K Number
K112008

Validate with FDA (Live)

Device Name
TOUCHPACS SUITE
Date Cleared
2012-01-06

(177 days)

Product Code
Regulation Number
892.2050
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The TouchPACS Suite software system is a picture archiving and communications system (PACS) intended to be used as a networked Digital Imaging and Communications in Medicine (DICOM) and non- DICOM information and data management system. The TouchPACS Suite PACS & DICOM Viewer Software is comprised of modular software programs that run on standard "off-the-shell" personal computers, business computers, and servers running standard operating systems. TouchPACS TouchMGR Suite DICOM Viewer Software system is an image, data storage and display software that accepts DICOM data from any OEM modality which support DICOM standard imaging data. The system provides the capability to organize images generated by OEM vendor equipment, perform digital manipulation, create graphical representations of anatomical areas, and perform quantitative measurements.

The TouchPACS Suite software is not for mammographic use.

Device Description

The TMS TouchPACS Suite is a collection of software applications coded in the Microsoft C# application language, using the Windows Presentation Foundation (WPF) libraries for user interface, that run on "off-the-shelf" Microsoft Windows-based personal or business computers to provide diagnostic imaging workstation capabilities. The system is designed to provide an environment for radiological diagnosticians which is "easy on the eyes"; so that the user can use the system for 10-12 hours per day without undue strain.

The core of the system is the database, which is a relational design, using Microsoft SQL Server 2008 Enterprise edition as the Relational Database Management System (RDBMS). The database server provides a dedicated, central place to provide disaster recovery servicing (via standard SQL Server replication), as well as the large multiterabyte storage required for a PACS system.

Attached to the RDBMS are TouchPACS client workstations, TouchMGR client workstations, and servers required for system operations: TMS DICOM SCP Server and Microsoft SQL Server. All of the aforementioned software modules, except for Microsoft SQL Server, are TMS software products.

The TouchPACS Suite PACS client workstation is intended to be a desktop computer replacement product, with the interface dominating the screen space on a workstation computer.

The TouchMGR client workstation represents the nerve center of the TouchPACS Suite, providing services for securing the TMS network, maintaining users, allowing paperless workflow, and other such critical day-to-day system maintenance tasks.

The TMS DICOM SCP Server provides multi-threaded DICOM v3 server capabilities of the TouchPACS system.

AI/ML Overview

The provided text describes a 510(k) summary for the "TouchPACS Suite," a medical imaging workstation. It focuses on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria through a dedicated study. As such, much of the requested information regarding acceptance criteria, study details, and ground truth establishment is not present in the provided document.

Here's a breakdown of the available information:

1. Table of Acceptance Criteria and Reported Device Performance

The document does not explicitly state acceptance criteria in a quantitative form (e.g., specific accuracy, sensitivity, or specificity thresholds). Instead, it relies on demonstrating that the TouchPACS Suite has similar intended use and technical features to its predicate devices. The "Predicate Device Comparison" table highlights feature parity rather than performance metrics.

Feature / CriteriaTouchPACSPredicate Devices (STAIR, RamSoft, Fuji, EZPACS)
CommunicationsTCP/IPTCP/IP
Image ArchiveYesYes
Image ProcessingYesYes
Image EditYesYes
Edit Patient DemographicsYesYes
Add and remove imagesYesYes
Combine studiesYesYes
Edit Patient Orientation informationYesYes
Set and Edit Routing InformationYesYes
JPEG Lossy/Lossless CompressionDisplay = Yes, Apply = LOSSLESSYes
JPEG 2000 Lossy/Lossless CompressionDisplay = Yes, Apply = LOSSLESSYes
Image Processing (image scaling)YesYes
Image Processing (Window Level, Pan, Zoom, Cine Display)YesYes
DICOM PrintYesYes

2. Sample size used for the test set and the data provenance

Not applicable. The document describes a comparison to predicate devices based on features and functionality, not a performance study on a test set of medical images.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

Not applicable. Ground truth establishment for a diagnostic performance study is not described.

4. Adjudication method for the test set

Not applicable. No test set adjudication method is described.

5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

No MRMC study or any study on human reader improvement with AI assistance is mentioned. The device is a PACS system, not an AI-assisted diagnostic tool.

6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

Not applicable. The device is a PACS system and viewer, not a standalone algorithm with diagnostic performance metrics. Its functionality is to store, display, and manipulate images for human interpretation.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

Not applicable. No ground truth is mentioned as this is not a diagnostic performance study. The focus is on DICOM compliance, feature parity with predicate devices, and general software functionality.

8. The sample size for the training set

Not applicable. There is no mention of a training set as the device is a PACS system, not a machine learning model.

9. How the ground truth for the training set was established

Not applicable. No training set or associated ground truth establishment is mentioned.

Summary of Acceptance Criteria and Study Details (Based on the Provided Text):

The "acceptance criteria" for the TouchPACS Suite, as presented in this 510(k) summary, are primarily based on achieving substantial equivalence to existing legally marketed predicate devices. This is demonstrated by showing that the device has:

  • Similar intended use: A networked DICOM and non-DICOM information and data management system for image storage, display, manipulation, and quantitative measurements (excluding mammographic use).
  • Similar technological characteristics/features: As detailed in the predicate device comparison table, the TouchPACS Suite provides identical or comparable functionalities (e.g., TCP/IP communication, image archiving, processing, editing, patient demographic editing, DICOM print, various compression methods).
  • No new safety and efficacy issues: A hazard analysis was conducted, and the device is deemed a "minor level of concern."

The "study" that proves the device meets these "acceptance criteria" is the comparison to predicate devices and the internal verification and validation testing of the software. The document states:

  • "The TMS TouchPACS Suite has similar intended use and technical features of the predicate devices listed above."
  • "A comparison of the labeling, substantial equivalence table, and verification and validation testing has established that the device meets its intended use and design specifications."
  • "Potential hazards are identified through risk analysis and managed through the software development process and verification/validation testing."

The document also highlights compliance with relevant standards like ACR/NEMA DICOM Version 3.0, IEC60950, and IEC/CISPR 22 as part of its safety and design verification.

{0}------------------------------------------------

5. 510(k) Summary

In accordance with the requirements of the Safe Medical Device Act, Touch Medical Solutions Inc. herewith submits a 510(K) summary for the following device.

KI12008

age lof H

Submitter Name/Address:Touch Medical Solutions, Inc.3455 University ParkwayWinston-Salem NC 27106-4109
Contact Person/Tel. #:James Owen(336) 413-6967
Date Summary Prepared:December 2, 2010
Establishment No:
Trade/Proprietary Name:TouchPACS Suite
Common/Usual Name:Medical Imaging Workstation
Classification Name:Picture Archiving and Communications System
Class/Panel:Class II, 90-LLZ, 21CFR 892.2050
Predicate Devices:
ManufacturerDevice510(k)
STAIR Systems Inc.Stair Systems PACS & DICOMViewerK100236
Ramsoft Inc.Ramsoft PACSK031562
Advance Imaging Solutions, LLCEZPACSK062878
Fuji Medical System USAFuji Synapse WorkstationSoftwareK051553
INTENDED USE STATEMENT

The TouchPACS Suite software system is a picture archiving and communications system (PACS) intended to be used as a networked Digital Imaging and Communications in Medicine (DICOM) and non- DICOM information and data management system. The TouchPACS Suite PACS & DICOM Viewer Software is comprised of modular software programs that run on standard "off-the-shelf" personal computers, business computers, and servers running standard operating systems. TouchPACS TouchMGR Suite DICOM Viewer Software system is an image, data storage and display software that accepts DICOM data from any OEM modality which support DICOM standard imaging data. The system provides the capability to organize images generated by OEM vendor equipment, perform digital manipulation, create graphical representations of anatomical areas, and perform quantitative measurements.

The TouchPACS Suite software is not for mammographic use.

{1}------------------------------------------------

KII 2008 2x 4 Page

DEVICE DESCRIPTION

The TMS TouchPACS Suite is a collection of software applications coded in the Microsoft C# application language, using the Windows Presentation Foundation (WPF) libraries for user interface, that run on "off-the-shelf" Microsoft Windows-based personal or business computers to provide diagnostic imaging workstation capabilities. The system is designed to provide an environment for radiological diagnosticians which is "easy on the eyes"; so that the user can use the system for 10-12 hours per day without undue strain.

Note: the TouchPACS Suite imaging software uses the MyDICOM .NET C# Source Code Libraries, from myDICOM LLC, compiled directly into the imaging applications. to provide full DICOM v3 compliance.

The layout and design of the 3-screen user interface evolved from the legacy concept of 3 separate computers, each with a single monitor displaying a single element of the case under review, into a modern, multi-monitor native design which incorporates large performance gains through the use of Microsoft's DirectX imaging technologies.

The core of the system is the database, which is a relational design, using Microsoft SQL Server 2008 Enterprise edition as the Relational Database Management System (RDBMS). The database server provides a dedicated, central place to provide disaster recovery servicing (via standard SQL Server replication), as well as the large multiterabyte storage required for a PACS system.

Attached to the RDBMS are TouchPACS client workstations, TouchMGR client workstations, and servers required for system operations: TMS DICOM SCP Server and Microsoft SQL Server. All of the aforementioned software modules, except for Microsoft SQL Server, are TMS software products.

The TouchPACS Suite PACS client workstation is intended to be a desktop computer replacement product, with the interface dominating the screen space on a workstation computer. This design decision was made to accommodate non- technical doctors who, we found, typically prefer to have a simplified and unobtrusive environment to work in. Color-based exam status listings were evolutionary, growing from the legacy 'field of green' display listing into the more advanced dynamic, multicolored tree view seen today in the client. TouchPACS is a multi-monitor capable client, currently configurable in a 1, 2, or 3 monitor footprint.

The TouchMGR client workstation represents the nerve center of the TouchPACS Suite, providing services for securing the TMS network, maintaining users, allowing paperless workflow, and other such critical day-today system maintenance tasks. TouchMGR users will include hospital or practice administrators, security administrators, and functional personnel who may need to make modifications to data contained in the TMS database. TMS uses DSN-less connections to the database, usually requiring port 1433 to be set as an exception in the workstation's firewall rule set. The client performs many

{2}------------------------------------------------

KII2008 Page 30

tasks, some of which are not relevant to every customer, though we encourage adoption of TMS electronic processes by our clients in order to help them streamline their office efficiency. Users only see the functions of the Touch MGR modules which they are entitled to view or use, based on security settings captured at login time. The The TMS DICOM SCP Server provides multi-threaded DICOM v3 server capabilities of the TouchPACS system. It was built to be run unattended, but a user interface, available from either the desktop or the TouchMGR client, may be used to both help monitor and control the various DICOM storage processes necessary to import each radiological study from an external source (modality, another PACS, etc.). The server incorporates a DICOM SCP service grouping that allows for DICOM ping response, client protocol negotiation, transfer syntax negotiation, and several other system-level DICOM negotiations. As each case is received, it is stored via a Service host to the local hard drive, then it is queued for storage, and then is stored as data to the main database in one of 8 available simultaneous, threaded "put away" processes.

Product NameTouchPACSSTAIRSystemsConstellationPACSRamSoftPACSFujiSynapseWorkstationSoftwareEZPACS
510(k) NumberK100236K031562K051553K062878
CommunicationsTCP/IPTCP/IPTCP/IPTCP/IPTCP/IP
Image ArchiveYesYesYesYesYes
ImageProcessingYesYesYesYesYes
Image EditYesYesYesYesYes
Edit PatientDemographicsYesYesYesYesYes
Add and removeimagesYesYesYesYesYes
Combine studiesYesYesYesYesYes
Edit PatientOrientationinformationYesYesYesYesYes
Set and EditRoutingInformationYesYesYesYesYes
JPEGLossy/LosslessCompressionDisplay = YesApply = LOSSLESSYesYesYesYes
JPEG 2000Lossy/LosslessCompressionDisplay = YesApply = LOSSLESSYesYesYesYes
ImageYesYesYesYesYes

PREDICATE DEVICE COMPARISON

{3}------------------------------------------------

Processing(image scaling)
ImageProcessing(Window Level,Pan, Zoom, CineDisplay)YesYesYesYesYes
DICOM PrintYesYesYesYesYes

The TMS TouchPACS Suite has similar intended use and technical features of the predicate devices listed above. The TouchPACS Suite is not for mammographic use.

SAFETY INFORMATION

The TouchPACS Workstation software introduces no new safety and efficacy issues other than those already identified with the predicate devices. The results of a hazard analysis, combined with the appropriate preventive measures taken indicate that the device is of minor level of concern as per the May 29, 1998 issue of the "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices". The Instructions for Use contains precautions and warnings for safe and effective use of the device.

Potential hazards are identified through risk analysis and managed through the software development process and verification/validation testing.

The TouchPACS Workstation Software complies with the following mandatory and voluntary standards:

  • ACR/NEMA DICOM Version 3.0 (Digital Imaging and Communications in o Medicine) - developed by the American College of Radiology and the National Electrical Manufacturers Association. The Synapse DICOM Conformance Statement has been included in the Labeling section as Appendix F3.
  • Note: the TouchPACS Suite imaging software uses the MyDICOM .NET C# o Source Code Libraries, from myDICOM LLC, compiled directly into the imaging applications, to provide full DICOM v3 compliance.

Recommended Specifications for Workstation Hardware include compliance with the following standards:

  • General Safety standards for all hardware: IEC60950 or equivalent. o
  • Information Technology Equipment, Radio Disturbance (Emissions) . Characteristics-Limits and Methods of Measurements, IEC/CISPR 22 (EN55022)

CONCLUSIONS

..

A comparison of the labeling, substantial equivalence table, and verification and validation testing has established that the device meets its intended use and design specifications.

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird-like symbol with three curved lines forming its body and wings. To the left of the symbol, the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion, surrounding the emblem.

DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

JAN - 6 2012

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002

Mr. James Owen Director of Development Touch Medical Solutions Inc. 3455 University Parkway WINSTON-SALEM NC 27106-4109

Re: K112008

Trade/Device Name: TouchPACS Suite Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: December 6, 2011 Received: December 14, 2011

Dear Mr. Owen:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of

{5}------------------------------------------------

medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely Yours.

Mary S Patil

Mary S. Pastel. Sc.D. Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

KII2008

Indications for Use 510(k) Number (if known): K (12008 Device Name: TouchPACS Suite

Indications for Use:

The TouchPACS Suite software system is a picture archiving and communications system (PACS) intended to be used as a networked Digital Imaging and Communications in Medicine (DICOM) and non- DICOM information and data management system. The TouchPACS Suite PACS & DICOM Viewer Software is comprised of modular software programs that run on standard "off-the-shell" personal computers, business computers, and servers running standard operating systems. TouchPACS TouchMGR Suite DICOM Viewer Software system is an image, data storage and display software that accepts DICOM data from any OEM modality which support DICOM standard imaging data. The system provides the capability to organize images generated by OEM vendor equipment, perform digital manipulation, create graphical representations of anatomical areas, and perform quantitative measurements.

The TouchPACS Suite software is not for mammographic use.

Prescription Use X (Part 21CFRS80ISubpart D) AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Mary S Postel

OK K 11.2008

N/A