K Number
K111756

Validate with FDA (Live)

Device Name
V1 SYSTEM
Date Cleared
2012-03-20

(272 days)

Product Code
Regulation Number
876.1500
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

VIDEO SYSTEM CENTER CV-V1: This video system center is intend to be used with OLYMPUS camera heads, endoscopes, monitors, EndoTherapy accessories, and other ancillary equipment for endoscopic diagnosis, treatment, and video observation.
GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-LV1: This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the upper digestive tract (including the esophagus, stomach, and duodenum).
COLONOVIDEOSCOPE OLYMPUS CF-LV1L and CF-LV11: This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve).

Device Description

The primary components of the V1 SYSTEM consists of two Olympus colonovideoscopes; CF-LV1L and CF-LV11 (which are identical except for their working) lengths, an Olympus gastrointestinal videoscope; GIF-LV1 and a video system center. This system is intended for endoscopic diagnosis, treatment and video observation of the upper and lower digestive tract. The V1 SYSTEM is designed to be used with specified monitors, EndoTherapy accessories and other ancillary equipment.
The primary components of the subject system, which are part of this submission, are: VIDEO SYSTEM CENTER OLYMPUS CV-V1 GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-LV1 COLONOVIDEOSCOPE OLYMPUS CF-LV1L COLONOVIDEOSCOPE OLYMPUS CF-LV11
CV-V1 can be used with Olympus endoscope models, such as gastorointestinal videoscope GIF-LV1 and colonovideoscope CF-LV1L/I. The subject premarket notification is specific for gastrointestinal videoscopes and colonovideoscopes.
The GIF-LV1, CF-LV1L/I can be used with VIDEO SYSTEM CENTER OLYMPUS CV-V1. The light source and the LG bundle are not used, instead, there are LEDs in the distal end of the scope that runs by electric power from the CV-V1 and light up the distal end. The newly designed one-touch connector is water proof.

AI/ML Overview

The provided 510(k) summary for the V1 SYSTEM describes a modification to an endoscopic video imaging system, specifically regarding a change in the lighting method from an external light source to integrated LEDs within the endoscopes. The submission focuses on demonstrating substantial equivalence to a predicate device rather than presenting a study to prove performance against specific acceptance criteria for diagnostic accuracy or clinical outcomes.

Therefore, many of the requested elements for describing acceptance criteria and a study proving device performance are not applicable or cannot be extracted from this document, as the submission does not detail a clinical study of the V1 SYSTEM's diagnostic or therapeutic effectiveness against a specific set of acceptance criteria. The focus is on technical performance relative to safety standards and equivalence to a predicate device.

However, I can extract information related to the technical testing conducted.

1. Table of Acceptance Criteria and Reported Device Performance

The document does not provide a table of acceptance criteria for diagnostic performance or specific clinical outcomes. Instead, it refers to the performance of non-clinical tests based on various standards. The acceptance criteria for these tests would typically be compliance with the specified standard.

Acceptance Criteria CategorySpecific Standard/TestReported Performance
Basic Safety and PerformanceIEC 60601-1Performed in accordance with standard
Basic Safety and PerformanceIEC 60601-1-1Performed in accordance with standard
Basic Safety and PerformanceIEC 60601-1-2Performed in accordance with standard
Basic Safety and PerformanceIEC 60601-2-18Performed in accordance with standard
Mechanical PerformanceVerification and comparison studiesConducted and results provided (details not specified)
Functional PerformanceVerification and comparison studiesConducted and results provided (details not specified)
BiocompatibilityIntracutaneous Reactivity Test.docResults provided (details not specified)
BiocompatibilityCytotoxicity Study.docResults provided (details not specified)
BiocompatibilitySkin Sensitization Test.docResults provided (details not specified)
Risk AnalysisISO 14971:2007Carried out in accordance with established in-house acceptance criteria based on ISO 14971:2007. Design verification tests and acceptance criteria identified and performed.

The document states, "The newly lighting method has been confirmed that the safety and effectiveness are equivalent i compare with the predicate devices." This implies that the performance of the new lighting method was deemed equivalent to the predicate, likely through technical testing and comparison of image quality, illumination, etc., though specific metrics are not detailed here.

2. Sample Size Used for the Test Set and Data Provenance

This information is not provided in the 510(k) summary. The document describes non-clinical testing rather than a clinical study with a patient "test set." The "test set" would refer to the physical devices (V1 SYSTEM components) themselves. No patient data is mentioned.

3. Number of Experts Used to Establish Ground Truth and Qualifications

This information is not provided. The testing described is non-clinical (safety, mechanical, functional, biocompatibility) and does not involve establishing ground truth from expert assessments of clinical data.

4. Adjudication Method

This information is not provided as no expert assessment of clinical data is described.

5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

No MRMC study is mentioned. The submission is for a medical device (endoscopic system) which is a tool for human examiners, and the focus is on the device's technical equivalence and safety, not on human reader performance with or without AI assistance.

6. Standalone Algorithm Performance

Not applicable. The V1 SYSTEM is an endoscopic video imaging system, not an AI algorithm. It is a device intended for human-in-the-loop use for diagnosis and treatment.

7. Type of Ground Truth Used

Not applicable in the context of a clinical study for diagnostic accuracy. For the non-clinical tests, the "ground truth" would be established by the specifications and standard requirements outlined in the referenced IEC and ISO standards. For example, for biocompatibility tests, the "ground truth" is whether the materials meet the safety thresholds defined by ISO 10993.

8. Sample Size for the Training Set

Not applicable. The V1 SYSTEM is not an AI algorithm that requires a training set of data.

9. How the Ground Truth for the Training Set Was Established

Not applicable. The V1 SYSTEM is not an AI algorithm.

{0}------------------------------------------------

K111756
-/

MAR 2 0 2012

510(k) SUMMARY

V1 SYSTEM

1 General Information

■ Applicant:

I Official Correspondent:

● Manufacturer:

Device Identification 2

  • Device Trade Name:
  • 의 Common Name:

트 Regulation Number:

■ Regulation Name:

■ Regulatory Class:

Classification Panel: ●

Product Code: ■

OLYMPUS MEDICAL SYSTEMS CORP. 2951 Ishikawa-cho, Hachioji-shi, Tokyo, Japan 192-8507 Establishment Registration No: 8010047

Stacy Abbatiello Kluesner, M.S., RAC Regulatory Affairs & Quality Assurance Olympus America Inc. 3500 Corporate Parkway PO Box 610 Center Valley, PA 18034-0610, USA Phone: 484-896-5405 FAX: 484-896-7128 Email: stacy.kluesner@olympus.com

OLYMPUS MEDICAL SYSTEMS CORP. 34-3 Hirai, Hinode-machi, Nishitama-gun, Tokyo, JAPAN 190-0182 Establishment Registration Number: 3003637092

V1 SYSTEM

Endoscopic Video Imaging System

21 CFR 876.1500

Endoscope and accessories

ll

Gastroenterology and urology

FDF, FDS

{1}------------------------------------------------

K111756
-2

3 Predicate Device Information

Subject Device(Part of this Submission)Predicate DevicePD's510(k)No.
VIDEO SYSTEM CENTER OLYMPUSEVIS EXERA II XENON LIGHTSOURCE OLYMPUS CLV-180K100584
CV-V1EVIS EXERA II VIDEO SYSTEMCENTER OLYMPUS CV-180K100584
GASTROINTESTINAL VIDEOSCOPEOLYMPUS GIF-LV1 (Hereinafter referredEVIS EXERA II GASTROINTESTINALVIDEOSCOPE OLYMPUS GIF TYPEQ180K100584
COLONOVIDEOSCOPE OLYMPUSCF- LV1L (Working Length: 1680mm)andCF-LV1I (Working Length: 1330mm)EVIS EXERA IICOLONOVIDEOSCOPEOLYMPUS CF TYPE Q180ALK100584

4 Device Description

V1 SYSTEM

The primary components of the V1 SYSTEM consists of two Olympus colonovideoscopes; CF-LV1L and CF-LV11 (which are identical except for their working) lengths, an Olympus gastrointestinal videoscope; GIF-LV1 and a video system center. This system is intended for endoscopic diagnosis, treatment and video observation of the upper and lower digestive tract. The V1 SYSTEM is designed to be used with specified monitors, EndoTherapy accessories and other ancillary equipment.

The primary components of the subject system, which are part of this submission, are: VIDEO SYSTEM CENTER OLYMPUS CV-V1 GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-LV1 COLONOVIDEOSCOPE OLYMPUS CF-LV1L COLONOVIDEOSCOPE OLYMPUS CF-LV11

CV-V1

CV-V1 can be used with Olympus endoscope models, such as gastorointestinal videoscope GIF-LV1 and colonovideoscope CF-LV1L/I. The subject premarket notification is specific for gastrointestinal videoscopes and colonovideoscopes.

GIF-LV1, CF-LV1L/I

The GIF-LV1, CF-LV1L/I can be used with VIDEO SYSTEM CENTER OLYMPUS CV-V1. The light source and the LG bundle are not used, instead, there are LEDs in the distal end of the scope that runs by electric power from the CV-V1 and light up the distal end. The newly designed one-touch connector is water proof.

{2}------------------------------------------------

5 Indications for Use

VIDEO SYSTEM CENTER OLYMPUS CV-V1

This video system center is intend to be used with OLYMPUS camera heads, endoscopes, monitors, EndoTherapy accessories, and other ancillary equipment for endoscopic diagnosis, treatment, and video observation.

The indications include the applicability of endoscopy and endoscopic treatment.

GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-LV1

This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the upper digestive tract (including the esophagus, stomach, and duodenum).

COLONOVIDEOSCOPE OLYMPUS CF-LV1L and CF-LV1L

This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, and ileocecal valve).

6 Comparison of Technological Characteristics

· The V1 SYSTEM is basically identical to the predicate device in intended use, and similar in specifications.

Video System Center:

When compared to the predicate device, the subject device has the similar technological features such as the video signal output, automatic gain control/ iris mode function and air feeding pump. There are differences in the input current and compatible endoscopes, however, these differences are considered as minor.

Endoscope:

When compared to the predicate device, the subject device has the similar technological features such as the depth of field, direction of forward view, bending section and inner diameter of instrument channel. There are differences in the field of view, lighting method and outer of distal end/ insertion tube, however, these differences are considered as minor. The following non-clinical test and usability studies were performed.

{3}------------------------------------------------

K///756

-4

7 Substantially Equivalent Discussion

The subject device, V1 SYSTEM, is a modification to LED lightning system. The indications for use, principles of operation and fundamental technology of the V1 SYSTEM are similar to the predicate devices.

The maior difference from the predicate devices is lighting method as follow:

  • The subject device is provided LED in the endoscopes and the Video Processor is able to supply ー power for the LED.
  • The predicate device (K100584) has the light guide cable in endoscopes and the light source is able to supply light.

The newly lighting method has been confirmed that the safety and effectiveness are equivalent i compare with the predicate devices.

The CV-V1 and the GIF-LV1 and CF-LV1L/I are similar in method of operation and design as the predicate devices. In addition, similar or identical materials are used and biocompatibility results were provided.

Summary of Non-Clinical Testing 8

The following non-clinical test and usability studies were performed.

Basic safety and performance testing was performed in accordance with IEC 60601-1, 60601-1-1, 60601-1-2. 60601-2-18. In addition, verification and comparison studies were conducted to evaluate the mechanical and functional performance. Specially, test results in the following areas were provided. Biocompatibility

Intracutaneous Reactivity Test.doc Cytotoxicity Study.doc Skin Sensitization Test.doc

The following standards were used during the design and validation of the subject devices.

  1. IEC 60601-1: 1988, A1: 1991, A2: 1995 2) IEC 60601-1-1: 2000, 3) IEC 60601-1-2: 2007 4) IEC 60601-2-18: 1996, A1: 2000

  2. ISO 14971: 2007

    1. ASTM E1837-96: 2007
  1. ANSI/AAMI/ISO 11135-1: 2007

  2. ISO 10993-1: 2009

  3. ISO 10993-5: 2009

  4. ISO 10993-10: 2002

  5. ISO 10993-11: 2006

The risk analysis was carried out I accordance with established in-house acceptance criteria based on ISO 14971:2007. The design verifications tests and their acceptance criteria were identified and performed as a result of their risk analysis assessment.

{4}------------------------------------------------

K111756
-5

9 Conclusion

.

When compared to the predicate device, the V1 SYSTEM does not incorporate any significant changes in intended use, method of operation, material, or design that could affect the safety or effectiveness of the device.

:

{5}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002

OLYMPUS MEDICAL SYSTEMS CORP. % Ms. Stacy Abbatiello Kluesner, M.S., RAC Project Manager Olympus America Inc. 3500 Corporate Parkway P.O. Box 610 CENTER VALLEY PA 18034

MAR 2 0 2012

Re: K111756

Trade/Device Name: V1 SYSTEM Regulation Number: 21 CFR§ 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: II Product Code: FDF Dated: February 24, 2012 Received: February 27, 2012

Dear Ms. Kluesner:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical

{6}------------------------------------------------

Page 2 -

device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable; the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Benjamin R. Fisher, Ph.D.

Benjamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{7}------------------------------------------------

K111756

Indications for Use

510(k) Number (if known):

Device Name: V1 SYSTEM

Indications For Use:

VIDEO SYSTEM CENTER CV-V1

This video system center is intend to be used with OLYMPUS camera heads, endoscopes, monitors, EndoTherapy accessories, and other ancillary equipment for endoscopic diagnosis, treatment, and video observation.

GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-LV1

This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the upper digestive tract (including the esophagus, stomach, and duodenum).

COLONOVIDEOSCOPE OLYMPUS CF-LV1L and CF-LV11

This instrument is intended to be used with an Olympus video system center, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery and is indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve).

Prescription Use_ (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Heidi Leum

Page 1 of 1

(Division Sign-Off)
Division of Reproductive, Gastro-Renal, and
Urological Devices
510(k) Number L11756

§ 876.1500 Endoscope and accessories.

(a)
Identification. An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.(b)
Classification —(1)Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.