K Number
K132033

Validate with FDA (Live)

Device Name
BM3/BM3 PLUS
Manufacturer
Date Cleared
2013-12-04

(156 days)

Product Code
Regulation Number
870.2300
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Bionet BM3/BM3 Plus Patient Monitor is intended for use by trained healthcare personnel to diagnose and monitor multiple physiological parameters of human patients. It can be used on patients from adults to neonates. The device is designed as a bedside and portable monitor that can operate in all professional medical facilities.

Physiological data include but are not restricted to: end-tidal CO2, electrocardiogram, pulse oximetry, pulse rate, noninvasive blood pressure, temperature, and respiration. The data output is displayed on an LCD screen and/or through a built-in printer as numerical data or in waveform. The device may sound an alarm when a monitored parameter falls outside preset upper or lower limits.

The device is not intended for use as an apnea monitor, and it is not intended for use during MRI or CT scans.

Device Description

The Bionet BM3/BM3 Plus Patient Monitor (BM3/BM3 Plus) is a multifunctional device that monitors vital signs of human patients from neonates to adults. Parameters monitored by BM3/BM3 Plus include end-tidal CO2 (EtCO2). electrocardiogram (ECG), pulse oximetry (SpOz), pulse rate, noninvasive blood pressure (NIBP), temperature, and respiration, Data output is displayed in numeric and/or wave form(s) on a color LCD screen. Selected parameters and waves can also be shown in print via a built-in 58 mm thermal printer. The device may sound an alarm when a monitored parameter falls outside preset upper or lower limits.

BM3/BM3 Plus is compact and can be used in either stationary mode in all professional medical facilities or on the move in medical transport mode. Its energy source can come from AC input or lithium-ion battery. BM3/BM3 Plus LAN connection capability enables the device to be built into a monitoring system, so that one person can monitor several patients at a time.

AI/ML Overview

The provided text, K132033, describes a 510(k) premarket notification for the Bionet BM3/BM3 Plus Patient Monitor. This document focuses on demonstrating substantial equivalence to previously cleared devices rather than presenting a de novo study with specific acceptance criteria and performance data for a novel device. Therefore, much of the requested information regarding acceptance criteria, performance studies, sample sizes, expert ground truth, and comparative effectiveness studies is not detailed in this submission.

Here's a breakdown of what can be extracted based on the provided text:

1. Table of Acceptance Criteria and Reported Device Performance:

The submission does not provide specific acceptance criteria in terms of quantitative performance metrics (e.g., sensitivity, specificity, accuracy percentage) that a novel device would need to meet. Instead, the "acceptance criteria" for this 510(k) submission are based on demonstrating substantial equivalence to predicate devices by:

  • Having the same intended use.
  • Having similar technological characteristics that do not raise new questions of safety or effectiveness.
  • Conforming to relevant safety standards.
Acceptance Criteria (Implicit for 510(k))Reported Device Performance (Summary from Submission)
Intended Use Equivalence: Same as predicate devices.BM3/BM3 Plus: "The Bionet BM3/BM3 Plus Patient Monitor is intended for use by trained healthcare personnel to diagnose and monitor multiple physiological parameters of human patients. It can be used on patients from adults to neonates. The device is designed as a bedside and portable monitor that can operate in all professional medical facilities." (Matches predicates)
Technological Equivalence (Non-EtCO2): Same as Bionet BM3 Plus (K082008).BM3/BM3 Plus: All features other than EtCO2 are identical to the BM3 Plus (K082008).
Technological Equivalence (EtCO2): Similar to Larson & Toubro Star 50N (K103686).BM3/BM3 Plus: Uses Sidestream and Mainstream capnography sensors, which are different from Star 50N's Microstream but both are previously cleared technologies for EtCO2 monitoring. "The difference does not impact on safety or effectiveness."
Safety and Performance Standards: Conformance to relevant standards.BM3/BM3 Plus: "BM3/BM3 Plus was shown to conform to type testing for patient monitoring equipment by an independent testing laboratory. UL tested BM3 and BM3 Plus (both with EtCO2 capabilities) for conformance to EN 60601-2-49... and found them to meet the technical requirements of the standard."

2. Sample Size Used for the Test Set and Data Provenance:

The document explicitly states: "Clinical test is not applicable to BM3/BM3 Plus."

This indicates that a specific clinical test set for evaluating accuracy or performance in human patients with a defined sample size was not conducted or submitted as part of this 510(k). The evaluation relied on comparisons to existing cleared devices and standards compliance.

3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

Since no clinical test set was used, there were no experts involved in establishing ground truth for such a set. The "ground truth" for this submission is implicitly the established safety and effectiveness of the predicate devices and the technical standards themselves.

4. Adjudication Method for the Test Set:

Not applicable, as no clinical test set requiring adjudication was used.

5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

No, an MRMC comparative effectiveness study was not done. The submission relies on demonstrating substantial equivalence to predicate devices, not on comparing the new device's performance against human readers or other AI systems.

6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

Not applicable in the context of this general patient monitor. The EtCO2 functionality itself is a measurement algorithm, but the submission does not detail its standalone performance as a novel algorithm, rather its equivalence to existing cleared technologies. The device is intended for use by "trained healthcare personnel," implying human-in-the-loop operation for interpretation and diagnosis.

7. The Type of Ground Truth Used:

For the EtCO2 functionality, the "ground truth" for demonstrating equivalence is based on the fact that both Microstream (used in Star 50N) and Sidestream/Mainstream (used in BM3/BM3 Plus) capnography technologies have been "previously cleared for the purpose of monitoring the level of carbon dioxide in exhaled breath (EtCO2) to assess a patient's ventilatory status." This refers to regulatory clearance and established scientific principles rather than a directly collected clinical ground truth for this specific device.

For the other parameters (ECG, SpO2, NIBP, temperature, respiration), the ground truth is implicitly the established performance of the legally marketed predicate Bionet BM3 Plus Patient Monitor (K082008), to which the new device is identical for these functions.

8. The Sample Size for the Training Set:

Not applicable. The submission refers to a medical device (patient monitor) which utilizes sensor technology and embedded software, rather than a machine learning or AI model that would typically require a training set. The "software" mentioned "monitors and displays data from vital signs sensor modules."

9. How the Ground Truth for the Training Set Was Established:

Not applicable, as there was no training set in the context of machine learning or AI.

{0}------------------------------------------------

K132033

510(k) Summary - Basic Information

1.1 Submitter

i

Submitter:Bionet Co., LTD
Address:#1101, 11F E&C Dream Tower III, 197-33Guro-dong, Guro-gu, Seoul, South Korea (ZIP 152-050)
Contact:Marc Goodman
Company:Noblitt & Rueland5405 Alton Parkway, Suite A530Irvine, CA 92604
Voice:(714) 258-4646
FAX:(714) 258-3990
Cell:(949) 872-1011
Email:marcgood@ca.rr.com
Date Prepared:June 26, 2013
DEC 04 2013

1.2 Device Name

Device Name:BM3/BM3 Plus
Common Name:Multifunctional patient monitor
Classification Name:Cardiac monitor (including cardiotachometer and rate alarm)(870.2300, Class II)

1.3 Identification of Legally Marketed Device

Substantial equivalence is claimed to the Bionet BM3 Plus Patient Monitor (K082008) for all functionality other than EtCO2. Substantial equivalence is claimed to the Larson & Toubro Star 50N (K103686) with respect to EtCO2 functionality.

1.4 Device Description

The Bionet BM3/BM3 Plus Patient Monitor (BM3/BM3 Plus) is a multifunctional device that monitors vital signs of human patients from neonates to adults. Parameters monitored by BM3/BM3 Plus include end-tidal CO2 (EtCO2). electrocardiogram (ECG), pulse oximetry (SpOz), pulse rate, noninvasive blood pressure (NIBP), temperature, and respiration, Data output is displayed in numeric and/or wave form(s) on a color LCD screen. Selected parameters and waves can also be shown in print via a built-in 58 mm thermal printer. The device may sound an alarm when a monitored parameter falls outside preset upper or lower limits.

BM3/BM3 Plus is compact and can be used in either stationary mode in all professional medical facilities or on the move in medical transport mode. Its energy source can come from AC input or lithium-ion battery. BM3/BM3 Plus LAN connection capability enables the device to be built into a monitoring system, so that one person can monitor several patients at a time.

Figure 1 depicts the BM3/BM3 Plus components that contribute to clinical utility in the form of functional blocks.

{1}------------------------------------------------

Figure 1: BM3/BM3 Plus Functional Components Contributing to Clinical Utility

1.5 Intended Use

The Bionet BM3/BM3 Plus Patient Monitor is intended for use by trained healthcare personnel to diagnose and monitor multiple physiological parameters of human patients. It can be used on patients from adults to neonates. The device is designed as a bedside and portable monitor that can operate in all professional medical facilities.

Physiological data include but are not restricted to: end-tidal CO2, electrocardiogram, pulse oximetry, pulse rate, noninvasive blood pressure, temperature, and respiration. The data output is displayed on an LCD screen and/or through a built-in printer as numerical data or in waveform. The device may sound an alarm when a monitored parameter falls outside preset upper or lower limits.

The device is not intended for use as an apnea monitor, and it is not intended for use during MRI or CT scans.

1.6 Comparison to Cleared Devices

The Bionet BM3/BM3 Plus is substantially equivalent to the Bionet BM3 Plus Patient Monitor (K082008) for all functionality other than EtCO2. It is substantially equivalent to the Larson & Toubro Star 50N (K103686) with respect to EtCO2 functionality. Commercial information for Star 50N can be found at the following website:

http://www.larsentoubro.com/Intcorporate/LnT Offerings/Product Templatel.aspx?res= P EBG COFF SBU PROD&pid=2570&sbu=16

{2}------------------------------------------------

K132033

P 3/5

Comparison to BM3 Plus Patient Monitor (K082008) 1.6.1

Table 1 shows a tabular comparison of BM3/BM3 Plus to the BM3 Plus predicate device. Since the only difference is the EtCO2 functionality, all other features are identical as shown in the comparison.

Table 1: Comparison of BM3/BM3 Plus Monitor with EtCO2 to BM3 Plus
--------------------------------------------------------------------------
BM3 Plus (K082008)BM3/BM3 Plus
Device TypeMultifunction Patient Monitorsame
TargetPopulationAdult, pediatric patients, and neonatessame
Where usedProfessional healthcare facilities including ambulatory.same
The Bionet BM3 Plus Patient Monitor is intended for use by trainedhealthcare personnel to diagnose and monitor multiple physiologicalparameters of human patients. It can be used on patients fromadults to neonates. The device is designed as a bedside andportable monitor that can operate in all professional medicalfacilities.
Indication forUsePhysiological data include but are not restricted to:electrocardiogram, pulse oximetry, pulse rate, noninvasive bloodpressure, temperature, and respiration. The data output is displayedon an LCD screen and/or through a built-in printer as numerical dataor in waveform. The device may sound an alarm when a monitoredparameter falls outside preset upper or lower limits.Same except alsoincludes EtCO2.
The device is not intended for use as an apnea monitor, and it is notintended for use during MRI or CT scans.
vital signsdata/ sensormodulesECG/ ECG Modulerespiration/ RESP Moduleoximetry/ SpO2 Modulenon-invasive blood pressure/ NIBP Moduletemperature/ TEMP Module.Same except alsoincludes EtCO2data from EtCO2Module.
SoftwareEmbedded software monitors and displays data from vital signssensor modulesSame except alsoincludes EtCO2.

Differences between BM3/BM3 Plus and BM3 Plus 1.6.2

The only difference between BM3/BM3 Plus and BM3 Plus is the hardware port for connecting to the EtCO2 Module and the software to process data from that sensor.

Comparison to Star 50N (K103686) 1.6.3

Table 1 shows a tabular comparison of BM3/BM3 Plus to the Star 50N, which is the predicate for EtCO2 functionality. The information for the Star 50N derives from its 510(k) summary and from information on the Larson & Toubro commercial website.

{3}------------------------------------------------

Table 2: Comparison to Star 50N with Emphasis on EtCO2 Functionality
Star 50N (K103686)BM3/BM3 Plus
Intended UseThe STAR 50N multi-parameter Patient Monitoring system isintended to monitor a single adult, pediatric and neonatalpatient's vital signs at the bedside or during intrahospitaltransport along with the appropriate accessories mentioned /supplied with the unit. Vital signs parameters include ECG (3lead /5 lead), SpO2, Respiration, Temperature, externaloptional Capnography (C02). it can also display the digitalvalues of HR/PR, SPO2, RR, Non-Invasive Blood Pressure(Systolic, Diastolic and Mean), Invasive Blood Pressure(Systolic, Diastolic and Mean), Temperature, EtCO2, andFiCO2. This monitor can also be connected to L&T CentralNursing Station (Skyline 55) and an external LCD-TFI display.The user, responsible to interpret the monitored data madeavailable, will be a professional health care provider. Thedevice permits patient monitoring with adjustable alarm limitsas well as visible and audible alarm signals., The monitor isnot intended for home use.Same
DeviceDescriptionSTAR 50N is a multi-parameter patient monitoring system forcontinuous monitoring of the physiological parameters ECG(3/5 lead), Respiration, NIBP, IBP, Temperature, SpO2 andexternal CO2 (optional).Same
Capture andDisplayCapabilitiesSTAR 5ON is a 6-channel monitor with 10.4" TFT displaycapable of displaying ECG. Respiration, SpO2, C02, digitalvalues of HR/PR, SpO2, RR, Non-Invasive Blood pressure(Systolic, Diastolic and Mean), Invasive Blood Pressure(Systolic, Diastolic and Mean), Temperature, EtCO2 andFiCO2 readings.Same except for displaysize and Invasive BloodPressure
CapnographysensorMicrostreamSidestreamMainstream
EtCO2displaysParameterEtCO2FiCO2Capnography waveformSame

1.6.4 Differences between BM3/BM3 Plus and Star 50N (for EtCO2)

The difference between BM3/BM3 Plus and Star 50N is the capnography sensor technology. Star 50N uses Microstream technology and BM3/BM3 Plus uses Sidestream and Mainstream technology. The difference does not impact on safety or effectiveness because both the Star 50N technology and the Sidestream and Mainstream technologies have been previously cleared for the purpose of monitoring the level of carbon dioxide in exhaled breath (EtCO2) to assess a patient's ventilatory status.

2. Performance Information

BM3/BM3 Plus was shown to conform to type testing for patient monitoring equipment by an independent testing laboratory. UL tested BM3 and BM3 Plus (both with EtCO2 capabilities) for conformance to EN 60601-2-49 (Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment) and found them to meet the technical requirements of the standard.

510(k) Summary (per 21 CFR 807.92)

{4}------------------------------------------------

Clinical test is not applicable to BM3/BM3 Plus.

3. Conclusion

BM3/BM3 Plus and BM3 Plus have the same intended use and no technological difference other than the BM3/BM3 Plus EtCO2 capabilities. BM3/BM3 Plus and Star 50N have the same intended use and no significant technological difference. Where BM3/BM3 Plus differs from the predicates, the differences do not affect the safety or effectiveness of BM3/BM3 Plus. Therefore, according to the principles FDA 510(k) notification, the subject device is substantially equivalent to the predicate devices with respect to safety and efficacy.

{5}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/5/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle symbol with three curved lines representing the bird's wings and body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle symbol. The logo is printed in black ink on a white background.

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-002

December 4, 2013

Noblitt & Rueland c/o Mr. Marc Goodman Senior Associate 5405 Alton Parkway Suite A530 Irvine, CA 92604-3718 US

Re: K132033

Trade/Device Name: BM3/BM3 Plus Patient Monitor Regulation Number: 21 CFR 870.2300 Regulation Name: Cardiac Monitor (including cardiotachometer and rate alarm), Regulatory Class: II (two) Product Code: MWI Dated: November 4, 2013 Received: November 6, 2013

Dear Mr. Marc Goodman:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{6}------------------------------------------------

Page 2 - Mr. Marc Goodman

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638 2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

OweFDaris-S

for

Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{7}------------------------------------------------

K132033

Indications for Use Statement

510 (k) Number (if known)

Device Name BM3/BM3 Plus Patient Monitor

Indications The Bionet BM3/BM3 Plus Patient Monitor is intended for use by trained for Use healthcare personnel to diagnose and monitor multiple physiological parameters of human patients. It can be used on patients from adults to neonates. The device is designed as a bedside and portable monitor that can operate in all professional medical facilities.

Physiological data include but are not restricted to: end-tidal CO2, electrocardiogram, pulse oximetry, pulse rate, noninvasive blood pressure, temperature, and respiration. The data output is displayed on an LCD screen and/or through a built-in printer as numerical data or in waveform. The device may sound an alarm when a monitored parameter falls outside preset upper or lower limits.

The device is not intended for use as an apnea monitor, and it is not intended for use during MRI or CT scans.

Prescription Use X (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Digitally signed by Owen
Date: 2003.12.04 09:26:59 -05'00'

Page 1 of 1

§ 870.2300 Cardiac monitor (including cardiotachometer and rate alarm).

(a)
Identification. A cardiac monitor (including cardiotachometer and rate alarm) is a device used to measure the heart rate from an analog signal produced by an electrocardiograph, vectorcardiograph, or blood pressure monitor. This device may sound an alarm when the heart rate falls outside preset upper and lower limits.(b)
Classification. Class II (performance standards).