Intended Use

The Reverse Shoulder is indicated for use in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint. The patient's joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented use only.

Device Description

The Reverse Shoulder Prosthesis is a total shoulder prosthesis designed specifically for use in patients with non-functional rotator cuffs. The articulation of this design is "inverted" compared to traditional total shoulder prosthesis. Unlike traditional total shoulders, the Reverse Shoulder is designed so that the "ball" of the articulation fits into the glenoid baseplate, and the "cup" of the articulation fits into the humeral stem. The distal surface of the glenoid baseplate is porous coated with an incorporated 6.5 cancellous screw and is intended to be used with 4 peripheral screws (3.5 non-locking and/or 5.0mm locking and non-locking) for additional fixation.

AI/ML Overview

I am sorry, but based on the provided text, there is no information available about acceptance criteria or a study proving that a device meets such criteria.

The document is a 510(k) premarket notification letter from the FDA regarding the "Encore Reverse Shoulder Prosthesis." It discusses the device's classification, indications for use, and a comparison to predicate devices, but it does not include details about:

  • Specific acceptance criteria for the device's performance.
  • A study conducted to demonstrate the device meets any performance criteria.
  • Sample sizes, data provenance, expert ground truth, adjudication methods, MRMC studies, standalone performance, or training set details.

The document explicitly states under "Clinical Testing: None provided," indicating that clinical studies were not submitted as part of this 510(k) clearance process. The non-clinical testing mentioned (shear strength and tensile strength) is very limited and not described in enough detail to extract the requested information.

Therefore, I cannot populate the table or answer the specific questions based on the provided text.

{0}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, stacked on top of each other.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

November 2, 2016

Encore Medical, L.P. Mr. William Garzon Regulatory Affairs Specialist 9800 Metric Blvd Austin. Texas 78758

Re: K112069

Trade/Device Name: Encore Reverse Shoulder Prosthesis Regulation Number: 21 CFR 888.3660 Regulation Name: Shoulder joint metal/polymer semi-constrained cemented prosthesis Regulatory Class: Class II Product Code: PHX, KWS Dated: November 2, 2011 Received: November 3, 2011

Dear Mr. Garzon:

This letter corrects our substantially equivalent letter of November 15, 2011.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must or any 1 with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical

{1}------------------------------------------------

Page 2 – Mr. William Garzon

device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the I ou may of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

Lori A. Wiggins -S

for

Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

510(k) Number (if known): _K112069

Device Name: Encore Reverse Shoulder Prosthesis

Indications for Use:

The Reverse Shoulder is indicated for use in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint.

The patient's joint must be anatomically and structurally suited to receive the selected implant(s), , and a functional deltoid muscle is necessary to use the device. The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented use only.

Prescription Use ਮ (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Mitchel D. Oines to YMXM

(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices

510(k) Number K112069

Page 1 of 1

{3}------------------------------------------------

Summary of Safety and Effectiveness

Date: July 8, 2011

Manufacturer: Encore Medical, L.P. Trade Name: DJO Surgical 9800 Metric Blvd Austin, TX 78758

Contact Person: William Garzon Regulatory Affairs Specialist Phone: (512) 834-6391 Fax: (512) 834-6313 Email: william.garzon@djosurgical.com

Product510(k) Number, Clearance Date,ClassificationProduct CodeProduct CodeRegulation and Classification Name
Reverse® Shoulder ProsthesisK041066 - March 24, 2005K051075 - May 27, 2005K092873 - October 27, 2009Class IIKWSKWSShoulder joint metal/polymer semi-constrained prosthesis per 21 CFR 888.3660

Description: The Reverse Shoulder Prosthesis is a total shoulder prosthesis designed specifically for use in patients with non-functional rotator cuffs. The articulation of this design is "inverted" compared to traditional total shoulder prosthesis. Unlike traditional total shoulders, the Reverse Shoulder is designed so that the "ball" of the articulation fits into the glenoid baseplate, and the "cup" of the articulation fits into the humeral stem. The distal surface of the glenoid baseplate is porous coated with an incorporated 6.5 cancellous screw and is intended to be used with 4 peripheral screws (3.5 non-locking and/or 5.0mm locking and non-locking) for additional fixation.

Indications for Use: The Reverse Shoulder is indicated for use in patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint. The patient's joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device. The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented use only.

Predicate Device:

Comparable Features to Predicate Device(s): Features comparable to predicate devices include the same indications, sterilization, and intended use.

Non-Clinical Testing: Mechanical testing has demonstrated the device's ability to perform under expected clinical conditions. Testing included shear strength and tensile strength.

Clinical Testing: None provided

Special 510(k) -Porous Coating Addition - RSP Baseplate

July 8, 2011

Page 1 of 1