; Epidermal nevi; Telangiectasia; Spider veins; Actinic chelitis; Keloids; Verrucae; Skin tags; Keratoses; Scar revision (including acne scars).

The 1540 Fractional Non-ablative Laser Handpiece is intended for use in coagulation of soft tissue, skin resurfacing procedures as well as treatment of melasma, striae, acne scars and surgical scars.

IPL 400-1200 run handpiece is indicated for:

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions including dyschromia,

hyperpigmentation, melasma, and ephelides (freckles).

· The treatment of benign cutaneous lesions including warts, scars and striae.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.

·Use on all skin types (Fitzpatrick I-VI).

IPL500-1200 nm handpiece is indicated for:

· The treatment of moderate inflammatory acne (acne vulgaris).

· The treatment of tattoos and benign pigmented epidermal and cutaneous lesions including warts, scars, striae,

dyschromia, hyperpigmentation, melasma, ephelides (freckles), lentigines, and cafe..au-lait macules. · The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6. 9, and 12 months after the completion of a treatment regime.

•Use on Fitzpatrick skin types I-V.

IPL 550-1200 nm handpiece is indicated for:

· The treatment of moderate inflammatory acne Vulgans.

· The treatment of benign pigmented epidermal lesions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).

  • · The treatment of face and body vascular and pigmented lesions.
    · The treatment of cutaneous lesions, including scars and striae.

· The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI).

{4}------------------------------------------------

IPL 580-1200 run handpiece is indicated for:

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented esions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).

· The treatment of face and body vascular and pigmented lesions.

· The treatment of cutaneous lesions, including scars and striae.

· The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI).

IPL 620-1200 nm handpiece is indicated for:

· The treatment of tattoos.

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasma, and ephelides (freckles), lentigines, nevi, melasma, and cafe-au-lait.

· The treatment of cutaneous lesions including warts, scars and striae.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.

: The removal of unwanted hair and to effect stable long-term or permanent reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6. 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI), including tanned skin.

IPL 755-1200 nm handpiece is indicated for:

• The treatment of tattoos.

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasma, and ephelides (freckles).

· The treatment of cutaneous lesions including warts, scars and striae.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The treatment of psoriasis, vitiligo, atopic dermatitis (eczema), seborrheic dermatitis.

· The treatment of pseudofolliculitis barbae (PFB).

· The removal of unwanted hair to effect stable long-term or permanent hair reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

·Use on all skin types (Fitzpatrick I-VI), including tanned skin.

Type of Use (Select one or both, as applicable)

Prescription Use (Part 21 CFR 801 Subpart D)

D Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

{5}------------------------------------------------

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda. hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{6}------------------------------------------------

Bios s.r.l. rev.03 pag. 1 of 26

Section 5 510(k) Summary

SUBMITTER I.

Applicant InformationBios s.r.l.
Via Guido Rossa, 10/12
20090 Vimodrone (MI) – Italy
ContactIng. Aldo Casalino
Date Prepared3 November 2015
II. DEVICE
Device Trade NameSUPERBIUM
Common NameMedical Laser System
Regulatory classII
Classification NameLaser surgical instrument for use in general and plastic surgery and indermatology (21 CFR 878.4810)

Product Code

GEX, ONG, ONF

III. PREDICATE DEVICE

510(k) NumberPro CodeTrade NameApplicant
K072344GEX 21 CFR 878.4810FTC 21 CFR 878.4630APL MEDICAL SYSTEMBIOS
K103664GEX, ONG21 CFR § 878.4810ICON AESTHETIC SYSTEMPalomar
K072564GEX, FTC, HHR, LNK21 CFR 878.4810HARMONY XLMULTI APPLICATION PLATFORMALMA
K150140GEX 21 CFR 878.4810DERMABLATEASCLEPION
K111303GEX 21 CFR 878.4810OMNIMAXSHARPLIGHTTECHNOLOGIES
K090195GEX 21 CFR 878.4810LUX 1540PALOMAR

IV. DEVICE DESCRIPTION

The portable device SUPERBIUM, is a multilaser and pulsed light system, designated to act on some common conditions of face and body (as specified in detail in Section 4). The equipment is designed as an expandable system for dermatologic and general surgery procedures, composed of a modular platform, which contains the entire electronics of the system and the cooling circuit, and a series of interchangeable

{7}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 2 of 26

handpieces to be connected on the platform, intended to treat specific groups of imperfections. A quick connection enables the quick and easy replacement of the various hand pieces that can be mounted on the modular platform. The following handpieces are available:

    1. Handpiece Nd:Yag Laser contains a flash lamp excited source that emits at 1064nm, with 2 different modalities: long pulse (ms) and short pulse (us). The handpiece can be equipped with different spots and also with an optical fiber. A pointing laser helps to guide the operator during the treatment. With this laser it is possible to treat vascular lesions, pigmented lesions, tattoos, scars, soft tissue, hair removal treatments (long pulse) and pigmented and vascular lesions, wrinkles and podiatry (short pulse). This laser is class IV according to the Standard EN60825-1.
    1. Handpiece Nd: Yag Laser contains a flash lamp excited source that emits 1064 and 532 nm Qs (0-Switched). The pulse duration is very short (ns), typical characteristic of OS lasers. The handbiece can be equipped with different spots. A pointing laser helps to guide the operator during the treatment. The Qs laser is ideal for the treatment of vascular lesions, scars, pigmented lesions, skin resurfacing (1064 nm) and soft tissue, tattoo, vascular lesions, pigmented lesions (532 nm). This laser is class IV according to the Standard EN60825-1.
    1. Handpiece Erbium Laser contains a flash lamp excited source that emits at 2940 nm. The handpiece can be equipped with different spots; two of them are fractional, so they divide the shot in several microbeams. The Er:Yag laser is ideal for soft tissue, skin resurfacing, skin lesions treatments. This laser is class IV according to the Standard EN60825-1.
    1. Handpiece Erbium Glass Laser contains a flash lamp excited source that emits at 1540 mm. The handpiece can be equipped with two spots, both fractional, that divide the shot in several microbeams. The Er:Glass is ideal for use in dermatological procedures requiring skin resurfacing and coagulation of soft tissue, for example scar treatments. This laser is class IV according to the Standard EN60825-1.
    1. Handpiece Pulsed Light contains a xenon lamp that emits from 400 and 1200 nm. On this handpiece it is possible to change easily the guide light, equipped with a specific light filter and to use thus that one most adequate for the individual photo type. It is possible also to have a cooling for the guides, as optional. With the use of this handpiece is possible to perform pigmented lesions, scars, vascular lesions, tattoos, hair removal.

{8}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 3 of 26

V. Indication for Use

The Nd: Yag 1064 Laser Handpiece (Long Pulsed) is intended for:

  • treatment of vascular lesions such as but not limited to, port wine stains, hemangiomas, telangiectasias, rosacea, venus lake, facial and leg veins;

  • treatment of benign pigmented lesions such as, but not limited to, senile lentigines (age spots), solar lentigos (sun spots), pigmented seborrheic keratoses, nevi, chloasma, cafe-au-lait macules, and plaques;

  • tattoos (significant reduction in the intensity of black and/or blue-black tattoos);

verrucae, skin tags, seborrheic keratosis;

  • reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar:

  • coagulation and hemostasis of soft tissue;

  • the removal of unwanted hair for skin types I-VI, and to effect stable long-term permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

The Nd: Yag 1064 Laser Handpiece (Short Pulsed) is intended for:

Removal of tattoos and blemishes of the skin, the treatment of various pigmentation lesions Laser skin treatment procedures for the treatment of: Acne scars, Wrinkles

The Nd:YAG Q-Switched Handpieces (1064 nm) are indicated for treatment of:

  • Benign vascular lesions such as, but not limited to treatment of:

Port wine stains; Hemangiomas; Warts; Superficial and deep telangiectasias (venulectasias); Reticular veins (0.1-4.0 mm dia.) of the leg; Rosacea; Venus lake; Leg veins; Spider veins; Poikiloderma of Civatte; Angiomas

  • Benign cutaneous lesions, such as, but not limited to:

Warts; Scars; Striae; Psoriasis

  • Benign pigmented lesions such as, but not limited to:

Lentigos (age spots); Solar lentigos (sun spots); Cafè-au-lait macules; Seborrheic keratoses; Nevi and nevus of Ota; Chloasma; Verrucae; Skin tags; Keratoses; The removal of black, blue or green tattoos (significant reduction in the intensity of black and /or blue/black tattoos); Plaques

  • Pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments.

  • The non-ablative treatment of facial wrinkles, such as, but not limited to:

Periocular wrinkles; Perioral wrinkles;

  • Laser skin resurfacing procedures for the treatment of:

Acne scars; Wrinkles

  • Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar.

  • Indicated for use on all skin types (Fitzpatrick I-VI), including tanned skin.

The Nd:YAG Q-Switched Handpieces (532 nm) are indicated for treatment of:

  • Incision, excision, ablation, vaporization of soft tissue.

  • Tattoo removal: Light blue; Yellow; Red; Green

  • Vascular lesions: Hemangiomas (Port wine stains/birthmarks, cavernous, cherry, spider, hemangiomas); Angiomas (cherry, spider); Telangiectasia; Spider nevi

{9}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 4 of 26
  • Benign pigmented lesions: Cafè-au-lait (macules); Lentigines (senile and solar); Freckles (ephelides); Chloasma; Nevi; Nevus spillus; Nevus of Ota ;Becker's Nevi

  • Other pigmented cutaneous lesions: Verrucae; Skin tags; Keratoses; Plaques

The 2940 nm Er: Y AG Laser Module handpiece is indicated for:

Coagulation, vaporization, ablation or cutting of soft tissue (skin) in Dermatology, Plastic Surgery, Oral Surgery, ENT, Gynecology, General Surgery, Podiatry and Ophthalmology (skin around the eyes). Laser skin resurfacing procedures for the treatment of:

  • Acne scars ●
  • . Wrinkles

The 2940 nm Er: Yag Fractional tips are indicated for:

Use in soft tissue (skin, cutaneous tissue, subcutaneous tissue, striated and smooth tissue, muscle, cartilage meniscus, mucous membrane, lymph vessels and nodes; organs, and glands) such as, but not limited to:

glands) such as, but not limited to:
Dermatology and plastia Surgery Skin ros

Dermatology and plastic Surgery: Skin resurfacing Treatment of wrinkles; Epidermal nevi; Telangiectasia: Spider veins; Actinic chelitis; Keloids; Verrucae; Skin tags; Keratoses; Scar revision (including acne scars).

The 1540 Fractional Non-ablative Laser Handpiece is intended for use in coagulation of soft tissue, skin resurfacing procedures as well as treatment of melasma, striae, acne scars and surgical scars.

IPL 400-1200 run handpiece is indicated for:

· The treatment of moderate inflanunatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions including dyschromia,

hyperpigmentation, inelasma, and ephelides (freckles).

· The treatment of cutaneous lesions including warts, scars and striae.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas,

poikiloderma of Civatte, leg veins and venous malformations.

·Use on all skin types (Fitzpatrick I-VI).

IPL500-1200 nm handpiece is indicated for:

· The treatment of moderate inflanunatory acne (acne vulgaris).

· The treatment of tattoos and benign pigmented epidermal and cutaneous lesions including warts, scars, striae, dyschromia, hyperpigmentation, melasma, ephelides (freckles), lentigines, nevi, melasma, and cafe..au-lait macules.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte. leg veins and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defmed as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

·Use on Fitzpatrick skin types I-V.

IPL 550-1200 nm handpiece is indicated for:

{10}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 5 of 26

· The treatment of moderate mtlammatory acne VUlgans.

· The treatment of benign pigmented epidermal lesions, includiog dyschromia, hyperpigmentation, melasma and ephelides (freckles).

· The treatment of face and body vascular and pigmented lesions.

· The treatment of cutaneous lesions, includiog scars and striae.

· The treatment of benign cutaneous vascular lesions, includiog port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, angiomas and spider angiomas, poikiloderma of Civatte, leg veios and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI).

IPL 580-1200 run handpiece is indicated for:

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).

· The treatment of face and body vascular and pigmented lesions.

· The treatment of cutaneous lesions, including scars and striae.

· The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI).

IPL 620-1200 nm handpiece is iodicated for:

· The treatment of tattoos.

· The treatment of moderate inflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions includiog dyschromia, hyperpiementation, melasma, and ephelides (freckles), lentigines, nevi, melasma, and ca!e-au-lait.

· The treatment of cutaneous lesions including warts, scars and striae.

· The treatment of benign cutaneous vascular lesions includiog port wine stains, hemangiomas, facial. truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.

: The removal of unwanted hair and to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction io the number of hairs regrowiog when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI), iocludiog tanned skin.

IPL 755-1200 nm handpiece is indicated for:

· The treatment of tattoos.

· The treatment of moderate ioflammatory acne vulgaris.

· The treatment of benign pigmented epidermal lesions includiog dyschromia, hyperpigmentation, melasma, and ephelides (freckles).

{11}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 6 of 26

· The treatment of cutaneous lesions iocluding warts, scars and striae.

· The treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, erythema of rosacea, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.

· The treatment of psoriasis, vitiligo, atopic dermatitis (eczema), seborrheic dermatitis.

· The treatment of pseudofolliculitis barbae (PFB).

· The removal of unwanted hair to effect stable long-term or permanent hair reduction. Permanent reduction in hair regrowth is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

· Use on all skin types (Fitzpatrick I-VI), including tanned skin.

{12}------------------------------------------------

VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICES

By comparing SUPERBIUM to the legally marketed predicate devices, it is substantially equivalent in terms of intended use and utilizes similar functional features including energy source, frequency, fluency, pulse width.

The general features of SUPERBIUM are similar to those of the predicates in particular as regards the classification IV laser, the equipment of a the cooling system and the electrical specifications. Also the predicate devices are equipped with a touch screen and with a control SW.

The intended use of each handpiece of SUPERBIUM are identical to those of the handpieces of the predicates and also the technical characteristics are the same, in particular:

  • handpiece Nd:Yag Long Pulse of SUPERBIUM with the wavelength of 1064 nm applies an output power and a maximum energy per pulse operating in the same range of Harmony XL K072564 and the Icon Aesthetic System K103664.
    The emission frequency of the handpiece Nd:Yag Long Pulse of SUPERBIUM is the same of Harmony XL K072564 and it is in the same interval the Icon Aesthetic System K103664.

  • handpiece Nd:Yag Short Pulse of SUPERBIUM with the wavelength of 1064 nm applies an output power and a maximum energy per pulse operating, in the same range of APL Medical System K072344.

  • handpiece Nd:YAG Q-Switched of SUPERBIUM with a wavelength of 1064+532 nm applies a maximum output power and a maximum energy per pulse similar to those of the Harmony XL K072564. The pulse duration is in the same range of predicates and fluence value is similar to that of the Harmony XL K072564. The emission frequency of the handpiece Nd: YAG Q-Switched of SUPERBIUM is the same of predicates.

  • handpiece Er.Yag of SUPERBIUM with a wavelength of 2940 nm applies a maximum output power in the same range of values APL Medical System K072344 and of the Dermablate K150140 and a maximum energy per pulse that is the same value of Dermablate K150140. The value of the fluence the same to predicate devices Dermablate K150140 for the same spot size. The emission frequency of the handpiece Er: Yag of SUPERBIUM is similar to that of the Dermablate K150140.

{13}------------------------------------------------

  • handpiece Er:Yag Fractional Tip of SUPERBIUM is equal to the predicate SHARPLIGHT - TECHNOLOGIES OMNIMAX K1113603. The numbers of dots are the same, and also the fluencies are very similar. The frequency emission is the same.
  • handpiece Er:Yag Glass of SUPERBIUM with a wavelength of 1540 nm is equal to the predicate -Palomar LUX 540 K090195. In particular they have same parameters for max energy, dot density and consequently the fluence parameters are the same. Also the pulse duration and the emission frequency are equal to the predicate.
  • the IPL handpiece of SUPERBIUM has the same emission spectrum (400 1200 nm) of the Harmony XL K072564 and of APL Medical System K072344. The standard filters equipment is the same and also the maximum energy per pulse is in the same range of mentioned predicates. The maximum fluence valueis the same and the values of the maximum pulse duration and frequency are similar.

{14}------------------------------------------------

Base: 50x54x38

Dimensions (LxPxH) cm

50x45x25 cm

Section V

A) General Features
DeviceBasicTechnicalDataApplicantBIOSBIOSPalomarALMAASCLEPIONSHARPLIGHTTECHNOLOGIESPALOMAR
Device NameSUPERBIUMAPL MEDICALSYSTEMICON AESTHETICSYSTEMHARMONY XLDERMABLATEOMNIMAXLUX 1540Handpiece
510k---K072344K103664K072564K150140K111303K090195
ClassificationGEX 21 CFR878.4810,ONF 21CFR 878.4810GEX 21 CFR 878.4810FTC 21 CFR 878.4630GEX, ONG21 CFR § 878.4810GEX, FTC, HHR, LNK21 CFR 878.4810GEX878.4810GEX878.4810GEX878.4810
Intended UseNd:Yag HandpieceLPSee Table BSee Table BSee Table B---
Nd:Yag HandpieceSPSee Table C-----
Nd:Yag Q-SwitchedHandpieceSee Table D-See Table D---
Er:Yag HandpieceSee Table E--See Table E--
Er:Yag HandpieceFractional----See Table F-
Er:Yag GlassHandpiece-----See Table G
IPL HandpieceSee Table H-See Table H---
DisplayDisplay LCD 10.4"touch screen.LCD Color Display"touch screen".LCD Color Display"touch screen".LCD Color display"touch screen"Display "touchscreen"Display "touchscreen"-
Voltage110V Ac ±10%110V Ac ±10%90 - 264 VAC100 -120 VAC110V Ac100-240 V-
Frequency60 Hz ± 1%60 Hz ± 1%50 - 60 Hz50 - 60 Hz50 - 60 Hz50-60Hz,-
Absorbed power12A (average)— 24Amax8A (average)—12,5A max20 A20 A500 VAmax 1-A-
Cooling systemYESYESYESYESYESYES-
Laser classIVIVIVIVIVIVIV
Weight35 KgApprox 21 Kg47.17 KgUpper Unit 15 kg,Lower Unit 45 kg75 Kg70kg-

58x54x103 cm

39.7 x 55 x 123 cm

36 x 60 x 93 cm

56 x 42 x 105 cm

{15}------------------------------------------------

B)Nd:Yag Handpiece Long Pulse

ApplicantBIOSBIOSALMAPALOMAR
Device NameSUPERBIUMAPL MEDICALSYSTEMHARMONY XLICON AESTHETIC SYSTEM
510k---K072344K072564K103664
ClassificationGEX 21 CFR 878.4810, ONFGEX, FTCGEX, FTC, HHR, LNKGEX, ONG
Laser sourceNd:YAG LPNd:YAG LPNd:Yag LPNd:Yag
Wavelenght1064 nm1064 nm1064 nm1064 nm
Output power45W max20W max40W max50 W
Max energy per pulseLP: 45J (max)LP: 20J (max)40 J50 J
Beam diameter (spot)1, 2, 3, 4, 5, 6, 9, 11,12,13,14,15 mm2; 5 mm6 mm1,5; 3; 6; 10 mm
Fluence500J/cm2 (max);3 mm: 500J/cm2 (max);6 mm: 160 J/cm2285 J/cm2 (spot3mm)30-450 J/cm2 (2);30-150 J/cm2 (6);30-450 J/cm2 (10)1,5 mm - 250/750 J/cm2;3 mm - 70/450 J/cm2;6 mm - 16/140 J/cm2;10 mm - 7/50 J/cm2
Pulse durationLP: 1 - 25 msLP: 5 - 25 ms8-15ms (2);40-60 ms (6);15 ms (10)10 - 100 ms
Emission frequencyLP: 1 Hz (max)LP: 1 Hz (max)1 Hz0,2 - 2 Hz
Intended UseThe Nd:Yag 1064 Laser Handpiece(Long Pulsed) is intended for:1064 nm Long Pulsed ModuleHandpiecesThe 1064 nm Nd:YAG Laser Modulehandpieces (Long Pulsed and Q-Switched with and without contact-cooling) are indicated for treatmentand clearance of:The 1064 Laser Handpiece isintended for
treatment of vascular lesionssuch as but not limited to, portwine stains, hemangiomas,telangiectasias, rosacea, venuslake, facial and leg veins;6. treatment ofcapillaries,teleangiectasies andvascular lesions (LP)• Benign vascular lesions such as,but not limited to treatment of:Port wine stains; Hemangiomas;Warts; Superficial and deeptelangiectasias (venulectasias);Reticular veins (0.1-4.0 mm dia.) ofthe leg; Rosacea; Venus lake; Legveins; Spider veins; Poikiloderma ofCivatte; Angiomastreatment of vascular lesionssuch as but not limited to,port wine stains,hemangiomas,telangiectasias, rosacea,venus lake, facial and legveins;
ApplicantBIOSBIOSALMAPALOMAR
SUPERBIUMAPL MEDICAL SYSTEM
Device NameHARMONY XLICON AESTHETIC SYSTEM
510k---K072344K072564K103664
treatment of benign pigmentedlesions such as, but not limitedto, senile lentigines (age spots),solar lentigos (sun spots),pigmented seborrheickeratoses, nevi, chloasma, cafe-au-lait macules, and plaques;• Benign cutaneous lesions, such as,but not limited to:Warts; Scars; Striae; Psoriasistreatment of benignpigmented lesions such as,but not limited to, senilelentigines (age spots), solarlentigos (sun spots),pigmented seborrheickeratoses, nevi, chloasma,cafe-au-lait macules, andplaques;
tattoos (significant reduction inthe intensity of black and/orblue-black tattoos);verrucae, skin tags, seborrheickeratosis;• Benign pigmented lesions such as,but not limited to:Lentigos (age spots); Solar lentigos(sun spots); Cafè-au-lait macules;Seborrheic keratoses; Nevi andnevus of Ota; Chloasma; Verrucae;Skin tags; Keratoses; The removal ofblack, blue or green tattoos(significant reduction in theintensity of black and /or blue/blacktattoos); Plaquestattoos (significant reductionin the intensity of blackand/or blue-black tattoos);verrucae, skin tags,seborrheic keratosis;
reduction of red pigmentationin hypertrophic and keloid scarswhere vascularity is an integralpart of the scar;Laser skin resurfacing proceduresfor the treatment of:Acne scars; Wrinklesreduction of redpigmentation in hypertrophicand keloid scars wherevascularity is an integral partof the scar;
coagulation and hemostasis ofsoft tissue;Reduction of red pigmentation inhypertrophic and keloid scars wherevascularity is an integral part of thescar.coagulation and hemostasisof soft tissue;
Section Vpag. 12 of 26
ApplicantBIOSBIOSALMAPALOMAR
Device NameSUPERBIUMAPL MEDICALSYSTEMHARMONY XLICON AESTHETIC SYSTEM
510k---K072344K072564K103664
the removal of unwanted hairfor skin types I-VI, and to effectstable long-term permanenthair reduction;1. The removal ofunwanted hair andto effect stable long-term or permanenthair reduction (LP)1064 nm Long Pulsed Only Nd:YAGLaser Module HandpiecesThe 1064 nm Nd:YAG lasers (LongPulsed only, with and withoutcontact-cooling) is indicated for:- Removal of unwanted hair, forstable long-term, or permanent,hair reduction through selectivetargeting of melanin in hair follicles.- Removal or lightening of unwantedhair (with and without adjuvantpreparation)- Treatment of pseudofolliculitisbarbae (PFB)- Indicated for use on all skin types(Fitzpatrick I-VI), including tannedthe removal of unwanted hairfor skin types I-VI, and toeffect stable long-termpermanent hair reduction

{16}------------------------------------------------

Section V

Bios s.r.l. rev.03

{17}------------------------------------------------

Section V

Bios s.r.l.

rev.03

{18}------------------------------------------------

Bios s.r.l. rev.03 pag. 13 of 26

C)Nd:Yag Handpiece - Short Pulse

ApplicantBIOSBIOSApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMDevice NameSUPERBIUMAPL MEDICALSYSTEMHARMONY XL
510k---K072344510k---K072344K072564
ClassificationGEX 21 CFR 878.4810, ONFGEX, FTCClassificationGEX 21 CFR 878.4810,ONF 21 CFR 878.4810GEX, FTCGEX, FTC, HHR, LNK
Laser sourceNd:YAG SPNd:YAG SPLaser sourceNd:YAG Q - SwitchedNd:YAG — QSwitchedNd:YAG - Q Switched
Wavelenght1064 nm1064 nmWavelenght1064+532 nm.1064+532 nm.1064+532 nm.
Output power45W max20W maxOutput power10W max1,2 W max0,4 - 6 W
Max energy per pulse1000 mJ2000 J (max)Max energy perpulse1800 mJ (max).1000 mJ400- 1200 mJ
Beam diameter (spot)6, 92/5 mmPulse durationup to 12 ns10 ns20 ns
Fluence6 mm: 3.6 J/cm29 mm: 1.6 J/cm2spot 5 mm: 10 J/cm2Fluence180 J/cm232 J/cm2 (spot 2mm)152 J/cm2 max
Pulse durationSP: 200 - 700 µsSP: 100 – 500 µsEmissionfrequency (max)5 Hz5 Hz1; 2; 5 Hz
Emission frequencySP: 10Hz (max)SP: 3 Hz (max)Beam diameter(spot)2, 4, 10 mm; 1-2-3-3,5 mm1; 3 mm1; 2; 3;4; 5; 6 mm
Intended UseRemoval of tattoos and blemishes of the skin, the treatment of variouspigmentation lesions (SP)Laser skin treatment procedures for the treatment of: Acne scars, Wrinkles (SP)5. removal of tattoos and blemishesof the skin, the treatment of variouspigmentation lesions (SP)2. Laser skin treatment proceduresfor the treatment of: Acne scars,Wrinkles (SP)Intended UseThe Nd:YAG Q-Switched Handpieces (1064 nm) areindicated for treatment of:- Benign vascular lesions such as, but not limited totreatment of:Port wine stains; Hemangiomas; Warts; Superficial and deeptelangiectasias (venulectasias); Reticular veins (0.1-4.0 mmdia.) of the leg; Rosacea; Venus lake; Leg veins; Spider veins;Poikiloderma of Civatte; Angiomas- Benign cutaneous lesions, such as, but not limited to:Warts; Scars; Striae; Psoriasis- Benign pigmented lesions such as, but not limited to:Lentigos (age spots); Solar lentigos (sun spots); Cafè-au-laitmacules; Seborrheic keratoses; Nevi and nevus of Ota;1064 nm Long Pulsed and Q-Switched Nd:YAG LaserModule HandpiecesThe 1064 nm Nd:YAG Laser Module handpieces (Long Pulsecand Q-Switched with and without contact-cooling) areindicated for treatment and clearance of.• Benign vascular lesions such as, but not limited totreatment of:Port wine stains; Hemangiomas; Warts; Superficial and deeptelangiectasias (venulectasias); Reticular veins (0.1-4.0 mmdia.) of the leg; Rosacea; Venus lake; Leg veins; Spider veins;Poikiloderma of Civatte; Angiomas• Benign cutaneous lesions, such as, but not limited to:Warts; Scars; Striae; Psoriasis• Benign pigmented lesions such as, but not limited to:

{19}------------------------------------------------

Bios s.r.l. rev.03 pag. 14 of 26

D)Nd:Yag Q-Switched Handpiece

{20}------------------------------------------------

Section V

ApplicantBIOSALMA
Device NameSUPERBIUMHARMONY XL
510k---K072564
black, blue or green tattoos (significant reduction in theintensity of black and /or blue/black tattoos); Plaques- Pigmented lesions to reduce lesion size, for patients withlesions that would potentially benefit from aggressivetreatment, and for patients with lesions that have notresponded to other laser treatments.- The non-ablative treatment of facial wrinkles, such as, butnot limited to:Periocular wrinkles; Perioral wrinkles;- Laser skin resurfacing procedures for the treatment of:Acne scars; Wrinkles- Reduction of red pigmentation in hypertrophic and keloidscars where vascularity is an integral part of the scar.- Indicated for use on all skin types (Fitzpatrick I-VI),including tanned skin.Lentigos (age spots); Solar lentigos (sun spots); Cafè-au-laitmacules; Seborrheic keratoses; Nevi and nevus of Ota;Chloasma; Verrucae; Skin tags; Keratoses; The removal ofblack, blue or green tattoos (significant reduction in theintensity of black and /or blue/black tattoos); Plaques• Pigmented lesions to reduce lesion size, for patients withlesions that would potentially benefit from aggressivetreatment, and for patients with lesions that have notresponded to other laser treatments.• The non-ablative treatment of facial wrinkles, such as,but not limited to:Periocular wrinkles; Perioral wrinkles;• Laser skin resurfacing procedures for the treatment of:Acne scars; Wrinkles• Reduction of red pigmentation in hypertrophic and keloidscars where vascularity is an integral part of the scar.• Indicated for use on all skin types (Fitzpatrick I-VI),including tanned skin.
The Nd:YAG Q-Switched Handpieces (532 nm) are indicatedfor treatment of:- Incision, excision, ablation, vaporization of soft tissue.- Tattoo removal: Light blue; Yellow; Red; Green- Vascular lesions: Hemangiomas (Port winestains/birthmarks, cavernous, cherry, spider, hemangiomas);Angiomas (cherry, spider); Telangiectasia; Spider nevi- Benign pigmented lesions:Cafè-au-lait (macules); Lentigines (senile and solar); Freckles(ephelides); Chloasma; Nevi; Nevus spillus; Nevus of Ota;Becker's Nevi- Other pigmented cutaneous lesions:Verrucae; Skin tags; Keratoses; Plaques5. removal oftattoos andblemishes of theskin, thetreatment ofvariouspigmentationlesionsK072344532 nm Long Pulsed and Q-Switched FD Nd:YAG LaserModule Handpiece TipsThe 532 nm Frequency-Doubled (FD) Nd:YAG Laser Modulehandpieces tips (Long Pulsed and Q-Switched, with andwithout contact-cooling) are indicated for:• Incision, excision, ablation, vaporization of soft tissue.• Tattoo removal: Light blue; Yellow; Red; Green• Vascular lesions: Hemangiomas (Port winestains/birthmarks, cavernous, cherry, spider, hemangiomas);Angiomas (cherry, spider); Telangiectasia; Spider nevi• Benign pigmented lesions:Cafè-au-lait (macules); Lentigines (senile and solar); Freckles(ephelides); Chloasma; Nevi; Nevus spillus; Nevus of Ota;Becker's Nevi• Other pigmented cutaneous lesions:Verrucae; Skin tags; Keratoses; Plaques

E)Er:Yag Handpiece

{21}------------------------------------------------

Section V

Bios s.r.l.
rev.03

ApplicantBIOSBIOSAsclepion
Device NameSUPERBIUMAPL MEDICAL SYSTEMDERMABLATE
510k---K072344K150140
ClassificationGEX 21 CFR 878.4810,ONF 21 CFR 878.4810GEX, FTCGEX
Laser sourceEr:YAGEr:YAGEr:YAG
Wavelenght2.940 nm.2.940 nm.2.940 nm.
Output power12 W max4 W20 W
Max energy perpulse2,5 J (max).800 mJ (max)2,5 mJ
Beam diameter(spot)1/ 9 mm2 -8 mm1/12 mm
Fluence316 J/cm² (spot 1 mm)22 J/cm² (spot 2 mm)318 J/cm² (spot 1 mm)
Emissionfrequency5 Hz5 Hz20 Hz
Intended UseCoagulation, vaporization, ablation or cuttingof soft tissue (skin) in Dermatology, PlasticSurgery, Oral Surgery, ENT, Gynecology,General Surgery, Podiatry and Ophthalmology(skin around the eyes).Laser skin resurfacing procedures for thetreatment of:Acne scarsWrinklesLaser skin resurfacing procedures for thetreatment of:Acne scarsWrinklesIncision, excision, ablation, vaporization of softtissue.Coagulation, vaporization, ablation orcutting of soft tissue (skin) inDermatology, Plastic Surgery, OralSurgery, ENT, Gynecology, GeneralSurgery, Podiatry and Ophthalmology(skin around the eyes).

{22}------------------------------------------------

F) Er:Yag Handpiece Fractional Tip

ApplicantBIOSSHARPLIGHT TECHNOLOGIES
Device NameSUPERBIUMOMNIMAX
510kK153229K111303
ClassificationGEX 21 CFR 878.4810,ONF 21 CFR 878.4810GEXNUV, ONG, ONE, ONF
Laser sourceEr:YAGEr:YAG
Wavelenght2.940 nm2.940 nm
Beam diameter (dots)7x79x97x79x9
Fluence25 mJ/dot (7x7 mm)13 mJ/dot (9x9 mm)25 mJ/dot (7x7 mm)13 mJ/dot (9x9 mm)
Emission frequencyUp to 1,5 HzUp to 1,5 Hz
Intended UseThe Er:Yag Fractional tips are indicated for:Use in soft tissue (skin, cutaneous tissue, subcutaneous tissue,striated and smooth tissue, muscle, cartilage meniscus, mucousmembrane, lymph vessels and nodes; organs, andglands) such as, but not limited to:*Dermatology and plastic Surgery: Skin resurfacing3 Treatmentof wrinkles; Epidermal nevi; Telangiectasia; Spider veins; Actinicchelitis; Keloids; Verrucae; Skin tags; Anal tags; Keratoses; Scarrevision (including acne scars).Use in soft tissue (skin, cutaneous tissue, subcutaneous tissue,striated and smooth tissue, muscle, cartilage meniscus,mucous membrane, lymph vessels and nodes; organs, andglands) such as, but not limited to:*Dermatology and plastic Surgery: Skin resurfacing3Treatment of wrinkles; Epidermal nevi; Telangiectasia; Spiderveins; Actinic chelitis; Keloids; Verrucae; Skin tags; Anal tags;Keratoses: Scar revision (including acne scars):

{23}------------------------------------------------

G)Er:Yag Glass Handpiece

ApplicantBIOSPALOMARApplicantBIOSBIOSALMA
Device NameSUPERBIUMLUX 1540Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510kK153229K090195510k---K072344K072564
ClassificationGEX 21 CFR 878.4810,ONF 21 CFR 878.4810GEXClassificationGEX 21 CFR 878.4810,ONF 21 CFR 878.4810GEX, FTCGEX, FTC, HHR, LNK
Laser sourceEr:GlassEr:GlassSourcePulsed light Xenon lampPulsed light Xenon lampPulsed light fluorescence lamp
Wavelenght1540 nm1540 nmEmission spectrum400 – 1.200 nm400 – 1.000 nm420 – 950 nm
Max energy per pulse10 J10 JSpot dimension1; 3; 5; 8 cm28 cm23; 6 cm2
Dot Density (Dot/cm²)100; 320100; 320Standard filters500-550-580-620-755 nm530; 550; 580; 620 nm420; 515; 540; 570; 780 nm
Fluence100mJ/dot (max) (100 dots)31mJ/dot (max) (320 dots)100mJ/dot (max) (100 dots)31mJ/dot (max) (320 dots)Max energy per pulse200 J250 J180 J
Pulse durationUp to 15 msUp to 15 msFluence (max)30 J/cm230 J/cm230 J/cm2
Emission frequencyUp to 1,5 HzUp to 1,5 HzPulse duration (max)From 1 to 20 ms5 - 50 ms10 - 50 ms
Intended UseThe Er:Yag Glass 1540 nm Fractional Laser Handpiece is intended for use in:coagulation of soft tissue, skin resurfacing proceduresas well as treatment of melasma, striae, acne scars and surgical scars.The Palomar Lux1540 Handpiece is intended for use in:Coagulation of soft tissue;Skin resurfacing procedures;Treatment of melasma and striae; Treatment of acne scars and surgical scars.Emission frequency(max)1 Hz1 Hz2 - 4 Hz
Pause between onepulse train and thenextFrom 5 to 500 msFrom 5 to 100 ms-
Intended UseIPL 400-1200 nm handpiece is indicatedfor:* The treatment of moderateinflammatory acne vulgaris.· The treatment of benign pigmentedepidermal lesions including dyschromia,hyperpigmentation, inelasma, andephelides (freckles).· The treatment of cutaneous lesionsincluding warts, scars and striae.· The treatment of benign cutaneousvascular lesions including port winestains, hemangiomas, facial, truncal andleg telangiectasias, rosacea, erythemaof rosacea, angiomas and spider420-950 nm Acne Module AFT HandpieceThe Advanced Fluorescence Technology(AFT) 420-950 nm Acne Module handpiece(with and without contact-cooling) isindicated for:* The treatment of moderateinflammatory acne vulgaris.· The treatment of benign pigmentedepidermal lesions including dyschromia,hlyperpigmentation, inelasma, andephelides (freckles).· The treatment of cutaneous lesionsincluding warts, scars and striae.· The treatment of benign cutaneousvascular lesions including port wine stains,

{24}------------------------------------------------

Bios s.r.l.
rev.03 pag. 19 of 26

H)IPL Handpiece

{25}------------------------------------------------

Section V

Bios s.r.l. rev.03

pag. 20 of 26

ApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510k---K072344K072564
angiomas, poikiloderma of Civatte, legveins and venous malformations.· Use on all skin types (Fitzpatrick I-VI).hemangiomas, facial, truncal and legtelangiectasias, rosacea, erythema ofrosacea, angiomas and spider angiomas,poikiloderma of Civatte, leg veins andvenous malformations.· Use on all skin types (Fitzpatrick I-VI).
IPL 500-1200 nm handpiece is indicatedfor:· The treatment of moderateinflammatory acne (acne vulgaris).* The treatment of tattoos and benignpigmented epidermal and cutaneouslesions including warts, scars, striae,dyschromia, hyperpigmentation,melasma, ephelides (freckles),lentigines, nevi, melasma, and cafè-au-lait macules.* The treatment of benign cutaneousvascular lesions including port winestains, hemangiomas, facial, truncal andleg telangiectasias, rosacea, erythemaof rosacea,angiomas and spider angiomas,poikiloderma of Civatte, leg veins andvenous malformations.· The removal of unwanted hair to effectstable long-term or permanent hairreduction.· Use on Fitzpatrick skin types I-V.515-950 nm SV515 & SVL515 Module AFTHandpiecesThe Advanced Fluorescence Technology(AFT) 515-950 nm VL515 and SVL515Module handpieces (with and withoutcontact-cooling) are indicated for:· The treatment of moderate inflammatoryacne (acne vulgaris).* The treatment of tattoos and benignpigmented epidermal and cutaneouslesions including warts, scars, striae,dyschromia, hyperpigmentation, melasma,ephelides (freckles), lentigines, nevi,melasma, and cafè-au-lait macules.* The treatment of benign cutaneousvascular lesions including port wine stains,hemangiomas, facial, truncal and legtelangiectasias, rosacea, erythema ofrosacea, angiomas and spider angiomas,poikiloderma of Civatte, leg veins andvenous malformations.· The removal of unwanted hair to effectstable long-term or permanent hairreduction.
ApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510k---K072344K072564
IPL 550-1200 nm handpiece is indicatedfor:540-950 nm VL/PL, VP, and SSR Module
· The treatment of moderateAFT Handpieces
inflammatory acne vulgaris.The Advanced Fluorescence Technology
· The treatment of benign pigmented(AFT) 540-950 nm VL/PL, VP, and SSR
epidermal lesions including dyschromia,Module
hyperpigmentation, melasma, andhandpieces (with and without contact-
ephelides (freckles), lentigines, nevi,cooling) are indicated for:
melasma, and· The treatment of moderate inflammatory
cafè-au-lait macules.acne vulgaris.
* The treatment of cutaneous lesions· The treatment of benign pigmented
including warts, scars and striae.epidermal lesions including dyschromia,
· The treatment of benign cutaneoushyperpigmentation, melasma, and
vascular lesions including port wineephelides (freckles), lentigines, nevi,
stains, hemangiomas, facial, truncal andmelasma, and
leg telangiectasias, rosacea, erythemacafè-au-lait macules.
of rosacea, angiomas and spider* The treatment of cutaneous lesions
angiomas, poikiloderma of Civatte, legincluding warts, scars and striae.
veins and venous malformations.· The treatment of benign cutaneous
* The removal of unwanted hair tovascular lesions including port wine stains,
effect stable long-term or permanenthemangiomas, facial, truncal and leg
hair reduction.telangiectasias, rosacea, erythema of
: Use on all skin types (Fitzpatrick I-VI).rosacea, angiomas and spider angiomas,
poikiloderma of Civatte, leg veins and
venous malformations.
* The removal of unwanted hair to effect
stable long-term or permanent hair
reduction.
: Use on all skin types (Fitzpatrick I-VI).
ApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510k---K072344K072564
580-1200 nm handpiece is indicated for:* The treatment of moderate inflammatory acne vulgaris.* The treatment of benign pigmented epidermal lesions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).* The treatment of face and body vascular and pigmented lesions.* The treatment of cutaneous lesions, including scars and striae.* The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.* The removal of unwanted hair to effect stable long-term or permanent hair reduction.• Use on all skin types (Fitzpatrick I-VI).570-950 nm SR Module AFT HandpieceThe Advanced Fluorescence Technology (AFT) 570-950 nm SR Module handpiece (with and without contact-cooling) is indicated for:* The treatment of moderate inflammatory acne vulgaris.* The treatment of benign pigmented epidermal lesions, including dyschromia, hyperpigmentation, melasma and ephelides (freckles).* The treatment of face and body vascular and pigmented lesions.* The treatment of cutaneous lesions, including scars and striae.· The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, melasma, angiomas and spider angiomas, poikiloderma of Civatte, leg veins and venous malformations.* The removal of unwanted hair to effect stable long-term or permanent hair reduction.• Use on all skin types (Fitzpatrick I-VI).
ApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510k---K072344K072564
IPL 620-1200 nm handpiece is indicatedfor:* The treatment of tattoos.* The treatment of moderateinflammatory acne vulgaris.* The treatment of benign pigmentedepidermal lesions including dyschromia,hyperpigmentation, melasma, andephelides (freckles), lentigines, nevi,melasma, and cafè-au-lait.• The treatment of cutaneous lesionsincluding warts, scars and striae.* The treatment of benign cutaneousvascular lesions including port winestains, hemangiomas, facial, truncal andleg telangiectasias, rosacea, erythemaof rosacea, angiomas and spiderangiomas, poikiloderma of Civatte, legveins and venous malformations.: The removal of unwanted hair and toeffect stable long-term or permanenthair reduction.• Use on all skin types (Fitzpatrick I-VI),including tanned skin.1. The removal of unwantedhair and to effect stable long-term or permanent hairreduction650-950 nm HR Module AFT HandpieceThe Advanced Fluorescence Technology(AFT) 650-950 nm HR Module handpiece(with and without contact-cooling) isindicated for:* The treatment of tattoos.* The treatment of moderateinflammatory acne vulgaris.* The treatment of benign pigmentedepidermal lesions including dyschromia,hyperpigmentation, melasma, andephelides (freckles), lentigines, nevi,melasma, and cafè-au-lait.• The treatment of cutaneous lesionsincluding warts, scars and striae.* The treatment of benign cutaneousvascular lesions including port wine stains,hemangiomas, facial, truncal and legtelangiectasias, rosacea, erythema ofrosacea, angiomas and spider angiomas,poikiloderma of Civatte, leg veins andvenous malformations.: The removal of unwanted hair and toeffect stable long-term or permanent hairreduction.• Use on all skin types (Fitzpatrick I-VI),
ApplicantBIOSBIOSALMA
Device NameSUPERBIUMAPL MEDICAL SYSTEMHARMONY XL
510k---K072344K072564
755-1200 nm handpiece is indicatedfor:* The treatment of tattoos.* The treatment of moderateinflammatory acne vulgaris.* The treatment of benign pigmentedepidermal lesions including dyschromia,hyperpigmentation, melasma, andephelides (freckles).: The treatment of cutaneous lesionsincluding warts, scars and striae.* The treatment of benign cutaneousvascular lesions including port winestains, hemangiomas, facial, truncal andleg telangiectasias, rosacea, erythemaof rosacea, angiomas and spiderangiomas, poikiloderma of Civatte, legveins and venous malformations.* The treatment of psoriasis, vitiligo,atopic dermatitis (eczema), seborrheicdermatitis.* The treatment of pseudofolliculitisbarbae (PFB).* The removal of unwanted hair to effectstable long-term or permanent hairreduction* Use on all skin types (Fitzpatrick I-VI),including tanned skin.4. The non-ablative treatmentof facial wrinkles, such as, butnot limited to:Periocular wrinklesPerioral wrinkles7. Treatment of vitiligo andpsoriasis780-950 nm SST AFT Module HandpieceThe Advanced Fluorescence Technology(AFT) 780-950 nm SST Module handpiece(with contact-cooling) is indicated for:* The treatment of tattoos.* The treatment of moderateinflammatory acne vulgaris.* The treatment of benign pigmentedepidermal lesions including dyschromia,hyperpigmentation, melasma, andephelides (freckles).: The treatment of cutaneous lesionsincluding warts, scars and striae.* The treatment of benign cutaneousvascular lesions including port wine stains,hemangiomas, facial, truncal and legtelangiectasias, rosacea, erythema ofrosacea, angiomas and spider angiomas,poikiloderma of Civatte, leg veins andvenous malformations.* The treatment of psoriasis, vitiligo,atopic dermatitis (eczema), seborrheicdermatitis.* The treatment of pseudofolliculitisbarbae (PFB).* The removal of unwanted hair to effectstable long-term or permanent hairreduction* Use on all skin types (Fitzpatrick I-VI),including tanned skin.

{26}------------------------------------------------

Section V

Bios s.r.l.
rev.03

pag. 21 of 26

{27}------------------------------------------------

Section V

pag. 22 of 26

{28}------------------------------------------------

Section V

Bios s.r.l.
rev.03

pag. 23 of 26

{29}------------------------------------------------

Section V

Bios s.r.l.

rev.03

pag. 24 of 26

{30}------------------------------------------------

Performance data VII.

Biocompatibility testing

SUPERBIUM is classified as a surface device (≤ 24 hours contact duration) in contact with skin in accordance with ISO 10993.

The patient contacting materials for the device and accessories are all well known for their compatibility.

Electrical safety and EMC

The SUPERBIUM has been tested and is in compliance with:

  • EN 60601-1, Medical electrical equipment. Part 1: General requirements for basic safety and essential । performance 2006/A11:2010/A1:2013, EN 60601-2-22:2013 Medical electrical equipment;
  • EN60601-1-2 Medical electrical equipment. Part1: General requirements for safety - Collateral standard: Electromagnetic Compatibility - Requirements and tests.

Software verification and validation testing

Software verification and validation was conducted according to FDA regulations, standards and guidance document requirements. The results of this testing conclude the software has met these requirements.

Usability testing

Usability of the SUPERBIUM have been tested in accordance with the standard EN 60601-1-6:2010

Pre series test

Pre-series tests (see attachment 15 D) have been performed to support the evidence that performances of SUPERBIUM are aligned with the identified intended uses.

Animal and clinical study

Animal and clinical studies were not necessary to demonstrate that the permormances are comparable to the predicate devices.

{31}------------------------------------------------

510(k) Premarket NotificationBios s.r.l.
SUPERBIUMrev.03
Section Vpag. 26 of 26

VIII. Conclusions

BIOS s.r.l. has determined, by using comparisons and tests, thta SUPERBIUM is substantially equivalent to the listed predicate devices in terms of intended use, typical clinical use, operational characteristics, and fundamental technological characteristics. Any differences are considered minor and do not raise new issues of the safety and effectiveness of the SUPERBIUM device when compared to the predicate devices.

§ 878.4810 Laser surgical instrument for use in general and plastic surgery and in dermatology.

(a)
Identification. (1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
(b)
Classification. (1) Class II.(2) Class I for special laser gas mixtures used as a lasing medium for this class of lasers. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 878.9.